Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹18.9 L+₹1.5 L (8.45%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹21.2 L+₹3.8 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Nal, Bikaner
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_456447_1
GE (AF) NAL/T-12/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Nal
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Nal
₹40,000
GE (AF) NAL
7 Sept 2021
2 Jul 2021
12 Aug 2021
2 Jul 2021
4 Aug 2021
16 Jul 2021
5 Jul 2021 - 14 Jul 2021
15 Jul 2021
60 days
Amount
M&L checking the serviceability of different spares / components / parts of security light fittings (HPSV, HPMV, Metal Halide, T-5, LED Lights, Post top, Trafic light fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) other than those mentioned in item No 2 to 11 below either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed.
Note for item No. 1.00 :- (i) New parts shall be measured and paid for separately under relevant item of this schedule as 'Supply only'. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, wire for internal wiring,gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost there of is deemed to be included in the rates quoted by the contractor in above item including rectification of cable fault & over head fault by fault finding/identification. (iv) Contractor shall be paid only one time labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition. (v) Contractor shall attend the said job as and when ordered by Engineer-in-Charge and replace the spare parts / fittings immediately without losing the time. (vi) Immediately, on acceptance of contract, material shall be brought by the contractor on priority basis after getting approved and shall attend the complaint on priority basis. (vii) Site of work is scattered in Domestic and Technical area and the contractor shall consider this aspect while quoting the rates. (viii) Contractor's supervisor shall attend the office of AGE E/M at 0900 hrs every day (except holiday) to get the task / location / nature of compaint and in the evening, shall give feed back of compaint.
Supply only PVC insulated and sheathed copper conductor 1.5 sqmm two single core multistrand cable for electric connection from overhead line / junction box to street light complete all as specified and directed.
Supply only HPSV lamp 250 watt elliptical / tubular E-40, complete all as specified and directed.
Supply only HPSV lamp 400 watt elliptical / tubular E-40, complete all as specified and directed.
Supply only HPSV lamp 70 watt elliptical / tubular E-27, complete all as specified and directed.
Supply only HPSV lamp 150 watt elliptical / tubular E-40, complete all as specified and directed.
Supply only electronic igniter for integral luminaries suitable for 70W / 150W / 250W / 400W HPSV/MH fitting, complete all as specified and directed. Make:- Crompton Cat Part IGN112S/MH or equivalent of Bajaj/Havells.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 400 Watt suitable for HPSV/HPMV/metal halide 400W lamp complete all as specified and directed. Make:- Crompton Cat Part HDBL 40S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 250 Watt suitable for HPSV/HPMV/metal halide 250W lamp,all as specified and directed. Make:-Crompton Greaves Cat Part HDBL 25S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 70 Watt suitable for HPSV/HPMV/metal halide 70W lamp, complete all as specified and directed. Make:- Crompton Greaves Cat Part HDBL 07S/MH or equivalent of Havells/Philiphs.
Supply only HPSV open construction heavy duty VPIT copper HPSV/HPMV/metal halide ballast 150 Watt suitable for HPSV/HPMV/metal halide 150W lamp, complete all as specified and directed. Make:- Crompton Greaves Cat Part HDBL 15S/MH or equivalent of Havells/Philiphs.
S&F as in repairs street light bracket made of GI Pipe 40mm bore light grade 1.5 Mtr in length, bent to required shape fixed with 2 Set of MS Clamps made out of flat iron 40x4mm, incl bolts, nuts and washers complete all as specified and directed.
S&F as in repairs Junction box (Bus bar chamber box) of size 250mm x 200mm x 105mm made out of palstic suitable for 415 Volt, 4 Way TPN aluminium bus bars of capacity 100 amps with 01 No. MCB, SP, 2.5 Amp, 240 volts, 10 KA for controlling the street light fixed to the pole with nut, bolts and washers including providing the electrical connection for incoming / outgoing cable through proper lugs/thimbles,complete all as specified and directed.
S&F as in repairs conventional LED street light 70 watt, 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver complete all as specified and as directed. Make :- Havells Cat Part ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent in Crompton/Bajaj/Surya
S&F as in repairs conventional LED street light 60 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver complete all as specified and as directed. Make:- Havells Cat Part ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent in Crompton/Bajaj/Surya
Supply and fix as in repairs LED street light 45 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection IP.66 batter optics for uniform distribution having surge protection 5 KV, sealed driver in replacement of conventional street light 70/125 watt SV/MV complete all as specified and directed. Make:- Havells Cat Part ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent in Crompton/Bajaj/Surya
S&F as in repairs conventional LED 120W flood light fitting with lense, high luminous efficacy,protected to IP 65, toughened glass efficient high out put emitter LED for better distribution applicable for area lighting including electrical connection complete all as specified and directed. make:- Havells Cat Part JETAIRISFLS120WLED757SYMLTG or equivalent in Crompton/Bajaj/Surya.
S&F as in repairs conventional LED 180 W flood light fitting with lense, high luminous efficacy,protected to IP 65, toughened glass efficient high out put emitter LED for better distribution applicable for area lighting including electrical connection complete all as specified and directed. Make:- Havells. Cat ref ASSEMBLEDCGBOXVALOUR180WAP or equivalent in Crompton/Bajaj/Surya
Excavation in any type of soil in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches for laying of cable / pipes etc.and getting out, complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exc 25cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Taking out defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor Cross sectional area 50 Sqmm, 3.5 core from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
All as per description of item No. 22.00 here-in-before but Cross sectional area 25 sq mm, 4 core
All as per description of item No. 22.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core.
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 25 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing vompete all as specified and directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately.
All as per description of serial item No. 25.00 here in before but cross sectional area of cable 35 sqmm 3.5 core
All as per description of serial item No. 25.00 here in before but cross sectional area of cable 50 sqmm 3.5 core
M&L sand cushioning using dry and clean tibba sand in two layers, first laylers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ ducts including consolidation of each layers complete all as specified and directed.
Supply and laying in trenches, well burnt old size sub Class ‘B’ bricks, laid flat, abutting each other for cable protection complete all as specified and as directed.
Material and labour for 20 mm stone aggregate in sub stn yard as lizard guard after making good to the existing surface complete all as specified and directed.
Supplying and laying 50mm bore GI tubing light grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors / Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed. Note:-MS works including painting will be measured under seperate item in Schedule
S&F as in repairs danger notice plate 20x15cm size made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour for LT, and fixed with M.S. clamps, bolts and nuts of approved size, all as specified and directed.
All as per description of serial item No. 32.00 here in before but size 25 x 20 cm for HT
Demolition of cement concrete (un- reinforced) in ground floor and paving n. exc 15 cm thick bleow or above ground level complete all as specified and directed. Note:- The demolished material should be disposed off out side the MOD land. The contractor shall quote his rates considering this above factor.
M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping to poles including necessary form work complete all as specified and as directed
M&L for painting of steel tubular pole 9.0 m long, by applying one coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
Material and labour for painting with one coats of synthetic enamel paint on RCC pole from 1.5 mtr above the GL and balance 1.5 m from ground level will be painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed..
M&L for painting of steel tubular pole 11.0 m long with swan neck for street light by applying one coat of alluminum paint after scraping/brushing and cleaning. Pole No will be written on pole by black paint in yellow circle of 150 mm dia complete all as specified and directed.
M&L trimming of tree branches on both sides of LT/ HT overhead line complete all as specified and directed. NOTE : (i) Cutting branches shall be dumped outside the air force premises. (ii) Contractor shall provide the ladder of required size including T&P to his worker and nothing extra shall be paid on this account. (iii) Before commencement of trimming work, electric shut down shall be got managed by the contractor and sufficient man power shall be deployed on the particular time so that the task given by the Engineer-in-Charge shall be completed with the time allowed.
S&F as in repair Astronomical timer switch 110/240 volts complete all as specified and directed. Make : Havells Cat No DHTKW01016 or equivalent in make L&T / Crompton / Bajaj
Supplying, fixing as in repair Power contactor 63 Amp 4 pole 415 V, 50 Hz model MCX 12 with front mounting auxiliary contacts 2 No+ 2 NC rating Make : L&T Cat no CS97014 or equivalent in Make Havells
Supply and fixing as in repairs MCCB, 100A, rupturing capacity 16 KA , 415 volts, 4 pole in existing DB of existing make and making connections complete all as specified & directed.
M&L hardcore of broken boulders of gauge n exc 63mm, deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base / sub floors surface finished even and rough to receive floor topping complete all as specified and directed.
M&L Chequered cement concrete coloured tiles 25cm x 25cm x 25mm thick set, jointed in neat cement slurry and pointed in grey cement with pigments laid over and including 15mm thick cement screed bedding in cement mortar 1:4 complete all as specifed and directed.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework built in cement mortar or cement lime mortar complete all as specifieed and directed.
M&L for PCC 1:3:6, type C-2 using 40mm graded stone aggregate as in foundation of 4 pole/2 pole steel structure for transformer proposed, complete all as specified & directed.
M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed.
S&F as in repair welded steel wire fabric n. exc 4 kg/ sqm complete to wood or steel members complete all as specified and directed.
M&L for painting of new steel surface, by applying two coat of synthetic enamel paint after scraping/brushing and cleaning on new steel surface over a coat of primer including necessory preparation complete all as specified and directed.
S&F as in repair butt hinges medium weight cold rolled 100 mm complete all as specified and directed.
Material and labour for writing HT/LT Pole No on perimeter light pole/road light pole etc. with one coat of synthetic enamel paint (heat resistant) in black colour on a yellow circle 150mm dia( ie PT 01 for perimeter Tech area, PD -01 for perimeter Domestic Ara, LTT -01 for low tension technical area and LTD -01 for low tension domestic area) including scrapping the existing paint and preparation of surfaces complete all as specified and directed.
BIDAWAT ENTERPRISES
RBS ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .