Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.5 L+₹1.2 L (4.03%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹31.8 L+₹2.5 L (8.47%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹32.6 L+₹3.2 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹33.1 L+₹3.7 L (12.7%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹47.3 L
EMD Value
₹94,600
Closing Date
17 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt - 10
Garrison Engineer South Delhi Cantt 110010
SPL REPAIR TO BLDG NO.P-32 (QUARTER GUARD AND KOTE), AT 10 JAK LI UNDER AGE B/R-I AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2022_MES_558985_1
GE/DS-83/2022-23
Open Tender
Civil Works
Item Rate
120 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹94,600
Yes
7 Dec 2022
20 Oct 2022
19 Nov 2022
20 Oct 2022
17 Nov 2022
3 Nov 2022
Amount
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and as directed.
Removal of entire existing water proofing treatment in any position including tarfelt plaster, lean concrete, gravels etc and removing the debirs out side MD land complete all as specified and as directed.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and as directed.
M&L 50 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof, padding to maintain the uniform slope complete all as specified and as directed.
M&L for rendering 15 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra complete all as specified and as directed. (Water proofing compound shall be measured and paid seperately).
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:-
(a) Applying oil bound bituminous primer at the rate of 0.30 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated.
(b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35).
(c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, (weight not less than 160 gm/Sqm) with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface.
(d) Applying two coats of aluminium paint over APP membrane complete all as directed. Make of APP: "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE.
Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done of water proofing treatment shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangment (Whether full thickness removed or only a part there of) and removing from cantonment area or complete all as spcified and as directed
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and as directed.
Supply only water proofing compound. (ISI Marked.Siko or equivalent)
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for 15 mm thick rendering with Readymix plaster (as per manufacturer's instructions) on fair faces of brick work or concrete surfaces finished even and smooth surface without using extra cement on wall and ceiling of up to four storied bldg complete all as specified and as directed.
M&L for 10 mm thick rendering with Readymix plaster (as per manufacturer's instructions) on ceiling/concrete surfaces finished even and smooth surface without using extra cement on wall and ceiling of up to four storied bldg complete all as specified and as directed. Notes for Srl item No. 11 & 12 :- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech Readiplast/ACC Accoplast/Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE. 2. The readymix plaster shall be procured directly from the manufacturer or from their authorised dealer. 3 The contractor shall produce original purchase voucher of readymix plaster while claiming RAR/ Final Bill. 4. The Engr-in-Charge shall verify the genuineness of these purchase vouchers before endorcing.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding for four storey building complete all as specified and as directed.
Complete removal of existing treatment old surfaces , plastered or unplasterered and applying two coats of cement base paint,white or tinted, over a coat of primer on walls/fins/fascia/ceiling etc including necessary scaffolding etc complete all as specified and as directed.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete all as specified and as directed.
M&L for preparation by complete removal of existing treatment , wahsing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and as directed.
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for applying two coat of white wash on ceiling of old surfaces including preparation of ceiling surfaces complete all as specified and as directed.
M&L for preparing old decorated steel surfaces of any description not otherwise described over 10 cm width or girth & applying two coat of synthetic enamel paint of any colour complete all as specified and as directed.
M&L preparation of newly surfaces of steel of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of red oxide primer complete all as specified and as directed.
M&L preparation of new or previously untreated surfaces of wood of any description not otherwise described width or girth and applying two coats of synthetic enamel paint over & incl one coat of pink primer complete all as specified.
M&L preparation of old painted surfaces of wood of any description not otherwise described width or girth and applying two coats of synthetic enamel paint complete all as specified.
Taking down chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames)removing from store complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each removing from store complete all as specified and as directed.
S&F in repair mild steel work such as in door chowkhats, tie bars etc including embedding into concrete and making holes for screwing of nut, bolts, cutting top to shape as directed, drilling holes, notching for wire etc confirming Fe 410-0 or Fe 310-0 complete all as specified and as directed.
M&L for Cement concrete in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) TypeC-0, 1:3:6 using 12.50 mm graded agregate complete all as specified and as directed.
S&F 35mm thick plain framed 2nd cl hardwood panelled shutter (two panels ) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle with commercial veneering on both face, the size of rail and style as per IS 1003 (Part-1) kiln seasoned and chemically pressed, treated complete incl 15 to 20 mm tapering bedding on one face of second cl hardwood fitted to chowkhats complete all as specified.
S&F for 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples etc complete all as specified and as directed.
S&F mild steel, 300 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S&F factory made solid FRP door frame of size 90mm x 45 mm made out of FRP sheet , suplying and fixing as per direction Engr-in-Charge or complete all as specified and as directed.
S&F factory made solid panel FRP door shutter 30mm thick premoulded design made out of solid core, laminated 1.5 mm to 2mm thick GRP/FRP made of superior all seson, weather resistant polyyester get coat followed by laminating polyster resin of 450 gm glass mat termite all as per manufacturers specification and complete all as specified and as directed.
S&F 100mm size butt hinges stainless steel of AISI 304 complete all as specified and as directed.
S&F 300 mm long, stainless steel of AISI 304 grade, sliding door bolt with hasp, staple (bolt type) and fixing clipss of sheet, cast or extruded sections and fixing bolts and fixed etc complete all as specified and as directed.
S&F stainless steel of AISI 304 grade barrel tower bolt 200 mm long, extruded section, etc complete all as specified and as directed.
S&F stainless steel of AISI 304 grade handle of size 200mm size long etc. complete all as specified and as directed.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand blasting scrubbing down conrete sufrace with wire brushes cleaning with water allowed to dry and applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of approved epoxy adhesive on complete exposed surfaces of concrete to be gunited all as specified and applying two layess of guniting over steel welded mesh 2mm dia of wire and aperture 75mm,total thickness of gunite n.exc 25mm thick (average thirteen) auth cement mortar 1: 2 using OPC 53 grade cement mixed with polycrete admixture @ 2% by weight of cement or as per manufacturers instructions and finally applying cement plaster over gunite surface of required thickness to give even uniform and smooth finish conforming to proper gerometrics in cement mortar (1:3) to match with the existing surface as in sides and soffits etc of slabs, chajjas, fins, facias, parapets, columns and beams etc complete including necessary scaffolding, shuttering, necessary chases to brick work or RCC members at any height upto 4 storey bldgs complete all as specified and as directed. Note : Steel welded mesh is to be tightening /welding with the existing re-inforcement. The cost of welded mesh is deemed to be included in the unit rate quoted.
S&F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
M&L for machine cut kota stone slab flooring, and (one Pieces) as in steps (Treads), 20-25mm thick over and including cement screed bed 20mm thick with CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
All as per Srl item No.39 above but of riser of step, dado skirting etc. laid over 15 mm thick rendering in CM 1:4 as in backing
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Glazed Ceramic coloured tiles in vertical surface 450X350X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick backing coat of cement mortar (1:4), complete all as specified and as directed.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site complete all as specified and as directed.
M&L 25mm th PCC 1:2:4 type B-1 using 20mm graded aggregate as in flooring, finished rough and even complete all as specified and as directed.
M&L coloured/light shade vitrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
All as per item No.46 above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick rendering in CM 1:4 on stone masonry surfaces.
M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished fair and even without using extra cement, complete all as specified and as directed.
S&F in repair Vitreous China bowl Urinal,flt back size of 465x355x265mm white,complete including providing and fixing plugs,bedding urinal gainst wall in cement morter 1:2,securing urinal to plugs with and including 60mm long screws,pointing around urinal back in cement ,fixing utomatic flushing cistern with brackets flush pipe, discharge pipe complete all as specified and as directed..
S&F in repairs vitreous china wash hand basin flat back size 550x400 mm size white excluding taps waste chain and plug and porcelain stopper but including brackets and 32 mm dia waste fittings brass chromium plated with long screwed shanks and fly nuts, 32MM X 600 MM long PVC waste pipe complete flange end bedded in red lead cement and other end fixed complete all as specified and as directed. Note - WHB will be supported on angle iron of size 50x50x5mm duly painted with two coats of synthetic enamel paint for securing WHB.
S&F in repairs low level flushing cistern of 10 ltrs capacity PVC valveless, syphonic action type, white with inlet ball valve float and handle complete all as specified and as directed. Make: Shakti/Prayag or equivalent
S&F PVC waste pipe 32/40 mm bore, 65 cm long PVC waste pipe suitable for WHB / Sink complete all as specified and as directed.
S&F in repair 15 mm dia brass chromium plated angle valve (fancy type), screwed at ends including necessary extention piece and fixed complete all as specified and as directed.
S&F in repairs bib tap, brass chromium plated fancy type, long body screwed down, screwed for iron pipe 15 mm bore complete all as specified and as directed.
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and as directed.
S&F 20 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and as directed.
S&F in repairs Cast iron floor trap with grating including jointing to waste pipe in run lead, dia of outlet 75 mm in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F in repair for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, of 110 mm dia complete all as specified and as directed.
S&F for PVC (SWR) bends any radius 110mm dia bore complete all as specified and as directed.
S&F in repairs PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe, complete all as specified and as directed.
S&F in repairs Chromium plated soap dish with screw complete all as specified and as directed.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S&F in repair Conceeled stop cock,15 mm bore, chromium plated, with long shank and cup, fancy type, complete all as specified and as directed. Make: Shakti/Prayag or equivalent
S&F, MS drapery curtain rods, stainless steel 30mm dia of approved quility with decorative wooden finish and two number brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod including 8 nos(min) match up rings etc complete all as specified and as directed.
S&F in repairs brass chromium plated shower rose of size 125 mm with arms including fixing to steel pipe complete all as specified and as directed.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in sub base complete all as specified and as directed.
M&L Machine pressed pre cast concrete inter locking paver block 60mm thick M-35 grade with grey cement and pigment & glossy finished any shape colour, size complete all as specified and as directed.
M&L for sand cushion under layer of floor complete all as specified and as directed.
M&L for removing excavated soils exc. 500m and and n. ecx 500 mtr depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Taking down carefully old U/S Aluminium point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and as directed.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable suitable concealed PVC/MS conduit and including replacment of unsv pressed steel terminal boxes of required size and factory painted with stove enameled black paint with top cover 3mm thick plastic/laminated sheet of required colour with screwed and cup washer with all accessories including 1.5 Sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for the following:- Note :- 1. The Rate is inclusive cutting/chasing and making good distrubed surface with CM 1:3 and same surface finishes with the adjoining surface of distribed area with ODB/colour wash/white wash complete all as specified and as directed. 2. At roof slab where there is burnt/blockage in the existing conduit wiring will be done through PVC conduit and rate are inclusive in above quoted item.
All as per Srl item No.73 above but One light /fan/Bell point/security light controlled by one way switch complete all as specified and as directed.
All as per Srl item No. 73 above but One 3 pin socket outlet 5 Amps on independent board complete all as specified and as directed.
All as per Srl item No. 73 above but One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed.
All as per Srl item No. 73 above but One 3 pin socket outlet, 15 Amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point all as specified and directed by Engr-in-Charge.
S&F switch piano flush type 5/6 Amp complete all as specified and as directed.
S&F socket outlet 5 pin 5/6 Amp two in one complete all as specified and as directed.
S&F switch piano flush type 15 Amp complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 pin 15/5 Amp complete all as specified and as directed.
S&F in replacement of Wall mounted LED Integrated Batten T5 20 Watt - 4Ft White, indoor decorative PVC extruded T5 LED battern-Integrated complete all as speficied and directed by Engr-in-Charge.
S&F battan holder PVC insulated body complete all as specified and as directed.
S&F LED lamp 12 Watt with LED Bulb complete all as specified and as directed.
S&F fan regulator electronic, socket type, Switch type, suitable for ceiling fan 1200/1400 mm sweep complete all as specified and as directed.
S&F BLDC (Brush Less Direct Current) ceiling fan of 1200mm sweep, not less than 350 RPM and Air Delivery 215 CFM, Voltage 220V, high air flow with silence operation, having full copper motor & ribbed 3 Nos A/M blades. The BLDC motor fan shall have 100% rust-free blade. the fan shall have BEE 5 star rating and compliant with IS-374 and making necessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan including taking down of old unsv ceiling fan complete all as specified and as directed. Note :- Old unsv ceiling fan deposited to MES store yard.
M&L for opening of hole through out the wall as suitable for exhaust fan of size 250mm sweep and fixing of nut-bolts with 4" anchor fastner of suitable size and making food the disturbed surface and all as per site requirement. Note : The rates are inclusive in respect of under this item as above hole opening civil work with MS faster bolt of 8mm dia and 100mm (minimum) long for fixing of exhaust fan and MS fastner clamps strip 38 mm wide and 5mm thick (min) to hold exhaust fan.
Supply and fixing of metal body exhaust fan 250 mm sweep, 230 Volts with louver and copper wound including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with complete all as specified and directed all as specified and directed by Engr-in-Charge.
S&F of ceiling rose surfaces bakelite minimum size 65x50mm with two/ three terminals complete all as specified and as directed.
S&F in replacement of sheet metal enclouser V TPN 4 way for MCCB 125A, 4P incomer, double door DB, IP-54, bus bar, neutral link, earth bar and din rail complete all as specified and as directed.
S&F in replacement of MCCB 125 Amps, 4 Pole, 415 Volt with 25 kA including elecrical connection incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and as directed.
S&F in replacement of MCB DB SPN 4 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 100 Amps rated bus bar complete all as specified and as directed.
S&F in replacement of MCB DB SPN 8 Way with metal double door, (IP43 Protection) flush mounting epoxy powder control having 100 Amps rated bus bar complete all as specified and as directed.
S&F in replacement MCB SPN 'C' curve 40 to 63 Amps 240 Volts , 10 KA complete all as specified and as directed.
S&F in replacement MCB SP 'C' curve 06 to 32 Amps 240 Volts complete all as specified and as directed.
S&F in replacement MCB SP 'C' curve 40 Amps 240 Volts complete all as specified and as directed.
S&F LED Building security light fitting 40 Watts including taking down of old unsv existing building security light fitting any type, from existing bracket with and including replacement of unsv bolts, nuts and washers etc complete all as specified and as directed.
S&F in replacement GI pipe's bracket suitable for fixing of bldg security LED light fitting of 40Watts including grouting and fixing the same on wall for installation of light fitting with necessary clamps, nut, bolts & washer and painting by synthetic enameled paint in white/grey colour over one coat of red oxide primer until unless smoothness of bracket complete all as specified and as directed. Note :- GI pipe should be 25 mm bore dia with medium grade and the same to be moulded in 45 degree angle at the 1 Mtr height to fix the building security light fitting.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing all as specified and directed by Engr-in-Charge.
Taking down unserviceable sub main wiring twin core any size complete and making good the disturbed surface complete all as specified and as directed.
M&L for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn PVC conceiled conduit of size 25mm dia with complete all as specified and as directed. Notes :- (i) Phase should be Red/Yellow/Blue. Neutral wire should be black colour and Earthing wire should be of green colour. Three runs of cable (phase, neutral and earth) will be measured and paid as one unit length and making good the specified and directed by Engineer-in-Charge. (ii) The rates are inclusive of cutting / chasing and making good to disturbed surface with CM 1: 3 and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash /white wash complete all as specified and as directed.
M&L for sub main wiring using single run PVC FRLS grade insulated unsheathed, multistrand copper conductor cable 3 runs of 10 Sqmm for Phase and neutral and 1 run of 10 sqmm for earth wire drawn through suitable size of PVC concealed conduit complete all as directed by Engr-in-Charge. Notes :- (i) Phase should be Red/Yellow/Blue. Neutral wire should be black colour and Earthing wire should be of green colour. Three runs of cable (phase, neutral and earth) will be measured and paid as one unit length and making good the specified and directed by Engineer-in-Charge. (ii) The rates are inclusive of Cutting / chasing and making good to disturbed surface with CM 1: 3 and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash /white wash complete all as specified and as directed.
Note : The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
ramveer Singh
M/S.M.S.Devi.Const.Co
Kunal Construction Co.
HANUMAN BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .