| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 7 75 MOTI NAGAR WEST DELHI DELHI 110015 UDYAM DL 11 0011607 07AAKPG9965G1Z9 R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110015 | Admitted-Finance |
| 2 | Admitted-Finance 3279 1 RANJIT NAGAR NEW DELHI 110 008 | NEW DELHI | NEW DELHI | DELHI | 110008 | Admitted-Finance |
| 3 | Admitted-Finance 8 BALAJI ESTATE TOWER C 2ND FLOOR GURU RAVIDAS MARG KALKAJI NEW DELHI INDIA 110019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical B 69 SECTOR 65 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical G F OLD NO 10 A KH NO 952 133 BASEMENT A 5 100 FOOTA ROAD KABIR NAGAR EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
Closing Date
24 Mar 2022, 2:30 pmClosed
AO (W)
ME Unit
Installation of IOT and sensor operated climate controlled greenhouse as vertical farm at IARI New Delhi - 12.
2022_DARE_675375_1
30-27/21-22/ ME Unit
Open Tender
Civil Works
Works
30 days
IARI
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
3 Jun 2022
24 Feb 2022
25 Mar 2022
24 Feb 2022
24 Mar 2022
25 Feb 2022
Amount
Complete roof and side structure made of hollow GI section size 2 mm thickness. GI Pipe 65 NB
Complete roof and side structure made of hollow GI section size 2 mm thickness. GI Pipe 50 NB
Complete roof and side structure made of hollow GI section size 2 mm thickness. GI Pipe 40 NB
Complete roof and side structure made of hollow GI section size 2 mm thickness. GI Pipe 32 NB
Complete roof and side structure made of hollow GI section size 2 mm thickness. GI Pipe 25 NB
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (A)Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (B)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (C)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (D)Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. All kinds of soil
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (E)Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (F)12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (G)12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (H)Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Construction: IS-2645 Civil construction standard. CC foundation(1:3:6) Digging:2’x1.6’’ Base:-PCC 2’’ thick wide:- 13’’ First base line:13’’ second base line: 9’’ Height of wall : 1’-6” below GL and 2’ above GL frame base block: 2’x9’’x9’’ plastering: 1:4 Flooring: Concrete flooring for total area. Weed mat: Covering of floor under benched with weed mat, as approved by the engineer-in-charge. (I)Supply and laying of weed mat UV stabilized GSM 140
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (A)Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (B)Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (C) Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (D) 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (E) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (F) 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (G) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (H) Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (I) Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Hot finished welded type tubes
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (J) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (K) Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (L) Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Separate room for housing fertigation, chiller, filtration and PLC controller (24 sqm) 4’’ high concrete bases for mounting fertigation related equipment. (M) Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new work
Structure roof, side front & back truss will be covered with U. V. Stabilized polyfilm200 micron clear anti drip multilayered,
Aluminum locking profile with pre coated Zig Zag spring for fixing of poly film (Roof top &Side). Aluminum locking profile
Aluminum locking profile with pre coated Zig Zag spring for fixing of poly film (Roof top &Side). pre coated Zig Zag spring
Aluminum (Thermal) shade net inside the Green House: Aluminate thermal net 50% inside the poly house fix with motorize automated system (1000 square meter) Aluminate ( Thermal ) shade net inside the Green house with fixture
Aluminum (Thermal) shade net inside the Green House: Aluminate thermal net 50% inside the poly house fix with motorize automated system (1000 square meter) motorize automated system
Technical specifications cellulose pad: Evaporative cellulose pads are made from a specially formulated cellulose paper impregnated with special compounds to prevent rot, early moss formation and ensure a long service life.Size: 36000x1500x150mm (HXWXT) Paper ambient condition: 25◦C-45◦C nominal efficiency:88% estimated cooling load: 101,520BTUs/hrs Water flow:9.56LPM Temperature: 10to 12◦C below. Ambient @45%RH Self-cleaning feature: High saturation efficiency
54’’ fans with auto opening system with auto floating dampers SS/GI and SS Blades with 415 V,50HZ,1.5HP,1/3 ph motor with electrical cables, safety grills necessary fittings etc. complete.
20-22inch high speed fans,220V,single phase
PVC water distribution system of (20-25mm dia pipe) for cooling pad with 1" screen filter.
LED light (9W) 1 no will be provided in buffer room compartment. Electrical device:- High quality ISI approved fittings with copper multi strand twisted FR grade cable and rigid stds of safety with proper M.C.B. with appropriate electrical points of 5 Amp & 15 Amps. Copper cable, MCB, Switch & socket , Fluorescent tube ,conduit-ISI approved quality.(Wire of brand like KEI, Finolex, Havells of approved by engineer-in-charge.)
Auto control panel: Micfoprocessor photosynthesis contro; panel: a) Microclimate tempresature controller. B) Main switch rotoy c) individual indicator Temperature controller: Real time microprocessor based user programmable PID controller. PLC based controller for temprerature, humanity & light with SMS a data logging facility: Electrical panel inlcuding distribution panel. a)color HMI-touch screen – make delta b) temperature+ RH transmitter+ plitz timer c) sensor probe platinum -100A d) software –PLC +HMI software e) Manual switch over option for manual control f) SMS alert system for individual chamber g) Data logging facility for individual chamber h) Online monitoring and control to make changes over app. Provision for incorporating climatic and fertigation related sensors in future, separate data logger for measuring power consumption.
Provision of climatic sensors mainly temperature , humidity,CO2and light sensors and fertigation related sensors like EC ,PH , TDS,DO,BOD,IOT based system with HMI panel for automation.
Both sides long roll-up plastic curtains, openable to 3m, on two width sides with manual gearsystem complete in all respect. 40 mesh nylon insect proof net (UVstablised) white colored to be fixed inside the curtain on sides leaving 1 m from the ground level. Nylon insect Net 40 Mesh on both with fixture.
Both sides long roll-up plastic curtains, openable to 3m, on two width sides with manual gearsystem complete in all respect. 40 mesh nylon insect proof net (UVstablised) white colored to be fixed inside the curtain on sides leaving 1 m from the ground level. Rolling Pipe 20mm NB
Both sides long roll-up plastic curtains, openable to 3m, on two width sides with manual gearsystem complete in all respect. 40 mesh nylon insect proof net (UVstablised) white colored to be fixed inside the curtain on sides leaving 1 m from the ground level. PVC Gripper
It consists of overhead, four way anti-leak foggers with 22-28 lph discharge which gives very fine drop lest size at spacing 2.5m X 2.5m, PVC pipe of 6 kg/cm2 pressure rating of various sizes, Air Release valve, PVC ball valves Flush valves for flushing of sub-man, plastic Disc Filter, fitting and Accessories.
Sprinker unit heavy duty butterfly nozzles sprinkers, filter, pipes, etc. for roof top cooling installed at above polyhouse Distance between sprinkers -2m Specification & make: 1. 3 phase pump make ISI 2. pipes size is in between 16 to 32 mm, as per requirement 3.nozzles types- fogger ultra fine 15 micron 4.nozzles water discharge 27 litre/hour. 5.all pipes are ISI mark 6.screen filter with appropriate capacity 7.end lateral will be providing for flushing
5mx2.5mx4m high insulated space within the polyhouse Multilevel 5 levels NFT grow racks MS steel racks with powder coated paint finish 5 level of growing witheach level 2 ft high LED grow lights suitable for growing leafy greens,herbs,and edible flowers. grow light >20mol/m2/day 1 TONN AIR conditioning unit connected with thermostat & PLC to keep grow room temperature below 28◦C 100 litre/day dehumidification capacity to keep grow room humidity level between 30% rh -60% RH .On/off operation automated via RH sensor & PLC PLC for lightning and irrigation control
Growing System .should provide vertical A-Frame growing racks(5 levels) based on Nutrient Film Technique that adheres to the following: a)UV stabilized whitecolour food grade material using calcium zinc stabilizer. b) minium plant spacing:5’’ c)the system shall be recirculating type d)A-FRAME dimension 10 ft longx6ft highx5ft wide e)vertical A-Frame growing racks should cover 30% area f)All necessary pumps, tanks and other accessories required for operation shall be ISI marked and of reputed make.
Growing System . should provide vertical growing towers as per the following specs: a. grow towers made of food grade material b.grow towers system to cover 30% area c.grow towers to be self –irrigation type with 40 plant capacity per tower d.grow towers to be of octagon shape with approx dimensions:6ft highx2ft base diameter.
Growing System .vertical overlapping multilayer NFT system with grow light Galvanized iron metal frame-3mm thickness NFT UPVC channel –lead free-3mm thickness, size 100x60mm grow light over each NFT channel-200 to 300 PAR at 12 inches -15-18 watt per 4 ft length. plant capacity-5000.
Growing System .NFT vertical A’ frame system openable top NFT UPVC channel –lead free-openable top- 2mm thickness size 100x60mm. Galvized iron metal a frame -3mm thickness Plant capacity 1250.
Growing System .Dutch bucket system: UPVC Dutch bucket-1 ltr capacity – with lid and net pot 16mm lateral pipe drip line 2LPH pressure controlled dripper base stand for dutch bucket costed wire tressling complete system with clips and thread plant capacity -160
Fertilization and auto dosing system with automation: irrigation control shall be mixing tank based with the following features Controller:PLC based user operating system touch screen based operator window 4 fertilizer dosing channels with capacity of 400 LPH 1 Acid dosing channel with capacity of 100 LPH EC CONTROL MODULE & Ph control module multistage system pump – stainless steel -316 grade @ 2.2 KW Field control: time interval (off/on) can be done sampling (EC&PH)Schedules field valves control fertigation dosing control: solenoid valves-4 nos(A,B,C&acid) flow monitoring-flow indicators to be provided for each dosing channel all necessary pressure monitoring gauges, pressure relief valves, non return valves, internal control valves, and pressure piping. field valves shall be controlled automatically on time base with single or multiple at one time as a group by pass mode operation.
Pumping system: 4 mono block pumps of 2 hp(for NFT) (2 running 2 stand by) all pumps BIS/ISO certified One (1) mono block pump 1.5hp for cooling pand& one (1) mono block pump 3hp for fogger 3phse mono pump with automation All pump BIS/ISO certified. (A) Mono block pumps of 2 hp with all fittings and accessories
Pumping system: 4 mono block pumps of 2 hp(for NFT) (2 running 2 stand by) all pumps BIS/ISO certified One (1) mono block pump 1.5hp for cooling pand& one (1) mono block pump 3hp for fogger 3phse mono pump with automation All pump BIS/ISO certified. (B) Mono block pumps of 1.5 hp with all fittings and accessories
Pumping system: 4 mono block pumps of 2 hp(for NFT) (2 running 2 stand by) all pumps BIS/ISO certified One (1) mono block pump 1.5hp for cooling pand& one (1) mono block pump 3hp for fogger 3phse mono pump with automation All pump BIS/ISO certified. (C) Mono block pumps of 3 hp with all fittings and accessories
Plumbing lines: UPVC pipe of (20-50mm dia) & length on pressure side. PVC pipe of (90-110mm dia) &length on non pressure side.
Valves and filters with automation ( BIS/ISO certified) 4 solenoid valves with electric timer system manual control valve on each grow lane (UPVC) disc filters of ½,1,2,&3 inch capacity. timer –automation timer for pumps , valves, filter etc
Tanks : Overhead tank: all overhead tanks for dosing solution. 5 tanks -1000 litres each 3 layer (nutrition) underground tank: 3 underground tanks(each 5000 ltr) 1 underground tank for Raw and rain water storage (5000 ltr) Rain water harvesting system: all gutters should be connected with hanging anchored PVC pipes. 3 inch dia to the covered RCC drain provided around the structure. the final outlet of drains should be connected to the underground water tank for rain water storage. (A) 1000 liters 3layer PVC tank
Tanks : Overhead tank: all overhead tanks for dosing solution. 5 tanks -1000 litres each 3 layer (nutrition) underground tank: 3 underground tanks(each 5000 ltr) 1 underground tank for Raw and rain water storage (5000 ltr) Rain water harvesting system: all gutters should be connected with hanging anchored PVC pipes. 3 inch dia to the covered RCC drain provided around the structure. the final outlet of drains should be connected to the underground water tank for rain water storage. (B) 5000 liters underground Cemented tank
Tanks : Overhead tank: all overhead tanks for dosing solution. 5 tanks -1000 litres each 3 layer (nutrition) underground tank: 3 underground tanks(each 5000 ltr) 1 underground tank for Raw and rain water storage (5000 ltr) Rain water harvesting system: all gutters should be connected with hanging anchored PVC pipes. 3 inch dia to the covered RCC drain provided around the structure. the final outlet of drains should be connected to the underground water tank for rain water storage. (C) Rain water harvesting system
RO water filtration: 1000 ltr/hr capacity water filtration system with all accessories as per BIS guidelines componenets: Raw water pump (1HP) SAND Filter, RO membrane micron filter (10 micron), UV filtertube (2 nos)
Chiller: 5 ton capacity to keep nutrient water temperature within a range of 12-20◦C for fresh as well as recirculated nutrient solution
Germination room: GI stand, UPVC germination tray -200 mtr(or as actual req.) for 25 day plants automatic water circulation/sprinkle system(including storage tank).
Desktop with coloured printer & scanner: INTEL 7 PROCESSOR. 16 GB RAM,2 TB HARD DISK, WINDOW 10 LICENSED , MS OFFICE LICENSE,21 INCH SCREEN , 1KVA UPS, including all accessories.
Laptop: INTEL 7 PROCESSOR. 16 GB RAM,2 TB HARD DISK, WINDOW 10 LICENSED , MS OFFICE LICENSE,display 15 INCH including all accessories.
INTERSTATE ENTERPRISES
SHEEL BIOTECH LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .