Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | ₹9.2 L | L1 | Accepted-AOC Tender accept on 0.999 persent below on tender value |
Tender Value
₹9.3 L
EMD Value
₹9,273
Closing Date
26 Dec 2025, 5:00 pmClosed
Chief Executive Officer
Z P Satara
Constructing Liquid Waste Management Project at Parle Tal Karad Dist Satara
2025_SATAR_1261890_1
ZPS/RWS/SLW/2025 -1st call
Open Tender
Solid Waste Management
Percentage
365 days
Parle
As Per B-1 Tender
4 documents required · 4 mandatory
₹1,000
₹9,273
17 Jul 2026
20 Dec 2025
29 Dec 2025
20 Dec 2025
26 Dec 2025
20 Dec 2025
Sub Work 1-NADEP COMPOST PIT-1Nos. Excavation for foundation pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Providing and layong in Cement Concrete M-15 of map/gmanice poartanega meal for foundation and beddung inchaling balling and water, form work, compaction, caning, exc complete
Providing second class Burnt Brick masonry with conventional 15 type brick mo cement mortar 1.6 in plinth as backing in composite masony including bailing out water manually, striking joints rakingout joints and watering etc. Complete
Providing rough cast cement plaster externally in two coat stoconcrete brick or stone masonry surfacesinall positions with base coat of 12 to 15mm thick in C.M.1:4 and rough cast treatment 12mm thick in proportion 1:11/2:3 including scaffolding and fourteen days curring complete
Sub Work 2-PLASTIC STORAGE SHED Excavation for foundation in hard murum including remove the excavited material upto distance of 50 merers beyond the building area und stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming watering including shoring and strutting etc. complete
Filing in plinth and floors/trenches with contractor's murum for bedding in 15 cm to 20 cm layers including watering and compaction etc. complexe. (Bd-A-11/263)
Providing and laving in situ Cement Concrete M-15 of trap/ granite/quartzite/ gneiss metal for foundation und bedding including bailing out water, formwork compaction curring etc.complete (Cesment 5.90 bags/ cum)
Providing second class Burnt Brick masonry with conventional 15 type brick mo cement mortar 1.6 in plinth as backing in composite masony including bailing out water manually, striking joints rakingout joints and watering etc. Complete
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:3 withoutneeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete
Providing and faced plaster externally in cement mortar using approved screeneds and, all positions including base coat of 15mm thick cement mortar 1:4 using water proofing compound at 1Kilogram per cement bag curing the same for not less than 2days and keeping the surface of the base coat rough to receie the sand faced treatment 6 to 8mm thick in cement mortar 1:4 finishing the sunface by taking out grains and curing for fourteen days scaffolding etc. complete
Providing and fixing corrugated galvanised iron sheets of 0.63 mm thick (24B W.G.) for roofing without wind tiles including fastening with galvanised iron screw and bolts, lead and bitumen washer as per drawing etc. complete (Weight of 5.5 Kilogram/sq.m.)
Providing fixing Mild Steel screen jali Jalı welded mesh 2
Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete B)25X25X3 MM MS ANGLE
Sab Wark 3-ROOT ZONE FOR CENTER S1 A) For Anaerobic Baffled Reactor for Center S1 Excavation for foundation/pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete
Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
Excavation for foundation/pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering. excluding backfilling, etc. complete.
Providing and laying in situ Cement Concrete M-15 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags/cum)
Providing and casting in situ C.C. of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, AC.C., Ambuja, Birla Gold, Manikgad, Rajashree, Slabs/Landings/Vertical Walls/Waist Slabs/Steps for Staircase etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) Slabs / Landings/Vertical Walls/Waist Slabs/Steps for Staircase RCC M-200
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations,slabs, beams, columns, canopies, staircases, newels. chajjas, lintels, pardies, copings, fins, arches, etc as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required.etc. complete (including cost of binding wire) (Tor Steel)
Providing second class Burnt Brick masonry with conventional/1.5.type bricks in cement mortar 1:6 infoundation sand plinth of inner walls/in plinth external walls including bailing out water manually, striking joints on unexposed faces,raking out joints ane xposed face sand watering etc. Complete.
Providing Internal cement plaster 20mm. Thick in Single coat a in cement mortar 1:3 without neeru finish, to concrete, brick surface. inall positions including scaffolding and curing etc.complete
Providing and supplying in standard lengths ISI mark ngid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per ISspecification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges,inspection charges, loading. unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solverit cement,etc. complete (selffit type to be jointed withcement solvent). Working Pressure 6 Kg. /Bq.cm 160 mm with Lowering & Laying
Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement. joints including cost of couplers, as per ISspecification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges,inspection charges, loading. unloading.conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material ie solvent cement.etc. complete (selffit type to be jointed with cement solvent) Working Pressure 6 Kg. /Sq.cm 110 mm with Lowering & Laying
Providing and fixing reinforced cement concrete cover of size 90cm x 45cm with frame over inspection chamber etc. complete Medium duty (140 Kilogram)
Valve Chamber with Precast RCC Covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportionPCC bedding, excluding excavation, B.B.masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge 1.2 x 1.2 М internal size and depth upto 1.2 M with precast R.C.C slab cover.
Providing fixing Mild Steel Cover four chambersA)25 X 25 X 11 WELDED MESH
Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete B)25X25X3 MM MB ANGLE
B) For Planted Gravel Filter Root Zone for Center S1 Excavation for foundation/pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering. preparing the bed for foundation and excluding backfilling, etc. complete
Excavation for foundation/pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete
Providing and laying in situ Cement Concrete M-15 of trap/ granite/quartzite/gneiss metal for foundation and bedding including bailing out water, formwork, compaction, curing, etc. complete. (Cement 5.90 bags/cum)
Providing second class Burnt Brick masonry with conventional/1S type bricks in cement mortar 1.6 infoundation sand plinth of inner walls/in plinth external walls including bailing out water manually, striking joints on unexposed faces.raking out joints one sposed face sand watering etc. Complete.
Providing internal cement plaster 20mm Thick in Single coat a in cement mortar 1:3 without neeru finish, to concrete, brick surface, mall positions including scaffolding and curing etc.complete
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mm thick in cement mortar 1:4
Providing, lowering, laying and placing in position, shrouding material for porous pipe gallery/slotted pipe gallery/trench gallery with all leads and lifts involved including transportation of materials to site of works, screening and washing of materials and placing in position with given section, etc. complete as directed by Engineer-in-charge A)40 MM Metal
B)12 to 20 MM Metal
C)6 to 12 MM Metal
DISAND
Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per ISspecification no. 4985/1988 excluding GST levied by GOI and GOM in all respect including transportation, freight charges, inspection charges, loading. unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement etc. complete (selffit type to be jointed with cement solvent). Working Pressure 6 Kg. /Sq.cm 160 mm with Lowering & Laying
Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per ISspecification no. 4985/1988 excluding GST levied by GOI and GOM in all respect,including transportation, freight charges, inspection charges, loading. unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains Including cost of jointing material i.e. solvent cement.etc. complete (selflit type to be jointed withcement solvent). Working Pressure 6 Kg. /5q.cm 110 mm with Lowering & Laying
Valve Chamber with Precast RCC Covers Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportionPCC bedding, excluding excavation, B.B.masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. 1.20 x 1.20 M internal size and depth upto 1.2 M with precast R.C.C slab cover.
Providing Plantation for Root Zone as per Direction of Engineer in Charge etc. complete.
Sub Work 3-LEACH PIT S2-2Νοs. Excavation fo
r foundation in hard murum including removing the excavated material upto distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming. watering including shoring and strutting etc. complete
Providing and laying in situ Cement Concrete M-15 of trap granite/quartzite/ greiss metal for foundation and bedding including bailing out water,formwork, compaction, curing, etc. complete (Cement 5.90 bags/ cum)
Providing and casting in situ CC of trap/granite/ quartzite/gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge (Excluding MS. or Tor reinforcement) Slabs/Landings/Vertical Walls/Waist Slabs/Steps for Staircase RCC M-200
Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations,slabs,beams,columns, canopies, sturcases, newels, chagas, lintels, pardies, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire) (Tot Steel)
Providing second class Burnt Brick masonry with conventiotal/I.S.type bricks in cement mortar 1:6 infoundation and plinth of inner walls/in plinth external walls including bailing out water manually, striking joints on unexposed faces,raking out joints one xposed face sand watering etc. Complete
Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per ISspecification no. 4985/1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed withcement solvent) Working Pressure 4 Kg./Sq.cm 160 mm with Lowering & Laying
Providing, lowering, laying and placing in position, shrouding material for porous pipe gallery/slotted pipe gallery/trench gallery with all leads and lifts involved including transportation of materials to site of works, screening and washing of materials and placing in position with given section, etc. complete as directed by Engineer-in-charge 12 to 20 MM Metal
Providing foang Mild Steel screen jaliA)0.25 X 0.25 X 11 WELDED MESH
Providing and fixing reinforced cement concrete cover of size 60cm x 45cm with frame over inspection chamber etc. complete Medium duty (100 Kilogram)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Nit.pdf
Tender Documents • 1.10 MB
B1.pdf
Other Document • 3.02 MB
BOQ_2174664.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .