Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹5.2 L (4.94%)Admitted-Finance | ₹1.1 Cr+₹5.2 L (4.94%) | L2 | Admitted-Finance |
| 3 | L3₹1.2 Cr+₹13.6 L (12.9%)Admitted-Finance | ₹1.2 Cr+₹13.6 L (12.9%) | L3 | Admitted-Finance |
| 4 | L4₹1.2 Cr+₹17.0 L (16.1%)Admitted-Finance | ₹1.2 Cr+₹17.0 L (16.1%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Trade Linkers Associates L4 | M/s Sai Electricals L2 | M/S KUNDAL ELECTRICAL WORKS AND SUPPLIERS L3 | M/S CHOUDHARY ELECTRICAL WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Supply of main equipments | |||||||
| 1.01 | 3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 2500 Amps or higher, of 3 phase, 50 c/s and 40 KA for 1 second) along with supporting structures etc. complete in all Respects SS BODY,UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES | 4 | Nos | 14,00,000 ₹56,00,000 | 9,00,000 ₹36,00,000 | 9,51,000 ₹38,04,000 | 8,00,000 ₹32,00,000 Lowest |
| 1.02 | Single phase 50Hz, 145KV CT(1200-600-300/1-1-1-1-1A),100KA(Peak),Class A insulation, Burden 20VASingle phase, 50 c/s 145KV Current Transformers 1200- 600-300/1-1-1-1A, 40 KA for onesecond, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA 3 NO PS
CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill oftransformer oil plus20% extra and all accesories, auxiliaries etc | 3 | Nos | 2,10,000 ₹6,30,000 | 2,30,000 ₹6,90,000 | 2,49,000 ₹7,47,000 | 2,00,000 ₹6,00,000 Lowest |
| 1.03 | Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK. Acc Class 0.2 | 6 | Nos | 2,00,000 ₹12,00,000 Lowest | 2,20,000 ₹13,20,000 | 2,70,000 ₹16,20,000 | 2,00,000 ₹12,00,000 Lowest |
| 1.04 | Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries. | 3 | Nos | 62,000 ₹1,86,000 | 1,20,000 ₹3,60,000 | 37,000 ₹1,11,000 Lowest | 1,00,000 ₹3,00,000 |
| 1.05 | 33KV VCB (36 KV, 2000 Amps of 3 phase, 50 c/s and 31.5 KA for 3 sec) outdoor type with all accessories and auxiliaries along with supporting structures etc. complete in all Respects SS BODY, UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES | 4 | Nos | 3,72,000 ₹14,88,000 | 3,50,000 ₹14,00,000 Lowest | 4,16,000 ₹16,64,000 | 3,60,000 ₹14,40,000 |
| 1.06 | Single phase, 50 c/s outdoor 33KV PT (33/√3)KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms GALVANISED TANK. Acc Class 0.2 | 3 | Nos | 60,000 ₹1,80,000 Lowest | 2,30,000 ₹6,90,000 | 90,000 ₹2,70,000 | 1,20,000 ₹3,60,000 |
| 1.07 | Single Phase 50 c/s, outdoor metal oxide gapless
type, 30KV (rms) Surge Arrestor, class 3
including Surge counters/monitors, insulating
base all associated accessories, auxiliaries. | 6 | Nos | 25,000 ₹1,50,000 Lowest | 1,20,000 ₹7,20,000 | 38,000 ₹2,28,000 | 50,000 ₹3,00,000 |
| 1.08 | Battery Bank 220 V,300 AH , of 110 No. cells of 2 V
each, sealed maintenance free VRLA type,High
impact Polyprophelene copolymer container,flame
retardant. | 1 | Nos | 11,60,000 ₹11,60,000 | 6,50,000 ₹6,50,000 | 15,00,000 ₹15,00,000 | 4,00,000 ₹4,00,000 Lowest |
| 1.09 | 220V Battery charger (Three phase): Battery charger as well as Automatic Regulators shall be of static type compatible with VRLA Batteries. Should also have necessary temperature sensors. Should have both Automatic & Manual control of output voltage & current.
(I) Float charging & load current ratings: 30A/60A/70A/100A at 220V to 252V
(II) Boost charging current rating: 50A/55A/60A/70A/80A/100A at 198V to 296/302V D.C. | 1 | Nos | 4,85,000 ₹4,85,000 | 5,00,000 ₹5,00,000 | 11,60,000 ₹11,60,000 | 1,90,000 ₹1,90,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
19 Aug 2025, 2:00 pmClosed
Executive Engineer TLMD I Jammu
Division Office TLMD I Janipur Jammu
Supply Erection Testing and Commissioning of new equipments at Grid Station Pounichak
2025_PDD_282434_1
TLMD-I/J/03 dated 25-07-2025
Open Tender
Electrical Works
Turn-key
210 days
Grid station Pounichak
Ref SBD
3 documents required · 3 mandatory
₹5,000
Executive Engineer TLMD I
₹2.6 L
Division Office TLMD I Janipur Jammu
30 Aug 2025
25 Jul 2025
20 Aug 2025
25 Jul 2025
19 Aug 2025
25 Jul 2025
4 Aug 2025
Amount
Supply of main equipments
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 2500 Amps or higher, of 3 phase, 50 c/s and 40 KA for 1 second) along with supporting structures etc. complete in all Respects SS BODY,UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
Single phase 50Hz, 145KV CT(1200-600-300/1-1-1-1-1A),100KA(Peak),Class A insulation, Burden 20VASingle phase, 50 c/s 145KV Current Transformers 1200- 600-300/1-1-1-1A, 40 KA for onesecond, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill oftransformer oil plus20% extra and all accesories, auxiliaries etc
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK. Acc Class 0.2
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
33KV VCB (36 KV, 2000 Amps of 3 phase, 50 c/s and 31.5 KA for 3 sec) outdoor type with all accessories and auxiliaries along with supporting structures etc. complete in all Respects SS BODY, UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
Single phase, 50 c/s outdoor 33KV PT (33/√3)KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms GALVANISED TANK. Acc Class 0.2
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Battery Bank 220 V,300 AH , of 110 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant.
220V Battery charger (Three phase): Battery charger as well as Automatic Regulators shall be of static type compatible with VRLA Batteries. Should also have necessary temperature sensors. Should have both Automatic & Manual control of output voltage & current. (I) Float charging & load current ratings: 30A/60A/70A/100A at 220V to 252V (II) Boost charging current rating: 50A/55A/60A/70A/80A/100A at 198V to 296/302V D.C.
D.G Set (63 KVA)
Erection,Testing and commissioning of new equipments and dismantaling of old equipments and write back to divisional store Janipur Jammu
3 pole, SF6 gas filled, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (145KV, 2500 Amps or higher, of 3 phase, 50 c/s and 40 KA for 1 second) along with supporting structures etc. complete in all Respects SS BODY,UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
Single phase 50Hz, 145KV CT(1200-600-300/1-1-1-1-1A),100KA(Peak),Class A insulation, Burden 20VASingle phase, 50 c/s 145KV Current Transformers 1200- 600-300/1-1-1-1A, 40 KA for onesecond, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA 3 NO PS CORE, 1 NO 5P20, 1 NO 0.2s class, Galvanised tank, including first fill oftransformer oil plus20% extra and all accesories, auxiliaries etc
Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3)V, One min power freq withstand 275KVrms GALVANISED TANK. Acc Class 0.2
Single Phase 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
33KV VCB (36 KV, 2000 Amps of 3 phase, 50 c/s and 31.5 KA for 3 sec) outdoor type with all accessories and auxiliaries along with supporting structures etc. complete in all Respects SS BODY, UNIVERSAL SPRING CHARGING MOTOR WITH MANDATORY SPARES
Single phase, 50 c/s outdoor 33KV PT (33/√3)KV/ (110/√3)V with Highest System Voltage36KV, One min power freq withstand 70KVrms GALVANISED TANK. Acc Class 0.2
Single Phase 50 c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor, class 3 including Surge counters/monitors, insulating base all associated accessories, auxiliaries.
Battery Bank 220 V,300 AH , of 110 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant.
220V Battery charger (Three phase): Battery charger as well as Automatic Regulators shall be of static type compatible with VRLA Batteries. Should also have necessary temperature sensors. Should have both Automatic & Manual control of output voltage & current. (I) Float charging & load current ratings: 30A/60A/70A/100A at 220V to 252V (II) Boost charging current rating: 50A/55A/60A/70A/80A/100A at 198V to 296/302V D.C.
D.G Set (63 KVA)
M/s Sai Electricals (BID ID -2437393)
M/S KUNDAL ELECTRICAL WORKS AND SUPPLIERS (BID ID -2440404)
Trade Linkers Associates (BID ID -2440351)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .