Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L1 | Accepted-AOC Awarded, L1 Bidder for Part- C |
| 2 | L1₹5.5 CrAccepted-AOC | ₹5.5 Cr | L1 | Accepted-AOC Awarded, L1 Bidder for Part- A |
| 3 | L1₹9.5 CrAccepted-AOC | ₹9.5 Cr | L1 | Accepted-AOC Awarded, L1 Bidder for Part- B and D |
| 4 | NA₹10.0 CrRejected-Finance | ₹10.0 Cr | NA | Rejected-Finance Not Qualified |
| 5 | NA₹12.5 CrRejected-Finance | ₹12.5 Cr | NA | Rejected-Finance Not Qualified |
| Sl No | Description | Qty | Unit | M/s. JYOTI SARUP MITTAL No Rank | ENTECK TRADE LINK No Rank | Sacheti Infratech Private Limited L1 | RGI ENTERPRISES No Rank | SANJIV SAHAI SHARMA No Rank | M/S JAI MAA CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Part II- STEEL STRUCTURAL WORKS | |||||||||
| 2.00 | Canopy in Structural Steel
Supply, fabrication, erection and handing over of structural steel fabricated canopy [steel structures tentative weight @ 85 Kg/Sqm] with 0.6mm thick Zincalume/galvalume colour coated steel sheets for roof sheeting as per specification, including 0.6mm thk. cold rolled colour coated steel profile sheet of Trac (150F) Pre-Coated Steel false ceiling system, with powder coated finishes as per manufacturers instruction and specification, facia, flashings, Rain Water Pipe, electrical cable pipe & Gutter, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site (Total DFT 120 microns). The work is to be completed in all respect as per technical specification of Canopy, scope of work, detailed construction drawings and directions of the Engineer-in-charge. (rectangular plan area shall be considered for measurement)
1. The tentative weight of structural steel shall be 85 kg/m2 (only weight of Steel structures elements excluding sheeting and false ceiling) of canopy area. A variation of +/- 15% of structural steel weight shall be deemed included in the item. Any increase/decrease beyond this limit shall attract payment/deduction @ Rs. 80000/- per Tonne.
2. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes, roof sheeting, flashing, fitting and fixtures, false ceiling system, gutter, rain water pipes, electrical cable pipe and bends, electrodes, edge colour coated sheets (for signage works), primer, paint and all consumables etc. with all bye works and sundry works complete in all respect.
3. Rate to exclude cost of electrical wiring for under lights and Signage works, supply & fixing of all electrical fixtures/materials, signage works & Civil Foundation. | 300 | SQM | 20,000 ₹60,00,000 | - | 11,500 ₹34,50,000 Lowest | 13,000 ₹39,00,000 | - | 18,000 ₹54,00,000 |
| 3.00 | Supply, fabrication & erection of Steel structure
Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, Cat Ladder, handrails, hoardings for signages, LCV stand, MS channel drain covers, column, rafter, purlins, runners, bracings, beam for monorail, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation, painting as per specification, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (The cost & weight of MS bolts and nuts (permanent and service), washers, electrodes, putty, gases, shims, packs, cost of straightening of raw materials, Built up section at any shape, cutting of flats from plates and providing splices, paints, tools, plants, testing of materials, etc and all other consumables as required for the work shall be deemed to be included in the quoted rates.) | 16,000 | KG | 140 ₹22,40,000 | - | 100 ₹16,00,000 Lowest | 100 ₹16,00,000 Lowest | - | 150 ₹24,00,000 |
| 4.00 | Supply and erection of Zincalume high tensile colour coated sheet on roof and sides:
Supply and erection of 0.5mm TCT zincalume high tensile colour coated steel sheets (fy=550MPa) conforming to IS:15961 having trapezoidal profile with a cover width of 930-1020 mm and 28-32 mm deep crest at pitch of 186-250mmc/c with minimum two ribs at centre for stiffening. with zincalume coating 150gsm. The sheet shall have a total coating thickness of 35 micron,super durable polyester colorbond XRW quality paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both side surface as per IS:15965. The paint system should have stable resin & inorganic pigments for paint durability and lead free for water harvesting The sheet shall have anti-capillary groove to avoid any seepage of water through lateral over lap, compatible flashing, Trims, ridge panel and fixtures, accessories, sealing tape etc., including transportation and delivery at site, storage and handling at site, cutting and bending of sheets to required shapes and sizes and erecting them on roof and sides using self-drilling, self-tapping fasteners which shall be hot dip galvanized with Xylon coated with EPDM Seals conforming to AS: 3566 class 3 at proper position. Roof sheet shall be laid in colours as per approved colours scheme. All works shall be completed in all respect as per specification, scope and description of works and as per direction of the Engineer-In-Charge. Mode of measurement shall be total covering area of sheeting. Lapping of sheets, ridges and flashes shall not be paid extra. (Only net laid area to be measured for payment) | 80 | SQM | 900 ₹72,000 Lowest | - | 1,500 ₹1,20,000 | 1,200 ₹96,000 | - | 1,500 ₹1,20,000 |
| 5.00 | Supply, fabrication & erection of MS Gate
Supply, fabrication and fixing in position steel entrance gate (as per the design shown in the tender drawing) supply of raw materials, transportation and delivery at site, unloading, storage and handling at site, site assembly and finally erection at appropriate locations. gates shall be fabricated out of channel and Sq Bar with all fixtures like MS Pivot, M.S sheet boxing ,locking arrangement, MS tower bolts, gate stopper, hold fast, MS wheel with ball bearing , MS tee bend to shape and embedded in the road surface for gate opening track , etc. including painting as per specification. The work is to be completed in all respect as per drawings and techanical specification and direction of the Engineer-in-Charge.
a) 5.5m clear opening width of gate in two panels | 2 | No. | 1,50,000 ₹3,00,000 | - | 60,000 ₹1,20,000 | 1,20,000 ₹2,40,000 | - | 25,000 ₹50,000 Lowest |
| 6.00 | Providing and Fixing Fencing Structure
Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over a two coat of primer in approved shade including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge.
a) Fencing height 2.1m | 55 | M | 3,800 ₹2,09,000 | - | 4,000 ₹2,20,000 | 3,300 ₹1,81,500 Lowest | - | 10,000 ₹5,50,000 |
| 7.00 | Providing and Fixing Fencing Gates
Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge.
a) 2m Wide x 2.1m High | 1 | No. | 50,000 ₹50,000 | - | 45,000 ₹45,000 | 65,000 ₹65,000 | - | 25,000 ₹25,000 Lowest |
| 8.00 | Providing and fixing chequered plate covers
Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge. | 1,900 | KG | 140 ₹2,66,000 | - | 100 ₹1,90,000 Lowest | 115 ₹2,18,500 | - | 200 ₹3,80,000 |
| 9.00 | Providing and fixing safety guard
Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe (size 600 deep and 500 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge. | 12 | No. | 3,000 ₹36,000 Lowest | - | 5,000 ₹60,000 | 6,750 ₹81,000 | - | 5,000 ₹60,000 |
| 10.00PART -III ( Fire Fighting Works) | |||||||||
Tender Value
Refer Docs
EMD Value
₹44.6 L
Closing Date
20 Feb 2025, 2:00 pmClosed
Sr. GM Contracts
Mecon Limited Delhi
CIVIL CONSTRUCTION WORK INCLUDING ELECTRICAL AND FIREFIGHTING WORKS FOR LNG STORAGE AND LNG DISPENSING FACILITIES
2025_GAIL_224483_1
05/51/E/0030/GAIL/001-iv-01
Open Tender
Miscellaneous Works
Works
540 days
Delhi
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹44.6 L
Yes
Online
21 Jan 2026
22 Jan 2025
21 Feb 2025
22 Jan 2025
20 Feb 2025
6 Feb 2025
29 Jan 2025
Amount
Part II- STEEL STRUCTURAL WORKS
Canopy in Structural Steel Supply, fabrication, erection and handing over of structural steel fabricated canopy [steel structures tentative weight @ 85 Kg/Sqm] with 0.6mm thick Zincalume/galvalume colour coated steel sheets for roof sheeting as per specification, including 0.6mm thk. cold rolled colour coated steel profile sheet of Trac (150F) Pre-Coated Steel false ceiling system, with powder coated finishes as per manufacturers instruction and specification, facia, flashings, Rain Water Pipe, electrical cable pipe & Gutter, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site (Total DFT 120 microns). The work is to be completed in all respect as per technical specification of Canopy, scope of work, detailed construction drawings and directions of the Engineer-in-charge. (rectangular plan area shall be considered for measurement) 1. The tentative weight of structural steel shall be 85 kg/m2 (only weight of Steel structures elements excluding sheeting and false ceiling) of canopy area. A variation of +/- 15% of structural steel weight shall be deemed included in the item. Any increase/decrease beyond this limit shall attract payment/deduction @ Rs. 80000/- per Tonne. 2. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes, roof sheeting, flashing, fitting and fixtures, false ceiling system, gutter, rain water pipes, electrical cable pipe and bends, electrodes, edge colour coated sheets (for signage works), primer, paint and all consumables etc. with all bye works and sundry works complete in all respect. 3. Rate to exclude cost of electrical wiring for under lights and Signage works, supply & fixing of all electrical fixtures/materials, signage works & Civil Foundation.
Supply, fabrication & erection of Steel structure Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, Cat Ladder, handrails, hoardings for signages, LCV stand, MS channel drain covers, column, rafter, purlins, runners, bracings, beam for monorail, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation, painting as per specification, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (The cost & weight of MS bolts and nuts (permanent and service), washers, electrodes, putty, gases, shims, packs, cost of straightening of raw materials, Built up section at any shape, cutting of flats from plates and providing splices, paints, tools, plants, testing of materials, etc and all other consumables as required for the work shall be deemed to be included in the quoted rates.)
Supply and erection of Zincalume high tensile colour coated sheet on roof and sides: Supply and erection of 0.5mm TCT zincalume high tensile colour coated steel sheets (fy=550MPa) conforming to IS:15961 having trapezoidal profile with a cover width of 930-1020 mm and 28-32 mm deep crest at pitch of 186-250mmc/c with minimum two ribs at centre for stiffening. with zincalume coating 150gsm. The sheet shall have a total coating thickness of 35 micron,super durable polyester colorbond XRW quality paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both side surface as per IS:15965. The paint system should have stable resin & inorganic pigments for paint durability and lead free for water harvesting The sheet shall have anti-capillary groove to avoid any seepage of water through lateral over lap, compatible flashing, Trims, ridge panel and fixtures, accessories, sealing tape etc., including transportation and delivery at site, storage and handling at site, cutting and bending of sheets to required shapes and sizes and erecting them on roof and sides using self-drilling, self-tapping fasteners which shall be hot dip galvanized with Xylon coated with EPDM Seals conforming to AS: 3566 class 3 at proper position. Roof sheet shall be laid in colours as per approved colours scheme. All works shall be completed in all respect as per specification, scope and description of works and as per direction of the Engineer-In-Charge. Mode of measurement shall be total covering area of sheeting. Lapping of sheets, ridges and flashes shall not be paid extra. (Only net laid area to be measured for payment)
Supply, fabrication & erection of MS Gate Supply, fabrication and fixing in position steel entrance gate (as per the design shown in the tender drawing) supply of raw materials, transportation and delivery at site, unloading, storage and handling at site, site assembly and finally erection at appropriate locations. gates shall be fabricated out of channel and Sq Bar with all fixtures like MS Pivot, M.S sheet boxing ,locking arrangement, MS tower bolts, gate stopper, hold fast, MS wheel with ball bearing , MS tee bend to shape and embedded in the road surface for gate opening track , etc. including painting as per specification. The work is to be completed in all respect as per drawings and techanical specification and direction of the Engineer-in-Charge. a) 5.5m clear opening width of gate in two panels
Providing and Fixing Fencing Structure Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over a two coat of primer in approved shade including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge. a) Fencing height 2.1m
Providing and Fixing Fencing Gates Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge. a) 2m Wide x 2.1m High
Providing and fixing chequered plate covers Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Providing and fixing safety guard Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe (size 600 deep and 500 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge.
PART -III ( Fire Fighting Works)
MECHANICAL WORKS
PLANT PIPING (ABOVEGROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, Flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Above Ground pipes: Receiving and taking over / handling of all supplied materials from Contractor's / Owner's designated place(s), transportation including loading, unloading, handling from Contractor's /Owner's designated place(s) to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except supply of those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading etc.; fabrication of fittings like miter bends, tees, reducers etc other than those in the scope of contractor and erection of the same, erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes; cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; surface preparation, primer, painting complete of pipeline with fittings as per MECON painting specification no. MEC/S/05/21/07, Painting to be done by spray only, clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Supply of paints, solvents and primers , preparation of surfaces by sand/grit blasting using one of the abrasives and application of Zinc Ethyl Silicate Primer (P1- One coat @ 75 microns DFT / coat), Two pack epoxy – polyamid mio Intermediate / undercoat paint (U1- One coat @ 100 microns DFT/coat minimum) and Two pack aliphatic acrylic polyurethane finish paint ( F2-Two Coats @ 40 microns DFT /coat minimum) suitable for normal corrosive painting environment as defined in contract document. Identification, lettering/ numbering, colour coding and colour bands as per Industry Quality Control manual etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings,Standards and instruction of Engineer-in-Charge. Painting shall be done by spray only.
10 INCH, IS: 3589,Thk.-7.1 mm
8 INCH, IS: 3589,Thk.-6.3 mm
6 INCH, IS: 1239,Thk.- Heavy
4 INCH, IS: 1239,Thk.- Heavy
3 INCH, IS: 1239,Thk.- Heavy
2 INCH, IS: 1239,Thk.- Heavy
1 INCH, IS: 1239,Thk.- Heavy
3/4 INCH, IS: 1239,Thk.- Heavy
PLANT PIPING (UNDER GROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, WRAPPING & COATING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications indicated in scope of work indicated in SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Under Ground pipes: Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all under ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading /tapping etc.,; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes;
Cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Job also includes trenching to all types of soil to specified depth, laying the already wrapped and coated pipes, back filling the trenches with available approved soil and also laying the pipes through hume pipes/culverts. Cost of wrapping as per IS: 10221 to be included in the cost including supply of wrapping materials. Cost of supply of hume pipes for road crossing also to be included.
8 INCH, IS: 3589,Thk.-6.3 mm,A33A,
6 INCH, IS: 1239,Thk.- Heavy, A33A
4 INCH, IS: 1239,Thk.- Heavy, A33A
SUPPLY AND ERECTION OF VALVES Complete work of supply & erection of valves including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, supply and erection of matching companion flanges, gaskets, fasteners, nuts & studs, etc. but not limited to, the following items in accordance with relevant specifications indicated in scope of work, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation of all types of valve by bolting, threading or welding,including supply of gaskets, nuts & studs, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valves wherever requried.
Gate Valves as per details below:
Size - 8 INCH, Rating - 150
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Tripple Offset Butterfly Valves as per details below:
Size - 6 INCH, Rating - 150
Size - 4 INCH, Rating - 150
Ball Valves as per details below:
Size - 2 INCH, Rating - 150
Size - 1 INCH, Rating - 150
Size - 3/4 INCH, Rating - 150
Size - 1/2 INCH, Rating - 150
Non Return Valves as per details below
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Pressure Safety Valve (Max pressure=10 kg/cm2)
Size - 6 INCH, Rating - 150
Expansion Bellow as per details below:-
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
SUPPLY & ERECTION OF Y /T TYPE STRAINER Design, Engineering, Manufacturing, Testing, Inspection, supply & erection including Packaging, Forwarding, Transportation, supply and erection of matching companion flanges, gaskets, fasteners, nuts & Stud , etc. to store of "Y / T" type strainer with cast Steel body & SS strainer as per approved Drg.,/ Data Sheet/ PJS etc but not limited to, the following in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT as per details below. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of "Y / T" type strainer with cast Steel body & SS strainer by bolting, threading or welding,including supply of gaskets, nuts & bolts, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks,pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried as per details below.
4" T/Y Type Strainer - 150#
HYDRANT SYSTEM Complete work of supply & erection including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, gaskets, fasteners, nuts & bolts, etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
Supply & Erection of stand post type hydrant with single outlet 3" inlet bronze landing valve (conforming to IS : 5290 : 1993 ) with matching flanges (Conforming to IS : 6392 Table-17 / ANSI B 16.5), with control fitted with 63 mm dia instantaneous female coupling on the outlet complete with orifice flange as required for network pressure ranging from 9 to 10.5 Kg/cm2, blank cap and chain. bolts, nuts and gaskets, etc., complete as per data sheet & technical specification . (1 set consists of 1 no. of single valves with stand post & matching flange, gaskets, nut & bolt all complete). The assembly shall be suitable for direct erection over companion flange on branch outlet from main header. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts, etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of 1750 LPM stand post type water cum foam monitor (UL Listed / FM Approved) as per Data sheet & Technical Specification with jet / spray nozzle with drain provision and all other accessories including suitable orifice plate for network pressure ranging from 8 to 10.5 Kg/cm2 and matching flanges of 4" size confirming to IS: 6392 Table - 17, bolts, nuts and gaskets complete including painting as specified & directed by EIC. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of FRP fire hose cabinet suitable for accommodating 2 nos of 15 mtrs long canvas hose with coupling, branch pipe and nozzle for external hydrants with double glass door, lock & key including outdoor mounting arrangement complete as specified. Necessary hangers and brackets for hose, nozzle and branch pipe or universal branch pipe to be provided within the cabinet. Provision for putting key of the cabinet shall also be provided.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection of FRP fire hose cabinet including supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply of 63 mm dia 15 m long RRL Hose including gunmetal male and female instanteneous type coupling , machine wound with GI wire complete in all respects. Hose to IS:636 type A, UL Listed / FM Approved and coupling to IS:903:1984 with ISI certification. (One set consists of 2 nos each of 15m length)
Supply of Jet Nozzle with branch pipe ( IS 903)
4 way Fire Brigade Inlet
HIGH EXPANSION FOAM GENERATORS
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Fixed Type) with by-pass system along with inlet coupling & pressure gauge, Fixed Inline foam Inductor ,Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification .
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Portable Type) along with by-pass system inlet coupling, portable type Inline Foam Inductor, Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification.
SUPPLY & ERECTION OF ITEMS/COMPONENTS RELATED TO FIXED FOAM SYSTEM
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 200/210 ltr HDPE barrels.
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 1000 ltr HDPE Tote. The outer frame shall be Rigid welded hot dipped galvanized tubular steel cage. Bottom plate shall be galvanized steel base shaped for inner container support and stability.
ROTATING EQUIPMENT WORKS - MECHANICAL WORKS (SUPPLY & ERECTION)
DIESEL ENGINE DRIVEN FIRE MAIN PUMP
Design, Engineering, Manufacturing, Supply, Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at Neemrana elaborated in tender and elsewhere) of Diesel engine driven Vertical Turbine single outlet pumping set with bronze impeller with C.I. Body and pump accessories complete and connected by a flexible coupling to a water cooled diesel engine (Conforming to IS : 10002) mounted on a common structural base plate with anti- vibration pads and foundation complete with AMF panel, battery (including one spare battery) battery charging, cooling system, fuel tank, fuel system, automatic starting arrangement, exhaust pipe of required length to discharge at suitable height with muffler to meet latest environmental norms, day oil tank (storage of 8 hrs. running capacity) mounted on suitable structural supports, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, common base plate, flexible coupling, coupling guard, power and control cable, consumables, compulsory erection & commissioning spares, first fill of lubricants, fuels, Special Tools Tackles etc., Configuration, Interfacing, erection at site, Integrated Testing & Commissioning as per Job specifications and Special Instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr. Head : 80 mwc Engine BHP : Suitable size to be furnished by the bidder with sizing calculation.
ELECTRICAL MOTOR DRIVEN MAIN FIRE PUMP.
Design, Engineering, Manufacturing, Supply , Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at at various locations of IGL sites elaborated in tender and elsewhere) of Electirc motor driven Vertical Turbine single outlet pumping set including electric motor, Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr Head : 80 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
ELECTRIC MOTOR JOCKEY PUMP
Design, Engineering, Manufacturing, Supply and commissioning (including packaging and forwarding, insurance, handling and unloading at various locations of IGL sites elaborated in tender and elsewhere) of Vertical Turbine Jockey pump. including electric motor,VFD (Varaiable frequency drive ), Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The Jockey pump shall be started and stopped automatically through pressure transmitter. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Fire Jockey Pump Capacity of Pump : 10 m3/hr Head : 88 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
NOTES: 1. Price for Erection and Commissioning spares (As per Vendor’s recommendation) is to be included in the above mentioned SOR Items of Pumps. 2. Bidder shall also furnish details of special tools and tackles considered by them. Rates for all these items shall be included in the quoted rates for Pumps and shall not be paid separately. 3. The Vendor shall be completely responsible for the design, materials, manufacture & fabrication, testing, inspection, preparation for shipment,transport of the above equipment, erection, testing & commissioning strictly in accordance with the SOR and all attachment thereto. All items shall be provided with test certificates. 4. Inspection shall also be performed by Owner’s delegate, as set out and specified in the codes and particular documents forming part of this SOR
Supply, fabrication and erection of steel Structures for Crossovers & Structural works in & around Fire Water Pump House
Prepartion of fabrication drawings including bill of materials, getting approval from consultant including supply of raw materials, fabrication of steel structures such as columns, column bracings, roof girder/truss, roof bracings, struts, roof purlins, side girts, sag angles/rods, monorail beams, stair cases, ladders, crossover,valve operting platforms, handrailing, pipe supports, gratings, chequred plate, etc to complete the terminal work including surface preparation by sand blasting confirming to Swedish Standard SA 2½ for painting, supply and application of 1st coat of Inorganic Zinc Silicate 75 microns DFT , 2nd coat of Intermediate of Epoxy High Build Micaceous Iron Oxide(MIO) 100 microns DFT, 3rd coat Finishing paint of Acrylic Polyurethane 40 microns DFT and 4th coat Finishing Paint of Acrylic Polyurethane 40 microns DFT(Total DFT=255 microns minimum) of approved colour .Finishing coat shall be applied one before erection and one coat after erection, including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension.The work shall be completed in all respect as per drawings ,technical specification and direction of the Engineer-in-Charge.
Design, Engineering, Manufacturing, Testing, Inspection, Supply, erection testing & commissioning including Packaging, Forwarding, Transportation to store of Monorail with Guided Chain pulley block & Trolley of 5T capacity as per approved Drg.,/ Data Sheet/ PJS etc in accordance with relevant specifications indicated in PJS, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
INSTRUMENTATION WORKS (FOR FIRE PROTECTION SYSTEM) Complete Instrumentation work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), FRLS cables, Ex-proof JBs, Ex-proof glands,Pressure Guages,Pressure Transmiiters, Pressure Switches,Level Transmitters, SOVs. cable tray, U/G cable trench, canopies, earthing wire/ strip, logic / graphics development / modification as per site requirement in the PLC (common for plant & fire fighting system), etc. as per site requirement.
ELECTRICAL WORKS (FOR FIRE PROTECTION SYSTEM) Complete Electrical work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), cables, LT Panel, Ex-proof glands, cable tray, U/G cable trench, canopies, earthing wire/ strip etc. as per site requirement to complete the project in all respect.
FIRE ALARM & CLEAN AGENT SYSTEM
DESIGN, ENGINEERING, SUPPLY, HANDLING, TRANSPORTATION, INSTALLATION, TESTING & COMMISSIONING OF HIGH PRESSURE CLEAN AGENT (INERT GAS) FIRE SUPPRESSION SYSTEM Clean Gas Fire Suppression Centralised System (Inert Gas High Pressure) complete with required accessories with main and standby bank of cylinders & each cylinder filled with Clean agent Fire extinguishing Agent (Inert Gas) as Main Bank and Standby Bank (As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved) with Pressure Switch & Locking Device, Discharge Nozzles designed to provide the proper flow rate and distribution of Clean Agent to total flood the hazard area: 180 deg. / 360 deg. ( As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved ), ASTM A106 Gr. B Piping, fittings & supports, etc. , Manifold fabricated from seamless pipe, A106 Gr. B having inlets with supports etc. with activation through intelligent addressable Fire Detection and Alarm System panels after receiving signals from detectors, response indicators etc. all complete supply as per approved scheme & Tender and instructions of Engineer-in-charge. The bidder shall include mandatory spares as described in PJS along with recommended list of spares required for 2 years trouble free operation. Inert gas shall be used as Clean Gas Agent. Complete work of supply, installation, testing, commissioning includes Handling including lifting and transportation from Owner's / Contractor's own storage yard to work site and inspection charges, installation, testing, commissioning & handing over in accordance with relevant Specifications & relevant Data Sheets indicated in PJS, scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. The areas of rooms to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h) and Battery room of size 2.5 m X 2 m X 4 m (h
Note - 1. Design shall be done based on largest room size with provision to discharge gas in affected room through directional valves including Room void, Ceiling Void & Floor void/ Cable trenches. Balancing of gas discharge in rooms shall be done keeping in NOAEL level as per NFPA2001.
DESIGN, ENGINEERING, SUPPLY, ERECTION, TESTING & COMMISSIONING OF FIRE DETECTION & ALARM SYSTEM FOR CONTROL ROOM BUILDING Intelligent addressable Fire Detection and Alarm System with fire alarm cum gas release panels which will also have provision to receive signals from LHD system in cable trenches, detectors, response indicators, cabling , cable trays, manual gas release switch , manual gas abort switch, hooter with flasher, manual call points etc. all complete as per approved scheme & enclosed drawings. Work shall be carried out as per direction of EIC. Manual call points shall be installed at strategic operating locations. Provision of AC / Exhaust Tripping alongwith supply of cables, relays, glands etc. also be considred under this scope. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of FIRE DETECTION & ALARM SYSTEM including performance testing of the system, painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever required. The area of control room buildings to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h), Battery room of size 2.5 m X 2 m X 4 m (h) and office room of size 4 m X 3.2 m X 4 m (h)
Note: Fire Alarm Panel & Gas Release Panel shall have provision to work on 230 V AC / 24VDC (Input Power supply ) as per availabilty of Input power at Stations.
MANUAL CALL POINTS Complete work of Design, Engineering, Supply, Handling, Transportation, Installation, Testing & Commissioning of Exproof & IP 67 Manual Call Points. The MCP shall be break Glass Type in Red Colour and are located at the following locations in the LCNG Terminal Area: (i) Security room,(ii) Loading /unloading Pump area, (iii) Truck Unloading area (iv) Outside the Dyke area towards LCNG storage tank. These manual call points shall be hard wired to PLC.The scope of work also includes supply,inspection,laying,termination & testing of required quantities of cable as per MCP location along with necessary hardware or other accessories required to enhance the functionality,operation of the complete system.
SUPPLY OF SAFETY EQUIPMENTS & HAND APPLIANCES
DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER (STORED PRESSURE TYPE) Supply & Installation of Dry Chemical Powder type fire extinguisher as per IS: 15683-2006 & MECON TS no. MEC/TS/05/28/081/26 suitable for inverted operation with anticorrosive treatment and hydraulically tested to a pressure of 25 kg/ sq.cm . Extinguishers externally painted with red enamel and fixed to wall with brackets complete with internal charge and spanner complete. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
4 Kg Capacity
9 Kg Capacity
25 Kg Capacity (Trolley mounted)
CO2 TYPE FIRE EXTINGUISHERS Supply & Installation of CO2 type fire extinguishers with steel cylinder with dischange valve as per MECON TS no. MEC/TS/05/28/081/25 and conforming to IS:15683. Extinguisher shall be painted with red enamel paint. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 4.5 kg.
MECHANICAL FOAM TYPE FIRE EXTINGUISHER Supply & Installation of Portable fire extinguisher mechanical form (Gas cartridge) type of 9 litres capacity with initial charge manufactured as per IS 15683 with ISI mark.The refills shall be manufactured as per IS 4989 (Part-II)- 1984 with ISI marked. The cartridge shall be manufactured as per IS:4947- 1985 with ISI mark. The extinguisher will be painted with fire red colour and will be provided with all accessories, wall mounting brackets and screws. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 9 Ltr
FIRE BUCKETS Supply and installation of galvenised steel set of 4 fire buckets (9 Ltrs. Cap) as per technical specification no. MEC/TS/05/28/081/03 and confirming to IS: 2546-1974 RA2000.Buckets shall be painted with red enamel paint and fixed to suitable location . Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
EYE WASH SHOWER (STAINLESS STEEL) Complete work of supply & installation including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, of Eye Wash shower pedestal mounted along with supply & laying of required GI Heavy Pipes, fittings Isolation valves , etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Supply & laying of GI Pipe (Heavy Grade ) of Size (25 NB) minimum,Fittings,isolation valves for water connection to the Eye Wash Shower (Near Odorising Skid) from the avaialable nearest tapping point of Portable water are deemed to be included in the quoted price.
SUPPLY OF SAFETY EQUIPMENT Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Goggles for Eye Protection from LNG Spray
Protective Apron for cryogenic liquid handling
Safety Helmet with IGL Logo - IS-2925-1984 RA2000
Gumboots for protection during LNG Spillage
Stretcher with blanket- IS-4037-1967 RA-2001.
First Aid Box
Supply,Installation,Testing and Commissioining of Electrical Siren (1 Km Diametrical range) & Interfacing with Fire Alarm Panel/Gas Release Panel
Hand operated siren (1 Km Diametrical range) IS-6194-1971 RA- 2006
Portable Gas Detectors / Explosive meter
Wind Shock
PART IV: Architectural Works
PYLON (Monolith Tower)
1.5 m X 5 m, located midway between ingress and egress.
Supplying & Installing Monolith as per approved design by RSGL/MECON. The item is lump sum and shall include all relevant costs associated with putting up such facility including supply, fabrication, erection, assembly, commissioning the MONOLITH (with client's name & logo) including electrical cabling and lighting etc. for the same. The specifications are as follows: • Made out of MS hollow pipe framework (hollow steel sections as per design requirement) with epoxy primer and paint. • Structure covered with PVDF coated 4 mm thick ACM (Alstrong/ Aludecor/ Alucobond) sheet cladding duly by cold forming, CNC machine routed and fold with retro reflective graphics and vinyl for backlit purpose. • ACM shall have a Total Thickness of 4mm : Top Coil 0.5mm ( 3003/3105 Grade as per IS - 737 1986 with minimum 25 microns PVdF Coating on top coil and Polyester / Epoxy coating on Back Coil ( 4 -7 microns PVDF ACM in colour and shape as per approved design. ACM to be cut in shapes as indicated. • COMPANY LOGO: 770mm in ht. & 50mm projected Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night with LED lights (Osram / Neenja / equ.) with necessary electrical fittings. • LNG LOGO: 440mm in ht. & 50 mm projected Acrylic / PETG thermoformed letters(as letters(as per art work) covered covered with vinyl of approved make with the provisions of illuminations during night.
• Cut Retro reflective vinyl (Avery / 3M / equ.) on ACM top to be paste as per artwork and fixed as per the details on both sides with provision of the LED numbers for rate indication. • Retro Reflective Sheeting shall be Type XI DG3 Microprismetice as per ASTM D 4956-09 in required colour & Size on both sides and cutouts for product names, logos, etc. duly CNC Plotted. • Special spot lights (2 nos.- 400 watts with metal halide lights of Philips make) to be incorporated in design to light up the entire tower with throw from base. • The backlit portion of the monolith to be lit with sufficient numbers T5 (28 W) tube lights (Philips make) with electronic choke, mounted on MS tube frames with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • Steel structural frame to be installed on RCC foundations. Top and exposed sides of the foundation to be cladded in 18 mm thick black polished granite. • All work to be done in line, level and plumb, all complete with by works, as approved.
CANOPY FASCIA:
800 mm wide (in corporate colours on canopy vertical faces.
Supplying & Installing Canopy Fascia with following specifications: • 900 mm height canopy fascia with PVDF coated 4 mm thick ACM sheet cladding duly CNC machine machine routed and fold as per drawing mounted on 150 mm depth box made out of 25 mm x 25 mm MS hollow pipe frame with powder coating and top GI sheet cover. • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice duly pasted on ACM in required size & shape (colour scheme and design to be approved) on mild steel framework with part backlit for company logo and name. • LED Lighting modules or encased LED light strips (Osram / Neenja / equ.) and power supply. • The letters sh all be in 30 mm thick Acrylic/ PC duly CNC Routed in require shape & Size as per direction of concerned engineer. • Structural frame to be welded rigidly/ Bolted to the structural member of existing canopy structures. • FASCIA BAND: 300mm in ht. Acrylic / PETG thermoformed band with necessary support covered with vinyl of approved make with the provisions of illuminations during night with LED of approved make. • COMPANY LOGO: 900mm in ht. Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on all 4 sides.
• Company Name: 450mm in ht. 040 white Acrylic / PETG thermoformed letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on front right as per DWG. • Canopy fascia to be made in 12 m. (min.) long straight panels factory plan/processed at converters factory and assembled/installed at site. Corner piece (1 metre both sides) on both sides (as required), also to be factory plan/processed/assembled and installed at site. Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb. • Backlit section of the fascia shall be of 4 meters length and one/ two logos (depending on design) and shall have sufficient number of LED/T5 (28 W) tube light with electronic chokes mounted with plastic holders to structural frame. • The top of the fascia shall have 4 mm thick ACM with hinged GI service door in backlit part. The back of the fascia to have 18 gauge GI sheets. • Multi-strand copper conductors with PVC insulation to be used. • The bottom and top of the fascia shall have a white ACM trim to cover the gap between the canopy and fascia. • The contractor should make suitable fixing arrangement, which should be duly vetted by a certified structural engineer as per the actual dimensions of the canopy structure.
CANOPY COLUMN CLADDING
Supplying & Installing Column Cladding: • Using PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond), mounted on box made out of 20 mm x 20 mm MS square pipe hollow section with powder coating. • Backlit design band in the centre in PET G (Eastman / Bayer / equ.) with yellow vinyl, LED lighting modules (Osram / Neenja / equ.) and power supply according to the design. • The structural framework shall be fixed securely to existing canopy column by welding at site. • ACM panel fixing to ensure consistent joint gaps and panel size. • All grooves shall be sealed with sealant material of approved colour, all complete with by works, as approved.
SAFETY SIGN
200 mm X 200 mm
Supplying & Installing safety sign stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on column cladding.
DISPENSER STICKER
Supplying & Installing stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on dispensers.
SPREADER
450 mm X 450 mm
Supplying & Installing Pump Spreader: • Made of 25 mm x 25 mm MS hollow pipe frame box with powder coating & cladding on both sides of PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond) • CNC Router cut graphics in 040 white acrylic with LED modules (Osram / Neenja / equ.) for lighting • Spreader frame to be fixed securely to canopy columns with box & cap arrangement. • Sufficient no. of LED/ CFL lights and electronic chokes fixed with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • AII work to be done in line, level and plumb, all complete with by works, as approved.
CRASH GUARD
Supplying & Installing 80mm dia MS pipe or as per design with two coat of zinc oxide primer and metallic paint as per the design.
BUILDING FASCIA
700 mm wide on top of building faces in elevation.
Supplying & Installing Building Fascia with following specifications: • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape (colour scheme to be approved) on mild steel framework. • Structural frame to be fasteners/ Nut Bolted to the building walls with dash fasteners and leveling 'arrangement. • Building fascia to be made in maximum length of straight panels (with minimum no. of joints) straight panels factory plan/processed at converters factory and assembled/installed at site. • Corner piece (1 metre both sides) on both sides, also to be factory plan/processed/assembled and installed at site. • Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb, all complete with by works, as approved.
MANDATORY SIGN
300X 450mm (on toilets) & 300X 600mm (in compressor and LCV area) - rectangular or trapezoidal in shape.
Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved.
DIRECTION SIGN
400 mm X 1000 mm height
Supplying & Installing Entry-Exit sign: • Made out of 25 mm x 25 mm MS hollow pipe frame box with powder coating and covered with 4 mm thick ACM sheet (Alstrong/ Aludecor/ Alucobond) and CNC router cut graphics in 040 white acrylicwith LED modules (Osram / Neenja / equ.) for lighting and base foundation. • The sign frame to be fixed securely to CC foundation. • The CC foundation shall have 8mm thick polished black granite tiles cladding on top and all exposed side surfaces. • All work to be done in line, level and plumb, all complete with by works, as approved.
HOARDING
3000 mm wide
Supplying and installing Printed Flex sheet (make LG / 3M / Avery) with approved Art work (suitable for front lit) to be Fitted to the steel sheet of existing Hoarding structure in aluminium frame using Klick Rail System & as per direction of concerned Engineer/ client.
SPOT HALOGEN LIGHTS
At an interval of 2 m C/C on top of existing steel hoarding.
Supplying and installing Spot halogen lights (150 watts of Philips make) at an interval of 2 m center to center on top of existing hoarding including supply with steel bracket and laying of cable upto electrical panel of Electrical room (in Utility building) complete in all respect.
Part -V (ELECTRICAL Supply)
A. Supply
415 V LT PDB and APFC Panel
Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification.
LIGHTING DISTRIBUTION BOARDS
Design, engineering, manufacture, shop testing,supply, 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp.
INVERTER SYSTEM
Supply including packing and forwarding, transportation, delivery at storage of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Design, engineering, manufacture, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :
Supply of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring , test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Design, engineering, shop testing, Supply , packing and forwarding, transportation, delivery at storage and from storage to site lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Design, engineering, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Supply of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Supply of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Supply of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Supply and Fabrication of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Supply of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Supply of Main Distribution Frame - 12 pair
Supply of LAN switch with single incomer and min 10-port out going port complete in all respect.
Supply of required material for Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Supply including packing and forwarding, transportation, delivery at storage to site of 11 kv/433 V outdoor type, 3Ph, 50Hz,copper wound, Dyn11, ONAN distribution transformer with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Supply of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating, pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
Supply, of 11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Supply of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
Supply of Tools and Instrument as per Annexure - A of scope of work.
Flame Proof Tool Box Set as per Annexure - A of scope of work.
B. Erection, Testing & Commissioning
415 V LT PDB and APFC Panel
Erection, testing & Commissioning of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification.
LIGHTING DISTRIBUTION BOARDS
Erection, testing & Commissioning of 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp.
INVERTER SYSTEM
Erection, testing & Commissioning of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Erection, testing & Commissioning of following :
Laying of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Erection, testing & Commissioning of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Erection, testing & Commissioning of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Erection, testing & Commissioning of latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Erection, testing & Commissioning of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Erection, testing & Commissioning of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, installation of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Erection, testing & Commissioning of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Installation of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, installation of necessary anchor bolts and grouting etc, applying one coat of anti rust primer, two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Installation of the following including the necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Laying of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Erection, testing & Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Erection, testing & Commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Installation of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Erection, testing & Commissioning of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Erection, testing & Commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Laying of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Laying of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Erection, testing & Commissioning of Main Distribution Frame - 12 pair
Erection, testing & Commissioning of LAN switch with single incomer and min 10-port out going port complete in all respect.
Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Erection, testing & Commissioning of 11 kv/433 V outdoor type, 3Ph, 50Hz, copper wound, Dyn11, ONAN distribution transformer r with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Erection, testing & Commissioning of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB std.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Erection, testing & Commissioning of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for LNG station. However the official fees towards the approvals shall be reimbursed by the client.
Kindly quote in Percentage in M column on total Estimate Amount of Percentage part (Civil Work SOR Part -A (item CIV-01 to CIV -48) refer sheet -1. Note: Bidders shall quote percentage in plus ( '+ ') or minus (' - ') in column M by which total estimated price in the Sheet1 shall be increased or decreased to arrive at bidder‘s quoted price (excluding GST) for Sheet1. Bidder's quoted item rates shall be arrived by applying offered percentage on estimated rates of all BoQ items given in Sheet1.
Description of Work / Item(s)
Amount
Part II- STEEL STRUCTURAL WORKS
Canopy in Structural Steel Supply, fabrication, erection and handing over of structural steel fabricated canopy [steel structures tentative weight @ 85 Kg/Sqm] with 0.6mm thick Zincalume/galvalume colour coated steel sheets for roof sheeting as per specification, including 0.6mm thk. cold rolled colour coated steel profile sheet of Trac (150F) Pre-Coated Steel false ceiling system, with powder coated finishes as per manufacturers instruction and specification, facia, flashings, Rain Water Pipe, electrical cable pipe & Gutter, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site (Total DFT 120 microns). The work is to be completed in all respect as per technical specification of Canopy, scope of work, detailed construction drawings and directions of the Engineer-in-charge. (rectangular plan area shall be considered for measurement) 1. The tentative weight of structural steel shall be 85 kg/m2 (only weight of Steel structures elements excluding sheeting and false ceiling) of canopy area. A variation of +/- 15% of structural steel weight shall be deemed included in the item. Any increase/decrease beyond this limit shall attract payment/deduction @ Rs. 80000/- per Tonne. 2. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes, roof sheeting, flashing, fitting and fixtures, false ceiling system, gutter, rain water pipes, electrical cable pipe and bends, electrodes, edge colour coated sheets (for signage works), primer, paint and all consumables etc. with all bye works and sundry works complete in all respect. 3. Rate to exclude cost of electrical wiring for under lights and Signage works, supply & fixing of all electrical fixtures/materials, signage works & Civil Foundation.
Supply, fabrication & erection of Steel structure Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, Cat Ladder, handrails, hoardings for signages, LCV stand, MS channel drain covers, column, rafter, purlins, runners, bracings, beam for monorail, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation, painting as per specification, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (The cost & weight of MS bolts and nuts (permanent and service), washers, electrodes, putty, gases, shims, packs, cost of straightening of raw materials, Built up section at any shape, cutting of flats from plates and providing splices, paints, tools, plants, testing of materials, etc and all other consumables as required for the work shall be deemed to be included in the quoted rates.)
Supply and erection of Zincalume high tensile colour coated sheet on roof and sides: Supply and erection of 0.5mm TCT zincalume high tensile colour coated steel sheets (fy=550MPa) conforming to IS:15961 having trapezoidal profile with a cover width of 930-1020 mm and 28-32 mm deep crest at pitch of 186-250mmc/c with minimum two ribs at centre for stiffening. with zincalume coating 150gsm. The sheet shall have a total coating thickness of 35 micron,super durable polyester colorbond XRW quality paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both side surface as per IS:15965. The paint system should have stable resin & inorganic pigments for paint durability and lead free for water harvesting The sheet shall have anti-capillary groove to avoid any seepage of water through lateral over lap, compatible flashing, Trims, ridge panel and fixtures, accessories, sealing tape etc., including transportation and delivery at site, storage and handling at site, cutting and bending of sheets to required shapes and sizes and erecting them on roof and sides using self-drilling, self-tapping fasteners which shall be hot dip galvanized with Xylon coated with EPDM Seals conforming to AS: 3566 class 3 at proper position. Roof sheet shall be laid in colours as per approved colours scheme. All works shall be completed in all respect as per specification, scope and description of works and as per direction of the Engineer-In-Charge. Mode of measurement shall be total covering area of sheeting. Lapping of sheets, ridges and flashes shall not be paid extra. (Only net laid area to be measured for payment)
Supply, fabrication & erection of MS Gate Supply, fabrication and fixing in position steel entrance gate (as per the design shown in the tender drawing) supply of raw materials, transportation and delivery at site, unloading, storage and handling at site, site assembly and finally erection at appropriate locations. gates shall be fabricated out of channel and Sq Bar with all fixtures like MS Pivot, M.S sheet boxing ,locking arrangement, MS tower bolts, gate stopper, hold fast, MS wheel with ball bearing , MS tee bend to shape and embedded in the road surface for gate opening track , etc. including painting as per specification. The work is to be completed in all respect as per drawings and techanical specification and direction of the Engineer-in-Charge. a) 5.5m clear opening width of gate in two panels
Providing and Fixing Fencing Structure Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over a two coat of primer in approved shade including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge. a) Fencing height 2.1m
Providing and Fixing Fencing Gates Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge. a) 2m Wide x 2.1m High
Providing and fixing chequered plate covers Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Providing and fixing safety guard Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe (size 600 deep and 500 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge.
Part III- Fire Protection System
PLANT PIPING (ABOVEGROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, Flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Above Ground pipes: Receiving and taking over / handling of all supplied materials from Contractor's / Owner's designated place(s), transportation including loading, unloading, handling from Contractor's /Owner's designated place(s) to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except supply of those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading etc.; fabrication of fittings like miter bends, tees, reducers etc other than those in the scope of contractor and erection of the same, erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes; cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; surface preparation, primer, painting complete of pipeline with fittings as per MECON painting specification no. MEC/S/05/21/07, Painting to be done by spray only, clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Supply of paints, solvents and primers , preparation of surfaces by sand/grit blasting using one of the abrasives and application of Zinc Ethyl Silicate Primer (P1- One coat @ 75 microns DFT / coat), Two pack epoxy – polyamid mio Intermediate / undercoat paint (U1- One coat @ 100 microns DFT/coat minimum) and Two pack aliphatic acrylic polyurethane finish paint ( F2-Two Coats @ 40 microns DFT /coat minimum) suitable for normal corrosive painting environment as defined in contract document. Identification, lettering/ numbering, colour coding and colour bands as per Industry Quality Control manual etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings,Standards and instruction of Engineer-in-Charge. Painting shall be done by spray only.
10 INCH, IS: 3589,Thk.-7.1 mm
8 INCH, IS: 3589,Thk.-6.3 mm
6 INCH, IS: 1239,Thk.- Heavy
4 INCH, IS: 1239,Thk.- Heavy
3 INCH, IS: 1239,Thk.- Heavy
2 INCH, IS: 1239,Thk.- Heavy
1 INCH, IS: 1239,Thk.- Heavy
3/4 INCH, IS: 1239,Thk.- Heavy
PLANT PIPING (UNDER GROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, WRAPPING & COATING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications indicated in scope of work indicated in SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Under Ground pipes: Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all under ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading /tapping etc.,; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes;
Cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Job also includes trenching to all types of soil to specified depth, laying the already wrapped and coated pipes, back filling the trenches with available approved soil and also laying the pipes through hume pipes/culverts. Cost of wrapping as per IS: 10221 to be included in the cost including supply of wrapping materials. Cost of supply of hume pipes for road crossing also to be included.
8 INCH, IS: 3589,Thk.-6.3 mm,A33A,
6 INCH, IS: 1239,Thk.- Heavy, A33A
4 INCH, IS: 1239,Thk.- Heavy, A33A
SUPPLY AND ERECTION OF VALVES Complete work of supply & erection of valves including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, supply and erection of matching companion flanges, gaskets, fasteners, nuts & studs, etc. but not limited to, the following items in accordance with relevant specifications indicated in scope of work, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation of all types of valve by bolting, threading or welding,including supply of gaskets, nuts & studs, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valves wherever requried.
Gate Valves as per details below:
Size - 8 INCH, Rating - 150
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Tripple Offset Butterfly Valves as per details below:
Size - 6 INCH, Rating - 150
Size - 4 INCH, Rating - 150
Ball Valves as per details below:
Size - 2 INCH, Rating - 150
Size - 1 INCH, Rating - 150
Size - 3/4 INCH, Rating - 150
Size - 1/2 INCH, Rating - 150
Non Return Valves as per details below
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Pressure Safety Valve (Max pressure=10 kg/cm2)
Size - 6 INCH, Rating - 150
Expansion Bellow as per details below:-
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
SUPPLY & ERECTION OF Y /T TYPE STRAINER Design, Engineering, Manufacturing, Testing, Inspection, supply & erection including Packaging, Forwarding, Transportation, supply and erection of matching companion flanges, gaskets, fasteners, nuts & Stud , etc. to store of "Y / T" type strainer with cast Steel body & SS strainer as per approved Drg.,/ Data Sheet/ PJS etc but not limited to, the following in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT as per details below. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of "Y / T" type strainer with cast Steel body & SS strainer by bolting, threading or welding,including supply of gaskets, nuts & bolts, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks,pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried as per details below.
4" T/Y Type Strainer - 150#
HYDRANT SYSTEM Complete work of supply & erection including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, gaskets, fasteners, nuts & bolts, etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
Supply & Erection of stand post type hydrant with single outlet 3" inlet bronze landing valve (conforming to IS : 5290 : 1993 ) with matching flanges (Conforming to IS : 6392 Table-17 / ANSI B 16.5), with control fitted with 63 mm dia instantaneous female coupling on the outlet complete with orifice flange as required for network pressure ranging from 9 to 10.5 Kg/cm2, blank cap and chain. bolts, nuts and gaskets, etc., complete as per data sheet & technical specification . (1 set consists of 1 no. of single valves with stand post & matching flange, gaskets, nut & bolt all complete). The assembly shall be suitable for direct erection over companion flange on branch outlet from main header. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts, etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of 1750 LPM stand post type water cum foam monitor (UL Listed / FM Approved) as per Data sheet & Technical Specification with jet / spray nozzle with drain provision and all other accessories including suitable orifice plate for network pressure ranging from 8 to 10.5 Kg/cm2 and matching flanges of 4" size confirming to IS: 6392 Table - 17, bolts, nuts and gaskets complete including painting as specified & directed by EIC. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of FRP fire hose cabinet suitable for accommodating 2 nos of 15 mtrs long canvas hose with coupling, branch pipe and nozzle for external hydrants with double glass door, lock & key including outdoor mounting arrangement complete as specified. Necessary hangers and brackets for hose, nozzle and branch pipe or universal branch pipe to be provided within the cabinet. Provision for putting key of the cabinet shall also be provided.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection of FRP fire hose cabinet including supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply of 63 mm dia 15 m long RRL Hose including gunmetal male and female instanteneous type coupling , machine wound with GI wire complete in all respects. Hose to IS:636 type A, UL Listed / FM Approved and coupling to IS:903:1984 with ISI certification. (One set consists of 2 nos each of 15m length)
Supply of Jet Nozzle with branch pipe ( IS 903)
4 way Fire Brigade Inlet
HIGH EXPANSION FOAM GENERATORS
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Fixed Type) with by-pass system along with inlet coupling & pressure gauge, Fixed Inline foam Inductor ,Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification .
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Portable Type) along with by-pass system inlet coupling, portable type Inline Foam Inductor, Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification.
SUPPLY & ERECTION OF ITEMS/COMPONENTS RELATED TO FIXED FOAM SYSTEM
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 200/210 ltr HDPE barrels.
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 1000 ltr HDPE Tote. The outer frame shall be Rigid welded hot dipped galvanized tubular steel cage. Bottom plate shall be galvanized steel base shaped for inner container support and stability.
ROTATING EQUIPMENT WORKS - MECHANICAL WORKS (SUPPLY & ERECTION)
DIESEL ENGINE DRIVEN FIRE MAIN PUMP
Design, Engineering, Manufacturing, Supply, Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at Neemrana elaborated in tender and elsewhere) of Diesel engine driven Vertical Turbine single outlet pumping set with bronze impeller with C.I. Body and pump accessories complete and connected by a flexible coupling to a water cooled diesel engine (Conforming to IS : 10002) mounted on a common structural base plate with anti- vibration pads and foundation complete with AMF panel, battery (including one spare battery) battery charging, cooling system, fuel tank, fuel system, automatic starting arrangement, exhaust pipe of required length to discharge at suitable height with muffler to meet latest environmental norms, day oil tank (storage of 8 hrs. running capacity) mounted on suitable structural supports, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, common base plate, flexible coupling, coupling guard, power and control cable, consumables, compulsory erection & commissioning spares, first fill of lubricants, fuels, Special Tools Tackles etc., Configuration, Interfacing, erection at site, Integrated Testing & Commissioning as per Job specifications and Special Instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr. Head : 80 mwc Engine BHP : Suitable size to be furnished by the bidder with sizing calculation.
ELECTRICAL MOTOR DRIVEN MAIN FIRE PUMP.
Design, Engineering, Manufacturing, Supply , Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at at various locations of IGL sites elaborated in tender and elsewhere) of Electirc motor driven Vertical Turbine single outlet pumping set including electric motor, Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr Head : 80 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
ELECTRIC MOTOR JOCKEY PUMP
Design, Engineering, Manufacturing, Supply and commissioning (including packaging and forwarding, insurance, handling and unloading at various locations of IGL sites elaborated in tender and elsewhere) of Vertical Turbine Jockey pump. including electric motor,VFD (Varaiable frequency drive ), Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The Jockey pump shall be started and stopped automatically through pressure transmitter. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Fire Jockey Pump Capacity of Pump : 10 m3/hr Head : 88 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
NOTES: 1. Price for Erection and Commissioning spares (As per Vendor’s recommendation) is to be included in the above mentioned SOR Items of Pumps. 2. Bidder shall also furnish details of special tools and tackles considered by them. Rates for all these items shall be included in the quoted rates for Pumps and shall not be paid separately. 3. The Vendor shall be completely responsible for the design, materials, manufacture & fabrication, testing, inspection, preparation for shipment,transport of the above equipment, erection, testing & commissioning strictly in accordance with the SOR and all attachment thereto. All items shall be provided with test certificates. 4. Inspection shall also be performed by Owner’s delegate, as set out and specified in the codes and particular documents forming part of this SOR
Supply, fabrication and erection of steel Structures for Crossovers & Structural works in & around Fire Water Pump House
Prepartion of fabrication drawings including bill of materials, getting approval from consultant including supply of raw materials, fabrication of steel structures such as columns, column bracings, roof girder/truss, roof bracings, struts, roof purlins, side girts, sag angles/rods, monorail beams, stair cases, ladders, crossover,valve operting platforms, handrailing, pipe supports, gratings, chequred plate, etc to complete the terminal work including surface preparation by sand blasting confirming to Swedish Standard SA 2½ for painting, supply and application of 1st coat of Inorganic Zinc Silicate 75 microns DFT , 2nd coat of Intermediate of Epoxy High Build Micaceous Iron Oxide(MIO) 100 microns DFT, 3rd coat Finishing paint of Acrylic Polyurethane 40 microns DFT and 4th coat Finishing Paint of Acrylic Polyurethane 40 microns DFT(Total DFT=255 microns minimum) of approved colour .Finishing coat shall be applied one before erection and one coat after erection, including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension.The work shall be completed in all respect as per drawings ,technical specification and direction of the Engineer-in-Charge.
Design, Engineering, Manufacturing, Testing, Inspection, Supply, erection testing & commissioning including Packaging, Forwarding, Transportation to store of Monorail with Guided Chain pulley block & Trolley of 5T capacity as per approved Drg.,/ Data Sheet/ PJS etc in accordance with relevant specifications indicated in PJS, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
INSTRUMENTATION WORKS (FOR FIRE PROTECTION SYSTEM) Complete Instrumentation work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), FRLS cables, Ex-proof JBs, Ex-proof glands,Pressure Guages,Pressure Transmiiters, Pressure Switches,Level Transmitters, SOVs. cable tray, U/G cable trench, canopies, earthing wire/ strip, logic / graphics development / modification as per site requirement in the PLC (common for plant & fire fighting system), etc. as per site requirement.
ELECTRICAL WORKS (FOR FIRE PROTECTION SYSTEM) Complete Electrical work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), cables, LT Panel, Ex-proof glands, cable tray, U/G cable trench, canopies, earthing wire/ strip etc. as per site requirement to complete the project in all respect.
FIRE ALARM & CLEAN AGENT SYSTEM
DESIGN, ENGINEERING, SUPPLY, HANDLING, TRANSPORTATION, INSTALLATION, TESTING & COMMISSIONING OF HIGH PRESSURE CLEAN AGENT (INERT GAS) FIRE SUPPRESSION SYSTEM Clean Gas Fire Suppression Centralised System (Inert Gas High Pressure) complete with required accessories with main and standby bank of cylinders & each cylinder filled with Clean agent Fire extinguishing Agent (Inert Gas) as Main Bank and Standby Bank (As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved) with Pressure Switch & Locking Device, Discharge Nozzles designed to provide the proper flow rate and distribution of Clean Agent to total flood the hazard area: 180 deg. / 360 deg. ( As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved ), ASTM A106 Gr. B Piping, fittings & supports, etc. , Manifold fabricated from seamless pipe, A106 Gr. B having inlets with supports etc. with activation through intelligent addressable Fire Detection and Alarm System panels after receiving signals from detectors, response indicators etc. all complete supply as per approved scheme & Tender and instructions of Engineer-in-charge. The bidder shall include mandatory spares as described in PJS along with recommended list of spares required for 2 years trouble free operation. Inert gas shall be used as Clean Gas Agent. Complete work of supply, installation, testing, commissioning includes Handling including lifting and transportation from Owner's / Contractor's own storage yard to work site and inspection charges, installation, testing, commissioning & handing over in accordance with relevant Specifications & relevant Data Sheets indicated in PJS, scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. The areas of rooms to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h) and Battery room of size 2.5 m X 2 m X 4 m (h
Note - 1. Design shall be done based on largest room size with provision to discharge gas in affected room through directional valves including Room void, Ceiling Void & Floor void/ Cable trenches. Balancing of gas discharge in rooms shall be done keeping in NOAEL level as per NFPA2001.
DESIGN, ENGINEERING, SUPPLY, ERECTION, TESTING & COMMISSIONING OF FIRE DETECTION & ALARM SYSTEM FOR CONTROL ROOM BUILDING Intelligent addressable Fire Detection and Alarm System with fire alarm cum gas release panels which will also have provision to receive signals from LHD system in cable trenches, detectors, response indicators, cabling , cable trays, manual gas release switch , manual gas abort switch, hooter with flasher, manual call points etc. all complete as per approved scheme & enclosed drawings. Work shall be carried out as per direction of EIC. Manual call points shall be installed at strategic operating locations. Provision of AC / Exhaust Tripping alongwith supply of cables, relays, glands etc. also be considred under this scope. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of FIRE DETECTION & ALARM SYSTEM including performance testing of the system, painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever required. The area of control room buildings to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h), Battery room of size 2.5 m X 2 m X 4 m (h) and officeR room of size 4 m X 3.2 m X 4 m (h)
Note: Fire Alarm Panel & Gas Release Panel shall have provision to work on 230 V AC / 24VDC (Input Power supply ) as per availabilty of Input power at Stations.
MANUAL CALL POINTS Complete work of Design, Engineering, Supply, Handling, Transportation, Installation, Testing & Commissioning of Exproof & IP 67 Manual Call Points. The MCP shall be break Glass Type in Red Colour and are located at the following locations in the LCNG Terminal Area: (i) Security room,(ii) Loading /unloading Pump area, (iii) Truck Unloading area (iv) Outside the Dyke area towards LCNG storage tank. These manual call points shall be hard wired to PLC.The scope of work also includes supply,inspection,laying,termination & testing of required quantities of cable as per MCP location along with necessary hardware or other accessories required to enhance the functionality,operation of the complete system.
SUPPLY OF SAFETY EQUIPMENTS & HAND APPLIANCES
DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER (STORED PRESSURE TYPE) Supply & Installation of Dry Chemical Powder type fire extinguisher as per IS: 15683-2006 & MECON TS no. MEC/TS/05/28/081/26 suitable for inverted operation with anticorrosive treatment and hydraulically tested to a pressure of 25 kg/ sq.cm . Extinguishers externally painted with red enamel and fixed to wall with brackets complete with internal charge and spanner complete. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
4 Kg Capacity
9 Kg Capacity
25 Kg Capacity (Trolley mounted)
CO2 TYPE FIRE EXTINGUISHERS Supply & Installation of CO2 type fire extinguishers with steel cylinder with dischange valve as per MECON TS no. MEC/TS/05/28/081/25 and conforming to IS:15683. Extinguisher shall be painted with red enamel paint. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 4.5 kg.
MECHANICAL FOAM TYPE FIRE EXTINGUISHER Supply & Installation of Portable fire extinguisher mechanical form (Gas cartridge) type of 9 litres capacity with initial charge manufactured as per IS 15683 with ISI mark.The refills shall be manufactured as per IS 4989 (Part-II)- 1984 with ISI marked. The cartridge shall be manufactured as per IS:4947- 1985 with ISI mark. The extinguisher will be painted with fire red colour and will be provided with all accessories, wall mounting brackets and screws. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 9 Ltr
FIRE BUCKETS Supply and installation of galvenised steel set of 4 fire buckets (9 Ltrs. Cap) as per technical specification no. MEC/TS/05/28/081/03 and confirming to IS: 2546-1974 RA2000.Buckets shall be painted with red enamel paint and fixed to suitable location . Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
EYE WASH SHOWER (STAINLESS STEEL) Complete work of supply & installation including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, of Eye Wash shower pedestal mounted along with supply & laying of required GI Heavy Pipes, fittings Isolation valves , etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Supply & laying of GI Pipe (Heavy Grade ) of Size (25 NB) minimum,Fittings,isolation valves for water connection to the Eye Wash Shower (Near Odorising Skid) from the avaialable nearest tapping point of Portable water are deemed to be included in the quoted price.
SUPPLY OF SAFETY EQUIPMENT Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Goggles for Eye Protection from LNG Spray
Protective Apron for cryogenic liquid handling
Safety Helmet with IGL Logo - IS-2925-1984 RA2000
Gumboots for protection during LNG Spillage
Stretcher with blanket- IS-4037-1967 RA-2001.
First Aid Box
Supply,Installation,Testing and Commissioining of Electrical Siren (1 Km Diametrical range) & Interfacing with Fire Alarm Panel/Gas Release Panel
Hand operated siren (1 Km Diametrical range) IS-6194-1971 RA- 2006
Portable Gas Detectors / Explosive meter
Wind Shock
Part IV- Architectural Works
PYLON (Monolith Tower) 1.5 m X 5 m, located midway between ingress and egress. Supplying & Installing Monolith as per approved design by RSGL/MECON. The item is lump sum and shall include all relevant costs associated with putting up such facility including supply, fabrication, erection, assembly, commissioning the MONOLITH (with client's name & logo) including electrical cabling and lighting etc. for the same. The specifications are as follows: • Made out of MS hollow pipe framework (hollow steel sections as per design requirement) with epoxy primer and paint. • Structure covered with PVDF coated 4 mm thick ACM (Alstrong/ Aludecor/ Alucobond) sheet cladding duly by cold forming, CNC machine routed and fold with retro reflective graphics and vinyl for backlit purpose. • ACM shall have a Total Thickness of 4mm : Top Coil 0.5mm ( 3003/3105 Grade as per IS - 737 1986 with minimum 25 microns PVdF Coating on top coil and Polyester / Epoxy coating on Back Coil ( 4 -7 microns PVDF ACM in colour and shape as per approved design. ACM to be cut in shapes as indicated. • COMPANY LOGO: 770mm in ht. & 50mm projected Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night with LED lights (Osram / Neenja / equ.) with necessary electrical fittings. • LNG LOGO: 440mm in ht. & 50 mm projected Acrylic / PETG thermoformed letters(as letters(as per art work) covered covered with vinyl of approved make with the provisions of illuminations during night. • Cut Retro reflective vinyl (Avery / 3M / equ.) on ACM top to be paste as per artwork and fixed as per the details on both sides with provision of the LED numbers for rate indication. • Retro Reflective Sheeting shall be Type XI DG3 Microprismetice as per ASTM D 4956-09 in required colour & Size on both sides and cutouts for product names, logos, etc. duly CNC Plotted. • Special spot lights (2 nos.- 400 watts with metal halide lights of Philips make) to be incorporated in design to light up the entire tower with throw from base. • The backlit portion of the monolith to be lit with sufficient numbers T5 (28 W) tube lights (Philips make) with electronic choke, mounted on MS tube frames with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • Steel structural frame to be installed on RCC foundations. Top and exposed sides of the foundation to be cladded in 18 mm thick black polished granite. • All work to be done in line, level and plumb, all complete with by works, as approved.
CANOPY FASCIA: 800 mm wide (in corporate colours on canopy vertical faces.Supplying & Installing Canopy Fascia with following specifications: • 900 mm height canopy fascia with PVDF coated 4 mm thick ACM sheet cladding duly CNC machine machine routed and fold as per drawing mounted on 150 mm depth box made out of 25 mm x 25 mm MS hollow pipe frame with powder coating and top GI sheet cover. • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice duly pasted on ACM in required size & shape (colour scheme and design to be approved) on mild steel framework with part backlit for company logo and name. • LED Lighting modules or encased LED light strips (Osram / Neenja / equ.) and power supply. • The letters sh all be in 30 mm thick Acrylic/ PC duly CNC Routed in require shape & Size as per direction of concerned engineer. • Structural frame to be welded rigidly/ Bolted to the structural member of existing canopy structures. • FASCIA BAND: 300mm in ht. Acrylic / PETG thermoformed band with necessary support covered with vinyl of approved make with the provisions of illuminations during night with LED of approved make. • COMPANY LOGO: 900mm in ht. Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on all 4 sides. • Company Name: 450mm in ht. 040 white Acrylic / PETG thermoformed letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on front right as per DWG. • Canopy fascia to be made in 12 m. (min.) long straight panels factory plan/processed at converters factory and assembled/installed at site. Corner piece (1 metre both sides) on both sides (as required), also to be factory plan/processed/assembled and installed at site. Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb. • Backlit section of the fascia shall be of 4 meters length and one/ two logos (depending on design) and shall have sufficient number of LED/T5 (28 W) tube light with electronic chokes mounted with plastic holders to structural frame. • The top of the fascia shall have 4 mm thick ACM with hinged GI service door in backlit part. The back of the fascia to have 18 gauge GI sheets. • Multi-strand copper conductors with PVC insulation to be used. • The bottom and top of the fascia shall have a white ACM trim to cover the gap between the canopy and fascia. • The contractor should make suitable fixing arrangement, which should be duly vetted by a certified structural engineer as per the actual dimensions of the canopy structure.
CANOPY COLUMN CLADDINGSupplying & Installing Column Cladding: • Using PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond), mounted on box made out of 20 mm x 20 mm MS square pipe hollow section with powder coating. • Backlit design band in the centre in PET G (Eastman / Bayer / equ.) with yellow vinyl, LED lighting modules (Osram / Neenja / equ.) and power supply according to the design. • The structural framework shall be fixed securely to existing canopy column by welding at site. • ACM panel fixing to ensure consistent joint gaps and panel size. • All grooves shall be sealed with sealant material of approved colour, all complete with by works, as approved.
SAFETY SIGN200 mm X 200 mm Supplying & Installing safety sign stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on column cladding.
DISPENSER STICKERSupplying & Installing stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on dispensers.
SPREADER450 mm X 450 mm Supplying & Installing Pump Spreader: • Made of 25 mm x 25 mm MS hollow pipe frame box with powder coating & cladding on both sides of PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond) • CNC Router cut graphics in 040 white acrylic with LED modules (Osram / Neenja / equ.) for lighting • Spreader frame to be fixed securely to canopy columns with box & cap arrangement. • Sufficient no. of LED/ CFL lights and electronic chokes fixed with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • AII work to be done in line, level and plumb, all complete with by works, as approved.
CRASH GUARDSupplying & Installing 80mm dia MS pipe or as per design with two coat of zinc oxide primer and metallic paint as per the design.
BUILDING FASCIA700 mm wide on top of building faces in elevation.Supplying & Installing Building Fascia with following specifications: • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape (colour scheme to be approved) on mild steel framework. • Structural frame to be fasteners/ Nut Bolted to the building walls with dash fasteners and leveling 'arrangement. • Building fascia to be made in maximum length of straight panels (with minimum no. of joints) straight panels factory plan/processed at converters factory and assembled/installed at site. • Corner piece (1 metre both sides) on both sides, also to be factory plan/processed/assembled and installed at site. • Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb, all complete with by works, as approved.
MANDATORY SIGN300X 450mm (on toilets) & 300X 600mm (in compressor and LCV area) - rectangular or trapezoidal in shape.Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved.
DIRECTION SIGN400 mm X 1000 mm heightSupplying & Installing Entry-Exit sign: • Made out of 25 mm x 25 mm MS hollow pipe frame box with powder coating and covered with 4 mm thick ACM sheet (Alstrong/ Aludecor/ Alucobond) and CNC router cut graphics in 040 white acrylicwith LED modules (Osram / Neenja / equ.) for lighting and base foundation. • The sign frame to be fixed securely to CC foundation. • The CC foundation shall have 8mm thick polished black granite tiles cladding on top and all exposed side surfaces. • All work to be done in line, level and plumb, all complete with by works, as approved.
HOARDING3000 mm wideSupplying and installing Printed Flex sheet (make LG / 3M / Avery) with approved Art work (suitable for front lit) to be Fitted to the steel sheet of existing Hoarding structure in aluminium frame using Klick Rail System & as per direction of concerned Engineer/ client.
SPOT HALOGEN LIGHTSAt an interval of 2 m C/C on top of existing steel hoarding. Supplying and installing Spot halogen lights (150 watts of Philips make) at an interval of 2 m center to center on top of existing hoarding including supply with steel bracket and laying of cable upto electrical panel of Electrical room (in Utility building) complete in all respect.
Part V- Electrical Works
A. Electrical Supply
415 V LT PDB and APFC Panel
Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A..
LIGHTING DISTRIBUTION BOARDS
Design, engineering, manufacture, shop testing,supply, 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Supply including packing and forwarding, transportation, delivery at storage of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Design, engineering, manufacture, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :
Supply of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring , test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Design, engineering, shop testing, Supply , packing and forwarding, transportation, delivery at storage and from storage to site lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Design, engineering, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Supply of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Supply of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Supply of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Supply and Fabrication of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Supply of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Supply of Main Distribution Frame - 12 pair
Supply of LAN switch with single incomer and min 10-port out going port complete in all respect.
Supply of required material for Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Supply including packing and forwarding, transportation, delivery at storage to site of 11 kv/433 V outdoor type, 3Ph, 50Hz,copper wound, Dyn11, ONAN distribution transformer with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Supply of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating, pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
Supply, of 11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Supply of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
Supply of Tools and Instrument as per Annexure - A of scope of work.
Flame Proof Tool Box Set as per Annexure - A of scope of work.
B. Erection, Testing & Commissioning
415 V LT PDB and APFC Panel
Erection, testing & Commissioning of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A.
LIGHTING DISTRIBUTION BOARDS
Erection, testing & Commissioning of 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification, data sheet and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc including all labour and materials as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Erection, testing & Commissioning of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Erection, testing & Commissioning of following :
Laying of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Erection, testing & Commissioning of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Erection, testing & Commissioning of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Erection, testing & Commissioning of latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Erection, testing & Commissioning of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Erection, testing & Commissioning of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, installation of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Erection, testing & Commissioning of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Installation of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, installation of necessary anchor bolts and grouting etc, applying one coat of anti rust primer, two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Installation of the following including the necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Laying of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Erection, testing & Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Erection, testing & Commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Installation of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Erection, testing & Commissioning of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Erection, testing & Commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Laying of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Laying of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Erection, testing & Commissioning of Main Distribution Frame - 12 pair
Erection, testing & Commissioning of LAN switch with single incomer and min 10-port out going port complete in all respect.
Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Erection, testing & Commissioning of 11 kv/433 V outdoor type, 3Ph, 50Hz, copper wound, Dyn11, ONAN distribution transformer r with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Erection, testing & Commissioning of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB std.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Erection, testing & Commissioning of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for LNG station. However the official fees towards the approvals shall be reimbursed by the client.
Kindly quote in Percentage in M column on total Estimate Amount of Percentage part (Civil Work SOR Part -B (item CIV-01 to CIV -48) refer sheet2. Note: Bidders shall quote percentage in plus ( '+ ') or minus (' - ') in column M by which total estimated price in the Sheet2 shall be increased or decreased to arrive at bidder‘s quoted price (excluding GST) for Sheet2. Bidder's quoted item rates shall be arrived by applying offered percentage on estimated rates of all BoQ items given in Sheet2.
Description of Work / Item(s)
Amount
Part II- STEEL STRUCTURAL WORKS
Canopy in Structural Steel Supply, fabrication, erection and handing over of structural steel fabricated canopy [steel structures tentative weight @ 85 Kg/Sqm] with 0.6mm thick Zincalume/galvalume colour coated steel sheets for roof sheeting as per specification, including 0.6mm thk. cold rolled colour coated steel profile sheet of Trac (150F) Pre-Coated Steel false ceiling system, with powder coated finishes as per manufacturers instruction and specification, facia, flashings, Rain Water Pipe, electrical cable pipe & Gutter, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site (Total DFT 120 microns). The work is to be completed in all respect as per technical specification of Canopy, scope of work, detailed construction drawings and directions of the Engineer-in-charge. (rectangular plan area shall be considered for measurement) 1. The tentative weight of structural steel shall be 85 kg/m2 (only weight of Steel structures elements excluding sheeting and false ceiling) of canopy area. A variation of +/- 15% of structural steel weight shall be deemed included in the item. Any increase/decrease beyond this limit shall attract payment/deduction @ Rs. 80000/- per Tonne. 2. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes, roof sheeting, flashing, fitting and fixtures, false ceiling system, gutter, rain water pipes, electrical cable pipe and bends, electrodes, edge colour coated sheets (for signage works), primer, paint and all consumables etc. with all bye works and sundry works complete in all respect. 3. Rate to exclude cost of electrical wiring for under lights and Signage works, supply & fixing of all electrical fixtures/materials, signage works & Civil Foundation.
Supply, fabrication & erection of Steel structure Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, Cat Ladder, handrails, hoardings for signages, LCV stand, MS channel drain covers, column, rafter, purlins, runners, bracings, beam for monorail, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation, painting as per specification, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (The cost & weight of MS bolts and nuts (permanent and service), washers, electrodes, putty, gases, shims, packs, cost of straightening of raw materials, Built up section at any shape, cutting of flats from plates and providing splices, paints, tools, plants, testing of materials, etc and all other consumables as required for the work shall be deemed to be included in the quoted rates.)
Supply and erection of Zincalume high tensile colour coated sheet on roof and sides: Supply and erection of 0.5mm TCT zincalume high tensile colour coated steel sheets (fy=550MPa) conforming to IS:15961 having trapezoidal profile with a cover width of 930-1020 mm and 28-32 mm deep crest at pitch of 186-250mmc/c with minimum two ribs at centre for stiffening. with zincalume coating 150gsm. The sheet shall have a total coating thickness of 35 micron,super durable polyester colorbond XRW quality paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both side surface as per IS:15965. The paint system should have stable resin & inorganic pigments for paint durability and lead free for water harvesting The sheet shall have anti-capillary groove to avoid any seepage of water through lateral over lap, compatible flashing, Trims, ridge panel and fixtures, accessories, sealing tape etc., including transportation and delivery at site, storage and handling at site, cutting and bending of sheets to required shapes and sizes and erecting them on roof and sides using self-drilling, self-tapping fasteners which shall be hot dip galvanized with Xylon coated with EPDM Seals conforming to AS: 3566 class 3 at proper position. Roof sheet shall be laid in colours as per approved colours scheme. All works shall be completed in all respect as per specification, scope and description of works and as per direction of the Engineer-In-Charge. Mode of measurement shall be total covering area of sheeting. Lapping of sheets, ridges and flashes shall not be paid extra. (Only net laid area to be measured for payment)
Supply, fabrication & erection of MS Gate Supply, fabrication and fixing in position steel entrance gate (as per the design shown in the tender drawing) supply of raw materials, transportation and delivery at site, unloading, storage and handling at site, site assembly and finally erection at appropriate locations. gates shall be fabricated out of channel and Sq Bar with all fixtures like MS Pivot, M.S sheet boxing ,locking arrangement, MS tower bolts, gate stopper, hold fast, MS wheel with ball bearing , MS tee bend to shape and embedded in the road surface for gate opening track , etc. including painting as per specification. The work is to be completed in all respect as per drawings and techanical specification and direction of the Engineer-in-Charge. a) 5.5m clear opening width of gate in two panels
Providing and Fixing Fencing Structure Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over a two coat of primer in approved shade including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge. a) Fencing height 2.1m
Providing and Fixing Fencing Gates Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge. a) 2m Wide x 2.1m High
Providing and fixing chequered plate covers Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Providing and fixing safety guard Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe (size 600 deep and 500 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge.
Part III- Fire Protection System
PLANT PIPING (ABOVEGROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, Flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Above Ground pipes: Receiving and taking over / handling of all supplied materials from Contractor's / Owner's designated place(s), transportation including loading, unloading, handling from Contractor's /Owner's designated place(s) to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except supply of those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading etc.; fabrication of fittings like miter bends, tees, reducers etc other than those in the scope of contractor and erection of the same, erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes; cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; surface preparation, primer, painting complete of pipeline with fittings as per MECON painting specification no. MEC/S/05/21/07, Painting to be done by spray only, clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Supply of paints, solvents and primers , preparation of surfaces by sand/grit blasting using one of the abrasives and application of Zinc Ethyl Silicate Primer (P1- One coat @ 75 microns DFT / coat), Two pack epoxy – polyamid mio Intermediate / undercoat paint (U1- One coat @ 100 microns DFT/coat minimum) and Two pack aliphatic acrylic polyurethane finish paint ( F2-Two Coats @ 40 microns DFT /coat minimum) suitable for normal corrosive painting environment as defined in contract document. Identification, lettering/ numbering, colour coding and colour bands as per Industry Quality Control manual etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings,Standards and instruction of Engineer-in-Charge. Painting shall be done by spray only.
10 INCH, IS: 3589,Thk.-7.1 mm
8 INCH, IS: 3589,Thk.-6.3 mm
6 INCH, IS: 1239,Thk.- Heavy
4 INCH, IS: 1239,Thk.- Heavy
3 INCH, IS: 1239,Thk.- Heavy
2 INCH, IS: 1239,Thk.- Heavy
1 INCH, IS: 1239,Thk.- Heavy
3/4 INCH, IS: 1239,Thk.- Heavy
PLANT PIPING (UNDER GROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, WRAPPING & COATING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications indicated in scope of work indicated in SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Under Ground pipes: Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all under ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading /tapping etc.,; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes;
Cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Job also includes trenching to all types of soil to specified depth, laying the already wrapped and coated pipes, back filling the trenches with available approved soil and also laying the pipes through hume pipes/culverts. Cost of wrapping as per IS: 10221 to be included in the cost including supply of wrapping materials. Cost of supply of hume pipes for road crossing also to be included.
8 INCH, IS: 3589,Thk.-6.3 mm,A33A,
6 INCH, IS: 1239,Thk.- Heavy, A33A
4 INCH, IS: 1239,Thk.- Heavy, A33A
SUPPLY AND ERECTION OF VALVES Complete work of supply & erection of valves including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, supply and erection of matching companion flanges, gaskets, fasteners, nuts & studs, etc. but not limited to, the following items in accordance with relevant specifications indicated in scope of work, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation of all types of valve by bolting, threading or welding,including supply of gaskets, nuts & studs, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valves wherever requried.
Gate Valves as per details below:
Size - 8 INCH, Rating - 150
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Tripple Offset Butterfly Valves as per details below:
Size - 6 INCH, Rating - 150
Size - 4 INCH, Rating - 150
Ball Valves as per details below:
Size - 2 INCH, Rating - 150
Size - 1 INCH, Rating - 150
Size - 3/4 INCH, Rating - 150
Size - 1/2 INCH, Rating - 150
Non Return Valves as per details below
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Pressure Safety Valve (Max pressure=10 kg/cm2)
Size - 6 INCH, Rating - 150
Expansion Bellow as per details below:-
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
SUPPLY & ERECTION OF Y /T TYPE STRAINER Design, Engineering, Manufacturing, Testing, Inspection, supply & erection including Packaging, Forwarding, Transportation, supply and erection of matching companion flanges, gaskets, fasteners, nuts & Stud , etc. to store of "Y / T" type strainer with cast Steel body & SS strainer as per approved Drg.,/ Data Sheet/ PJS etc but not limited to, the following in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT as per details below. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of "Y / T" type strainer with cast Steel body & SS strainer by bolting, threading or welding,including supply of gaskets, nuts & bolts, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks,pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried as per details below.
4" T/Y Type Strainer - 150#
HYDRANT SYSTEM Complete work of supply & erection including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, gaskets, fasteners, nuts & bolts, etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
Supply & Erection of stand post type hydrant with single outlet 3" inlet bronze landing valve (conforming to IS : 5290 : 1993 ) with matching flanges (Conforming to IS : 6392 Table-17 / ANSI B 16.5), with control fitted with 63 mm dia instantaneous female coupling on the outlet complete with orifice flange as required for network pressure ranging from 9 to 10.5 Kg/cm2, blank cap and chain. bolts, nuts and gaskets, etc., complete as per data sheet & technical specification . (1 set consists of 1 no. of single valves with stand post & matching flange, gaskets, nut & bolt all complete). The assembly shall be suitable for direct erection over companion flange on branch outlet from main header. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts, etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of 1750 LPM stand post type water cum foam monitor (UL Listed / FM Approved) as per Data sheet & Technical Specification with jet / spray nozzle with drain provision and all other accessories including suitable orifice plate for network pressure ranging from 8 to 10.5 Kg/cm2 and matching flanges of 4" size confirming to IS: 6392 Table - 17, bolts, nuts and gaskets complete including painting as specified & directed by EIC. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of FRP fire hose cabinet suitable for accommodating 2 nos of 15 mtrs long canvas hose with coupling, branch pipe and nozzle for external hydrants with double glass door, lock & key including outdoor mounting arrangement complete as specified. Necessary hangers and brackets for hose, nozzle and branch pipe or universal branch pipe to be provided within the cabinet. Provision for putting key of the cabinet shall also be provided.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection of FRP fire hose cabinet including supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply of 63 mm dia 15 m long RRL Hose including gunmetal male and female instanteneous type coupling , machine wound with GI wire complete in all respects. Hose to IS:636 type A, UL Listed / FM Approved and coupling to IS:903:1984 with ISI certification. (One set consists of 2 nos each of 15m length)
Supply of Jet Nozzle with branch pipe ( IS 903)
4 way Fire Brigade Inlet
HIGH EXPANSION FOAM GENERATORS
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Fixed Type) with by-pass system along with inlet coupling & pressure gauge, Fixed Inline foam Inductor ,Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification .
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Portable Type) along with by-pass system inlet coupling, portable type Inline Foam Inductor, Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification.
SUPPLY & ERECTION OF ITEMS/COMPONENTS RELATED TO FIXED FOAM SYSTEM
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 200/210 ltr HDPE barrels.
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 1000 ltr HDPE Tote. The outer frame shall be Rigid welded hot dipped galvanized tubular steel cage. Bottom plate shall be galvanized steel base shaped for inner container support and stability.
ROTATING EQUIPMENT WORKS - MECHANICAL WORKS (SUPPLY & ERECTION)
DIESEL ENGINE DRIVEN FIRE MAIN PUMP
Design, Engineering, Manufacturing, Supply, Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at Neemrana elaborated in tender and elsewhere) of Diesel engine driven Vertical Turbine single outlet pumping set with bronze impeller with C.I. Body and pump accessories complete and connected by a flexible coupling to a water cooled diesel engine (Conforming to IS : 10002) mounted on a common structural base plate with anti- vibration pads and foundation complete with AMF panel, battery (including one spare battery) battery charging, cooling system, fuel tank, fuel system, automatic starting arrangement, exhaust pipe of required length to discharge at suitable height with muffler to meet latest environmental norms, day oil tank (storage of 8 hrs. running capacity) mounted on suitable structural supports, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, common base plate, flexible coupling, coupling guard, power and control cable, consumables, compulsory erection & commissioning spares, first fill of lubricants, fuels, Special Tools Tackles etc., Configuration, Interfacing, erection at site, Integrated Testing & Commissioning as per Job specifications and Special Instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr. Head : 80 mwc Engine BHP : Suitable size to be furnished by the bidder with sizing calculation.
ELECTRICAL MOTOR DRIVEN MAIN FIRE PUMP.
Design, Engineering, Manufacturing, Supply , Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at at various locations of IGL sites elaborated in tender and elsewhere) of Electirc motor driven Vertical Turbine single outlet pumping set including electric motor, Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr Head : 80 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
ELECTRIC MOTOR JOCKEY PUMP
Design, Engineering, Manufacturing, Supply and commissioning (including packaging and forwarding, insurance, handling and unloading at various locations of IGL sites elaborated in tender and elsewhere) of Vertical Turbine Jockey pump. including electric motor,VFD (Varaiable frequency drive ), Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The Jockey pump shall be started and stopped automatically through pressure transmitter. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Fire Jockey Pump Capacity of Pump : 10 m3/hr Head : 88 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
NOTES: 1. Price for Erection and Commissioning spares (As per Vendor’s recommendation) is to be included in the above mentioned SOR Items of Pumps. 2. Bidder shall also furnish details of special tools and tackles considered by them. Rates for all these items shall be included in the quoted rates for Pumps and shall not be paid separately. 3. The Vendor shall be completely responsible for the design, materials, manufacture & fabrication, testing, inspection, preparation for shipment,transport of the above equipment, erection, testing & commissioning strictly in accordance with the SOR and all attachment thereto. All items shall be provided with test certificates. 4. Inspection shall also be performed by Owner’s delegate, as set out and specified in the codes and particular documents forming part of this SOR
Supply, fabrication and erection of steel Structures for Crossovers & Structural works in & around Fire Water Pump House
Prepartion of fabrication drawings including bill of materials, getting approval from consultant including supply of raw materials, fabrication of steel structures such as columns, column bracings, roof girder/truss, roof bracings, struts, roof purlins, side girts, sag angles/rods, monorail beams, stair cases, ladders, crossover,valve operting platforms, handrailing, pipe supports, gratings, chequred plate, etc to complete the terminal work including surface preparation by sand blasting confirming to Swedish Standard SA 2½ for painting, supply and application of 1st coat of Inorganic Zinc Silicate 75 microns DFT , 2nd coat of Intermediate of Epoxy High Build Micaceous Iron Oxide(MIO) 100 microns DFT, 3rd coat Finishing paint of Acrylic Polyurethane 40 microns DFT and 4th coat Finishing Paint of Acrylic Polyurethane 40 microns DFT(Total DFT=255 microns minimum) of approved colour .Finishing coat shall be applied one before erection and one coat after erection, including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension.The work shall be completed in all respect as per drawings ,technical specification and direction of the Engineer-in-Charge.
Design, Engineering, Manufacturing, Testing, Inspection, Supply, erection testing & commissioning including Packaging, Forwarding, Transportation to store of Monorail with Guided Chain pulley block & Trolley of 5T capacity as per approved Drg.,/ Data Sheet/ PJS etc in accordance with relevant specifications indicated in PJS, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
INSTRUMENTATION WORKS (FOR FIRE PROTECTION SYSTEM) Complete Instrumentation work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), FRLS cables, Ex-proof JBs, Ex-proof glands,Pressure Guages,Pressure Transmiiters, Pressure Switches,Level Transmitters, SOVs. cable tray, U/G cable trench, canopies, earthing wire/ strip, logic / graphics development / modification as per site requirement in the PLC (common for plant & fire fighting system), etc. as per site requirement.
ELECTRICAL WORKS (FOR FIRE PROTECTION SYSTEM) Complete Electrical work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), cables, LT Panel, Ex-proof glands, cable tray, U/G cable trench, canopies, earthing wire/ strip etc. as per site requirement to complete the project in all respect.
FIRE ALARM & CLEAN AGENT SYSTEM
DESIGN, ENGINEERING, SUPPLY, HANDLING, TRANSPORTATION, INSTALLATION, TESTING & COMMISSIONING OF HIGH PRESSURE CLEAN AGENT (INERT GAS) FIRE SUPPRESSION SYSTEM Clean Gas Fire Suppression Centralised System (Inert Gas High Pressure) complete with required accessories with main and standby bank of cylinders & each cylinder filled with Clean agent Fire extinguishing Agent (Inert Gas) as Main Bank and Standby Bank (As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved) with Pressure Switch & Locking Device, Discharge Nozzles designed to provide the proper flow rate and distribution of Clean Agent to total flood the hazard area: 180 deg. / 360 deg. ( As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved ), ASTM A106 Gr. B Piping, fittings & supports, etc. , Manifold fabricated from seamless pipe, A106 Gr. B having inlets with supports etc. with activation through intelligent addressable Fire Detection and Alarm System panels after receiving signals from detectors, response indicators etc. all complete supply as per approved scheme & Tender and instructions of Engineer-in-charge. The bidder shall include mandatory spares as described in PJS along with recommended list of spares required for 2 years trouble free operation. Inert gas shall be used as Clean Gas Agent. Complete work of supply, installation, testing, commissioning includes Handling including lifting and transportation from Owner's / Contractor's own storage yard to work site and inspection charges, installation, testing, commissioning & handing over in accordance with relevant Specifications & relevant Data Sheets indicated in PJS, scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. The areas of rooms to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h) and Battery room of size 2.5 m X 2 m X 4 m (h
Note - 1. Design shall be done based on largest room size with provision to discharge gas in affected room through directional valves including Room void, Ceiling Void & Floor void/ Cable trenches. Balancing of gas discharge in rooms shall be done keeping in NOAEL level as per NFPA2001.
DESIGN, ENGINEERING, SUPPLY, ERECTION, TESTING & COMMISSIONING OF FIRE DETECTION & ALARM SYSTEM FOR CONTROL ROOM BUILDING Intelligent addressable Fire Detection and Alarm System with fire alarm cum gas release panels which will also have provision to receive signals from LHD system in cable trenches, detectors, response indicators, cabling , cable trays, manual gas release switch , manual gas abort switch, hooter with flasher, manual call points etc. all complete as per approved scheme & enclosed drawings. Work shall be carried out as per direction of EIC. Manual call points shall be installed at strategic operating locations. Provision of AC / Exhaust Tripping alongwith supply of cables, relays, glands etc. also be considred under this scope. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of FIRE DETECTION & ALARM SYSTEM including performance testing of the system, painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever required. The area of control room buildings to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h), Battery room of size 2.5 m X 2 m X 4 m (h) and officeR room of size 4 m X 3.2 m X 4 m (h)
Note: Fire Alarm Panel & Gas Release Panel shall have provision to work on 230 V AC / 24VDC (Input Power supply ) as per availabilty of Input power at Stations.
MANUAL CALL POINTS Complete work of Design, Engineering, Supply, Handling, Transportation, Installation, Testing & Commissioning of Exproof & IP 67 Manual Call Points. The MCP shall be break Glass Type in Red Colour and are located at the following locations in the LCNG Terminal Area: (i) Security room,(ii) Loading /unloading Pump area, (iii) Truck Unloading area (iv) Outside the Dyke area towards LCNG storage tank. These manual call points shall be hard wired to PLC.The scope of work also includes supply,inspection,laying,termination & testing of required quantities of cable as per MCP location along with necessary hardware or other accessories required to enhance the functionality,operation of the complete system.
SUPPLY OF SAFETY EQUIPMENTS & HAND APPLIANCES
DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER (STORED PRESSURE TYPE) Supply & Installation of Dry Chemical Powder type fire extinguisher as per IS: 15683-2006 & MECON TS no. MEC/TS/05/28/081/26 suitable for inverted operation with anticorrosive treatment and hydraulically tested to a pressure of 25 kg/ sq.cm . Extinguishers externally painted with red enamel and fixed to wall with brackets complete with internal charge and spanner complete. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
4 Kg Capacity
9 Kg Capacity
25 Kg Capacity (Trolley mounted)
CO2 TYPE FIRE EXTINGUISHERS Supply & Installation of CO2 type fire extinguishers with steel cylinder with dischange valve as per MECON TS no. MEC/TS/05/28/081/25 and conforming to IS:15683. Extinguisher shall be painted with red enamel paint. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 4.5 kg.
MECHANICAL FOAM TYPE FIRE EXTINGUISHER Supply & Installation of Portable fire extinguisher mechanical form (Gas cartridge) type of 9 litres capacity with initial charge manufactured as per IS 15683 with ISI mark.The refills shall be manufactured as per IS 4989 (Part-II)- 1984 with ISI marked. The cartridge shall be manufactured as per IS:4947- 1985 with ISI mark. The extinguisher will be painted with fire red colour and will be provided with all accessories, wall mounting brackets and screws. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 9 Ltr
FIRE BUCKETS Supply and installation of galvenised steel set of 4 fire buckets (9 Ltrs. Cap) as per technical specification no. MEC/TS/05/28/081/03 and confirming to IS: 2546-1974 RA2000.Buckets shall be painted with red enamel paint and fixed to suitable location . Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
EYE WASH SHOWER (STAINLESS STEEL) Complete work of supply & installation including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, of Eye Wash shower pedestal mounted along with supply & laying of required GI Heavy Pipes, fittings Isolation valves , etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Supply & laying of GI Pipe (Heavy Grade ) of Size (25 NB) minimum,Fittings,isolation valves for water connection to the Eye Wash Shower (Near Odorising Skid) from the avaialable nearest tapping point of Portable water are deemed to be included in the quoted price.
SUPPLY OF SAFETY EQUIPMENT Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Goggles for Eye Protection from LNG Spray
Protective Apron for cryogenic liquid handling
Safety Helmet with IGL Logo - IS-2925-1984 RA2000
Gumboots for protection during LNG Spillage
Stretcher with blanket- IS-4037-1967 RA-2001.
First Aid Box
Supply,Installation,Testing and Commissioining of Electrical Siren (1 Km Diametrical range) & Interfacing with Fire Alarm Panel/Gas Release Panel
Hand operated siren (1 Km Diametrical range) IS-6194-1971 RA- 2006
Portable Gas Detectors / Explosive meter
Wind Shock
Part IV- Architectural Works
PYLON (Monolith Tower) 1.5 m X 5 m, located midway between ingress and egress. Supplying & Installing Monolith as per approved design by RSGL/MECON. The item is lump sum and shall include all relevant costs associated with putting up such facility including supply, fabrication, erection, assembly, commissioning the MONOLITH (with client's name & logo) including electrical cabling and lighting etc. for the same. The specifications are as follows: • Made out of MS hollow pipe framework (hollow steel sections as per design requirement) with epoxy primer and paint. • Structure covered with PVDF coated 4 mm thick ACM (Alstrong/ Aludecor/ Alucobond) sheet cladding duly by cold forming, CNC machine routed and fold with retro reflective graphics and vinyl for backlit purpose. • ACM shall have a Total Thickness of 4mm : Top Coil 0.5mm ( 3003/3105 Grade as per IS - 737 1986 with minimum 25 microns PVdF Coating on top coil and Polyester / Epoxy coating on Back Coil ( 4 -7 microns PVDF ACM in colour and shape as per approved design. ACM to be cut in shapes as indicated. • COMPANY LOGO: 770mm in ht. & 50mm projected Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night with LED lights (Osram / Neenja / equ.) with necessary electrical fittings. • LNG LOGO: 440mm in ht. & 50 mm projected Acrylic / PETG thermoformed letters(as letters(as per art work) covered covered with vinyl of approved make with the provisions of illuminations during night. • Cut Retro reflective vinyl (Avery / 3M / equ.) on ACM top to be paste as per artwork and fixed as per the details on both sides with provision of the LED numbers for rate indication. • Retro Reflective Sheeting shall be Type XI DG3 Microprismetice as per ASTM D 4956-09 in required colour & Size on both sides and cutouts for product names, logos, etc. duly CNC Plotted. • Special spot lights (2 nos.- 400 watts with metal halide lights of Philips make) to be incorporated in design to light up the entire tower with throw from base. • The backlit portion of the monolith to be lit with sufficient numbers T5 (28 W) tube lights (Philips make) with electronic choke, mounted on MS tube frames with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • Steel structural frame to be installed on RCC foundations. Top and exposed sides of the foundation to be cladded in 18 mm thick black polished granite. • All work to be done in line, level and plumb, all complete with by works, as approved.
CANOPY FASCIA: 800 mm wide (in corporate colours on canopy vertical faces.Supplying & Installing Canopy Fascia with following specifications: • 900 mm height canopy fascia with PVDF coated 4 mm thick ACM sheet cladding duly CNC machine machine routed and fold as per drawing mounted on 150 mm depth box made out of 25 mm x 25 mm MS hollow pipe frame with powder coating and top GI sheet cover. • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice duly pasted on ACM in required size & shape (colour scheme and design to be approved) on mild steel framework with part backlit for company logo and name. • LED Lighting modules or encased LED light strips (Osram / Neenja / equ.) and power supply. • The letters sh all be in 30 mm thick Acrylic/ PC duly CNC Routed in require shape & Size as per direction of concerned engineer. • Structural frame to be welded rigidly/ Bolted to the structural member of existing canopy structures. • FASCIA BAND: 300mm in ht. Acrylic / PETG thermoformed band with necessary support covered with vinyl of approved make with the provisions of illuminations during night with LED of approved make. • COMPANY LOGO: 900mm in ht. Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on all 4 sides. • Company Name: 450mm in ht. 040 white Acrylic / PETG thermoformed letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on front right as per DWG. • Canopy fascia to be made in 12 m. (min.) long straight panels factory plan/processed at converters factory and assembled/installed at site. Corner piece (1 metre both sides) on both sides (as required), also to be factory plan/processed/assembled and installed at site. Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb. • Backlit section of the fascia shall be of 4 meters length and one/ two logos (depending on design) and shall have sufficient number of LED/T5 (28 W) tube light with electronic chokes mounted with plastic holders to structural frame. • The top of the fascia shall have 4 mm thick ACM with hinged GI service door in backlit part. The back of the fascia to have 18 gauge GI sheets. • Multi-strand copper conductors with PVC insulation to be used. • The bottom and top of the fascia shall have a white ACM trim to cover the gap between the canopy and fascia. • The contractor should make suitable fixing arrangement, which should be duly vetted by a certified structural engineer as per the actual dimensions of the canopy structure.
CANOPY COLUMN CLADDINGSupplying & Installing Column Cladding: • Using PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond), mounted on box made out of 20 mm x 20 mm MS square pipe hollow section with powder coating. • Backlit design band in the centre in PET G (Eastman / Bayer / equ.) with yellow vinyl, LED lighting modules (Osram / Neenja / equ.) and power supply according to the design. • The structural framework shall be fixed securely to existing canopy column by welding at site. • ACM panel fixing to ensure consistent joint gaps and panel size. • All grooves shall be sealed with sealant material of approved colour, all complete with by works, as approved.
SAFETY SIGN200 mm X 200 mm Supplying & Installing safety sign stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on column cladding.
DISPENSER STICKERSupplying & Installing stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on dispensers.
SPREADER450 mm X 450 mm Supplying & Installing Pump Spreader: • Made of 25 mm x 25 mm MS hollow pipe frame box with powder coating & cladding on both sides of PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond) • CNC Router cut graphics in 040 white acrylic with LED modules (Osram / Neenja / equ.) for lighting • Spreader frame to be fixed securely to canopy columns with box & cap arrangement. • Sufficient no. of LED/ CFL lights and electronic chokes fixed with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • AII work to be done in line, level and plumb, all complete with by works, as approved.
CRASH GUARDSupplying & Installing 80mm dia MS pipe or as per design with two coat of zinc oxide primer and metallic paint as per the design.
BUILDING FASCIA700 mm wide on top of building faces in elevation.Supplying & Installing Building Fascia with following specifications: • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape (colour scheme to be approved) on mild steel framework. • Structural frame to be fasteners/ Nut Bolted to the building walls with dash fasteners and leveling 'arrangement. • Building fascia to be made in maximum length of straight panels (with minimum no. of joints) straight panels factory plan/processed at converters factory and assembled/installed at site. • Corner piece (1 metre both sides) on both sides, also to be factory plan/processed/assembled and installed at site. • Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb, all complete with by works, as approved.
MANDATORY SIGN300X 450mm (on toilets) & 300X 600mm (in compressor and LCV area) - rectangular or trapezoidal in shape.Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved.
DIRECTION SIGN400 mm X 1000 mm heightSupplying & Installing Entry-Exit sign: • Made out of 25 mm x 25 mm MS hollow pipe frame box with powder coating and covered with 4 mm thick ACM sheet (Alstrong/ Aludecor/ Alucobond) and CNC router cut graphics in 040 white acrylicwith LED modules (Osram / Neenja / equ.) for lighting and base foundation. • The sign frame to be fixed securely to CC foundation. • The CC foundation shall have 8mm thick polished black granite tiles cladding on top and all exposed side surfaces. • All work to be done in line, level and plumb, all complete with by works, as approved.
HOARDING3000 mm wideSupplying and installing Printed Flex sheet (make LG / 3M / Avery) with approved Art work (suitable for front lit) to be Fitted to the steel sheet of existing Hoarding structure in aluminium frame using Klick Rail System & as per direction of concerned Engineer/ client.
SPOT HALOGEN LIGHTSAt an interval of 2 m C/C on top of existing steel hoarding. Supplying and installing Spot halogen lights (150 watts of Philips make) at an interval of 2 m center to center on top of existing hoarding including supply with steel bracket and laying of cable upto electrical panel of Electrical room (in Utility building) complete in all respect.
Part V- Electrical Works
A. Electrical Supply
415 V LT PDB and APFC Panel
Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A..
LIGHTING DISTRIBUTION BOARDS
Design, engineering, manufacture, shop testing,supply, 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Supply including packing and forwarding, transportation, delivery at storage of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Design, engineering, manufacture, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :
Supply of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring , test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Design, engineering, shop testing, Supply , packing and forwarding, transportation, delivery at storage and from storage to site lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Design, engineering, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Supply of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Supply of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Supply of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Supply and Fabrication of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Supply of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Supply of Main Distribution Frame - 12 pair
Supply of LAN switch with single incomer and min 10-port out going port complete in all respect.
Supply of required material for Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Supply including packing and forwarding, transportation, delivery at storage to site of 11 kv/433 V outdoor type, 3Ph, 50Hz,copper wound, Dyn11, ONAN distribution transformer with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Supply of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating, pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
Supply, of 11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Supply of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
Supply of Tools and Instrument as per Annexure - A of scope of work.
Flame Proof Tool Box Set as per Annexure - A of scope of work.
B. Erection, Testing & Commissioning
415 V LT PDB and APFC Panel
Erection, testing & Commissioning of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A.
LIGHTING DISTRIBUTION BOARDS
Erection, testing & Commissioning of 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification, data sheet and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc including all labour and materials as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Erection, testing & Commissioning of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Erection, testing & Commissioning of following :
Laying of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Erection, testing & Commissioning of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Erection, testing & Commissioning of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Erection, testing & Commissioning of latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Erection, testing & Commissioning of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Erection, testing & Commissioning of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, installation of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Erection, testing & Commissioning of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Installation of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, installation of necessary anchor bolts and grouting etc, applying one coat of anti rust primer, two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Installation of the following including the necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Laying of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Erection, testing & Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Erection, testing & Commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Installation of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Erection, testing & Commissioning of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Erection, testing & Commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Laying of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Laying of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Erection, testing & Commissioning of Main Distribution Frame - 12 pair
Erection, testing & Commissioning of LAN switch with single incomer and min 10-port out going port complete in all respect.
Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Erection, testing & Commissioning of 11 kv/433 V outdoor type, 3Ph, 50Hz, copper wound, Dyn11, ONAN distribution transformer r with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Erection, testing & Commissioning of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB std.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Erection, testing & Commissioning of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for LNG station. However the official fees towards the approvals shall be reimbursed by the client.
Kindly quote in Percentage in M column on total Estimate Amount of Percentage part (Civil Work SOR Part -C (item CIV-01 to CIV -48) refer sheet3. Note: Bidders shall quote percentage in plus ( '+ ') or minus (' - ') in column M by which total estimated price in the Sheet3 shall be increased or decreased to arrive at bidder‘s quoted price (excluding GST) for Sheet3. Bidder's quoted item rates shall be arrived by applying offered percentage on estimated rates of all BoQ items given in Sheet3.
Description of Work / Item(s)
Amount
Part II- STEEL STRUCTURAL WORKS
C.STEEL STRUCTURAL WORKS
Canopy in Structural Steel Supply, fabrication, erection and handing over of structural steel fabricated canopy [steel structures tentative weight @ 85 Kg/Sqm] with 0.6mm thick Zincalume/galvalume colour coated steel sheets for roof sheeting as per specification, including 0.6mm thk. cold rolled colour coated steel profile sheet of Trac (150F) Pre-Coated Steel false ceiling system, with powder coated finishes as per manufacturers instruction and specification, facia, flashings, Rain Water Pipe, electrical cable pipe & Gutter, including surface preparation by mechanical cleaning including application of one coat of Zinc phosphate primer of DFT 35 microns at shop, second coat of Zinc phosphate primer of DFT 35 microns at site after erection and two coats of finishing paint of synthetic enamel of DFT 25 microns each per coat at site (Total DFT 120 microns). The work is to be completed in all respect as per technical specification of Canopy, scope of work, detailed construction drawings and directions of the Engineer-in-charge. (rectangular plan area shall be considered for measurement) 1. The tentative weight of structural steel shall be 85 kg/m2 (only weight of Steel structures elements excluding sheeting and false ceiling) of canopy area. A variation of +/- 15% of structural steel weight shall be deemed included in the item. Any increase/decrease beyond this limit shall attract payment/deduction @ Rs. 80000/- per Tonne. 2. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as structural steel, purlins, nuts, bolts, washers, screws, seals, wire ropes, roof sheeting, flashing, fitting and fixtures, false ceiling system, gutter, rain water pipes, electrical cable pipe and bends, electrodes, edge colour coated sheets (for signage works), primer, paint and all consumables etc. with all bye works and sundry works complete in all respect. 3. Rate to exclude cost of electrical wiring for under lights and Signage works, supply & fixing of all electrical fixtures/materials, signage works & Civil Foundation.
Supply, fabrication & erection of Steel structure Supplying, Fabricating & Erecting in position steel structures fabricated from MS rolled section conforming to IS:2062 and/or from pipes conforming to IS:1161 for cascade supporting structures, loading/unloading platform, Cat Ladder, handrails, hoardings for signages, LCV stand, MS channel drain covers, column, rafter, purlins, runners, bracings, beam for monorail, etc. or any other structures required as per constructon drawings for completion of works, including surface preparation, painting as per specification, including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension. The work shall be completed in all respect as per drawings, technical specification and direction of the Engineer-in-Charge. (The cost & weight of MS bolts and nuts (permanent and service), washers, electrodes, putty, gases, shims, packs, cost of straightening of raw materials, Built up section at any shape, cutting of flats from plates and providing splices, paints, tools, plants, testing of materials, etc and all other consumables as required for the work shall be deemed to be included in the quoted rates.)
Supply and erection of Zincalume high tensile colour coated sheet on roof and sides: Supply and erection of 0.5mm TCT zincalume high tensile colour coated steel sheets (fy=550MPa) conforming to IS:15961 having trapezoidal profile with a cover width of 930-1020 mm and 28-32 mm deep crest at pitch of 186-250mmc/c with minimum two ribs at centre for stiffening. with zincalume coating 150gsm. The sheet shall have a total coating thickness of 35 micron,super durable polyester colorbond XRW quality paint system of 20 microns on exposed surface and 5 micron reverse polyester coat on back surface over 5 micron primer coat on both side surface as per IS:15965. The paint system should have stable resin & inorganic pigments for paint durability and lead free for water harvesting The sheet shall have anti-capillary groove to avoid any seepage of water through lateral over lap, compatible flashing, Trims, ridge panel and fixtures, accessories, sealing tape etc., including transportation and delivery at site, storage and handling at site, cutting and bending of sheets to required shapes and sizes and erecting them on roof and sides using self-drilling, self-tapping fasteners which shall be hot dip galvanized with Xylon coated with EPDM Seals conforming to AS: 3566 class 3 at proper position. Roof sheet shall be laid in colours as per approved colours scheme. All works shall be completed in all respect as per specification, scope and description of works and as per direction of the Engineer-In-Charge. Mode of measurement shall be total covering area of sheeting. Lapping of sheets, ridges and flashes shall not be paid extra. (Only net laid area to be measured for payment)
Supply, fabrication & erection of MS Gate Supply, fabrication and fixing in position steel entrance gate (as per the design shown in the tender drawing) supply of raw materials, transportation and delivery at site, unloading, storage and handling at site, site assembly and finally erection at appropriate locations. gates shall be fabricated out of channel and Sq Bar with all fixtures like MS Pivot, M.S sheet boxing ,locking arrangement, MS tower bolts, gate stopper, hold fast, MS wheel with ball bearing , MS tee bend to shape and embedded in the road surface for gate opening track , etc. including painting as per specification. The work is to be completed in all respect as per drawings and techanical specification and direction of the Engineer-in-Charge. a) 5.5m clear opening width of gate in two panels
Providing and Fixing Fencing Structure Supplying, fabricating & fixing of steel structural fencing fabricated from pipes conforming to IS:1161 and plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over a two coat of primer in approved shade including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in of block 500x500x500 for fixing of posts etc complete as per drawing, technical specifications,scope of works and directions of the Engineer-In-Charge. a) Fencing height 2.1m
Providing and Fixing Fencing Gates Supply, fabrication & fixing of fencing gates fabricated from pipes conforming to IS:1161, plates conforming to IS:2062 & fixing of GI weldmesh made from 3mm GI wire @ 75 mm bothways to structural steel frame by means of welding/bolting, locking arrangement, etc., including surface prepartion by mechanical claening including application of two coats of approved quality of synthetic enamel paint over two coats of primer in approved shade including loading, transportation and unloading delivery at erection site of all fabricated structures, storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension including making pokets & pouring with PCC (1:2:4) in block of size 500x500x500mm for fixing of posts etc. complete as per drawings, technical specifications, scope of works and directions of the Engineer-In-Charge. a) 2m Wide x 2.1m High
Providing and fixing chequered plate covers Providing and fixing chequered plate in panel over cable trench, man hole cover & over steel structure platform including cutting, welding of stiffners, hoisting, fixing in position, and applying two or more coats of approved quality synthetic enamel over a priming coat of approved colour etc. complete as per scope, detailed drawings, technical specifications and directions of the Engineer-In-Charge.
Providing and fixing safety guard Providing and fixing safety guard with 80 mm heavy duty G.I. Pipe (size 600 deep and 500 width inside) grouted with ready mix high strength grout mortar of approved manufacturer and painted with approved quality paint as per scope of work, detailed construction drawings, technical specifications and directions of Engineer-In-Charge.
Part III- Fire Protection System
MECHANICAL WORKS
PLANT PIPING (ABOVEGROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, Flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Above Ground pipes: Receiving and taking over / handling of all supplied materials from Contractor's / Owner's designated place(s), transportation including loading, unloading, handling from Contractor's /Owner's designated place(s) to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except supply of those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all above ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading etc.; fabrication of fittings like miter bends, tees, reducers etc other than those in the scope of contractor and erection of the same, erection of pipes of all types and thickness over sleepers, overhead on racks and at all elevations; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes; cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; surface preparation, primer, painting complete of pipeline with fittings as per MECON painting specification no. MEC/S/05/21/07, Painting to be done by spray only, clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Supply of paints, solvents and primers , preparation of surfaces by sand/grit blasting using one of the abrasives and application of Zinc Ethyl Silicate Primer (P1- One coat @ 75 microns DFT / coat), Two pack epoxy – polyamid mio Intermediate / undercoat paint (U1- One coat @ 100 microns DFT/coat minimum) and Two pack aliphatic acrylic polyurethane finish paint ( F2-Two Coats @ 40 microns DFT /coat minimum) suitable for normal corrosive painting environment as defined in contract document. Identification, lettering/ numbering, colour coding and colour bands as per Industry Quality Control manual etc. as specified including rub down and touch up of shop primer or scrapping of shop primer wherever required and providing of scaffolding for all heights, labour, materials, tools and tackles, consumables, supervision etc. to complete the work in all respect as per Specification, Drawings,Standards and instruction of Engineer-in-Charge. Painting shall be done by spray only.
10 INCH, IS: 3589,Thk.-7.1 mm
8 INCH, IS: 3589,Thk.-6.3 mm
6 INCH, IS: 1239,Thk.- Heavy
4 INCH, IS: 1239,Thk.- Heavy
3 INCH, IS: 1239,Thk.- Heavy
2 INCH, IS: 1239,Thk.- Heavy
1 INCH, IS: 1239,Thk.- Heavy
3/4 INCH, IS: 1239,Thk.- Heavy
PLANT PIPING (UNDER GROUND) SUPPLY, FABRICATION, ERECTION, INSTALLATION, WRAPPING & COATING AND TESTING OF PIPING :
SUPPLY OF PIPES: Complete work of supply of ERW pipes with fittings, flanges etc., including all taxes, duties, transportation and inspection charges but not limited to, the following items in accordance with relevant specifications indicated in scope of work indicated in SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
FABRICATION, ERECTION, INSTALLATION, PAINTING AND TESTING OF Under Ground pipes: Receiving and taking over of all Owner supplied materials from Owner's designated place(s) of issue, transportation including loading, unloading, handling from Owner's designated place(s) of issue to Contractor's own stock yard(s)/ work site(s)/ work shop(s) including arranging all necessary storage area(s) thereof, as required; supply of all balance materials (except those specified subsequently in SOR), equipment, consumables as defined in Contractor's scope of supply and their transportation to the work site(s); performing all under ground piping fabrication works including cutting,edge preparation (inclusive of grinding the edges of pipes, fittings etc. to match with the matching edges of uneven/ different thickness wherever required) including, fit up, bending, pre-heating wherever required, welding, threading /tapping etc.,; hook-up with, existing header, equipments etc, fittings of all sizes i.e.elbows, reducers, tees, 'blind flanges, including fixing of all types of gaskets , bolts, studs and nuts of all sizes;
Cleaning and flushing, carrying out hydrostatic test at 15 kg/cm2 (g) (minimum 1.50 times the design pressure) ,carrying out 10% non-destructive testing of each size such as radiography by gamma ray, magnetic particle, liquid penetration etc., pre-commissioning and commissioning; clean-up and restoration of site, preparation of as built drawings, documents and project records; transportation of surplus free issue materials to Owner's designated place(s); completing all works in all respects as per the AFC drawings, specifications, standards and other provisions of Contract and instruction of Engineer-in-Charge. Job also includes trenching to all types of soil to specified depth, laying the already wrapped and coated pipes, back filling the trenches with available approved soil and also laying the pipes through hume pipes/culverts. Cost of wrapping as per IS: 10221 to be included in the cost including supply of wrapping materials. Cost of supply of hume pipes for road crossing also to be included.
8 INCH, IS: 3589,Thk.-6.3 mm,A33A,
6 INCH, IS: 1239,Thk.- Heavy, A33A
4 INCH, IS: 1239,Thk.- Heavy, A33A
SUPPLY AND ERECTION OF VALVES Complete work of supply & erection of valves including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, supply and erection of matching companion flanges, gaskets, fasteners, nuts & studs, etc. but not limited to, the following items in accordance with relevant specifications indicated in scope of work, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation of all types of valve by bolting, threading or welding,including supply of gaskets, nuts & studs, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valves wherever requried.
Gate Valves as per details below:
Size - 8 INCH, Rating - 150
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Tripple Offset Butterfly Valves as per details below:
Size - 6 INCH, Rating - 150
Size - 4 INCH, Rating - 150
Ball Valves as per details below:
Size - 2 INCH, Rating - 150
Size - 1 INCH, Rating - 150
Size - 3/4 INCH, Rating - 150
Size - 1/2 INCH, Rating - 150
Non Return Valves as per details below
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
Pressure Safety Valve (Max pressure=10 kg/cm2)
Size - 6 INCH, Rating - 150
Expansion Bellow as per details below:-
Size - 6 INCH, Rating - 150
Size - 2 INCH, Rating - 150
SUPPLY & ERECTION OF Y /T TYPE STRAINER Design, Engineering, Manufacturing, Testing, Inspection, supply & erection including Packaging, Forwarding, Transportation, supply and erection of matching companion flanges, gaskets, fasteners, nuts & Stud , etc. to store of "Y / T" type strainer with cast Steel body & SS strainer as per approved Drg.,/ Data Sheet/ PJS etc but not limited to, the following in accordance with relevant specifications , drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT as per details below. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of "Y / T" type strainer with cast Steel body & SS strainer by bolting, threading or welding,including supply of gaskets, nuts & bolts, etc. and insertion/ erection of the same on either side of flanged valve at all elevations of pipe sleepers, supports or overhead on racks,pumps & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried as per details below.
4" T/Y Type Strainer - 150#
HYDRANT SYSTEM Complete work of supply & erection including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, gaskets, fasteners, nuts & bolts, etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
Supply & Erection of stand post type hydrant with single outlet 3" inlet bronze landing valve (conforming to IS : 5290 : 1993 ) with matching flanges (Conforming to IS : 6392 Table-17 / ANSI B 16.5), with control fitted with 63 mm dia instantaneous female coupling on the outlet complete with orifice flange as required for network pressure ranging from 9 to 10.5 Kg/cm2, blank cap and chain. bolts, nuts and gaskets, etc., complete as per data sheet & technical specification . (1 set consists of 1 no. of single valves with stand post & matching flange, gaskets, nut & bolt all complete). The assembly shall be suitable for direct erection over companion flange on branch outlet from main header. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts, etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of 1750 LPM stand post type water cum foam monitor (UL Listed / FM Approved) as per Data sheet & Technical Specification with jet / spray nozzle with drain provision and all other accessories including suitable orifice plate for network pressure ranging from 8 to 10.5 Kg/cm2 and matching flanges of 4" size confirming to IS: 6392 Table - 17, bolts, nuts and gaskets complete including painting as specified & directed by EIC. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection by bolting, threading or welding,including insertion/ erection of matching companion flanges, gaskets, fasteners, nuts & bolts etc supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply & Erection of FRP fire hose cabinet suitable for accommodating 2 nos of 15 mtrs long canvas hose with coupling, branch pipe and nozzle for external hydrants with double glass door, lock & key including outdoor mounting arrangement complete as specified. Necessary hangers and brackets for hose, nozzle and branch pipe or universal branch pipe to be provided within the cabinet. Provision for putting key of the cabinet shall also be provided.Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and Erection of FRP fire hose cabinet including supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever requried.
Supply of 63 mm dia 15 m long RRL Hose including gunmetal male and female instanteneous type coupling , machine wound with GI wire complete in all respects. Hose to IS:636 type A, UL Listed / FM Approved and coupling to IS:903:1984 with ISI certification. (One set consists of 2 nos each of 15m length)
Supply of Jet Nozzle with branch pipe ( IS 903)
4 way Fire Brigade Inlet
HIGH EXPANSION FOAM GENERATORS
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Fixed Type) with by-pass system along with inlet coupling & pressure gauge, Fixed Inline foam Inductor ,Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification .
Complete work comprising of Design, Engineering, Supply, Inspection, Erection, testing & commissioning of Water Turbine Powered based High Expansion Foam Generators (Portable Type) along with by-pass system inlet coupling, portable type Inline Foam Inductor, Foam pick up tube, strainer & ball valve complete as per the technical specificatrion . The Generator shall meet the stipulations of OISD / technical specification.
SUPPLY & ERECTION OF ITEMS/COMPONENTS RELATED TO FIXED FOAM SYSTEM
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 200/210 ltr HDPE barrels.
Foam Solution per tender spec. confirming to IS-4989 Part-II & UL listed, 3% concentrate filled in 1000 ltr HDPE Tote. The outer frame shall be Rigid welded hot dipped galvanized tubular steel cage. Bottom plate shall be galvanized steel base shaped for inner container support and stability.
ROTATING EQUIPMENT WORKS - MECHANICAL WORKS (SUPPLY & ERECTION)
DIESEL ENGINE DRIVEN FIRE MAIN PUMP
Design, Engineering, Manufacturing, Supply, Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at Neemrana elaborated in tender and elsewhere) of Diesel engine driven Vertical Turbine single outlet pumping set with bronze impeller with C.I. Body and pump accessories complete and connected by a flexible coupling to a water cooled diesel engine (Conforming to IS : 10002) mounted on a common structural base plate with anti- vibration pads and foundation complete with AMF panel, battery (including one spare battery) battery charging, cooling system, fuel tank, fuel system, automatic starting arrangement, exhaust pipe of required length to discharge at suitable height with muffler to meet latest environmental norms, day oil tank (storage of 8 hrs. running capacity) mounted on suitable structural supports, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, common base plate, flexible coupling, coupling guard, power and control cable, consumables, compulsory erection & commissioning spares, first fill of lubricants, fuels, Special Tools Tackles etc., Configuration, Interfacing, erection at site, Integrated Testing & Commissioning as per Job specifications and Special Instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr. Head : 80 mwc Engine BHP : Suitable size to be furnished by the bidder with sizing calculation.
ELECTRICAL MOTOR DRIVEN MAIN FIRE PUMP.
Design, Engineering, Manufacturing, Supply , Installation and commissioning (including packaging and forwarding, insurance, handling and unloading at at various locations of IGL sites elaborated in tender and elsewhere) of Electirc motor driven Vertical Turbine single outlet pumping set including electric motor, Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The main pump shall be started automatically through a pressure transmitter and stopped manually. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Capacity of Pump : 75 m3/hr Head : 80 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
ELECTRIC MOTOR JOCKEY PUMP
Design, Engineering, Manufacturing, Supply and commissioning (including packaging and forwarding, insurance, handling and unloading at various locations of IGL sites elaborated in tender and elsewhere) of Vertical Turbine Jockey pump. including electric motor,VFD (Varaiable frequency drive ), Cable, common base frame, matching flanges (conforming to IS:6392 table - 17), SS bolts, nuts, gaskets, coupling, coupling guard, foundation bolts, nuts and gaskets, electrics, instrumentation, cable laying, starting panels with soft starter, consumables, compulsory erection & commissioning spares, first fill of lubricants, special tools tackles, configuration, interfacing, integrated testing & commissioning as per job specifications and special instructions enclosed. The Jockey pump shall be started and stopped automatically through pressure transmitter. Provision of signal output to control room shall be there in the pump panel to be installed in pump house. The work shall be carried out as per direction of Engineer in Charge. Fire Jockey Pump Capacity of Pump : 10 m3/hr Head : 88 mwc Motor KW : Suitable size to be furnished by bidder with sizing calculation
NOTES: 1. Price for Erection and Commissioning spares (As per Vendor’s recommendation) is to be included in the above mentioned SOR Items of Pumps. 2. Bidder shall also furnish details of special tools and tackles considered by them. Rates for all these items shall be included in the quoted rates for Pumps and shall not be paid separately. 3. The Vendor shall be completely responsible for the design, materials, manufacture & fabrication, testing, inspection, preparation for shipment,transport of the above equipment, erection, testing & commissioning strictly in accordance with the SOR and all attachment thereto. All items shall be provided with test certificates. 4. Inspection shall also be performed by Owner’s delegate, as set out and specified in the codes and particular documents forming part of this SOR
Supply, fabrication and erection of steel Structures for Crossovers & Structural works in & around Fire Water Pump House
Prepartion of fabrication drawings including bill of materials, getting approval from consultant including supply of raw materials, fabrication of steel structures such as columns, column bracings, roof girder/truss, roof bracings, struts, roof purlins, side girts, sag angles/rods, monorail beams, stair cases, ladders, crossover,valve operting platforms, handrailing, pipe supports, gratings, chequred plate, etc to complete the terminal work including surface preparation by sand blasting confirming to Swedish Standard SA 2½ for painting, supply and application of 1st coat of Inorganic Zinc Silicate 75 microns DFT , 2nd coat of Intermediate of Epoxy High Build Micaceous Iron Oxide(MIO) 100 microns DFT, 3rd coat Finishing paint of Acrylic Polyurethane 40 microns DFT and 4th coat Finishing Paint of Acrylic Polyurethane 40 microns DFT(Total DFT=255 microns minimum) of approved colour .Finishing coat shall be applied one before erection and one coat after erection, including loading, transportation and unloading delivery at erection site, of all fabricated structures ,storage and handling at site, site assembly and finally erection of structures at appropriate location, alignment and welding of all structures true to line, level, plumb and dimension.The work shall be completed in all respect as per drawings ,technical specification and direction of the Engineer-in-Charge.
Design, Engineering, Manufacturing, Testing, Inspection, Supply, erection testing & commissioning including Packaging, Forwarding, Transportation to store of Monorail with Guided Chain pulley block & Trolley of 5T capacity as per approved Drg.,/ Data Sheet/ PJS etc in accordance with relevant specifications indicated in PJS, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT.
INSTRUMENTATION WORKS (FOR FIRE PROTECTION SYSTEM) Complete Instrumentation work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), FRLS cables, Ex-proof JBs, Ex-proof glands,Pressure Guages,Pressure Transmiiters, Pressure Switches,Level Transmitters, SOVs. cable tray, U/G cable trench, canopies, earthing wire/ strip, logic / graphics development / modification as per site requirement in the PLC (common for plant & fire fighting system), etc. as per site requirement.
ELECTRICAL WORKS (FOR FIRE PROTECTION SYSTEM) Complete Electrical work comprising of Design, Engineering, supply, erection, testing, commissioning, Inspection, Packaging, Forwarding, Transportation etc for the complete fire protection system which includes instruments (not limited to P&ID, piping GAD & other relevant documents), cables, LT Panel, Ex-proof glands, cable tray, U/G cable trench, canopies, earthing wire/ strip etc. as per site requirement to complete the project in all respect.
FIRE ALARM & CLEAN AGENT SYSTEM
DESIGN, ENGINEERING, SUPPLY, HANDLING, TRANSPORTATION, INSTALLATION, TESTING & COMMISSIONING OF HIGH PRESSURE CLEAN AGENT (INERT GAS) FIRE SUPPRESSION SYSTEM Clean Gas Fire Suppression Centralised System (Inert Gas High Pressure) complete with required accessories with main and standby bank of cylinders & each cylinder filled with Clean agent Fire extinguishing Agent (Inert Gas) as Main Bank and Standby Bank (As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved) with Pressure Switch & Locking Device, Discharge Nozzles designed to provide the proper flow rate and distribution of Clean Agent to total flood the hazard area: 180 deg. / 360 deg. ( As per NFPA 2001 & UL Listed / FM / VDS / LPCB approved ), ASTM A106 Gr. B Piping, fittings & supports, etc. , Manifold fabricated from seamless pipe, A106 Gr. B having inlets with supports etc. with activation through intelligent addressable Fire Detection and Alarm System panels after receiving signals from detectors, response indicators etc. all complete supply as per approved scheme & Tender and instructions of Engineer-in-charge. The bidder shall include mandatory spares as described in PJS along with recommended list of spares required for 2 years trouble free operation. Inert gas shall be used as Clean Gas Agent. Complete work of supply, installation, testing, commissioning includes Handling including lifting and transportation from Owner's / Contractor's own storage yard to work site and inspection charges, installation, testing, commissioning & handing over in accordance with relevant Specifications & relevant Data Sheets indicated in PJS, scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. The areas of rooms to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h) and Battery room of size 2.5 m X 2 m X 4 m (h
Note - 1. Design shall be done based on largest room size with provision to discharge gas in affected room through directional valves including Room void, Ceiling Void & Floor void/ Cable trenches. Balancing of gas discharge in rooms shall be done keeping in NOAEL level as per NFPA2001.
DESIGN, ENGINEERING, SUPPLY, ERECTION, TESTING & COMMISSIONING OF FIRE DETECTION & ALARM SYSTEM FOR CONTROL ROOM BUILDING Intelligent addressable Fire Detection and Alarm System with fire alarm cum gas release panels which will also have provision to receive signals from LHD system in cable trenches, detectors, response indicators, cabling , cable trays, manual gas release switch , manual gas abort switch, hooter with flasher, manual call points etc. all complete as per approved scheme & enclosed drawings. Work shall be carried out as per direction of EIC. Manual call points shall be installed at strategic operating locations. Provision of AC / Exhaust Tripping alongwith supply of cables, relays, glands etc. also be considred under this scope. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work, SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting and transportation from Owner's/ Contractor's own storage yard to work site and installation & commissioning of FIRE DETECTION & ALARM SYSTEM including performance testing of the system, painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning wherever required. The area of control room buildings to be protected are listed below:
Control Room building as comprising control room of size 4 m X 3.2 m X 4 m (h), Electrical Room of Size 4.5 m X 3.2 m X 4m (h), Battery room of size 2.5 m X 2 m X 4 m (h) and officeR room of size 4 m X 3.2 m X 4 m (h)
Note: Fire Alarm Panel & Gas Release Panel shall have provision to work on 230 V AC / 24VDC (Input Power supply ) as per availabilty of Input power at Stations.
MANUAL CALL POINTS Complete work of Design, Engineering, Supply, Handling, Transportation, Installation, Testing & Commissioning of Exproof & IP 67 Manual Call Points. The MCP shall be break Glass Type in Red Colour and are located at the following locations in the LCNG Terminal Area: (i) Security room,(ii) Loading /unloading Pump area, (iii) Truck Unloading area (iv) Outside the Dyke area towards LCNG storage tank. These manual call points shall be hard wired to PLC.The scope of work also includes supply,inspection,laying,termination & testing of required quantities of cable as per MCP location along with necessary hardware or other accessories required to enhance the functionality,operation of the complete system.
SUPPLY OF SAFETY EQUIPMENTS & HAND APPLIANCES
DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER (STORED PRESSURE TYPE) Supply & Installation of Dry Chemical Powder type fire extinguisher as per IS: 15683-2006 & MECON TS no. MEC/TS/05/28/081/26 suitable for inverted operation with anticorrosive treatment and hydraulically tested to a pressure of 25 kg/ sq.cm . Extinguishers externally painted with red enamel and fixed to wall with brackets complete with internal charge and spanner complete. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
4 Kg Capacity
9 Kg Capacity
25 Kg Capacity (Trolley mounted)
CO2 TYPE FIRE EXTINGUISHERS Supply & Installation of CO2 type fire extinguishers with steel cylinder with dischange valve as per MECON TS no. MEC/TS/05/28/081/25 and conforming to IS:15683. Extinguisher shall be painted with red enamel paint. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 4.5 kg.
MECHANICAL FOAM TYPE FIRE EXTINGUISHER Supply & Installation of Portable fire extinguisher mechanical form (Gas cartridge) type of 9 litres capacity with initial charge manufactured as per IS 15683 with ISI mark.The refills shall be manufactured as per IS 4989 (Part-II)- 1984 with ISI marked. The cartridge shall be manufactured as per IS:4947- 1985 with ISI mark. The extinguisher will be painted with fire red colour and will be provided with all accessories, wall mounting brackets and screws. Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Capacity 9 Ltr
FIRE BUCKETS Supply and installation of galvenised steel set of 4 fire buckets (9 Ltrs. Cap) as per technical specification no. MEC/TS/05/28/081/03 and confirming to IS: 2546-1974 RA2000.Buckets shall be painted with red enamel paint and fixed to suitable location . Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
EYE WASH SHOWER (STAINLESS STEEL) Complete work of supply & installation including Design, Engineering, Manufacturing, Testing, Inspection, Packaging, Forwarding, Transportation to store, of Eye Wash shower pedestal mounted along with supply & laying of required GI Heavy Pipes, fittings Isolation valves , etc but not limited to, the following items in accordance with relevant specifications indicated in scope of work, SCC, drawings, specification and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Supply & laying of GI Pipe (Heavy Grade ) of Size (25 NB) minimum,Fittings,isolation valves for water connection to the Eye Wash Shower (Near Odorising Skid) from the avaialable nearest tapping point of Portable water are deemed to be included in the quoted price.
SUPPLY OF SAFETY EQUIPMENT Complete work of supply includes transportation to store and inspection charges but not limited to, the following items in accordance with relevant Specifications & relevant Data Sheets indicated in scope of work,SCC, drawings, specification and instructions of EIC and as per all provisions of the CONTRACT DOCUMENT
Goggles for Eye Protection from LNG Spray
Protective Apron for cryogenic liquid handling
Safety Helmet with IGL Logo - IS-2925-1984 RA2000
Gumboots for protection during LNG Spillage
Stretcher with blanket- IS-4037-1967 RA-2001.
First Aid Box
Supply,Installation,Testing and Commissioining of Electrical Siren (1 Km Diametrical range) & Interfacing with Fire Alarm Panel/Gas Release Panel
Hand operated siren (1 Km Diametrical range) IS-6194-1971 RA- 2006
Portable Gas Detectors / Explosive meter
Wind Shock
Part IV- Architectural Works
PYLON (Monolith Tower) 1.5 m X 5 m, located midway between ingress and egress. Supplying & Installing Monolith as per approved design by RSGL/MECON. The item is lump sum and shall include all relevant costs associated with putting up such facility including supply, fabrication, erection, assembly, commissioning the MONOLITH (with client's name & logo) including electrical cabling and lighting etc. for the same. The specifications are as follows: • Made out of MS hollow pipe framework (hollow steel sections as per design requirement) with epoxy primer and paint. • Structure covered with PVDF coated 4 mm thick ACM (Alstrong/ Aludecor/ Alucobond) sheet cladding duly by cold forming, CNC machine routed and fold with retro reflective graphics and vinyl for backlit purpose. • ACM shall have a Total Thickness of 4mm : Top Coil 0.5mm ( 3003/3105 Grade as per IS - 737 1986 with minimum 25 microns PVdF Coating on top coil and Polyester / Epoxy coating on Back Coil ( 4 -7 microns PVDF ACM in colour and shape as per approved design. ACM to be cut in shapes as indicated. • COMPANY LOGO: 770mm in ht. & 50mm projected Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night with LED lights (Osram / Neenja / equ.) with necessary electrical fittings. • LNG LOGO: 440mm in ht. & 50 mm projected Acrylic / PETG thermoformed letters(as letters(as per art work) covered covered with vinyl of approved make with the provisions of illuminations during night. • Cut Retro reflective vinyl (Avery / 3M / equ.) on ACM top to be paste as per artwork and fixed as per the details on both sides with provision of the LED numbers for rate indication. • Retro Reflective Sheeting shall be Type XI DG3 Microprismetice as per ASTM D 4956-09 in required colour & Size on both sides and cutouts for product names, logos, etc. duly CNC Plotted. • Special spot lights (2 nos.- 400 watts with metal halide lights of Philips make) to be incorporated in design to light up the entire tower with throw from base. • The backlit portion of the monolith to be lit with sufficient numbers T5 (28 W) tube lights (Philips make) with electronic choke, mounted on MS tube frames with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • Steel structural frame to be installed on RCC foundations. Top and exposed sides of the foundation to be cladded in 18 mm thick black polished granite. • All work to be done in line, level and plumb, all complete with by works, as approved.
CANOPY FASCIA: 800 mm wide (in corporate colours on canopy vertical faces.Supplying & Installing Canopy Fascia with following specifications: • 900 mm height canopy fascia with PVDF coated 4 mm thick ACM sheet cladding duly CNC machine machine routed and fold as per drawing mounted on 150 mm depth box made out of 25 mm x 25 mm MS hollow pipe frame with powder coating and top GI sheet cover. • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice duly pasted on ACM in required size & shape (colour scheme and design to be approved) on mild steel framework with part backlit for company logo and name. • LED Lighting modules or encased LED light strips (Osram / Neenja / equ.) and power supply. • The letters sh all be in 30 mm thick Acrylic/ PC duly CNC Routed in require shape & Size as per direction of concerned engineer. • Structural frame to be welded rigidly/ Bolted to the structural member of existing canopy structures. • FASCIA BAND: 300mm in ht. Acrylic / PETG thermoformed band with necessary support covered with vinyl of approved make with the provisions of illuminations during night with LED of approved make. • COMPANY LOGO: 900mm in ht. Acrylic / PETG (Eastman / Bayer / equ.) thermoformed shape & letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on all 4 sides. • Company Name: 450mm in ht. 040 white Acrylic / PETG thermoformed letters (as per art work) covered with vinyl of approved make with the provisions of illuminations during night. Logo on front right as per DWG. • Canopy fascia to be made in 12 m. (min.) long straight panels factory plan/processed at converters factory and assembled/installed at site. Corner piece (1 metre both sides) on both sides (as required), also to be factory plan/processed/assembled and installed at site. Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb. • Backlit section of the fascia shall be of 4 meters length and one/ two logos (depending on design) and shall have sufficient number of LED/T5 (28 W) tube light with electronic chokes mounted with plastic holders to structural frame. • The top of the fascia shall have 4 mm thick ACM with hinged GI service door in backlit part. The back of the fascia to have 18 gauge GI sheets. • Multi-strand copper conductors with PVC insulation to be used. • The bottom and top of the fascia shall have a white ACM trim to cover the gap between the canopy and fascia. • The contractor should make suitable fixing arrangement, which should be duly vetted by a certified structural engineer as per the actual dimensions of the canopy structure.
CANOPY COLUMN CLADDINGSupplying & Installing Column Cladding: • Using PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond), mounted on box made out of 20 mm x 20 mm MS square pipe hollow section with powder coating. • Backlit design band in the centre in PET G (Eastman / Bayer / equ.) with yellow vinyl, LED lighting modules (Osram / Neenja / equ.) and power supply according to the design. • The structural framework shall be fixed securely to existing canopy column by welding at site. • ACM panel fixing to ensure consistent joint gaps and panel size. • All grooves shall be sealed with sealant material of approved colour, all complete with by works, as approved.
SAFETY SIGN200 mm X 200 mm Supplying & Installing safety sign stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on column cladding.
DISPENSER STICKERSupplying & Installing stickers of retro reflective vinyl (Avery / 3M / equ.) as per design pasted on dispensers.
SPREADER450 mm X 450 mm Supplying & Installing Pump Spreader: • Made of 25 mm x 25 mm MS hollow pipe frame box with powder coating & cladding on both sides of PVDF coated 4 mm ACM (Alstrong/ Aludecor/ Alucobond) • CNC Router cut graphics in 040 white acrylic with LED modules (Osram / Neenja / equ.) for lighting • Spreader frame to be fixed securely to canopy columns with box & cap arrangement. • Sufficient no. of LED/ CFL lights and electronic chokes fixed with plastic holders. • Multi-strand copper conductors with PVC insulation to be used. • AII work to be done in line, level and plumb, all complete with by works, as approved.
CRASH GUARDSupplying & Installing 80mm dia MS pipe or as per design with two coat of zinc oxide primer and metallic paint as per the design.
BUILDING FASCIA700 mm wide on top of building faces in elevation.Supplying & Installing Building Fascia with following specifications: • 4mm thick ACM (Alstrong/ Aludecor/ Alucobond) cladding in a combination of corporate colours with the use of Retro Reflective Sheeting (Avery / 3M / equ.) Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape (colour scheme to be approved) on mild steel framework. • Structural frame to be fasteners/ Nut Bolted to the building walls with dash fasteners and leveling 'arrangement. • Building fascia to be made in maximum length of straight panels (with minimum no. of joints) straight panels factory plan/processed at converters factory and assembled/installed at site. • Corner piece (1 metre both sides) on both sides, also to be factory plan/processed/assembled and installed at site. • Only bottom trim and top flashing is to be Plan/processed and installed at site. • All work to be done in line, level and plumb, all complete with by works, as approved.
MANDATORY SIGN300X 450mm (on toilets) & 300X 600mm (in compressor and LCV area) - rectangular or trapezoidal in shape.Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved.
DIRECTION SIGN400 mm X 1000 mm heightSupplying & Installing Entry-Exit sign: • Made out of 25 mm x 25 mm MS hollow pipe frame box with powder coating and covered with 4 mm thick ACM sheet (Alstrong/ Aludecor/ Alucobond) and CNC router cut graphics in 040 white acrylicwith LED modules (Osram / Neenja / equ.) for lighting and base foundation. • The sign frame to be fixed securely to CC foundation. • The CC foundation shall have 8mm thick polished black granite tiles cladding on top and all exposed side surfaces. • All work to be done in line, level and plumb, all complete with by works, as approved.
HOARDING3000 mm wideSupplying and installing Printed Flex sheet (make LG / 3M / Avery) with approved Art work (suitable for front lit) to be Fitted to the steel sheet of existing Hoarding structure in aluminium frame using Klick Rail System & as per direction of concerned Engineer/ client.
SPOT HALOGEN LIGHTSAt an interval of 2 m C/C on top of existing steel hoarding. Supplying and installing Spot halogen lights (150 watts of Philips make) at an interval of 2 m center to center on top of existing hoarding including supply with steel bracket and laying of cable upto electrical panel of Electrical room (in Utility building) complete in all respect.
Part V- Electrical Works
A. Electrical Supply
415 V LT PDB and APFC Panel
Design, engineering, manufacture, shop testing, supply including packing and forwarding, transportation, delivery at storage and from storage to site of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A..
LIGHTING DISTRIBUTION BOARDS
Design, engineering, manufacture, shop testing,supply, 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Supply including packing and forwarding, transportation, delivery at storage of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Design, engineering, manufacture, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site of following :
Supply of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Design, engineering,supply including packing and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring , test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Design, engineering, shop testing, Supply , packing and forwarding, transportation, delivery at storage and from storage to site lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Design, engineering, shop testing, Supply, packing and forwarding, transportation, delivery at storage and from storage to site latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Supply of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Supply of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Supply of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Supply and Fabrication of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Supply of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Supply of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Design, manufacture, testing at works, supply, storage, transportation to site of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Supply of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Supply of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Supply of Main Distribution Frame - 12 pair
Supply of LAN switch with single incomer and min 10-port out going port complete in all respect.
Supply of required material for Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Supply including packing and forwarding, transportation, delivery at storage to site of 11 kv/433 V outdoor type, 3Ph, 50Hz,copper wound, Dyn11, ONAN distribution transformer with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Supply of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating, pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
Supply, of 11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Supply of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
Supply of Tools and Instrument as per Annexure - A of scope of work.
Flame Proof Tool Box Set as per Annexure - A of scope of work.
B. Erection, Testing & Commissioning
415 V LT PDB and APFC Panel
Erection, testing & Commissioning of electrical panels :
415 V, 36 KA single front type indoor PDB to receive input power consisting of bus bar chamber, cable alley,outgoing with Fuse complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliaries with FLP LCS(Local Control switch) for tripping the main incomer of PDB etc complete in all respects as specified in technical specification, data sheet & SLD no. MEC/0030/05/E9/E/1081A & as per standard Specification. Dual incomer of 250Amp & 125Amps (with Single phase preventer & VMR) 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with necessary(Electrical & Mechanical) interlock through 4P power contactors and PLC with 8 DIs and 8 DOs. Buscoupler of 125A 4P power contactor. Outgoing with 01 no. 125 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 02 nos. 80 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 08 no. 63 Amp TPN MCCB (with TM based O/C,S/C & E/F RELASE). Outgoing with 03 nos. 32 Amp TPN MCCB (with TM based O/C & S/C RELASE). Outgoing with 3 nos. 80A Fuse and 3 nos. 32A TPN MCB. Outgoing with 3 nos. 80A Fuse and 3 nos. 20A DP MCB.
Floor mounted APFC Panel of 40KVAR capacitor bank in steps of (1x10)+(4x5)+(4x2.5)KVAR capacitors consisting of bus bar chamber, cable alley incoming (MCCB), outgoing feeder (MCBs) as specified in tender specification & SLD no. MEC/0030/05/E9/E/1081A.
LIGHTING DISTRIBUTION BOARDS
Erection, testing & Commissioning of 415V/240V lighting/power panels, Surface/Recess mounting type in weather/flame proof (with hinged cover) sheet steel enclosure of approved make having 4 Pole MCCB(LSIG)/RCCB (MCB + ELCB) as incoming and SP/DP/TP MCB (9KA type) for out going circuit complete with wiring,indication lamp, ammeter etc including all labour and materials as per specification, data sheet and the direction of Engineer-in-charge.
Surface/Recess mounted Lighting Panel (I/E-LDB) for Building Lighting and Power point consisting two incomers of 63 Amps and 32 Amps (300mA sensitivity) 4/2 Pole RCCB (Grid+Invertor supply) along with necessary interlock through contactor with two isolated Cu busbar and 6 Nos. 16A DP MCBs, 10 Nos. 10A DP MCBs & 08 Nos. 6A DP MCBs as out goings complete with ammeter ,indication lamp etc including all labour and materials as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081B and the direction of Engineer-in-charge.
Outdoor Lighting Panel (O-LDB) consisting of 63 Amp (300mA sensitivity) 4 Pole RCCB as incomer and 12 nos. 20A TPN MCBs,06 nos. 16A TPN MCBs as out goings complete with Contactor(4P ,63A Contactor with 24Hrs timer), timer, A/M switch, PB with timer and 5 Nos. 20 Amp TPN MCB, 2 Nos. 16A TPN MCB are without timer etc indication lamp as per specification, data sheet & SLD no. MEC/0030/05/E9/E/1081C and the direction of Engineer-in-charge.
INVERTER SYSTEM
Erection, testing & Commissioning of 1100VA sine wave Inverter system with 1x150Ah Battery backup, completely maintenance free lead-acid battery along with Battery stand for critical lighting in control room building & outdoor area (Make Inverter: Su-Kam, Genius, Microtek, Battery: Exide, Amaraja).
UPS SYSTEM
Erection, testing & Commissioning of following :
Laying of 1.1kV, Aluminium/Copper conductor, XLPE/PVC insulated, extruded PVC inner sheathed, PVC outer sheath and G.I. armoured FRLS Power and HR+FRLS Control Cable confirming to specification of below mentioned sizes as per datasheet, specifications of this tender and as per approved vendor list. Note that these quantities are approximate and payment shall be made for actual equipment / materials installed by the Contractor as part of permanent installation based on Issued for Construction drawings. Actual billing shall be done only on permanently installed quantities and not on supplied quantities. Any balance material supplied by Contractor but not permanently installed at site shall be taken back by Contractor and shall not be billed to Purchaser and/or Consultant. Contractor shall consider all associated work as indicated in respective installation standard drawings, scope of work and as per the directions of the Engineer-in-charge.
3.5Cx 120 mm2 A2XFY.
3.5Cx 50 mm2 A2XFY.
3.5Cx 35 mm2 A2XFY.
3.5Cx 25 mm2 A2XFY.
4Cx10 mm2 2XWY.
4Cx 2.5 mm2 2XWY.
3Cx 2.5 mm2 2XWY.
7Cx 2.5 mm2 2XWY.
Erection, testing & Commissioning of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, test link, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover(MS)/ SFRC cover as per std drg
Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover (MS)/ SFRC cover as per std drg
GI Strip (50X6) mm
GI Strip (25X3) mm
Copper Strip (25X6) mm
No. 8 SWG Solid GI Wire
Static discharge retractable earthing reels for LNG Tanker Earthing with approx. 15 mtrs cable and heavy duty clamp suitable for tanker earthing along with canopy suitable for outdoor installation and all other necessary hardware to make it complete in all respect for earthing/grounding of LNG tanker
OUTDOOR LIGHTING
Erection, testing & Commissioning of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 72 W LED luminaire with flame proof control gear/JB (Model no. WG-1240 of Sudhir make or equivalent)
Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting(CRS-1273, 1 x LED, 90W)of Sudhir make or equivalent, juction boxes etc. as requried.
Street lighting pole 6mtr high GI octagonal pole (Type BOP-6030 of Bajaj make or equivalent) complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing (MEC/SD/05/E9/77/04) & specification (MEC/TS/05/E9/077B).
Air Conditioners
Erection, testing & Commissioning of latest model (5 stars BEE certified ,Inverter AC) 2.0 T split AC complete with remote, MS Stand for outdoor unit etc.
Erection, testing & Commissioning of Flame Proof Welding Socket including structure,Civil Foundation and hardware etc complete in all respect.
Flame proof type 63 Amp. Welding socket
UPVC Pipe
Erection, testing & Commissioning of UPVC Pipes in required length for fixing on steel, concrete or similar sructure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, installation of clamps, small iron structures, spacers, seats, plugs, bushings etc. and all other materials as per approved drawings and directions of Engineer-In-Charge.
Cable Tray
Erection, testing & Commissioning of Hot Dip Galvanized Perforated Type, 50mm height, 2.5 mm thick sheet steel & galvanized (86 microns) cable trays (as per IS 2629) of required sizes including tray cover, bends, tee, crosses, horizontal and vertical splices , structural support(suitable for three/four tier),hardware,civil work etc,complete in all respect.
50mm wide
150mm wide
300mm wide
Erection Material
Installation of MS base frame support for switch gear and bracket for misc. electrical equipment, cable and cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, installation of necessary anchor bolts and grouting etc, applying one coat of anti rust primer, two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
Safety Items
Installation of the following including the necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
Shock hazard charts complete with frame and glass
First Aid Boxes
Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket, stand etc With Mfg. Test certificate.
Caution boards including necessary clamps, bolts and other hardware.
As built Single Line Diagram complete with frame and glass including hardware etc.
Insulating Mats
Laying of Insulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
11 KV grade of 2.5 mm thick
Erection, testing & Commissioning of point wiring as per details in construction drawing & specification includes PVC conduits in ceiling, complete wiring including Wiring for main/ submain from DBs to switchboard and from switchboard to light/power points with 6/4/2.5/1.5 sq.mm. FR PVC insulated copper conductor multi starnd wire in PVC conduit in recess/ trench as required, switch boxes & switches (ANCHOR ROMA make or equivalent) for following items-
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-36 -CDL of CG make or equivalent).
Surface/ recess mounted LED light fixrure with LED lamp (type LCTL-18 -CDL of CG make or equivalent).
Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 of CG make or equivalent).
Exhaust fan (Industrial type 300/450 mm) with louvers,950 rpm,55watt with flap.
Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. (Preferred Make: Baliga, FCG, CGL, Prompt)
Socket outlet (5/15 Amp combination) of ANCHOR ROMA make or equivalent
20 Amp sheet steel enclosed industrial type socket with 20 Amp DP MCB for AC.
Ceiling fan with electronic regulator ( Energy efficent, 50W, 1200 mm sweep)
Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
Wall mounted fixture above Mirror/Wash basin of 10/15W LED etc complete in all respect.
SOLAR SYSTEM FOR OUTDOOR EMERGENCY LIGHTING
Erection, testing & Commissioning of Solar Street lighting system complete with GI pole and GI mounting bracket, control gear box, internal cable from fitting to junction box, and 15W LED fixture (Fixtures Bajaj Make or equvalent and Battery make Exide, Amron etc), three days battery backup with solar Module, earthing, electronics, dusk-dawn operation etc including pipe inserts for cables and connecting work and commissioning spares as required, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Nominal height of GI pole shall be 6m. Work to be completed in all respects.
ELECTRICAL ACCESSORIES
Installation of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays including all labour and materials complete as required and as per directions of Engineer-In-Charge.
Telephone & LAN
Erection, testing & Commissioning of telephone sockets (Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Erection, testing & Commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
Laying of 2 pairs,0.61mm, Telephone Cable/Wire, including accessories etc as required.
Laying of UTP cable (CAT 6), Make : D Link/Amp/Lucent
Erection, testing & Commissioning of Main Distribution Frame - 12 pair
Erection, testing & Commissioning of LAN switch with single incomer and min 10-port out going port complete in all respect.
Construction of Cable pit with pit cover (SFRC cover HD-20 of IS-12592) including civil works repair, concrete wall/brick wall & its materials, cable conduits interface & its water sealing, cable support structure including all labour and materials complete in all aspect as per approved drawings and directions of Engineer-In-Charge.
500X500(of inside clearance)X 600(Depth)
750X750(of inside clearance)X800(Depth)
1000X1000(of inside clearance)X1000(Depth)
DISTRIBUTION TRANSFORMER
Erection, testing & Commissioning of 11 kv/433 V outdoor type, 3Ph, 50Hz, copper wound, Dyn11, ONAN distribution transformer r with off-load tap changer complete with all accessories as per REC specification 11/1976 and/or IS 2026/1180. and latest amendments there of and first oil filled. Termination arrangement for HV side : HT bushing & LV side Cable end box/Terminal box of following rating (Make of Transformer shall be approved from State Electricity Board/MECON.)
Erection, testing & Commissioning of all the items listed below, all miscellaneous materials etc as required to complete the HT & LT installation as per the tender. (All electrical equipments shall be approved from State Electricity Board/MECON.)
Double pole Structure with MS joist ISMB 200 x 100 mm, 9 m long complete with 100 x 50 mm MS channels of required length and size ; 11 kV 3 Ph. horizontal Gang operated Air Break switch, DO fuse, lightning arrestors of suitable ampere rating;pin insulators, disc insulators, operating rod, handle, locking arrangement, copper wire for jumper connection, stay set complete with all accessories etc as required inclusive of paint (two coats of primer & two coats of final aluminum paint) and concrete foundation.It shall be complete in all respect as per Mecon/SEB std.
11 kV, ACSR weasel conductor, insulator, cross arms, all necessary hardware as required for stringing between State Electricity Board Double pole and consumer double pole structures.
Chain link fencing of (height 2.5 m) for the sub station area with ISA 50 x 50 x 6 mm angle and 4 mm thick welded wire mesh and 1 no. gate ( 3x3 mtr.) complete with all material, welding and labour etc (20 mtrs/set)/ As per SEB std.
40 mm blue granite metal for spreading in the fenced area .
GAS GENERATOR SET
Erection, testing & Commissioning of Min 58.5 to 63KVA KVA Prime Power Gas Genset including AMF Panel with auto start/stop through Pressure transmitter switch as well as through grid failure with MCCB of suitable rating, suitable size of Power & Control cables, hook-up Pipe (Approx. length 50Mts.) from existing BOG management skid of pressure range 1-2 bar, Metering, PRV, Piping, dial Pressure Gauge, Flanges, etc with Ethernet communication& Latest CPCB norms as applicable during supply of equipment complete in all respect suitable for Greenfield LNG station.
All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for LNG station. However the official fees towards the approvals shall be reimbursed by the client.
Kindly quote in Percentage in M column on total Estimate Amount of Percentage part (Civil Work SOR Part -D (item CIV-01 to CIV -48) refer sheet4. Note: Bidders shall quote percentage in plus ( '+ ') or minus (' - ') in column M by which total estimated price in the Sheet4 shall be increased or decreased to arrive at bidder‘s quoted price (excluding GST) for Sheet4. Bidder's quoted item rates shall be arrived by applying offered percentage on estimated rates of all BoQ items given in Sheet4.
Sacheti Infratech Private Limited (BID ID -820327)
M/s. JYOTI SARUP MITTAL (BID ID -819965)
M/S JAI MAA CONSTRUCTIONS (BID ID -820404)
ENTECK TRADE LINK (BID ID -820339)
SANJIV SAHAI SHARMA (BID ID -820171)
SANJIV SAHAI SHARMA (BID ID -820171)
ENTECK TRADE LINK (BID ID -820339)
M/s. JYOTI SARUP MITTAL (BID ID -819965)
RGI ENTERPRISES (BID ID -816410)
M/S JAI MAA CONSTRUCTIONS (BID ID -820404)
SANJIV SAHAI SHARMA (BID ID -820171)
Sacheti Infratech Private Limited (BID ID -820327)
M/s. JYOTI SARUP MITTAL (BID ID -819965)
RGI ENTERPRISES (BID ID -816410)
M/S JAI MAA CONSTRUCTIONS (BID ID -820404)
M/S JAI MAA CONSTRUCTIONS (BID ID -820404)
SANJIV SAHAI SHARMA (BID ID -820171)
ENTECK TRADE LINK (BID ID -820339)
M/s. JYOTI SARUP MITTAL (BID ID -819965)
RGI ENTERPRISES (BID ID -816410)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .