Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 CrAccepted-AOC | ₹17.7 Cr | L1 | Accepted-AOC Accepted being L1 Bidder |
| 2 | L2₹18.2 CrRejected-Finance | ₹18.2 Cr | L2 | Rejected-Finance Rejected 6being higher than L1 bidder. |
| 3 | L3₹18.6 CrRejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹18.6 Cr | L3 | Rejected-Finance Rejected 6being higher than L1 bidder. |
| 4 | L4₹18.8 CrRejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹18.8 Cr | L4 | Rejected-Finance Rejected 6being higher than L1 bidder. |
| 5 | L5₹19.1 CrRejected-Finance | ₹19.1 Cr | L5 | Rejected-Finance Rejected 6being higher than L1 bidder. |
Tender Value
₹17.8 Cr
EMD Value
₹12.2 L
Closing Date
27 Jun 2020, 6:00 pmClosed
CE (AF) SHILLONG ZONE
HQ CE (AF) SHILLONG ZONE, ELEPHANT FALLS CAMP, PO-NONGLYER, SHILLONG-793009
PROVN OF CERTAIN TECHNICAL STORAGE ACCNS INCLUDING SERVICES AT AF STN JORHAT
2020_MES_339582_1
88616/JOR/E8
Open Tender
Civil Works
540 days
GE (AF) JORHAT
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE (AF) JORHAT
₹12.2 L
Yes
HQ CE (AF) SHILLONG ZONE
4 Sept 2020
20 Apr 2020
4 Jul 2020
20 Apr 2020
27 Jun 2020
15 Jun 2020
20 Apr 2020 - 5 May 2020
5 May 2020
Amount
SCHEDULE "A" PART-I (BUILDINGS/STRUCTURES ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-II (SITE CLEARENCE, SITE DEVELOPMENT, EARTH WORK AND DEMOLITION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (FIRE POINT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SIGN BOARD) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (STATIC WATER TANK (225 KL)) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XII (ELECTROSTATIC DISCHARGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XIII (LIGHTENING PROTECTION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIV (AIR CONDITIONING) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
Supply, Installation, Testing and Commissioning of Chilled water Central Air-conditioning system of capacity not less than 60 TR ( 30 TRx2 working and 30x1 TR standby ) including following items and other items as required for satisfactory performance of the plant complete in all respect for DBs all as specified in respective drawings to achieve the inside design conditions as per ANNEXURE ‘A’ enclosed here-in-after : Note 1:- (a) Contractor / bidder should submit complete design for the Central AC plant comprising of heat load calculations, Duct layout and working drawings of complete AC plant supported with design/calculations of each component duly vetted by IIT/NIT/OEM within two months of the date of commencement of work through GE for the approval of Accepting Officer before execution of the work. (b) Contractor/bidder will be responsible for performance guarantee of complete AC plant to achieve the inside design conditions round the clock throughout the year with overall COP of the system not less than 3.
SCHEDULE "A" PART -XV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
FIRE POINT Materials and Labour Exterior emulsion paint ( weather coat) of any shade / tint, two coat over a coat of primer on new external surfaces including necessary preparation of surfaces complete all as specified and as directed.
RETAINING WALL M&L Bringing approved earth from outside MD land complete all as specified and as directed. Note:- (i) Before execution of this item earth shall be tested/checked for suitablity to use.
STATIC WATER TANK Supply and fixing of 250mm x 10mm PVC water stop for construction joint in RCC during construction of different work complete all as specified and as directed.
M&L for earting complete with copper plate electrode 30cmx30cmx3.15 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to copper strip 25x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earting test point all as specified or indiealed complete with excavation & earth work, PCC pit with 50mm thick RCC cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) forprotection of earth lead conductor all as directed and testing on completion. (Lightening Protection -24, External Electrification - 02 & DG Set - 02 )
ELECTROSTATIC DISCHARGE - Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3034. The outer and inner pipe should be 48.3mm &26.4mm 3mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional corrosion protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity The job includes digging the pits and refilling the same by Electrodite/Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth is to be arranged to fill the excavated pits by mixing the same with BFC 2or3 bags (as per soil condition). including PCC pit in cement concrete 1:3:6 (20mm graded stone aggregate) and RCC cover of size 450 x 450 x50mm in RCC 1:2:4 (20mm Graded stone aggregate) reinforced with and including 8.0mm dia TMT bars @ 100mm centre to centre both ways complete all as specified and directed. Make : ASHLOK / INDELAC / MACKMET / JMVLPS LTD
INTERNAL ELECTRIFICATION. S&F Flame proof switch fuse unit with HRC fuse 16 Amps double pole all as specified and directed.
S&F MCB SPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed.
S&F LED T-8 tube light fittings 4 Ft, flame proof type of 2 x 20 watt made of aluminium alloy, heat resistant, IP-65, etc and all accessories pre wired and including 2 Nos 20 Watt LED tube connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed.
S&F LED Retrofit Wellglass light fitting, flame proof type FLP-WP of 1X20 watt made of aluminium alloy LM6 with heat resistant and toughened glass cover,, painted MS wire guard and eye bolt including 01 No 20 watt LED lamp with connector block, etc and all accessories complete all as specified and as directed.
Supply and fix 20 watt integrated LED tube light fittings 4 ft, suitable for single phase 230 Volts, 50 Hz AC supply and mounted on wall or ceiling, complete with all accessories internally prewired and including electrically connection with copper conductor cable of size 0.5 Sqmm(nominal area) all as specified.
S&F ceiling fan 1400 mm sweep 240 volt AC white colour and including connected with twin core twisted flexible wire copper conductor cable of suitable size complete all as specified and directed. Make:- Havells model No. SS 390 or equivalent from make list as specified in PS.
S&F Exhaust fan 300 mm sweep 240 volt AC and including connected with twin core twisted flexible wire copper conductor cable of suitable size complete all as specified and directed. Make:- Havells model No. Ventil Air-DB or equivalent from make list as specified in PS.
S&F distribution board flame proof 3 Phase TPN 4 ways including MCCBs as outgoing all as specified and directed
EOT CRANE. Design, supply and installation, testing & commissioning of flame proof electrically operated over head travelling EOT crane, double girder type having span of 9.5 m, long travel 36m, clear hook height 3.0 m and weight lifting capacity of 5.0 Ton with mobile pandent control system considering following conditions complete all as specified and directed:- (i) Height available for working/ staking of equipments should be 3.0 meter and rest hight is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4 m/min (b) Micro in main Hoist - 0.4 m/min. (c) Cross travel - 5 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 10-15m/min (f) Micro in long travel- 1.0 m/min (iii) EOT crane fitted should be comply with the safety specification such as limit switches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc IS-807, IS-3177, IS-3938.fire/flame proof and comply with the safety specification. (iv) Design of crane and proof checking of design from any of Govt Chatered Engr within 2 months from the date of accept of tender. Note :- Crane should be provision of load cell with digital display of load for monitoring the lifting load including cut off facility incase exceeding from the rated load.
Design, supply and installation, testing & commissioning of flame proof electrically operated over head travelling EOT crane, double girder type having span of 4.5 m, long travel 19.0m clear hook height 4.20 m and weight lifting capacity of 5.0 Ton with mobile pandent control system considering following conditions complete all as specified and directed:- (i) Height available for working/ staking of equipments should be 4.2 meter and rest hight is to cater for crane installation. (ii) The operation and micro speed of crane should be as following:- (a) Main Hoist:- 3-4m/min (b) Micro in main Hoist - 0.4 m/min. (c) Cross travel - 5 m/min (d) Micro in cross travel - 0.5 m/min (e) Long travel - 10-15 m/min (f) Micro in long travel- 1.0m/min (iii) EOT crane fitted should be comply with the safety specification such as limit switches, alarm, guards, isolating switches, emergency stop button and interlocking, power and control cabling complete etc IS-807, IS-3177, IS-3938.fire/flame proof and comply with the safety specification. (iv) Design of crane and proof checking of design from any of Govt chartered Engr within 2 months from the date of accept of tender. Note :- Crane should be provision of load cell with digital display of load for monitoring the lifting load including cut off facility incase exceeding from the rated load.
EXTERNAL WATER SUPPLY. M&L Ductile Iron (DI) pressure pipe with spigot and socketed ends, centrifugally cast, Class K7 confirming to IS:8329 with internal metalic zink coated and external black bituminus coating suitable for push on joint (tyton) in any length of 100mm bore laid in trenches complete all as specified and directed.
M&L Construction of brick massonry valve pit chamber of inner dimension 100x100x10 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, including MS sheet cover of thickness 3.15 mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exc 50 m complete all as specified and directed.
S & F 80mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket complete all as specified and directed.
S & F 100mm bore, cast iron sluice valve both end flanged, class PN 1.6 conforming to IS -14846 with iron wheel head and stainless steel spindle including necessary jointing materials like nuts, bolt, washer & rubber/fiber board gasket complete all as specified and directed.
EXTERNAL ELECTRIFICATION M &L steel tubular swaged poles and complete with cast iron / M.S base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 mtrs long) including painting with two coats of aluminium paint over a coat of red oxide metal primer complete all as specified and directed by Engr-in-Charge. Note:- The pole shall conform to IS 2713:1980 and each component pipe shall be ISI marked and conform to IS 1161.
M&L Lightening arrestor non linear resistor type conforming to IS 3070 (part-3) 1993 complete, line discharge class-3, nominal discharge current 10KA (peak) , 12KV rated system, voltage peak value high current implus of 4/10 mocro Sec. wave shape 100 KA (peak) assembly suitable for 11 KV ,long duration descharge class-II with insulation level 28/75 KV and mounted on hot dip galvanized steel structure including all clamps, nuts, bolts and washers and connecting to earth with 34mm GI wire complete in existing pole all as specified and directed.
Switch air break gang operated HT 11 KV Volt grade triple pole with 15 insulators, 200 amps rating with drop out fuse assembly with fuse carrier, fuse element mounted on insulator and fitted on steel frame horizontally operated(rotory type) mechanism from ground level consisting of operating rod of 25mm bore medium grade GI pipe ISI marked of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x 6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts, and washers complete in existing pole all as specified and directed. Note:- Channel, cross arms, bracings etc shall be measured and paid separately.
Transformer floor mounted capacity 200 KVA, step down, outdoor type11/0.433 KV,50Hz, AC double wound core type copper wound ,oil immersed ,air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connection on LV side in accordance with vector symbol DyN-11 ( vector group 4) and having tapping of + 7.5% in equal step of 2.5 % changed by means of off load tap changing arrangement. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings /accessories as specified in SSR Part -I and IS -1180 Part I 2014 Level-II. The transformer should have cable box on LT side and brass bushing on HT side . The limit of temp rise after continuous full load run as specified in SSR part-I and IS -2026 shall be suitably adjusted to suit the maximum ambient temp prevailing at site all as specified comprising with and including the following specifications:- i) 01 No Cable box on LT side consisting of 04 Nos porcelain bushing with bushing brass rods and nuts washers and cable glands of suitable for reception of cable LT 1100 Volt grade XLPE insulated heavy duty including gland joint complete. ii) HV bushing with arching horn on 11 KV side. iii) Oil Conservator with filter type drain valve and oil level guage. iv) Dehydrating Breather with first filling of Dehydrating Agent . v) Explosion Vent. vi) Thermometer Pocket vii) Two Earthing Terminal on tank body to facilitate fixing of 32x6mm GI strips. viii) One No Thermometer Dial type vapour pressure type having range 0-120 degree centigrade with maximum temprature indicator and re-setting device to maximum temprature including needle of temperature gauge : Max reading painted terminal. ix) Rating plate with terminal marking plate. x) Oil level guage.
S&F Compact air insulation rising main panel 4 way with aluminium busbar 600 Amps breaking capacity of 35 KA IP 54 protection complete all as specified and directed.
S&F cubical husing cabinet type LT panal board OUT door type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 14 SWG(3.15 MM) thick CRCA MS sheet or overall size 1200mm (height)x 1000mm (width)x600mm(depth) and built upon suitable size angle iron frame work , having front and raar hinged doors, GI earthing strips at rear side , bottom detachable grand plate complete with suitable size zink plated and passivated nut, bolts, spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coatred paint (RAL-7032). The panel should be suitable for 415 volts , 50Hz, 3 phase, 4 wire system and internal connection should be provided with aluminium strip of suitable size and necessary foundation work and comprising following:- BUS BAR CHAMBER:- (a) Sheet steel bus bas bar chanber having front hinged covers with a set of electrolytreic grade high conductivity TP&N solid aluminium bus bars , rated 400 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded (red, yellow and blue for three phases and black for neutral). at requierd intervals for identification INCOMER:- (a) MCCB 250 amps, 415 volt, 25 KA Breaking capacity 4 pole duly connected to bus bar As in coming - 01 No. OUTGOING:- (a) MCCB 100 amps , 415 volt, 50 KA Breaking capacity 4 pole duly connected to Bus Bar As out going - 01 No (b) MCCB of 4 pole of capacity 32 amps , 415 volt, 16 KA Breaking capacity 4 pole duly connected to Bus Bar As out going - 03 No
S&F loop in and loop out box outdoor termination with transparent lid, IP-66, Halogen free weather proof of size 167 x 125 x 82 mm, suitable for 10 sqmm x 4 core cable fixed to pole with suitable size, FI clamp 20 x 3 mm, nuts, bolts and washers complete all as sepecified and directed. Make:- Hensal Cat No. K-9105 or equivalent as per Approved names of manufacturers as per tender.
Street ligh fitting 90 W LED made up of pressure die cast aluminum housing with toughened glass and high power LED and secondary lenses with IP 66 and 10KV SPD complete with bracket (made out of GI tubing 1.2 M long) complete including electrical connection from junction box to fitting complete all as sepecified and directed.
S&F MCB TNP 32 Amps, C curve, breaking capacity 10 KA 415 Volt with cable connection and copper LUX complete all as specified and directed
S&F MCB TNP 32 Amps, C curve, breaking capacity 10 KA 415 Volt with cable connection and copper LUX complete all as specified and directed
S&F Stay assembly complete including accessories like 20mm stay rod, loop type insulator, stay clamps, excavation and concrete foundation all as specified and as directed
M&L for PVC insulated two core 2.5sqmm multistrand copper conductor for conection of security light from junction box to security light in HDPE pipe all complete as specified and directed.
M&L for earting complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earting test point all as specified or indiealed complete with excavation & earth work, PCC pit with 50mm thick RCC cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) forprotection of earth lead conductor all as directed and testing on completion complete as specified and directed. ( For External Electrification - 04 & DG Set - 04)
Supply install testing and commissioning Silent type Diesel Engine Generating set 415 volts 200 KVA/ nearest higher size available KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator installed including acoustic enclosure suitable for ambient condition at Jorhat and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 with following: (i) The capacity of Generator set shall be net after all due derating factors as per relevant IS/BS Standards design. (A). Alternator :- Standard design alternator rated at 200 KVA/ nearest higher available capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. i) Insualation class - 'H' ii) Temparature rise Class - 'H' iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with + 1%. v) Frequency regulation + 1%
Serial Item No.15.40 (Contd...) (B) Diesel Engine: - Adquate capacity of Diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditons after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant IS/BS complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i) Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts. iii) Cooling Water pump : - Centrifugal type belt driven. iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade. Turbo charger type Exhaust manifold Silencer : Residential type v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electric operated/ (as recommended by OEM) for 1% speed /frequecy regulation. Fuel filters Fuel hoses vi) Lub oil System :- Lubricating oil filter Lubricating oil pump vii) Air Intake System :- Air intake Manifold Air cleaner dry type viii) Governer mechanical type ix) Starting System :- Electric Self starter with and including battary charging alternator 24 Volts DC.
Serial Item No.15.40 (Contd...) x) Batteries :- Batteries of maintenance free of capacity 12 V, 150 AH- 02 No complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified. Start and stop push button Ignition key / Switch Radiator with blower fan & first fill of coolant oil Corrosion inhibitor coolant Direct fuel injection system through governer mechanical type xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine. xiii) Coupling arrngement : - Flexible coupling xiv) Accessories :- AVM Pads built- in or separtely mounted to manufactrer base frames. xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer. xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set. xvii) Battery Charger shall be provided as per manufacturer guidelines C) Civil Works :- All civil works including PCC plat form and related foundations including for panel and equipments including making good of distrubed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer. Note:- The contractor shall arrange for artificial load for testing of DG Set at site and the cost is deemed to be included in the above offer.
SEWAGE DISPOSAL :- Construction of brick masonry Septic Tank, 100 users capacity complete all as specified and shown on drawings. Reference:- Drg No: AF/TD/233 Sheet 1/2 & 2/2.
Construction brick masonry Soakage Well for 100 users all as specified and as shown on drawings. Reference:- Drg No: AF/TD/STRU/236 Sheet 1/2 & 2/2.
REMOTE MONITORING AND CONTROL SYSTEM Supply Installation Testing and commissioning of programmable Remote Terminal Unit with following specifications:- (a) Input Out put as per requirement in our system (b) RS 485 Communication Port (c) Digital inputs (optical isolation) (d) Digital outputs (e) Isolated Analog Inputs for monitoring of Temperature & humidity (f) Local Display, membrane key board and data storage (f) Compatibility with GSM Modem Make:- Siemens/ABB/Schnider/ L&T. Note:- TO BE INSTALLED AT AC PLANT ROOM.
Supply Installation Testing and commissioning of MS Powder coated CRCA 1.6 mm Thickness Outdoor Panel of minimum size 600 x600 x 300 mm for indicator complete all as specified and as directed. Make:- Siemens/ BCH / Rittal /Safetek / Powertek.
Supply Installation Testing and commissioning of Digital Energy Meter for the Chiller Plant Motor Energy Data Monitoring complete all as specified and as directed. Make:- Enercon/Trandata/Siemens/L&T
Supply Installation Testing and commissioning of Wireless modem suitable for GSM/GPRS based communication system; to be mounted in RTU enclosure complete all as specified and as directed. Make:-Siemens/Motorola.
Supply Installation Testing and commissioning of RTD sensor for the room temperature measurement complete all as specified and as directed. Make:- BAUMER/ RADIX/ Masibus/Wika.
Supply Installation Testing and commissioning of Humidity sensor with transmitter for the room Humidity measurement complete all as specified and as directed. Make:- Masibus/Wika / baumer / Radix.
Supply Installation Testing and commissioning of of Process Indicator of 48x48 mm with retransmission output for monitoring of temperature and humidity complete all as specified and as directed. Make:- MULTISPAN / Radix/Masibus
Supply & Installation of 2 Core x 1.5 sq mm PVC coated Armoure Copper control cable complete all as specified and as directed.
Supply &Installation of 3 Core x 1.5 sq mm PVC coated Armoured Copper control cable complete all as specified and as directed.
Supply Installation Testing and commissioning of of Intel Core i3 Processor or equivalent at minimum 2.00 GHz ( 2 MB L2 cache ) , Intel Server Based Motherboard with minimum 800 Mhz BUS Speed , 2 GB DDR 2 SDRAM@ 667 Mhz , 160 GB SATA HDD , DVD Writer , 2 x USB 2.0, 2 x Serial Port, Gigabyte LAN 23" TFT Display Monitor with Resolution of 1440 x 900 Pixel and Support 16.2M Color with required software complete all as specified and as directed. Make:- HP / Dell / HCL / ACER.
Supply Installation Testing and commissioning of License verson software windows-7, MS Office and antivirus Software complete all as specified and as directed.. Make:- Quick Heal/ Mc Afee/ K7.
Supply Installation Testing and commissioning of UPS-600VA, 230 V AC, 15 min Backup complete all as specified and as directed. Make:- APC/Microteck
Supply of Laser Printer with Scanner A-4 Black & White print complete all as specified and as directed. Make:- HP/Canon/Samsung
Supply Installation Testing and commissioning of SCADA software License Version with required tags for Central Monitoring and control Through wireless communication for Master Control Station complete all as specified and as directed. Make:- Siemens/ABB/Schnider/ L&T.
Supply and fixing Rigid steel conduit, welded of 20mm diameter to walls, roof etc complete all as specified and as directed. Make:- BEC/AKG/Jindal.
Supply Installation Testing and commissioning of GSM Sim Card Rental and SMS charges for the period of TWO year. - 2 No. of SIM CARD ( 1 sim Card Charges = 210/- per month).
HANDLING ROLLER TROLLEYS Epoxy powder coated Body premium series hand pallet truck capacity 2500 Kg, fork length 1220 mm, Fork span 550mm, rollers polyurethane ( Twin roller per fork)
LIGHTENING PROTECTION M&L Aluminum wire of size 4.30mm for fixing on H beam all as specifed and directed
PRIME COST SUM. The prime cost is to used as directed by the Accepting Officer vide condition 1(v) and 5 of IAFW-2249. (a) Provide a prime cost of Rs. 6,00,000.00 for Provision four sets of Steel Roller Treadway (Each Set consists of two Nos Steel Roller) in all the 02 Igloo Buildings as approved by GE. (b) The contractor is to quote the amount in the money column i.e. in Col 'F' adding his overhead and profit. The amount shall be adjusted proportionately to the sum actually expended against Prime Cost Sum. Notes :- (i) Item(s) covered under Prime COst Sum shall be ordered as per condition 5 of IAFW-2249. (ii) Contractor shall quote amount adding over the amount of prime cost sum to cover his overhead and profit against Srl Item No 15.41(a).
SCHEDULE "A" PART-XVI (SCHEDULE OF CREDIT) Note :- Amount of Rs. 39031.50 indicated in Tender shall be deducted from the total quoted amount of BOQ.
Allied Construction
Phoenix Infra
MAA BHAGWATI ASSOCIATES
SARINS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid