Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 Cr+₹6.8 L (5.46%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹1.3 Cr+₹6.8 L (5.46%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.4 Cr+₹11.2 L (9.03%)Rejected-Finance | ₹1.4 Cr+₹11.2 L (9.03%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.4 Cr+₹14.4 L (11.6%)Rejected-Finance | ₹1.4 Cr+₹14.4 L (11.6%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.4 Cr+₹18.4 L (14.8%)Rejected-Finance 1 204 LOWER GROUND FLOOR SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹1.4 Cr+₹18.4 L (14.8%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
12 Aug 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
SPL REPAIR OF AOC SINGLE LIVING ACCN (P-247) AT CVD UNDER GE (WEST), DELHI CANTT-10
2020_MES_357702_1
CWE/WEST-07/2020-21
Open Tender
Civil Works
Item Rate
240 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (WEST) DELHI CANTT
₹2.9 L
Yes
26 Sept 2020
2 Jul 2020
14 Aug 2020
2 Jul 2020
12 Aug 2020
31 Jul 2020
Amount
Demoliton of stone slabs & tiles of any thickness in floors, aprons laid & bedded and pointed in any mortar complete all as specified and directed.
M & L machine cut kota stone slab flooring 20-25mm thick in floor over cement screed 20 mm thick in Cement Mortar 1:6 laid & jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing and marble piece of size 10 cmx10 cm fixed at junction of kota slabs flooring complete all as specified and directed. Note Marble measured and paid separately
S&F 20-25 mm thick marble white (Makrana) work (table rubbed and polished) on bar counter, cooking plateform, pillars, cill, jambs, steps and like over 15 mm thick in Cement Mortar 1:6 including pointing in white cement(1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
All as per item No 2 above but on vertical surface skirting,riser of steps & pillars & likes over 15 mm thick rendering in Cement Mortar (1:4) complete all as specified and directed.
M&L 60 mm thick coloured cement concrete interlocking paver blocks hydraulically pressed of compressive strength not less than 400 Kgs/sqcm, laid dry including vibrating the pavers and joints filled with dry sand in repairs complete all as specified and directed by Engineer-in-Charge.
M & L for sand filiing/sand cushion under the floor or in foundation including watering and consolidation complete all as specified and directed.
S & F aluminium frame powder coated for door , windows, ventilaors with one or more rebate including joining cleats for fixing etc complete all as specified and directed.
S & F powder coated aluminium windows and ventilator shutters, fixed type with sash bars, aluminium section 0.55 kg/M including necessary joing cleats , glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and directed.
S & F Powder coated (minimum thickness of powder coating 50 micron) aluminium partly fixed and partly sliding shutter( Size 45x15mm) three track, two shutter with 4.8mm tinted glass and one with stainless steel wire cloth of 0.36 mm dia & average width of apertuer 1.40 mm & sliding section conforming section of Make Jindal Cat No 20814 or equivalent in Indal/ Hindalco complete (Size of Section 92.00x 45.5) and frame (Chowkhat) size 101.60x 44.45 x1.90 mm thick complete all as specified and directed Note : All Necessary fitting including quatoted rate by Contractor
S&F 4.8 mm thick figured glass pane figured glassy with oil putty or wooden beading in square n exc 0.50 sqm in each pane complete all as specified and directed.
S & F Powder coated (minimum thick ness of powder coating 50 micron) aluminium partly fixed and partly sliding shutter (Size 45x18mm) two track track, two shutter having stainless steel wire cloth of 0.36 mm dia & average width of apertuer 1.40 mm & sliding section conforming section of Make Jindal Cat No 20965 or equivalent in Indal/ hindalco complete (Size of Section 61.850x 45.5) and frame (Chowkhat) size 63.50x 38.10 x1.50 mm thick of Make Jindal Cat No 20073 or equivalent in Indal/ Hindalco complete all as specified and directed. Note : All Necessary fitting including quatoted rate by Contractor
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S &F 3mm thick sheet glass, ordinary quality and glazing with oil putty n exc 0.50 sqm each complete all as specified and directed.
M & L for ( 600x600) mm and thickness of tiles not less than 8 to 10 mm vitrified tiles of approved colour laid in floors set and jointed in neat cement slurry and pointed in coloured cement to match, Including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and directed
M& L for joint free non skid ceramic tiles ( 600x600) mm 7 to 08mm thick ( Square/ rectangular ) area of each tiles exceeding 0.36 sqm and n exc o.42 sqm in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match over including 15 mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed..
S&F, Glazed ceramic tiles Coloured 300X600X 7 to 8 MM thick Maniera (High lighter/ Digital 01, Light and dark), Bllita pattern from Somany Glosstra plus or eqiuvalent in Kajaria/ Cera/ H&R Johnson/ Spartek/ Unistone in wall/dado etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including10mm thick backing coat in Cement Moartar 1:4 complete all as specified and directed.
S&F 16 to 18 mm thick granite ( of any type) work (table rubbed and polished) on bar counter, cooking plateform, pillars, cill, jambs, steps and like over 15 mm thick in Cement Mortar 1:6 including pointing in white cement (1:2) using marble dust with admixture of pigment to match and mirror polish complete all as specified and directed.
S&F 20 to 25 mm thick Kota stone in Single piece in length and suitable width of tread/riser (One shade only, Different stone & different shade not accepted) other than on ,steps of staircase, jambs, pillars, windows cills and cooking plateform, and like over 15 mm thick rendering in Cement Mortar 1:4 including pointing in white cement(1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
S&F 20 to 25 mm thick Kota Stone single piece in length and suitable width (One shade only, Different stone & different shade not accepted) table rubbed and polished on wall lining ( riser) and like over 25 mm thick rendering in Cement Mortar 1:3 including pointing in white cement(1:2) using marble dust with admixture of pigment to match complete all as specified and directed.
Dismantling of brick tiles or terracing tiles single layers as on roof complete all as specified and directed
Demolition of mud in roof any thickness including plastering and leeping etc complete all as specified and directed.
M & L PCC (1:2:4) type B-1 (using 20 mm graded stone agg) as in roof finished even & smooth without using extra cement etc complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 with using WPC liquid 200ml/per bag of cement and paid separately as per manufacture direction in cement complete all as specified and directed.
M&L for applying a coat of bitumen primer confirming @ 0.50 ltr/ Sqm on prepared surface of plaster and applying a coat of hot blown bitumen 85/25 gde @1.2 kg/sqm and applying APP based Polymeric membrane along with torch application minimum weighting 3.5kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric(wt.not less than 150 grm/ sqm) and sealing joints by torched application complete all as specified. over the APP membrane granular finish apply semi hot blown bitumen 85/25 @0.50 kg/sqm and dusting over the bitumen coat complete all as specified and directed. Make: Ms Sika India Pvt Ltd/ Ms Fosroc Chemicals/ Ms STP limited/ Ms IWL India limited/ Ms Tiki Tar Danosa (India) Pvt Ltd/ Ms Torchtar Membrane & Bitumen Pvt Ltd
M & L for 20-25 mm thick PCC tiles (250x250) mm of size laid over and including 15 mm thick screed bed in Cement Mortar (1:4) mortar and Joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement etc complete all as specified and directed.
M & L for chipping of spelled and loose concrete and cleaning rust from reinforcement by sand brushing scrubbing down concrete surface with wire brushes cleaning with water allowed to dry applying a layer zinc rich epoxy primer as anti rust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adhesive on complete exposed surface of concrete and provide guniting in two layre over steel welded mesh 2 mm dia of wire and total aperture 50 mm, thickness of gunite n exc 25 mm thick ( average thickness) using cement mortat 1 : 3 with OPC 53 Grade cement mixed with polycrete admixture @ 2 % by the weight of cement or as per manufacturer’s instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometric in cement mortar 1 :4 to match with slabs, chajja, fins, facias, parapets, columns and beams etc complete including necessary scaffolding, shuttering necessary, chased to brick work or RCC members at any height up to five storey buildings and including removing of small trees, shrubs etc complete all as specified and directed. Note : steel welded mesh to be welded with existing reinforcement. The cost of welded meshis to be welded with the existing re- inforcement is deemed to be included in the quoted rate. Make: Sika/ Fosroc/ Pidilite
Demoliton of reinforced cement concrete of any description & in any position not otherwise specifically provided complete all as specified and directed.
M&L RCC M-25 (Design mix ) in chajja complete all as specified and directed.
M&L, RCC M-25 ( Design mix) using 20mm graded aggr in roof slab, floor slabs, landings etc complete all as specified and directed.
Form work to soffits of roof slabs, floor slabs, landings etc & similar work n. exc 200mm thick with rough flat finished surfaces of concrete horizontal or sloping complete all as specified and directed.
S&F MS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending, hooking etc and binding with MS wire 0.9mm dia(annealed) complete all as specified and directed.
Taking down chowkhat or frame not exc 1.50 sqm with shutters (without taking off shutters from the frames) each complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) exc . 1.50 sqm but not exc 4 sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 sqm and n.exc 2 sqm each complete all as specified and directed.
S&F fibre glass reinforced plastic (FRP) door frame shall be three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulde with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided at the bottom to steady the frame as per specification & drawing complete all as specified and directed.
S&F FRP door shutter 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer made with retardant grade unsaturated poyester resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels and confirming to IS 14856-2000 supply and fixing in the frame at site complete all as per specification & drawing complete all as specified and directed.
S&F 30mm thick flush shutter, solid core construction,with block board core &plywood face panels,commercial type on both sides complete all as specified and directed.
S&F stainless steel butt hinges ,medium weight, cold rolled, of size 100mm complete all as specified and directed.
S&Faluminium alloy, anodised, sliding door bolt with hasp & staple (bolt type) of extruded section of size 300mm long complete all as specified and directed.
S&F extruded aluminium alloy handles, fabricated type,anodised of size 150 mm complete all as specified and directed.
S&Faluminium, anodised, barrel tower bolts of extruded section of size 150 mm complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 25 mm complete all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 50 mm complete all as specified and directed.
S&F GI tubes medium grade galvanized with all fittings and fixed complete to wall & ceiling or laid in trenches 15mm bore complete all as specified and directed.
S&F GI tubes medium grade galvanized with all fittings and fixed complete to wall & ceiling or laid in trenches 20mm bore complete all as specified and directed.
S&F GI tubes medium grade galvanized with all fittings and fixed complete to wall & ceiling or laid in trenches 25mm bore complete all as specified and directed.
S&F GI tubes medium grade galvanized with all fittings and fixed complete to wall & ceiling or laid in trenches 50 mm bore complete all as specified and directed.
S&F Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 25mm dia complete all as specified and directed.
S&F Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20mm dia complete all as specified and directed.
S&F Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 50mm dia complete all as specified and directed.
S & F in repair vitreous china wash down water closet pan , white (Pedestal pattern) including PVC seat cover complete all as specified and directed. Make: Hindware cat No 20012 ( P-18) universal type of size (57x46x38)cm or equivalent in Parryware/ Jaguar/ Somani/ Cera
S&F in repairs vitreous china squating pan 'Orissa' pattern size (580mm x 440) ( ACU Pan) mm white, with integral foot rest (excluding flushing cistren and flush pipe) complete all as specified and directed. Make: Hindware Cat No 20076 or equivalent in Parryware/ Jaguar/ Somani/ Cera
S&F in repairs PVC valveless, syphonic action type, flushing cistern of size (47.6x15x30) cm, low level , white of 10 ltr of capcity including inlet , ball valve, float & handle including brackets, PVC band and connection complete all as specified and directed.
S&F in repairs counter sunk oval shape vitreous china wash hand basin of size 550x460/550x430 mm complete all as specified and directed.
S&F in repair vitreous china urinal half stall type of size (420x395x635) of ivory colour including spreader with union for discharge and waste pipe complete all as specified and directed.
S&F in repairs long body Bib cock ,cast copper alloy Chromium plated,fancy type, capstan head screwed down high pressure with crutch or butterfly handle for 15 mm bore complete all as specified and directed.
S&F in repairs light angular Stop valves/angle cock, cast copper alloy Chromium plated,fancy type, screwed down high pressure with crutch or butterfly handle for 15 mm bore complete all as specified and directed.
S&F in repairs stop valves, cast copper fancy type, chromium plated with long shank & cup ( concealed type) screwed down, high pressure with crutch or butterfly handle for 15 mm bore pipe complete all as specified and directed.
S & F in repairs pillar taps long neck cast copper alloy with capastone heads chromium plated screwed down screwed high pressure with or without lettered Hot & cold with long screwed shanks and ply nuts screw for iron pipe 15 mm dia complete all as specified and directed.
S & F PVC connection 15mm (bore) size with PTMT nuts of length 450mm completed all as specified and directed.
Supply and fixing in repairs CP brass shower rose with or without swivel joints, 150x150 mm size , single flow (ABS body chromium plated with grey face plate 0 with rubit cleaning system along with CP brass shower arm casted 190 mm flate shape for wall mounted shower with flange complete all as specified and directed. Make: Jaqur Cat part No ohs-35495 for shower rose and cat No SHA-CHR-483 for shower arm or eqivalent in GEM/ marc/ Jalangi
Taking down cement plaster/grit plaster/skirting ,racking out joint, hacking for key, scrubbing down with water etc on walls and ceiling rubbish off the premises complete all as specified and directed
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed. Note: Paymentfor providing grooves shall be made separately
Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed by Engineer-in-charge
M & L for rendering 10 mm thick in Cement Mortar 1:3 on ceiling finish even and smooth surfaces without using extra cement complete all as specified and directed .
M & L for rendering 15 mm thick in Cement Mortar 1:4 on brick work or concrete (external) surface etc including finished even and smooth surfaces without using extra cement complete all as specified and directed .
Supply only Liquid water proofing compound, complete all as specified and directed.
M & L for rendering 15 mm thick in Cement Mortar 1:6 on brick work or concrete ( internal) surface etc including finish even and smooth without using extra cement complete all as specified and directed.
Complete removal (Scrapping) and preparing the surface with sand papering of surface with the help of mechanized sanders of Berger Paints Xpress painting sanding machine or equivalent in Asian Paints/ Nerolac (having mechanical vaccum machine with bag for dust collection to make surface even and smooth) complete all as specified and directed by Engineer in charge.
M & L for 2 mm thick wall care putty on wall complete all as specified and directed.
M&L for two coat of OBD over newly decorated surface on ceiling including preparation complete all as specified and directed.
M&L for preparing newly plastered or unplastered or putty surface( complete removal by mechanized sanders machine) surfaces and applying two coats of acrylic oil emulsion all as specified over a coat of primer complete all as specified and directed.
M&L for preparing complete removal surface/newly plastered or unplastered surfaces and applying two coats of cement based paint over one coat of primer complete all as specified and directed.
M&L for two coats of weather proof paints including one coat of primer on exterior surfaces over 10cm width or girth complete all as specified and directed.
Demolition of Brick /stone walling built in cement mortor including all quoins, coping, arches pillars etc, rubbish of the premises complete all as specified and directed.
M&L, brick work with sub class'B' bricks, straight or curved on plan exc 6 M mean radius built in Cement Mortar 1:6 complete all as specified and directed.
Demolition of cement concrete in ground floor & paving n exc 15 cm thick below or above ground level complete all as specified and directed.
S&F, chequered cement concrete coloured and reflective type, plastic molds tiles 30cmx30cmx20mm/ 40cmx40cmx20mm) thick, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in Cement Mortar 1:6 with grey cement and pigments complete all as specified and directed.
M & L for 100 mm thick PCC 1:4 :8 type D-2(using 40 mm graded stone agg) as in sub base, finished even & smooth without using extra cement etc complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection using 40mm stone aggregate finised even & fair including making joints complete all as specified and directed.
S&F 150 mm bore spun cast iron pipe single socketed in any length with rubber ring joints fixed to walls including stack clamp of 50mm flat iron and 16mm dia mild steel stay including taking down eves gutter complete all as specified and directed.
S&F 150mm bore pipe cast iron bends any radius complete all as specified and directed.
S&F in repairs 100mm bore cast iron spun pipe soil, waste and vent pipe (sand cast) in any length with or without ears with cement joints fixed to walls complete all as specified and directed.
S& F in repairs 75 mm bore cast iron spun pipe soil, waste and vent pipe (sand cast) in any length with or without ears with cement joints fixed to walls complete all as specified and directed..
S&F Bends (any redius) dimishing pieces or tapers for 75mm bore of pipe complete all as specified and directed.
S&F Bends (any redius) dimishing pieces or tapers for 100 mm bore of pipe complete all as specified and directed.
S&F CI branch pieces,single(equal or unequal) ordinary or inverted( spigot or socket type) or with parallel branches with oval access door for 75mm bore of pipe complete all as specified and directed.
S & F CI branch pieces,single(equal or unequal) ordinary or inverted( spigot or socket type) or with parallel branches for 100mm bore of pipe complete all as specified and directed.
S & F stack clamps out of 50mm by 5 mm flat iron & 16mm dia mild steel iron stay including bolt & nuts & securing ends of stays to walls for 100mm pipe complete all as specified and directed.
S & F stack clamps out of 50mm by 5 mm flat iron & 16mm dia mild steel iron stay including bolt & nuts & securing ends of stays to walls for 75 mm pipe complete all as specified and directed.
M & L in repairs 75mm cast iron floor trap, with grating including jointing to waste pipe fixed in PCC 1:2 :4 type B-1 using 20 m graded aggregate complete all as specified and directed.
M & L for precast cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate ) for Man hole cover slab shelves, cooking plateform & similar articles with plain faces & set in cement mortar 1:4 complete all as specified and directed.
S&F 1000 ltrs capacity rotational moulded polythylene water storage tank(cylindrical vertical with closed top) hoisted and fixed in position including 20mm dia PVC float valve incl dismantling water tanks complete all as specified and directed..
Demoliton of cement concrete of any description & in any position not otherwise specifically provided complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 (40 mm graded stone agg) as in sunken floors complete all as specified and directed.
M & L rendering 10 mm thiick in CM 1:4 laid to achieve slope with two coat of teap create mixed (1:2) with cement slurry @500 gm per sqm as per manufactures's instruction in sunken potion of toilets, finished even and smooth w/o using extra cement and applying a coat of bitumen primer @0.70 kg /sqm and applying one coat of hot bitumen 85/25 gde @2.6 kg/sqm and one layer of 0.5 mm thick fibre tissue over it, a coat of hot blown bitumen 85/25 gde @2.6 kg/sqm over it and then applying one layer of 0.50mm thick fibre glass tissue and final layer of hot blown bitumen 85/25 gde @2.0 kg/sqm, complete all as as specified and directed.
M&L 75 mm thick PCC (1:4:8) type C-2 (40 mm graded stone agg) as in Sub base complete all as specified and directed.
M & L for precast cement concrete jallies, 35 mm thick in 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) & set in Cement Mortar 1:4 including all mouldings but excluding frame complete all as specified and directed.
Dismantling of plain or corrugated steel sheet, any gauge, thickness, including Nainital or similar patter roof coverage /wall cladding complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Excavation in post holes( or similar holes) each n exc 0.5cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around , in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for completed all as specified and directed.
S&F steel work in tubular trusses, purlins,rafters etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161 Gde St.- 240 complete all as specified and directed
M&L two coats of synthetic enamel paint over a coat of pink primer including prepration of newly wooden surfaces complete all as specified and directed.
M&L for one coat of synthetic enamel paint including prepration of old wooden surfaces complete all as specified and directed.
M&L one coat of synthetic enamel paint including prepration of old steel surfaces of any description, over 10 cm in width or girth, not otherwise described complete all as specified and directed.
M&L two coats of synthetic enamel paint over a coat of red oxide primer including prepration of newly steel surfaces of any description, over 10 cm in width or girth, not otherwise described complete all as specified and directed.
M & L of 1.25 mm thick mild steel plain black sheet in wall cladding, covering crample joint steel gate and similar work, cut to size, holes punched, including rounded screws, cut to size, edge beaded if directed, holes and punched including 40 mm lap joint or welded/riveted seams including bending, turning up, mitred angles, stopped ends etc as required complete all as specified and directed.
S&F 2nd class 35 mm thick hardwood glazed and skelton shutters ( Factory made) open rebated and prepared to receive glass / gauze etc ( with or without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc size of members of shutters as specified in SSRpart-i section 8 cluse 8.24(a) complete all as specificed and directed
M&L PCC (1:4:8) type D-2(40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F in repairs chromium plated self closing concealed urinal flush valve with wall flange complete all as specified and directed.
S&F,Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing & cnforming to Fe-410-W ( Gde- E 250 Quality 'A') complete all as specified and directed.
All as per item No 79 above but half brick wall in cement mortar1:4 complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid ,rounded or chambered put together with glue pinned at joints complete all as specified and directed.
S & F 2nd class hard wood 35 mm thick glazed and skelton shutters for windows and ventilator , open rebated & prepared to receive glass ,gauge etc. divided into squres,with plain,chamfered or rounded,mitred & rebated sash bars any numbers with cut and mitred beads for securing glass etc complete all as specified and directed.
Drilling Holes of 12mm dia, up to 100 mm deep holes in structural members at the interval of 300 mm in staggered manner or along the crack line as directed by the Engineer - in - charge in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Value) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fixing inside the hole by applying thyrotrophic epoxy putty to ensure complete sealing and allow to cure the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc., including all safety measure i.e (helmet, safety belt, scaffolding), insurance of the labour deemed quoted rate by contractor complete all as specified and directed for the followings:-
Column
M & L for grouting injecting two part, low viscosity, moisture insensitive injection-liquid, based on high strength epoxy resin Sikadur®-52 LP (IN) or equivalent in Fosroc/ STP limited by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 m Pas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F and should have below properties. Compressive strength >= 70 N/mm2 (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/mm2 (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/mm2 (after 7 days at +30°C cure) (According to ASTM D 638); Bond Strength ~ 10.8 N/mm2 (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/mm2 according to ISO 178. Seal the nozzle with Sikadur 31 or equivalent thyrotrophic epoxy putty after the refusal of grout material from the nozzle complete all as specified and directed for the folowings:- Note: leakage through other nozzle or cracks are required to be monitored while grouting and making good match with existing surfaces and such points to be sealed as and when required without any extra cost including all safety measure i.e (helmet, safety belt, scaffolding), insurance of the labour deemed quoted rate by contractor
Column
M & L for Clean excising reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt (chipping unsound week/loose concrete /cover of reinforcement etc, complete and proving, applying two coats of alkaline rust converting primer Sika RustOff-100 or equivalent in Fosroc/ STP limitedwith a coverage of 350gm/sqm on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, in soluble and adherent protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. including all safety measure i.e (helmet, safety belt, scaffolding), insurance of the labour deemed quoted rate by contractor complete all as specified and directed for the followings:-
Column
Providing and application of zinc rich epoxy anticorrosive protective coating for rebar corrosion protection system Sika Friazinc R® or equivalent in Fosroc/ STP limited in 2 coats of 0.4 kg/m2. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78 complete all as specified and directed for the followings:-
Column
M & L Drilling & rebaring of 12 mmm dia x 120 mm deep, additional corrosion resistant hot dip galvanised steel rebar Fe415 or height grade as per required diameter in various structrural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive Sika AnchorFix - 2+ Tropical or equivalent in Fosroc/ STP limitedcomplete all as specified and directed.
Impregnating cream for injection into masonry or concrete wall 230 mm thick against capillary rising humidity. Rising bar super strong ( Product No 201) of chowgate building chemicals or equivalent/Pidilite/Dr Fixit/Sika/FOSROC complete all as specified and directed. (a) The surface must be sound, absorbent, clean, free from dust, oil, paint, curing agents, loose cement or lime plaster & concrete, debris or any separation layers. (b) The plaster must be knocked off at least 50 cm beyond the visibility penetrated area. (c) Damaged mortar jointd are to be scraped out to a depth of approximately 2-3 cm. All sharp edges/joints need to be levelled loose concrete to be removed. (d) Drilled bore holes at ground level horizontally. The boreholes drilled horizontal into masonry. (e) The hole shold be drilled until a depth of approx 5 cm ( for a 6 cm thick wall ) before the the end of the wall is reached. The bore holes shold have a diameter of 12 mm upto a maximum of 15 mm and should be spaced approx 100 to 120 mm apart and the verticle offset is 6 cm max. (f) Before inserting Risingbar Super Strong or equivalent the boreholes must be cleaned from boring dust by using air pressaure. It is not necessary to pre wet the borehole. (g) For applying of RisingBar Super Strong or equivalent the dosing system inserted as far as possible into the boreholes. While dosing the products uniformly, the injection nozzle is pulled out leading to a completely filled borehole ( h) Treatment of highly absorbent masonry might require repeated filling of the bore after 24 hours. Depending upon extent of damage, RisingBar Super Strong or equivalent cab re injected into the same hole after 24 Hours. Depending on absorbency, application or masonry thickness 0.1 to 0.15 litre/M with 10cm wall thickness.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings) and deposit the same to MES Store and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specified and directed.
M&L for concealed point wiring with PVC FRLS insulated multi stranded unsheathed cable 1.5 sqmm size with stranded copper conductor, 1100 volts grade conforming to IS-: 694 drawn in and including concealed PVC rigid conduits 20 mm dia including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with concealed sunk in pressed steel terminal boxes of 1.6mm thick factory made and painted with stove enameled black paint covered with 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified and directed for the following :-
One light/fan/bell point controlled by one way switch 5 amps.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
One light controlled by two way switch 5 amps.
All as per item No. 128 above but with 2x2.5 Sqmm and 1x 1.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed.
S&F in repair switch piano type 5 amps single pole one way complete all as specified and directed.
S&F in repair switch piano type 15 amps single pole one way complete all as specified and directed.
S&F in repair socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F in repair socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F in repair 2 way switch complete all as specified and directed.
S&F in repair ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S & F LED bulb of 7 watt complete all as specified and directed.
S&F in repair bulk head LED light fitting 10 Watt deep drawn anodised aluminium body, epoxy white powder coated, heat resistant prismatic glass cover with gasket complete all as specified and directed. Make: Havells Cat Part No- LHEOAOP7UZ6W010 or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
Supply, laying and drawing in and including taking down 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection complete all as specified and directed.
S & F in repair Decorative wall mounting chrome finish fixture with textured glass suitable for 40 watt mini GLS lamp complete all as specified and direccted. Make: Havells cat part No:LHFHDAC2TB1WO40 or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including replacement of ball bearing as requirment of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep & refixing on existing point complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and direccted. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and direccted.
S&F in repair double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘D’ curve, 10 KA breaking capacity, complete all as specified and directed.
S&F surface mounting 20 watt LED tube light fitting of 4 ft length connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed. Make: Havells Cat Part No- LUMILINEPLUSBS20WLED865SPCSS or equivalent in Philips/ Baja/ Crompton Greaves/ Benlo/ C&S Electric/ Polycab/ Halonix
S&F in repair MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in repair energy saving environmental friendly long life exclusive innovative die- cast alumonium flood light with high power LEDs as source suitable for highlighting architectural featers or area lighting 30 watt including screw nut bolt complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and direccted. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F metal type exhaust fan single phase 230/240V of 450 mm sweep including cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed.
S&F in repair ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
S&F in repair Edgepro range of slim-fit low profile downlights are engineered to deliver superior light output and uniformity utilising the latest edge-lit LED 6 watt decorative recess mounted Complete all as specified and directed
M & L in repair for Decorative walll mounting chamagne gold finish fixture with plastic body suitable for 9 watt B-22 complete all as specified and direccted.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly into the ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including testing on completion complete all as specified and direccted.
L G BUILDERS
n s kumar and sons
M/S Yamin
LAXMI GROUP
M/s M M BAHL
M/s Puja Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .