Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.5 L+₹4.2 L (31.6%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.6 L+₹4.3 L (32.0%)Rejected-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 | |
| 4 | L4₹20.8 L+₹7.5 L (56.1%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L4 | Rejected-AOC L4 | |
| 5 | L5₹21.0 L+₹7.7 L (57.8%)Rejected-AOC NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L5 | Rejected-AOC L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 May 2025, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
REPAIR OF WINDOW TYPE ACS, SPLIT ACS, WATER COOLERS, REFRIGERATIONS AND DEEP FREEZER AT AFS YELAHANKA
2025_MES_706305_1
8364/E8
Open Tender
Civil Works
Item Rate
330 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹40,000
Yes
18 Jul 2025
2 May 2025
6 Jun 2025
2 May 2025
30 May 2025
16 May 2025
Amount
Material and Labour for servicing of spilt type AC indoor/outdoor of capacity 1/1.5/2.0 TR of any make and type complete all as specified and directed including following item of works: (a) Cleaning of complete unit including cooling coil condenser, Fan (Outdoor unit), blower etc. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Checking of refrigerant piping and carrying out necessary repairs/replacement to copper tubing and insulation to copper tubing. (d) Checking of all components/accessories for their serviceability and replacement of defective components/accessories (e) Greasing and oiling of fan motor Note: (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items.
All as per item No. 1 above but capacity 3 TR (2x1.5 TR) with 01 No outdoor unit and 02 Nos indoor unit complete all as specified and directed
Material and Labour for servicing of Window AC 1/1.5/2.0 TR capacity complete all as specified and directed including following items of works.:- (a) Cleaning of complete unit including cooling coil condenser, Fan(Outdoor unit), blower, etc as directed by Engineer-in-Charge. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note : (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items . (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer as directed by Engineer-in-charge functionality of AC is deemed to be included in unit rate
Maintenance/repairs and testing of Deep freezer of capacity 300/320/500 ltrs complete all as specified and directed including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of Deep Freezer is deemed to be included in unit rate .
Maintenance/repairs and testing of Water coolers of capacity 30 to 150 ltrs complete all as specified and directed including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of water cooler is deemed to be included in unit rate .
Maintenance/repairs and testing of Refrigerators of capacity 165 to 360 ltrs complete all as specified and directed including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable itmes wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of refrigerator is deemed to be included in unit rate .
Supply & fixing of new filter drier for 1.5 TR Split type AC capacity complete all as specified and directed.
Supply & fixing of new Air filter for 1.5 TR Split type AC capacity complete all as specified and directed.
Supply and fixing of new filter drier for 3 TR (2 x 1.5 TR) Split type AC capacity complete all as specified and directed.
Supply and in repair of Plastic filter for window type AC 1.0/1.5/2.0 ton capacity complete all as specified and directed.
Supply and fix in repair new Air filter for 2.0 TR Split type AC complete all as specified and directed.
Supply and fix in repair of new filter drier for 2.0 TR Split type AC complete all as specified and directed.
Supply & replacement of remote suitable for 1.5 TR Split type AC capacity complete all as specified and directed.
Supply & replacement of remote suitable for 2.0 TR Split type AC capacity complete all as specified and directed.
M&L for repairs to remote mother board for 1/1.5 TR Split type AC capacity complete all as specified and directed.
M&L for repairs to remote mother board for 2/3 TR Split type AC capacity complete all as specified and directed.
Supply and fix in repairs harmatically sealed reciprocating compressor of capacity 1.5 Ton suitable for installed in Window type Air conditioner complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and fix in repairs harmatically sealed reciprocating compressor of capacity 1.5 Ton in exchange of unserviceable suitable for installed in 1.5 Ton Split type Air Conditioner complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of harmatically sealed reciprocating compressor (sealed unit) of capacity 2.0 Ton in exchange of unserviceable suitable for installed in 2.0 Ton Split type Air conditioner complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of harmatically sealed reciprocating compressor (sealed unit) of capacity 3.0 Ton in exchange of unserviceable suitable for installed in 3.0 Ton Split type Air conditioner complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of harmatically sealed reciprocating Compressor (Sealed unit) suitable for 150 Ltr. Water Cooler complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of harmatically sealed reciprocating Compressor (Sealed unit) suitable for 40/80 Ltr. Water Cooler complete all as specified and directed. Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of harmatically sealed reciprocating compressor (sealed unit) with relay suitable for refrigerator of capacity 310/315/320/325 litres complete all as specified and directed. Make of compressor TECUMESH / KIRLOSKAR / GODREJ)
All as per item No. 23 here-in-before above but for capacity of 180/230 ltrs capacity.
Supply and fix in repair Running capacitor 36 MFD 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS
All as per item No 13 above but capacity of 45 MFD 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS.
Supply and fix in repair Running capacitor 25 MFD 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS).
Supply and fix in repair Starting capacitor 60 to 80 MFD 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS.
Supply and fix in repair Capacitor 4 MFD, 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS.
Supply and fix in repair Capacitor 2.5 MFD, 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS.
Supply and fix in repair Starting capacitor 100 to 120 MFD 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS.
Supply and fixing of new running capacitor for 2 x 1.5 TR Split type AC complete all as specified and directed.
Supply and fix in repair of relay suitable for Window type AC 1.0/1.5/2.0 ton capacity complete all as specified and directed. Make : SRIRAM/Ranutrol.
All as per item No 33 above but split type A/C of capacity 1.5/2.0 TR complete all as specified and directed. Make : SRIRAM Model SR 1622 or equivalent of Ranutrol.
Supply and fix in repair over load relay suitable for Water cooler 40 to 60 ltr complete all as specified and directed.
Supply and fix in repair box type relay suitable for refrigerator 165 to 310 ltr capacity complete all as specified and directed. Make : SRIRAM / Ranutrol/ Indfoss.
Supply and fix in repair relay 30 Amps capacity suitable for 4/5 KVA stabilizer omplete all as specified and directed.
Supply and fix in repair of Thermostatic switch with knob suitable for window type AC 1.0/1.5/2.0 TR.(Make : INDFOS / RENUTRAL/Sriram)
Supply and fix in repair suction and discharge valve for 1.5/2.0 TR spilt type A/C complete all as specified and directed.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.0/1.5/2.0 TR Window type Air Conditioner of various makes as per sample.
Repairs to Blower/Fan motor for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of Fan motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner of various makes as per sample.
Supply and fix in repair Fan motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner of various makes as per sample.
Supply and fix in repair Fan Motor Single phase,230V for water cooler complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR split type Air Conditioner (indoor unit) complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 ton split type Air Conditioner (indoor unit) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of new fan blower for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and as directed by Engineer-in-Charge.
M & L for Rewinding of electric fan motor of 1.0/1.5/2.0 ton window type AC 1400 RPM 220 V 50 C/S with super enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
M & L Rewinding of electric fan motor of 1.5/2 ton split type AC (outdoor unit) 1400 RPM 220 V 50 C/S with supper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
Supply and fixing of new swing motor for split type AC 1.5/2.0 Ton capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair of front grill suitable for 1.0/1.5/2.0 ton window type Ac make Carrier Air con/Usha Sriram/LG compelete all as per site requirement and as per sample.
Supply and replacement of PCB suitable for 1.5/2 TR split type ACs as per site requirement and as per sample. Make : LG/Carrier/Blue star
All as per item No 13 above but for 3 TR split type ACs complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of contactor suitable for LG/Bluestar/Voltas/Carrier/Hitachi make Split type AC capacity 1.5/2.0 TR all as specified and directed.
Supply and replacement of evaporator coil for indoor unit of 1.5 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of condenser coil for outdoor unit of 1.5 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of evaporator coil for 2 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of condenser coil for outdoor unit of 2 TR Split AC complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of blower for indoor unit of Split AC 1.5/2 TR complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of fan blade suitable for out door unit of Split type AC capacity 1.5/2.0 as per sample complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of fan blade suitable for window type AC capacity 1.0/1.5/2.0 as per sample complete all as specified and as directed by Engineer-in-Charge.
M&L for disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
Supply, fixing, jointing and testing copper tubing with nominal dia meter of 0.25 inch of suitable thickness for liquid line to connecting out door condensing unit and fan coil unit complete all as specified and directed. (for 1.5/2.0 TR split AC).
Supply, fixing jointing and testing copper tubing with nominal dia meter of 0.5 inch and 0.8 inch thickness including expanded polythene foam insulation tubing for external insulation of suction line for connecting outdoor condensing unit and fan coil unit complete all as specified and directed (For 1.5/2.0 TR split AC).
Supply and fixing new Thermostat for water cooler storage type of capacity 30/40/60/120/150/180ltr/hour all as per sample.
Material and Labour for of base stand for fan motor from 2 mm thick MS sheet by welding and required nut bolts/washers as directed.
Supply and fix in repair Fan Motor blade complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Push type C.P. bib cock for water cooler complete all as specified and as directed by Engineer-in-Charge. Make : L & K/Leader
Supply and fix in repair float valve PVC for water coolers as per sample complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair water drain-out tray stainless-Steel of suitaible thickness for water cooler any make /size , with PVC waste pipe ,pipe clamp, complete as directed
Supply and Charging of Freon gas R-134/R-12 for Refrigerator/Water cooler and Deep Freezer complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Evaporator coil assembly for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of freezer door for refrigerator 165 to 310 Ltrs capacity complete all as specified and as directed by Engineer-in-Charge.
Supply and Charging of Freon gas R-22/R-410 for Acs complete all as specified and as directed by Engineer-in-Charge.
Supply and replacement of flexible Core PVC insulated with stranded copper conductor 2.5 Sqmm 4 core 600/1100 V ISI Marked complete all as specified and as directed by Engineer-in-Charge.
Supply and Replacement of PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Repairs to Voltage stabilizer of 1 KVA to 5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit board, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay all as directed.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA all as specified and as directed.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete suitable for 01/2 KVA all as specified and as directed
Supply and fixing in repair Suction/Discharge valve for 3 TR (2 x 1.5 TR) TR Split type AC.
Supply and fixing in repair new lamp for Deep Freezers 500 Ltrs
Supply and fixing in repair new lamp cover for Deep Freezers 500 Ltrs
Supply and fixing in repair new lamp switch for Deep Freezers 500 Ltrs
Material and labour for core cutting on stone wall/concrete wall for inserting of copper tube and flexible copper cable for fixing of outdoor unit and making good to the distrubed surfaces also matching with the existing surfaces all as specified and as directed.
Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and as directed by Engr-in-Charge.
M&L for sub-main wiring with two runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing capping of suitable size and fixing accesories should be concealed/fixed to wall/roof/floor and including suitable PVC cassing capping with 4 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/cassing Caping will be measured as one length. Three run of 4 Sq mm and PVC conduct/ Cassing caping is measured as one Run or one Meter.
Supply and fixing in repair MCB Single pole, 230 volts, 20 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
M&L for fix in replacement of PVC AC/ box with 20 Amp MCB DP , socket and plug top , PVC , 3 Way complete all as specifeid and directed. Make Havells Product code DHDBCDP025201603/ Legrand / Anchor or equivalent
S & F in replacement of SSC 15 Amp including PVC gang box fixing screw ISI marked. Make : Anchor/Legrand/HPL/Cona
Supply and fixing in replacement plug top 15 Amp white or ivory, ISI marked all as specified and directed. Make : Anchor/Legrand/HPL/Cona
Supply and fixing in repair MCB DP, 230 volts, 32 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Dismantling voltage stablizer including transformer copper wound , relays contact point, wiring with replacement of volt meter repair to transformer ,replacement of relays , assembling the complete and testing for capacity 2 KVA and input rating 135-290 Volts complete all as specified and directed . Make: Volina/ VGuard/Vintech
All as per item No. 93 above but 3 KVA.Make: Volina/ VGuard/Vintech
All as per item No. 93 above but 4 KVA.Make: Volina/ VGuard/Vintech
All as per item no. 93 above but 5 KVA.Make: Volina/ VGuard/Vintech
Attending day to day complaint to check serviceability of spare and taking down unsv parts and check mains continuity and loose connection including piece of wire complete .Note:- Rate for one job consists of upto 04 complaints per day . If complaints are more than 04 Nos , the same shall be measured as another job for the day.
Supply and fixing in replacement UPVC Pipe of size 80mm dia laid/ fix on wall with all accessories ( Such elbow , tee, socket , union , clamp ) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 50mm dia laid/ fix on wall with all accessories ( Such elbow , tee, socket , union , clamp ) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 32mm dia laid/ fix on wall with all accessories ( Such elbow , tee, socket , union , clamp ) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 20mm dia laid/ fix on wall with all accessories ( Such elbow , tee, socket , union , clamp ) complete all as specified and directed.
Supply and fixing in replacement of PVC tap suitable for 15mm dia pipe complete all as specified and directed.
Supply and fix in repair metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps, 'C' Curve, 10 KA rupturing capacity complete all as specified and directed by Engr in charge.
Note : (I) Contractor has to attend and rectify the complaint within 24 Hrs from time of occurance , if he fails to do so amount of rupees 500 per complaint will be charged from the contractor . (ii) Contractor has to deploy sufficient manpower for rectificaiton of complaint. (iii) Rep of contractor will take the complaint from MES Complaint cell daily and resubmit the complaint slip to MES Office / Concerned JE after rectificaiton.
SRINIDHI DIESELS & ELECTRICALS (BID ID -3303583)
UNIVERSAL ENGINEERING (BID ID -3303823)
devan enterprises (BID ID -3306925)
M/S SRI BALAJI ENTERPRISES (BID ID -3308870)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .