Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹41.4 LAccepted-AOC NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹41.7 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹42.1 LRejected-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹43.1 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | FORTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
20 Oct 2023, 5:30 pmClosed
GE AF MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
WORK SERVICES FOR PROVN OF WATER CHANNEL DRAINAGE TO OMQS AT IAMOE AT IAM AND OTHER SANCTIONED WORKS AT IAM UNDER GE AF MARATHAHALLI BANGALORE
2023_MES_618602_1
8650/E8
Open Tender
Civil Works
Works
180 days
GE AF MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE AF MARATHAHALLI
₹88,000
Yes
14 Dec 2023
13 Sept 2023
25 Oct 2023
13 Sept 2023
20 Oct 2023
7 Oct 2023
Amount
S&F powder coated Aluminium section for door frame , windows, ventilators, with one or more rebates, including joining cleats for fixing necessary lugs complete frame work complete all as specified.
S&F powder coated Aluminium section for door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium shap beading screws etx complete all as specified
S&F powder coated Aluminium section for window and ventilator shutters, Sliding type without sash aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium shap beading screws,powder coated aluminium fittings such as peg stays 150 mm long ( 1 Nos) hinges type B-21 100 mm long (2 Nos) suitable handle 1 Nos complete all as specified and as directed.
S&F powder coated aluminium grill as per IS: 1868 of approved design / pattern with approved standard section and fixed with powder coated aluminium channel using stainless steel screws all as specified and directed.
S&F 18mm thick prelaminated particle board,exterior grade,prelaminated both sides with decorative choice lamination, fixed with stainless steel screws all as specified and directed.
Supply and fixing 5 mm thick sheet glass, ordinary quality fixed with PVC / neoprene gasket , angular glazing aluminium beads, rubber packing and glazing in squares n exc 0.5 sq m Each pane for sliding rack with sliding handle all as specified and as directed.
S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples all as specified and as directed.
S & F floor door spring for aluminium door complete all as specified and directed.
S&F of mortice lock vertical type brass 100mm 4 lever complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above GL) all as specified and directed.
M&L for Vitrified Ceramic Colour tiles 9 to 10 mm thick light shade(Square / Rectangular) polished , area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles over and including cement screed or bedding layer of cement mortar 15mm thick in 1:4 complete all as specified and as directed
All as per item No 11.00 above, but, as in skirting over backing coat of cement mortar 1:3 10mm thick complete all as specified and as directed.
S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls and ceilings complete with GI clamps all as specified and directed.(Building configeration - G+4)
S&F of PVC bends of 110 mm bore without access door complete all as specified and directed.
S&F of PVC bends of 110 mm bore with access door complete all as specified and directed.
S&F of PVC (SWR) junction (Single T) equal or unequal fixed to 110mm bore of pipes with access door all as specified and as directed.
M&L for machine cut kota stone slab 20-25 mm thick as in splash stone over 15mm thick cement screed base 1:4 all as specified and as directed.
M&L for Removing material or debris retrives from above demolition or cleaning to a distance exceed 1.5 Km and not exceeding 5.0 Km and depositing where directed complete all as specified and directed
Taking down chowkhats or frames with shutters exceeding 1.5 Sq.m and not exc. 4 Sq. m Each (without taking off shutters from the frames) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M & L for rendering 15mm thick in CM (1:4) on brick and concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for pre cast cement concrete block masonry with solid block exc 10 cm thk in width (with plain or interlocking joints as directed) complete, in walls and set in cement mortar 1:6 of PCC 1:3:6 (Type C1) all as specified and as directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm grade aggregate) as in subbase in flooring complete all as specified and as directed. .
M&L for 25mm thick cement concrete type B-1, 1:2:4 (20mm grade aggregate) as in levelling coarse in flooring finished even and fair under floor finishes complete all as specified and as directed..
S& F of ceiling with GI snap grid frame work of size 595 mm x 595 mm in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel section (galvanized @ 170 gsm / sqm and bootom exposed width prefinished with baked polyester paint) consisting of main 'T' runners with suitably spaced joints to get required length and of size 38x24x0.5 mm spaced at 1200 mm center to center to form a grid of 1200 x 600 mm and secondary cross 'T' of length 600 mm and size 24x25x0.5 mm to be interlocked at middle of the 1200 x 600 mm panel to grids of 600 mm x 600 mm and wall angle of size 25x25x0.5 mm and laying false ceiling designer tegular ceiling board of 12mm thick mineral finish with 84% light reflectance laid / inserted to GI frame work with screw / clips foe false ceiling using GI slotted cleats of size 35x35x1.6 mm fixed to ceiling with 6mm dia and 5 mm long metal dash fasteners, 4mm GI slotted clets of size 35x35x1.6 mm fixed to ceiling with 6 mm dia and 5 mm long metal dash fasteners, 4mm GI rods with galvanized steel levelling clips spaced at 1200 mm center along main 'T' section (False ceiling system shall be capable to bear distributed load height of minimum 15kg/sqm)Make :- Saint Gobain / Everest / Gypsum India / Armstrong
Dismantling of wall and ceiling boards (fibre pulp, insulation, etc) or insulation boards/ slabs/ blankets any thickness, including cover fillets complete all as specified and as directed.
M&L for Complete removal of walls including washing, rubbing down and stopping of distempered surfaces and applying two coat of oil bound distemper over a coat of 1 mm thickness putty over plastered/uneven surface to prepare the surface even and smooth complete all as specified & directed.
Materials and labour for preperation of new plastered surfaces of walls applying two coat of oil bound distemper over a coat of 1mm thickness putty over plastered/uneven surface to prepare the surface even and smooth complete all as specified & directed.
Excavating in post holes (or similar holes) in hard /dense soil, each not exceeding 0.5 cum, in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering and removing surplus soil,complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in foundation filling in post holes.complete all as specified and directed
Removing excavated material exc. 1.50 km but n. exc. 5 Km and depositing where directed.complete all as specified and directed
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240.complete all as specified and directed
S&F Rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde E-250) quality A,complete all as specified and directed
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde E-250) quality-'A', complete all as specified and directed
M&L for preparation of surfaces new steel & iron of any description, not otherwise described, over 10cm width or girth and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.complete all as specified and directed
S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws as specified.complete all as specified and directed
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as in roof covering in any curvature as specified.complete all as specified and directed
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete
M&L for anti termite treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for preparation of old decorated ceiling surfaces including brooming down or steel wire brushing, scarping down smoke soot, module, mass and applyng one coat of oil bound distemper on ceiling complete all as specified and as directed
Materials and labour for preperation of new plastered surfaces of walls applying two coat of plastic emulsion over a coat of primer over a coat of 1mm thickness putty over plastered/uneven surface to prepare the surface even and smooth complete all as specified & directed.
Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by Engr- In - Charge.
Taking down Split AC 1.5/2 Ton capacity ( Indoor and Out door Unit) with stabilizer by removing all electrical connections and indoor to out door unit gas pipes ,nut bolts from roof top of bldg before starting of civ work and shifting to store for safecustody. After completion of civ work, Refixing /installing Split AC 1.5/2 Ton with voltage stabilizer at the suitable place by connecting all electrical connections and copper piping with insulation (5/8th x 1/4th) with nut bolts as per site requirement, testing and commissioning , if any extra cable , gas pipes , gas filling require at the time of installation the quoted rate is deemed to be included , No nextra cost will be paid to contractor complete all as specified and directed By Engr- In - Charge.
M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc, including all cutting/chases etc in walls and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed by Engr -in -charge for the following :- (a) One light point /Fan point controlled by one switch.
All as per item No.44 above, but , One 5 Amps socket point on same board with other switches
All as per item No.44 above, but , One 5 Amps socket point on independent board.
All as per item No.44 above, but , wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board .
Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
S & F modular socket 06 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module complete all as specified & directed.
Supply & fixing in repair of ceiling rose surface three terminals in replacement of old u/s complete all as specified & directed.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
S&F in replacement single pole and neutrla enclosure with two pin and earth plug and socket including 1Nos MCB 20Amps capacity complete all as specified and directed by Engr-in-charge
S&F in repair lumiline LED tube light fitting Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environment, friendly, energy efficient 4Ft of 18/20 Watts and making all necessary connections in the existing fittings and refixing the same back to its position complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells)
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of 250 mm sweep complete all as specified and directed. (Make : Bajaj /CG/Philips/Havells
Supply and fixing wall fan of single phase 230/240V of size 400 mm sweep and grouting with nut , bolts & Fastenar on the wall and make good the disturbed surface and electric connection with 1.5 Sqmm three core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
S & F MCB SPN 32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F in repair MCB DB SPN 12Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Taking down carefully copper / aluminium sub main wiring including teak wood batten / conduit and making good the disturbed surface of walls as directed.
Taking down carefully main switches DB's/ MCB DB's and making good the disturbed surfaces of walls etc complete all as specified and directed.
Supply and fix stepped type electronic fan regulator 5 step speed control for fans all as specified and as directed
Supply and fixing 36W LED Fitting, 2 x 2 recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified.
Supply and fixing ceiling fans complete incl anti suicide rods with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fixing "S" Hooks for ceiling fans hanging of size 1200 mm sweep making hole on roof for fixing "S" hooks of 10mm dia MS and making good for damaged surfaces all as specified.
S & F MCB DB SPN 8 Way with 200 Amps rated busbar, Double door, 240 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
Supply and fixing of Endura Citylite Platinum, 35 W/40 W LED Street Light fittingpressure die cast aluminium housing, heat resistance toughened glass, IP-65/66 protection including with bracket made out of GI pipe 32 mm , with clamps and nut bolts complete all as specified and directed.
Supply & fixing GI earth wire 4.00 mm dia for interconnecting of earth electrodes all as specified.
Supply and fixing in repair of Earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead strip protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Taking down ceiling fan/ wall fan of any size, sealing cable end,dismantling blades and removing fan and blades to store and refixing at Manekshaw Hall as per existing site required and connecting up including provision of cable from ceiling rose or connector to wall fan complete all as specified and directed by Engr-in-Charge.
Taking down carefully by unscrewing from tube light fittings/ decorative light fittings etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) and refixing complete all as specified and directed by Engr-in-Charge.
Refixing of MCB SP / SPN and making good after civ works at Manekshaw Hall as per exisiting site reqd complete all as specified and directed.
Refixing of MCB TP / TPN of 63 Amps and making good after civ works at Manekshaw Hall as per exisiting site reqd complete all as specified and directed.
Refixing of DB TPN 4 Way and making good after civ works at Manekshaw Hall as per existing site reqd complete all as specified and directed.
Taking down socket 5/15 Amps and switch and refixing after civ works at Manekshaw Hall as per existing site reqd complete all as specified and directed.
S & F in repair LED fitting of 6 watts - round type recessed / surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 6W LED lamp complete all as specified. (Make: Bajaj /CG/Philips/Havells
Supply and install hi wall split units air conditioner indoor/outdoor of capacity 2.0 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. Note:The extra lenght of suitable size of AC gas copper pipe / cable for insulation of AC as per site requirement is deemed to be included in the quoted rate) Make:- Blue Star / Carrier / Voltas
Supply and install hi wall split units air conditioner indoor/outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. Note:The extra lenght of suitable size of AC gas copper pipe / cable for insulation of AC as per site requirement is deemed to be included in the quoted rate) Make:- Blue Star / Carrier / Voltas
Supply and install hi wall split units air conditioner indoor/outdoor of capacity 1.0 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. Note:The extra lenght of suitable size of AC gas copper pipe / cable for insulation of AC as per site requirement is deemed to be included in the quoted rate) Make:- Blue Star / Carrier / Voltas
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA
M & L for Submain wiring complete with two runs of 6 sqmm single core FRLS grade PVC insulated unsheathed cable 1100 volt grade multistranded copper conductor drawn through and includingh PVC conduit and accessories in surface of wall, roof etc with one run of PVC insulated copper conductor 6sqmm single core as earth continuity conductor connected with earth dolly and mains complete allas specified and directed. (Note :- 2 runs of 6 sqmm single cable and one run of 6 sqmm earth wire cable incl PVC conduit 20/25 mm dia shall be considered as one unit/1RM
M&L for mild steel stand duly painted suitable for fixing 3/2/1.5 TR AC out door unit fixing in wall / floor, including making bore required size for copper pipe & copper cable with sweating pipe required size and length upto ground level complete all as spcecified and directed.
Taking down ceiling fan any size, any make fixed / hanged in different location in Vayu Vihar, dismantling the fan complete cleaning and re-assembling the same including replacing Anti suidcide down rods, split pins flexible copper cable of size 23/.0078 twin core 70 cm long and re fixing the ceiling fan on the same location in original position testing and commissioning of fan for smooth running as per entire satisfaction as directed.
Supply and fix 10" Gold life Smart MS down rod (Anti suicide fan rod ) white colour ceiling fan of any size complete all as specified and directed. (Make - Gold life / Safehalo Products)
m/s raghavendra kulkarni
Shanthi Construction
Aavani BUILDERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .