Loading…
Loading…
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
7 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
GE Khadakwasla
GE Khadakwasla
REPAIR/MAINT OF STREET LIGHTS /SECURITY LIGHTS/HIGH MAST LIGHTS ALLIED WORKS ZONE A AT NDA KHADAKWASLA
2026_MES_772868_1
8064/E8
Open Tender
Civil Works
330 days
GE Khadakwasla
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE Khadakwasla
₹96,000
Yes
17 Jun 2026
17 Jun 2026
9 Jul 2026
17 Jun 2026
7 Jul 2026
1 Jul 2026
17 Jun 2026 - 1 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Repair / maintenance of street / security lights any type, flood lights, post top lanterns, gate light ,Garden light or any other external lights in its position fixed on pole /building structure or by taking down to ground, if required, testing all the components/parts, wiring etc, identifying and replacing the defective components like electronic driver, connection wires/ cable, MCB etc including refixing the fitting to its original position (if taken down), including repair / maint of street light control timer & junction box complete all as specified and directed .
Note:
(i) The rate against the above mentioned item is deemed for cost of labour and allied expenses only.
(ii) Cost of spares electronic driver, connection wire, MCB, timer contactor spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below.
(iii) The contractor's representative will report to concerned JE E/M at 0900hrs daily to collect the list of defective street light fittings and will submit the completion report on the same day before 21.30hrs to the JE E/M.(iv) The contractor has to rectify the defects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M. In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill. The contractor shall carry out repair / maint work simultaneously for different zones / pocket / areas like :- (a) Offrs residential area D1, D2, D3, E3 including main road from Bombay stadium to peacock bay, road to LVGH & Kondhana.(v) Vehicle mounted hydraulic ladder shall be provided on contractor's request which will be measured separately under Schedule 'C'.
(vi) The contractor shall maintain proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (viii The contractor shall maintain sufficient stock of spares / material required for repair / maint of street lights with the concerned JE E/M against the supply only items here-in-below. (ix) The details of street / security lights is enclosed as Appx A to Schedule A for general idea about the location and type of light fittings. | 1,100 | Each | - | - | Relaying / Rerouting of serviceable XLPE LT UG cable of following sizes including disconnection from LT Panel/Pole/FP etc and reconnection after re-laying work to LT Panel/Feeder Pillar /MDB according to existing system with suitable size of AL Lugs, nut-bolts & washers etc and fixed on any type of wall with suitable size of GI saddles etc complete of following sizes :- Note - Excavation / earthwork, cable protection covers & sand cushioning will be measured and paid separately under respective item of sch A/BOQ. 3.5 Core 400 Sqmm |
| 2 | Taking down the existing light fittings on multi mounting brackets from 16/21 mtrs highmast pole by taking on ground repairs/ replacing the defective parts like electronic drivers connection wires and refixing the same to its original position complete all as specified and as directed. Note:
(i) Cost of spares , electronic drivers,connection wires replaced against above mentioned item above mentioned item will be measured & paid for separately under respective items of Sch 'A' here-in-below. (ii) The defects / repair of the floodlight making them functional after handing over defective floodlights of highmast
(iii) Maintaining proper record of repair / maint in a binded register duly bringing out the details of spares replaced on each and every flood light and getting it authenticated. (iv) Safety of his men engaged for executing the work along with safety equipment and clothes for the men shall be maintained. | 10 | Each Job | - | - | Ditto all as per item No 1 above but 3.5 Core 300 Sqmm |
| 3 | Supply only following street light spares of branded make as mentioned in the list of make enclosed with Particular specifications for replacement :- Electronic driver suitable for 90watts LED security light fittings Make should be as per the Existing manufacturer complete all as specified and as directed. | 60 | Each | - | - | - |
| 4 | Supply only Electronic driver for 30/40/ 45 / 48 / 50/60 watts LED road way/Flood light/post top Make should be as per the Existing manufacturer complete all as specified and as directed. | 120 | Each | - | - | - |
| 5 | Supply only Electronic driver for 400/300 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. | 30 | Each | - | - | - |
| 6 | Supply only Electronic driver for 200 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. | 30 | Each | - | - | - |
| 7 | Supply only Electronic driver for 150 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. | 50 | Each | - | - | - |
| 8 | Supply only Electronic driver for 50/100 watts flood lights Make should be as per the Existing manufacturer complete all as specified and as directed. | 50 | Each | - | - | - |
| 9 | Supply only MCB SP 230 volts B curve 6 amps complete all as specified and as directed. | 50 | Each | - | - | - |
| 10 | Supply only MCB DP 230 volts C curve 6 amps complete all as specified and as directed. | 50 | Each | - | - | - |