Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹23.8 L
EMD Value
₹24,000
Closing Date
2 Nov 2023, 12:00 pmClosed
Superintending Engineer, EDC, Hapur
Superintending Engineer, EDC, Hapur
Feeder byfurcation of line, Plinth, Fencing in area of EDD-Garh
2023_PVVNL_845753_2
71(W)/EDCH/2023-24
Open Tender
Electrical Works
Lump-sum
Hapur
Enclosed
3 documents required · 3 mandatory
₹3,540
SE, EDC, Hapur
₹24,000
2 Nov 2023
26 Oct 2023
2 Nov 2023
26 Oct 2023
2 Nov 2023
26 Oct 2023
Amount
FOR FEEDER BYFURCATION OF LINE/REPLACMENT OF ABC/WIRE, PLINTH, FENCINGH IN CATEGARY-A. (14 NOS. WORKS) AND OTHER ASSOCIATED WORKS, IN ADDITIONAL BUSINESS PLAN, IN THE AREA OF EDD-GARHMUKTESHWER, UNDER EDC., HAPUR.
Carriage of line material (Like: Insulator, Disc, conductor etc.) from Electricity Store Center, Hapur to site of work with loading and unloading at both ends on Kachha Packka road.
Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road.
Carriage of ST Pole 11 mtrs. Long from Electricity store center, Hapur/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road.
Erection & Fixing of PCC Pole 8.5 mtr. long in 11 KV/LT line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Erection & Fixing of ST Pole 11 mtr. long in 11 KV /LT line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing F-Bracket made of M.S. Flat of size 50x6 mm, Cross Arm holding Clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Laying of ABC Cable (3x95+1x70+1x16) Sqmm., and completion of work properly as per RESPO/Norms, including providing of required material like clamps, nuts bolts etc.
Laying, Stringing and final sagging of ACSR Weasel Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Laying, Stringing and final sagging of ACSR Rabbit Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops. (including cost of stay set complete.)
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts.(including cost of earth Rod complete.)
Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast) Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials.
Providing & Fixing of Earth Clamps, including suitable nuts and bolts, as per RESPO/Norms.
Providing and Fixing of Dead End Clamps with Eyehook completion work properly as per RESPO Drawing/Norms.
Providing and Fixing of LT Insulating Piercing Clamps completion work properly as per RESPO Drawing/Norms.
Providing of stay wire 7/10 SWG for completion of proper work as per RESPO Norms.
Providing of G.I. wire 4 MM/ 8 SWG for completion of proper work as per RESPO Norms.
Providing & Fixing of holding Clamps, including suitable nuts and bolts, on existing pole as per RESPO/Norms.
Fabrication, erection and fixing of V-Type 11KV X-Arm angle 65x65x6mm as per RESPO Drawing/Norms, including cost of the same and by providing required clamps, nuts and bolts.
Erection & Fixing of Distribution Box 01 Phase on pole by provding 02 Nos. D/B Clamps & proper size nut & bolts., including cost of the same.
Erection & Fixing of 11KV Pin insulator on existing 11KV pole as per RESPO Drawing/Norms by providing required nuts and bolts.
Erection & Fixing of 11KV Disc insulator on existing 11KV pole as per RESPO Drawing/Norms by providing required nuts and bolts.
Repairing of existing T/F plinth suitable for 250/400/630KVA T/F (size of 2 x 2 x 1.5 mt.) and (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation including cost of Cement, Sand, Brick ballast and Ist class brick etc all material & labour.
Construction of T/F plinth suitable for 250/400/630KVA T/F (size of 2 x 2 x 1.5 mt.) and (size of 2 x 2 x 1.5 mt.) as per drawing, cc work in foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth & ramming the same, including cost of all material & labour.
Erection & Fixing of 11KV. Fuse set unit complete on ST/PCC Pole by providing all required materials, including cost of 11KV Fuse set.
Providing fixing and fabrication of fencing (MS 5mp 5x6mm fencing, 6 feet hight including civil welt 2x4x3) around the T/F plinth upto 6 fit height on top of T/F plinth, including cost of all material and labour as per RESPO/drawing/Norms.
Providng & Fixing of MS Channel 100x50 mm as per RESPO/Norms.
Providng & Fixing of MS Angle 65x65x6 mm as per RESPO/Norms.
Removal of old & damaged conductor (scrap) 1950Kgs. and bundling of the same
Removal of old & damaged GI (scrap) 300Kgs. and bundling of the same
Carriage of old and damaged Conductor-1950Kgs. And G.I. 300 Kgs, from Site of work to JE Store/ESC Hapur with loading and unloading at both ends.
Jumpering work properly as per RESPO/Norms.
Vivek Electricals
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .