Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC 22 1755A KANNANKATTU TEMPLE ROAD EDAKOCHI KOCHI 682010 ERNAKULAM KERALA 682010 | ERNAKULAM | KERALA | 682010 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.7 L+₹85,278 (3.30%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹28.0 L+₹2.1 L (8.31%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹28.2 L+₹2.3 L (9.08%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹28.8 L+₹3.0 L (11.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 May 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
REPAIR AND MAINT OF LT NETWORK SYSTEM APFC PANEL MCCBS CABLES AND CONNECTED WORKS AT ARTRAC LINE STN HQ AREA MUSEUM PO ROAD GATE NO 4 MH GOLF VIEW 4 MAHAR AUDITORIUM AND HQ INF SCHOOL AREA UNDER GE MIS MHOW
2024_MES_651826_1
8657/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
210 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹60,000
Yes
5 Jul 2024
1 May 2024
31 May 2024
1 May 2024
29 May 2024
15 May 2024
Amount
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cable, pole foundation etc complete all as specified.
All as per item No 01 above depth exceeding 1.5m but not exceeding 3.0m
M&L for Plain cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified
M&L for plain cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coping of size 300x300 mm ,chamfered on edges including necessary formwork complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. Note :- Thickness shall be measured after punning
M&L for old size sub class ‘B’ bricks, laid in trenches as a cable covers complete.
S&F steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
S&F steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete.
M&L for dismantaling of old cracked /unserviceable PCC poles /MS pole struts any type and size including shifting from site to contractor store complete all as specified and as directed
M&L for Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately under relevant item. Make : India Tube and Co, Kalinga tubes, The National tubing company, India Electric Poles Mfg Co
M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. and taking out the required length of cable from existing loop and remove/ cut the defective cable,replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and make electic connection as functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge.
Note:- (A) The quoted rate shall be inclusive of the following: (i) Necessary earth work excavation as required for finding/attemding faullt /in any type of soil, returning filling and removing extra soil. (ii) Existing bricks, sand,GI protection pipe etc. shall be removed carefully and stacked neatly near site and re- laid the same in position after attending fault/defect. (iii) Distrubed surface of road, floor etc. shall be make good to match with existing surface. (iv) Required numbers of electrician and helper shall be deployed for attending complaints regulerly on daily basis and contractor shall collect the complaints details from complaint cell of AGE E/M No.1 and same shall be rectified/ attanded within an hour and report shall be submitted to Engineer-in-charge or their authorised representative. (B) Please note that payment shall be made to contractor one time only for this items. if any fault/ default occured again on the same location/ DB/junction box/panel during currency of contract, the same shall be rectified by the contractor without any extra cost to Govt. in terms of condition 46 of IAFW 2249 of Genral condition of contracts. (C) Additional bricks,sand,GI pipe etc. as required for cable protection and cushioning shall be measured and paid separetely under relevant item.
M&L for dismantling / disconnecting / removing the faulty / burnt out overhead conductor of any type / size from insulator of HT / LT pole any type by making proper shutdown from department and removing of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection as required, remove the burnt / damage conductor / earth wire and making necessary joint with new ACSR conductor of suitable size as per existing as directed, restretching all loose spans of ACSR conductors, earth wire etc. with insulator and providing binding wire of existing size to tigheting and making LT/HT cable in existing position and make electric connection as functionable in all respects including testing on completion allas specified and directed by Engineer in charge.
NOTE: (a) The quoted rate shall be inclusive of the following:- (i) Tools and plants such as ladder,rope, cutter, axes, knife etc. as required for cutting and removing tree/branches if any fall on OH line. (ii) Insulator,binding wire etc. as required in addition to existing shall be provided by the contractor. (iii) Required numbers of Elecrician and helper shall be deployed for attending complaint regularly on daily basis and contractor shall collect the complaint details from complaint cell of AGE E/M No. 1 (b) Additional ACSR conductor and earth wire shall be measured and paid separetely under relevant items.
S&F in replacement of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply only LED driver of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specified Make:- Philips, Bajaj, Havells
S&F in repair of all-in-one integrated solar street light 24/25 W compact,Asthetic, Eco friendly & Modern integrated solar streetlight in extruded aluminum construction with high-efficiency monocrystalline silicon photo voltaic panel, high efficacy SMD LED 6500 K having secondary lens optics for street lighting distribution, high-performance lithium battery, MPPT charge controller and intelligent control module/sensor with higher reliability, long service life, suitable for easy and quick installation. MAKE:- WIPRO /BAJAJ / Halonix/ Havells.
Taking down old unserviceable capacitor of any capacity and replace with new Duco Power XD capacitor, with stand Harmonic overloads upto 4 Amp Max current, low losses 0.2 watt / KVAR, three-phase, temperature range (-) 25 degree centigrade to 70 degree centigrade of the following ratings :-
M&L for trimming /pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of Engineer-in- charge complete including removing the tree branches from site complete all as specified and directed . NOTE : (a) A written shut down shall be obtained from concerned JE / AGE E/M before carrying out the trimming work in hand by contractor (b) Approximate span between poles shall be 30 to 50m. (c) T & P such as ladder , rope, cutter , axes and other related material shall be provided by the contractor.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
Supply and Laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable UG cable for the following sizes. Note: Earth work, excavation, sand cusioning, bricks for protection, GI pipe etc shall be measured and paid separately under relevant items of this schedule .
10 sqmm 4.0 core
16 sqmm 4.0 core
25 sqmm 3.5 core
35 sqmm 3.5 core
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
S&F in repairs Aluminium lugs of size 16 sqmm
S&F in repairs Aluminium lugs of size 25 sqmm
S&F in repairs Aluminium lugs of size 35 sqmm
S&F in repairs Aluminium lugs of size 50 sqmm
S&F in repairs Aluminium lugs of size 70 sqmm
S&F in repairs Aluminium lugs of size 95 sqmm
S&F in repairs Aluminium lugs of size 120 sqmm
S&F in repairs Aluminium lugs of size 185 sqmm
S&F in repairs Aluminium lugs of size 240 sqmm
S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
S&F in replacement of MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 160 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 200 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 3 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA
S&F in replacement of MCCB 4 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA
S&F in replacement of pin type porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade.
S&F in replacement of shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 75 mm and max dia 90 mm suitable for working pressure 1100 volts grade.
S&F in replacement of disc insulator, porcelain, vitreous 145 mm high and 255,, dia ball and socket type, white, brown or green suitable for single disc asst for tension with tension clamps for conductors, working pressure 11000 volts grade.
Fixing only in repairs of aluminium conductor steel reinforced, any sizes for replacement of broken over head line conductor of any type and length as required at site including removing of foreign objects/ obstacle, if any on the over head line, all as specified and directed
S&F in repairs aluminium conductor steel reinforced, any sizes as required at site including replacements of line jumper or repairs of any brocken OH Line completr all as specified and directed
M&L for Restringing of loose over head conductor / GI earth wire of any size and type after untyeing binding wire from insulators / cross arms to achieve permissible sag limit of over head line including new binding wire of proper size and pruning of tree branches of concerned spans and jointing of jumpers properly complete all as specified and directed at site. Note:- (i) Each span shall consist of 3 phase , 4-wire over head line. (ii) The distance of one span between poles shall be 30 to 50 metre .
S&F in repalcement of straight through joint ( Epoxy joint) for following size PVC insulated and sheathed aluminium conductor cable complete for following sizes :-
3.5 core 50 sq mm
3.5 core 70 sq mm
3.5 core 95 sq mm
3.5 core 120 sqmm to 150 sqmm
3.5 core 185 sqmm
M&L for repairing damaged /corroded portion of existing LT panel board of any size by providing and welding MS sheet of existing thickness, replacing hinges, aldrop bolt as required and made for proper locking system and painting internal and external surface of LT panel with one coat of synthetic enamel paint of approved colour all as specified & directed by Engineer-in-charge.
S&F in repairs AC three phase keypad based, BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) with bluetooth compatibility and mobile application complete all as specified. Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs AC single phase keypad based,BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) With bluetooth compatibility and mobile application complete all as specified. Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs AC Single phase two wire static watt hour meter (Electronic KWH Energy meter) of rating 5-30 A, class 1.0,240 V,50 Hz,LCD Display complete all as specified. Make:- HPL Cat part No SPPB1310000000OC00 or other equivalent in SECURE / L&T Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs AC Three- phase, static watt hour meter (Electronic KWH Energy meter) of rating 10-60 A, class 1.0,240 V (L-N) ,50 Hz, LCD Display complete all as specified. Make:- HPL or equivalent in SECURE / L&T Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs three phase contactor 5kW of load capacity 20-25 Amps, incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified . Make:- ABB/L&T/Schneider
S&F in replacement single phase contactor 5kW of load capacity 40 Amps, Incoming-Outgoing MCB rating 32-40 Amps & Circuit wiring minimum 10 Sqmm complete all as specified . Make:- ABB/L&T/Schneider
S&F in repairs MCB TPN, 415V, 40 Amps, 'B' series
S&F in repairs MCB TPN, 415V, 63 Amps, 'B' series
S&F in repairs MCB SPN, 32 Amps, 240V
S&F in repairs MCB SP 6 to 32 Amps 230 Volt
M&L for preparing surface of street light ,steel tubular swaged/ swan neck pole of any type and painting with two coats of aluminium paint over a coat primer from top to bottomincluding painting to cross arms /FI clamps/street light brackets of any type including making painting alternative bay with blak and yellow strip with synthethic enemelled paint up to 1.5 meter height from ground level and writing of pole numbers with black paint on poles complete all as specified
M&L for preparation of old painted surface of LT PCC street light pole up to 1.50 m height from top of PCC foundation block and painting the pole in alternative strips with black and white Radiant paint (each strip 30cm high) and including writing pole nos. and applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and as directrd by Engineer-in-charge.
Supply, fabrication, installation, testing and commissioning of out door type LT panel board of suitable size mounted on PCC foundation, made out of MS sheet 3.15 mm thick ,suitable size angle iron frame factory assembled and factory fabricated duly spray painted with two coats of grey synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation of the surface and required civil work and wiring with copper cable of suitable size, indication lamp LED type for each phase, Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 400 Amp rating - 01 No. for neutral, inbuilt industrial type locking arrangments, front openable, necessary arrangments for fixing with suitable, clamps, nuts, bolts washers etc, provinding danger notice board including testing and commissioning complete all as specified and directed
S&F cable path indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick and spot welding with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B1 using 12.5 mm graded granite stone aggregate including providing one coat of synthetic enameled black paint over a coat of red oxide primer including writing HT/LT cable with white paint complete all as specified and directed .
M&L for cutting the existing bituminous road of size n.exc 0.5m width for passing of UG Cable in road crossing and making good the disturbed surgace of road with plain cement concrete 1:2:4 type B1 complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
SAHYOG ELECTRIC
S.S. Engineers
Sameer Auto Engineers
ENVIRO TECH SERVICES
Mighty Steel Sales Crop
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .