Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.7 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹30.1 L+₹1.6 L (5.77%)Rejected-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | 2 | Rejected-AOC Higher | |
| 3 | 3₹37.8 L+₹9.3 L (32.7%)Rejected-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 3 | Rejected-AOC Higher |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Dec 2021, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
Repair/Maint of DG Sets, MT Veh, Earthing and misc works at NAMS.
2021_MES_487162_1
GE NAS - 69 / 21 - 22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹90,000
Yes
1 Feb 2022
9 Nov 2021
8 Dec 2021
9 Nov 2021
7 Dec 2021
25 Nov 2021
Amount
To depute service representative minimum for 01 visit to attend the DG set at frequency as per schedule or after 250 working hours. Service Representative will Carry scheduled preventative maintenance checks on Diesel Generating Set (of any make ) and carry out the the undermention Jobs during his visit for DG Set 25 KVA to 30 KVA.
(A) Check List for minimum core of work
Check the sample of coolant concentration
Check the fan belt for tension and inspect it. If needs any replacement
Check the exhaust mani fold out let
Examine the charge level of the battery and check for any loose connection
Check the air cleaner components and clear them if any dirt occures
Check and adjust the voltage level of the battery charger
Drain out water from the container of the bottom of the filter housing and fuel tank
Checking of control panels wiring, instrumentation, contactor fuses etc.
Check the serviceability of safety controls of engine
Checking of all electrical connections for its proper tightness
Check AVR connections & power cable connections for tightness
Check the RPM/frequency and adjust it.
Check the condition of wire breaded/nonbreaded hoses of engine.
Checking of load balancing of alternator/AMF panel output
Ditto as items No 2 above but DG Set of Cap 40 to 65 KVA
Ditto as items No 2 above but DG Set of Cap 100 to 250 KVA
Servicing of DG Set including replacement the fwg item of company approved make for DG Set of cap 25 to 30 KVA
Diesel fitter.
Lub oil filter.
Radiator hose pipe set.
Fan belt.
Air filter element
Servicing of DG Set including replacement the fwg item of company approved make for DG Set of cap 40 to 65 KVA
Diesel fitter.
Lub oil filter.
Radiator hose pipe set.
Fan belt.
Air filter element
Servicing of DG Set including replacement the fwg item of company approved make for DG Set of cap 100 to 250 KVA
Diesel fitter.
Lub oil filter.
Radiator hose pipe set.
Fan belt.
Air filter element
Dis-connecting the fuel pipes from the Fuel Injection Pump Assembly, taking out the FIP assembly from the engine body and transporting to the workshop to carry out the following for DG of 25 to 30 KVA (i) Dis-mantling the complete FIP, taking out all the parts, cleaning the internal/external surfaces of the pump (ii) replaceing the suction & delivery valves, rollers and other worn out parts. (iii ) Assembling the parts, filling correct grade of oil ,testing for smooth functioning. (iv) Calibrating the FIP for correct fuel pressure. (v) Transporting the FIP from the workshop to site and fitting the FIP assy to the engine.
Dis-connecting the fuel pipes from the Fuel Injection Pump Assembly, taking out the FIP assembly from the engine body and transporting to the workshop to carry out the following for DG of 40 to 65 KVA (i) Dis-mantling the complete FIP, taking out all the parts, cleaning the internal/external surfaces of the pump (ii) replaceing the suction & delivery valves, rollers and other worn out parts. (iii ) Assembling the parts, filling correct grade of oil ,testing for smooth functioning. (iv) Calibrating the FIP for correct fuel pressure. (v) Transporting the FIP from the workshop to site and fitting the FIP assy to the engine.
Dis-connecting the fuel pipes from the Fuel Injection Pump Assembly, taking out the FIP assembly from the engine body and transporting to the workshop to carry out the following for DG of 100 to 250 KVA (i) Dis-mantling the complete FIP, taking out all the parts, cleaning the internal/external surfaces of the pump (ii) replaceing the suction & delivery valves, rollers and other worn out parts. (iii ) Assembling the parts, filling correct grade of oil ,testing for smooth functioning. (iv) Calibrating the FIP for correct fuel pressure. (v) Transporting the FIP from the workshop to site and fitting the FIP assy to the engine.
M & L for draining out old engine oil from the DG Set and replace with new oil at recommended by manufacturer complete all as specified and directred.
Repair overhalling of self starter including replacement of worn out clutch assembly bush, spring, plunger assembly ,solenide switch, corbon brushs, spring etc for the following DG set.
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
M & L for topping up of water coolent in radiotor of DG set TVS Girling/volvo line or of equivelent make all as directed by EIC.
Cleaning of the fuel tank of DG sets of following capacity after decaning the diesel, through cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by EIC.
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
Dismantling and removing of water pump assesmbly complete from the engine repair/overhauling the same by replacing worn out components like bearing, impeller,bushes,oil seal, water seal, gasket etc. reassembling,refixing and testing complete for the following :-
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
Reapair/overhaling of dynamo/ charging alternator including replacement carbon,brushesholder,spring,commutator/slipring assembly bearing,regulator etc. of any make,type and capacity.
Supply and fix in replacement of automatic voltage regulator suitable for DG set of following rating :-
25 KVA to 30 KVA
40 KVA to 63 KVA
100 KVA to 110 KVA
M & L for replacement of electrically operated fuel shut down valve assembly for 25 to 250 KVA DG set complete testing and commissioning as specified and directed by EIC.
M & L for replacement of moulded rectifier assembly complete as per exisiting one of 25 to 250KVA alternator excitor unit complete all as specified & directed .
M & L for replacement of PVC flexible wire breded fuel pipe suitable for Gen set of capacity 25 KVA to 250 KVA complete all as specified & directed .
Dismantling of radiator of DG set and for servicing/cleaning with dismantling twin tanks, replacement of gasket packing , nuts ,bolts , washers ,descaling with appropriate chemical and welding copper brazing of damazed fins/tubes and reassembling & refixing of following capacity in same position after testing complete all as specified & directed .
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
M & L for replacement of flexible rubber cuopling suitable for DG set 25 KVA to 110 KVA complete all as specified & directed .
M & L for replacement of engine start relay 12/24 Volts. Make:- PIC / Technica/ Indo Econ complete all as specified & directed .
Repair to battery 12 Volt 180 AH including removing of old cell/plate and supply and replacement of positive plate /cell and negative plate / cell filling of electrolight 1150 gravity chargeing fix on gen and taking complete all as spd and directed by EIC.
M & L for replacement of battery terminals brass with steel nuts, bolts & washers .
M & L for replacement of PVC insulated battery lead stranded copper conductor of size 50 Sq mm suitable pices with bothend copper lugs complete all as specified & directed .
Painting of DG set by scrapping of old paint complete and painting with two coats of synthetic enamel paint over a coat of red oxide primer and writing SM/MES No of fwg size complete all as specified & directed.
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
Dismantling of exhaust mani fold assembly complete and repairing, cleaning complete with wire brush necessary welding and refixing with required new bolts/nuts complete all as directed for DG set of 25 KVA to 250KVA Capacity.
Taking out the old rusted silencer in beteween exhaust pipe engine and providing new low noise silencer (Residential type) and fixed with gasket, nutbolts washer and asbestoss rope complete all as specified and directed for DG set of 25 KVA to 250KVA Capacity.
Repair/replacement of injector nozzle including testing pressure as per required for DG set of fwg size complete all as specified & directed.
25 KVA to 30 KVA
40 KVA to 65 KVA
100 KVA to 250 KVA
M & L in replacement for Changeover switch 200 Amp off load side handle 4 pole, 415 Volt complete all as specified & directed .
M & L in replacement for Changeover switch 63 Amp off load side handle 4 pole, 415 Volt complete all as specified & directed .
M & L in replacement for Changeover switch 100 Amp on load side handle 4 pole, 415 Volt complete all as specified & directed .
M & L in replacement for Changeover switch 200 Amp on load 4 pole, 415 Volt complete all as specified & directed .
M & L in replacement for 63 Amp MCCB, 4 pole, 25 KA , 415 Volt complete all as specified & directed .
M & L in replacement for 100 Amp MCCB, 4 pole, 25 KA , 415 Volt complete all as specified & directed .
M & L in replacement for 250 Amp MCCB, 4 pole, 35 KA , 415 Volt complete all as specified & directed .
M & L in replacemet of control wiring of DG Set as per existing size of copper wire connected complete to the panel with provision of all wiring codes all as reqd insert the panel.
Supply only distilled water for battary complete all as specified & directed.
Supply and fixing in replacement of asbestoss rope for exhuest pipe complete all as specified & directed.
M & L for in replacement of fuel tank cubical/cylindrical type made up of 2mm thick MS sheet for accomodating 200/250 ltrs diesel complete all as specified & directed.
Dis-connecting the alternator from the engine by removing the coupling, transporting the alternator complete to workshop for repairs: upto 63 KVA (i) Rewinding and Cleaning the armature complete, applying one coat of varnish and heating complete (ii) replacing the damaged rectifier unit including filter circuit elements complete. (iii ) replacing the wornout carbon brushes – 01 set Assembling the alternator complete at workshop and testing at NO load , transporting the same to the site , connecting the alternator to the engine after proper alignment including replacement of coupling , key complete all as directed by the engineer in charge.
Dis-connecting the alternator from the engine by removing the coupling, transporting the alternator complete to authorized maintenance service center for repairs: 100 to 250 KVA (i) Rewinding and Cleaning the armature complete, applying one coat of varnish and heating complete (ii) replacing the damaged rectifier unit including filter circuit elements complete. (iii) replacing the wornout carbon brushes – 01 set Assembling the alternator complete at workshop and testing at NO load , transporting the same to the site , connecting the alternator to the engine after proper alignment including replacement of coupling , complete all as directed by the engineer in charge.
M & L for scraping the existing paint of Canopy of DG set , Cleaning the rusted portion complete , and applying two coat colour of existing paint all as required at site from 25 to 63 KVA.
M & L for scraping the existing paint of Canopy of DG set , Cleaning the rusted portion complete , and applying two coat colour of existing paint all as required at site from 100 to 250 KVA .
Repair/maint of EOT crane 5.00 Ton/ 2.00 Ton cap in frequency of every 6 months ,checking of control panel, control wiring, gear box, limit switches horizontal/Cross / Up / down travel, motors gear box etc including oiling, greasing, load testing complete all as specified and directed by Engr-In-Charge.
Supply & fix in replacement travelling cable copper conductor 03 Core 6 Sqmm
Do as per ser No 47 but 4 Sqmm
Supply and fix in replacement of control panel comprising of the fwg:- (i) Contactor 415 volt, 32 Amp, 03 pole- 06 Nos. (ii) Timer switch- 02 (iii ) Relay- 02 Nos (iv) Control panel wiring - 01 Job
Supply and fix in replacement of limit switch
Supply and fix in replacement of wire rope 3/4" dia
Supply and fix in replacement of wire rope 1/2" dia
Taking out electric motor 2 HP dismantling , taking out burnt winding wire and rewinding with new supper enameld copper wire baking, vernishing etc and reassembling testing complete.
Taking out electric motor 3 HP dismantling , taking out burnt winding wire and rewinding with new supper enameld copper wire baking, vernishing etc and reassembling testing complete.
Supply and fix in replacement of bearing suitable for 2 HP motor
Supply and fix in replacement of bearing suitable for 3 HP motor
Supply and fix in replacement of long travel shaft pillar block bearing as per existing size.
Supply and fix in replacement mannual operated suspended type control switch panel consisting of push botton 08 Nos for up/down, reverse, fwd, start and stop.
Servicing/reparing of AMF Panal for DG Set capacity 25 KVA to 63 KVA 3 Phase, 415 Volt including disconnecting the all connection and taking out old UNSV item, replacing the fixed/moving parts ,contactor,relay and cleaning dust and providing the proper size of lugs, nuts and bolts complete all as specified and directed (Note: Materials/parts for replacement will be measure and paid seperatley
Servicing/reparing of AMF Panal for DG Set capacity 100 KVA to 250 KVA 3 Phase, 415 Volt including disconnecting the all connection and taking out old UNSV item, replacing the fixed/moving parts ,contactor,relay and cleaning dust and providing the proper size of lugs, nuts and bolts complete all as specified and directed (Note: Materials/parts for replacement will be measure and paid seperatley
Supply and fix in replacement battery charger SMPS 12 Volt 6 Amp all as sp and directed.
Supply and fix in replacement line voltage Monitor (Digital) 3 Phase 415 V all as sp and directed.
Supply and fix in replacement contactor 100 Amp 3 Phase 4 pole 415 V all as sp and directed.
Supply and fix in replacement contactor 400 Amp 3 Phase 4 pole 415 V all as sp and directed.
Supply and fix PVC insulated single core multistrands copper wire 50 sqmm all as sp and directed.
Supply and fix digital VAF meter 3 phase 415 V all as sp and directed.
Supply and fix inreplacement of Indicator complete all as sp and directed.
Supply and fix Micro processor based Gen Set Controle 12 Volt all as sp and directed.
Supply and fix Micro processor based Gen Set Controle 24 Volt all as sp and directed.
Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 50 Sq mm 4 core all as sp and directed . Note : The cost of Aluminium thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and fix in replacement of Galvanised iron strip 32x6mm burried in the ground/pipe/wall and dully connected to machinery with nuts bolts washers and thimbles complete all as sp and directed.
Repair to self starter including taking out from veh Tata Xenon /Tata 207 dismantling including supply and replacement of the fwg spares parts, reassmbling, commissioning and testing all as directed by Engr-In-Charge:-
Solonoid switch
Self armature
Copper brush set
Re-tapping of field coil
Repair to self starter including taking out from veh EICHER dismantling including supply and replacement of the fwg spares parts, reassmbling, commissioning and testing all as directed by Engr-In-Charge:-
Solonoid switch
Self armature
Copper brush set
Re-tapping of field coil
Repair to self starter including taking out from veh Car Ambassador dismantling including supply and replacement of the fwg spares parts, reassmbling, commissioning and testing all as directed by Engr-In-Charge:-
Solonoid switch
Self armature
Copper brush set
Re-tapping of field coil
Repair to clutch system including dismantling and supply & replacement of fwg spares/parts including reassembling and testing complete all as specified and directed:-
TATA XENON 207/EICHER
Clutch plate
Pressure plate
Clutch release bearing
Clutch cylinder lower
Clutch cylinder upper
(b ) CAR AMBASSADOR
Clutch plate
Pressure plate
Clutch release bearing
Clutch cylinder lower
Clutch cylinder upper
Repair to rediator by dismatling and taking out rediator from vehicle including opening of upper tank and lower tank and rectify the leakage by gas welding of copper tube and cleaning of rediator tube with acid and re- assembling the same after testing and commissioning complete all as specified and directed for TATA Xenon/TATA 207.
Repair to rediator by dismatling and taking out rediator from vehicle including opening of upper tank and lower tank and rectify the leakage by gas welding of copper tube and cleaning of rediator tube with acid and re- assembling the same after testing and commissioning complete all as specified and directed for EICHER.
Repair to rediator by dismatling and taking out rediator from vehicle including opening of upper tank and lower tank and rectify the leakage by gas welding of copper tube and cleaning of rediator tube with acid and re- assembling the same after testing and commissioning complete all as specified and directed for Car Ambassador.
Dismantling and taking out defective water pump from vehTata Xenon/ EICHER supply and fix new water pump after testing and commissioning complete all as specified and directed.
Dismantling and taking out defective water pump from veh Car ambassador supply and fix new water pump after testing and commissioning complete all as specified and directed.
Repair to suspension system including supply and replacement of the fwg for EICHER :-
Suspension bush kit
Tie rod end rod set
Ball joint
Shock absorbers make: Gabrial
Repair to suspension system including supply and replacement of the fwg for Car Ambassador:-
Suspension bush kit
Tie rod end rod set
Ball joint
Shock absorbers
Taking out defective silencer assembly and replacing the same with new for TATA-207/EICHER/Car Ambasdor including replacing of the following parts complete all as specified and directed.
Crown wheel pinion
Bewel for differential system
Yoke and teeth
Repair to differential system including taking down UNSV defective part and supply and replacement of the fwg for TATA Xenon/207:
wipper machine with motor
Ignation switch with key set
Indicator/ brake light assembly
Head light assembly
Fog Light
Alternator assembly complete
Door lock assembly
Light and left mirror
Mud flap
Horn assembly complete set
Repair and replacement including taking UNSV defective parts and supply and fixing the fwg for EICHER:-
wipper machine with motor
Ignation switch with key set
Head light assembly
Fog Light
Alternator assembly complete
Right and left mirror
Mud flap
Glass winder
Door lock assembly
Indicator/ brake light assembly
Repair and replacement including taking UNSV defective parts and supply and fixing the fwg for Car Ambassador:-
wipper machine with motor
Ignation switch with key set
Head light assembly
Fog Light
Alternator assembly complete
Right and left mirror
Mud flap
Glass winder
Cut out fuse
Fuel pump assembly
Petrol pipe
Door lock assembly
Indicator/ brake assembly
Taking out fuel pump assembly and calibration with authrised wksp and re-fixing the same after testing and commissioning complete all as specified and directed for Tata Xenon,EICHER.
Taking out fuel pump assembly and calibration with authrised wksp and re-fixing the same after testing and commissioning complete all as specified and directed for Car Ambassador.
Removing old paint of veh cabin body, bumper, bounet & metalic surface with the help of blow lamp and rubbing with sandy paper complete all as specified and directed for EICHER.
Removing old paint of veh cabin body, bumper, bounet & metalic surface with the help of blow lamp and rubbing with sandy paper complete all as specified and directed for Car Ambassador.
Making good surface by denting welding patch work and apply putty prepared mettalic surface for paint for paint complete all as specified and directed for EICHER.
Making good surface by denting welding patch work and apply putty prepared mettalic surface for paint for paint complete all as specified and directed for Car Ambassdor.
Painting complete body of vehicle with two coat of red oxide paint and two coat of enamel paint with spray painting complete all as specified and directed for EICHER.
Painting complete body of vehicle with two coat of red oxide paint and two coat of enamel paint with spray painting complete all as specified and directed for Car Ambassador.
Taking out UNSV driver cabin seat assembly from veh repair the seat with the help of welding/replacing spring nut bolts etc and replacing and fixing new foam and superior quality rexine cloth and refixing the same to veh complete all as specified and directed for Veh TATA Xenon 207/EICHER
Taking out UNSV driver cabin seat assembly from veh repair the seat with the help of welding/replacing spring nut bolts etc and replacing and fixing new foam and superior quality rexine cloth and refixing the rear and front seat assembly same to veh complete all as specified and directed for Veh Car Assembly.
M & L in replacement of seat cover for rear seat and front seat complete all as specified and directed for Car Ambassador.
M & L in replacement for foot mat set complete all as specified and directed for EICHER.
M & L in replacement for foot mat set complete all as specified and directed for TATA Xenon 207.
M & L in replacement for foot mat set complete all as specified and directed for Car Ambassador .
Repair overhauling to 4 wheel brake assembly including replacing the fwg for EICHER complete all as specified and directed:-
Wheel cylinder assembly
Break shoe assembly set of two
Front wheel disc brake set
Brake master cylinder
Repair overhauling to 4 wheel brake assembly including replacing the fwg for Tata Xenon /Car Ambassador complete all as specified and directed:-
Wheel cylinder assembly
Break shoe assembly set of two
Front wheel disc brake set
Brake master cylinder
Servicing of veh including cleaning nipple gresing, engine tune up valve setting and replacing the fwg :-
Oil filter
Diesel filter
Air filter
Wheel bearing
Computer wheel alisgment
Testing of PUC certificate from authorized civil Govt Authority
Cotton wastage
Differential system oil 90 grade
Radiator coolent
Repair to name/number plate front/rear by replacing the UNSV number plate made out from MS Sheet duly writing of unit name, BA No, formation sign, Bdg classification in redium letter in front and rear side of veh.
M & L for replacement of old engine oil from the vehs and cleaning the oil sump throughly supply & filling new engine oil grade 20W 40 of Make : Servo super of Indian Oil all as specified and direcred by Engr-In Charge.
Servicing of motor cycle and repairing, cleaning washing greasing including replacement of fwg items:-
Air Filter
Clutch plate
Clutch chain
Main chain
Clutch housing
Seat cover
Indicator light
Brake show
Clutch wire
Mud guard rear
Battery Exide dry type
Brake wire
Mud guard front
Repair to aluminium ladder cabin / folding type trolley mounted of height 32/27 feet and carried out the foloowing:- (i) Removing the existing rusted/broken angle iron - 01 Job (ii) Supply and welding new MS Angle iron of size 50 x 50x 5mm - 30 Kg (iii) Taking out single drum winch with pully assembly with wire rope and repair/replacement - 01 Job. (iv) Supply and fixing in replacement wire rope of size 1/5" dia - 05 RM (v) Taking out 04 wheels with shaft and replacing with eixting size- 04 Nos
Dismantling of electric motor for rewinding with supper enameled copper wire of suitable gauge and complete servicing of air compressor and reassembling the same after repair/replacemnet of fwg parts:- (i) Pressure gauge- 01 Nos (ii) Pressure air pipe- 01 Nos (iii) Gate valve- 01 Nos (iv) Fan Belt- 01 Nos
Scrapping and rubing with emery paper of complete body air/water compressure and painting of air compressure with one coat of red oxide and two coat of enameled paint complete all specified and directed.
Dismantling of electric motor for rewinding of water compressure with supper enameled copper wire of suitable gauge and complete servicing of compressor and reassembling the same after repair/replacemnet of fwg parts:- (i) Water filling pipe, 3 ply heavy duty dia 6 mm suitable for water compressor - 10 RM (ii) Brass nozel- 01 Nos (iii) Pressure guage - 01 Nos
Supply and fixing inreplacement of inner tube with rubber ring complete size 2.75x18.
Supply and fixing inreplacement of inner tube with rubber ring complete size 165R/80.
Supply and fixing inreplacement of inner tube with rubber ring complete size 215R/75.
Supply and fixing inreplacement of inner tube with rubber ring complete size 7.50x16.
Supply and fixing inreplacement of Cover Outer complete size 2.75x18.
Supply and fixing inreplacement of Cover Outer complete size 165R/80.
Supply and fixing inreplacement of Cover Outer complete size 215R/75.
Supply and fixing inreplacement of Cover Outer complete size 7.50x16.
Material and labour for recondioning of lead acid battery capacity 80AH complete all as specified and directed.
Material and labour for recondioning of lead acid battery capacity 100AH complete all as specified and directed.
Cleaning and preparation of old painted surface of LT steel pole 09/11 mtr long excluding planting depth complete and painting with one coat of aluminium paint including channels/ brackets, street light brackets, cross arms and making black & white strips with synthetic enamelled paint 30cm height, each alternative strip upto 1.5 mtr height and applying two coats of white wash on PCC coping complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 60 watt LED Inverter street light with inbuilt RTC ( Real time clock) made of pressure die cast aluminium housing, Top maintainable and with clear heat resistant toughened glass, should have secondary lens for better optics, should have LM 80 certified LED with constant current RTC enabled electronic driver with 5KV SPD,IP66, Street light shall have inbuilt Li-ion battery of 5200mAH and shall have >1.5hrs battery back up in case of power failure, efficiency>100 LPW,CRI>70,THD<10%,PF>0.95,Cut of voltage at 300Volts = 10% and suitable for 40 mm mounting pipe.
Supply and fixing of 45 watt LED Inverter street light with inbuilt RTC ( Real time clock) made of pressure die cast aluminium housing, Top maintainable and with clear heat resistant toughened glass, should have secondary lens for better optics, should have LM 80 certified LED with constant current RTC enabled electronic driver with 5KV SPD,IP66, Street light shall have inbuilt Li-ion battery of 5200mAH and shall have >1.5hrs battery back up in case of power failure, efficiency>100 LPW,CRI>70,THD<10%,PF>0.95,Cut of voltage at 300Volts = 10% and suitable for 40 mm mounting pipe.
Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 25 Sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc . Note : 1. The cost of Aluminium thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, DWC protection pipe will be measured and paid separately under respective items.
All As per Item No 6 here in before but 16 Sqmm, 4 core
All As per Item No 6 here in before but 10 Sqmm, 4 core
Excavation in trenches in any type of soil by not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth below ground level for foundation of poles/ stays/cable and getting out complete all as specified .
Returning, filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as specified.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified .
Labour for drilling hole under the road with the help of drilling machine without damaging the road horizonally for rod crossing including laying GI tubing of any size for cable protection complete all as sp an directed.
M & L for sub class 'B' bricks (old size) for cable protection laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified in SSR and directed by Eng in charge.
M&L or sand cushioning with dry and clean sand in two layers first layers of 80 mm thick before laying of cables and second layers of 150mm including pinned down of sand complete all as specified and directed by Engr in charge Note- only pinned thickness of sand shall be considered for mesurement.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size75 mm outer dia and 61 mm inner dia complete all as specified and directed.
Labour for restaging of bricks for cable protection laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified by Eng in charge.
Repair of existing street light of any type or discription, fixed in vertical position with poles/wall including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like disconection of wire/cable, cleaning of carbon on OH line and replacing starter,fuses,drivers,lens plate, choke, bulb,etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed.
Supply and fixing in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories :-( For out going MCB & MCCB 100 AMPS 3 Pole measured and paid for separately)
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 6 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 12 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated, FRLS unsheathed and multi stranded copper conductor cable in and including new PVC Concealed conduit 20mm dia 1.5mm thick for one light / fan point or bell point controlled by one 5 Amp switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick hylem sheet top cover, sheet screws and sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed Note : The cost of sunken boxes and bakellite sheet is included in the quoted rate)
All as per item No 142 here in before but one three pin socket outlet 5 Amps independent board complete
All as per item No 142 here in before but one three pin 5 Amps socket outlet on the same board with other switches complete.
All as per item No 142 here in before but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper solid conductor connecting to common earth dolly complete.
Supply and Fixing in replacement switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
Supply and Fixing switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed
Supply and fixing in replacement ceiling rose 65X50 mm two to three terminals complete all as specified.
Material and labour for replacement of lamp holder insulated body with 10 Watt LED Bulb, back plate batten/angle type for batten fitting fixed on bakelite sheet 100mm x 100mm 230V AC cool day light 6500K having maximum height 1020mm heavy duty complete all as specified.
Supply and fixing in replacement fan regulator, electronic step type heavy duty socket type 230 volts complete all as specified and as directed.
M&L in replacement of sub main wiring 6 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 6 Sqmm as cotinuous earth wire connecting to common earth including connections of cable with MCBs or bus bars complete all as specified and directed
M&L in replacement of sub main wiring 4 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 4 Sqmm as cotinuous earth wire connecting to common earth including connections of cable with MCBs or bus bars complete all as specified and directed
M&L in replacement of sub main wiring 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 2.5 Sqmm as cotinuous earth wire connecting to common earth including connections of cable with MCBs or bus bars complete all as specified and directed
S&F Regid non-metallic PVC conduit of size 25mm dia including of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed
Supply and fixing in replacemnt of LED tube light fitting 1 x 28 watts decorative mirror optics luminaire including tube rod with anodised aluminium louvers and white engineering plastic end cover complete with rotory type bipin holder and including connection with PVC insulated three core 23/0.0076 flexible copper cable from ceiling rose to tube light fitting complet all as specified and directed.
Supply and fixing in replacement of LED T-8 tube light fitting with single side connection polycarbonate LED tube rod 18/20W 4 feet 1 x 18/20 watt box type including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Supply and fixing single the static whole current electronic energy meter single phase 10-60 Amps two wire of accuracy class 1.0, as per IS 13779 power factor unity to zero (all power factor lag/or lead ). starting current : 0.40 % lb , current 240 volt,50 Hz with LCD display. The meter shall be able to recording in Kwh/KVAH, MD, current load, V, Amp, Freq, etc burden of voltage circuit shall not exceed 1 VA. The shall have IEC 1107 port and shall be DLMS compatible for data reading. The meter should be immune to DC magnitic fields as per the CBIP 304. The meter should record the anti tamper features under the conditions mentioned as reversal of line load terminals, interchanging of phase and neutral wires, drawing of load by disconnecting neutral of meter & out going earth, meter body opening, neutral disturbance with transparent the pilfer proof meter box (PPMB) suitable to house single phase staatic energy meter. The meter shall be wall mounted type and have ability so as to offer protection of electrical equipment.
High grade fire retardant Engineering plastic (Acrylonitrile butadiene styrene / Polycorbonate, with minimum thickness 2.00 mm necessary sealing with lead meter and appropriate size copper lugs and necessary PCC work if reqd with existing surface complete at no extra cost including the fwg works including taking out existing meter and handed over to AGE E/M store Yard. (a) Connection of incomming and outgoing service cable /submain cable with meter is included in the quoted rate. (b) Sealing with the name of AGE E/M Punch and with lead seal and gi standard sealing wire.(c ) LCD test and display of all reading with battery back up for accessing reading during absence of electric supply. (d) The rate shall be included for testing and commissionoing alongwith preparation of documentation and submitting in triplicate.
BLANK
Supply and fix in replacement of Galvanised iron strip 32x6mm burried in the ground/pipe/wall and dully connected to machinery with nuts bolts washers and thimbles complete all as sp and directed.
Supply & fix in replacement of single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as spd and directed
Supplyand fixing in replacement of MCB 'C' series breaking cap 10 KA single pole 6 to 32 Amps all as specified and directed
S & F in replacement of MCB 40 amps'C' series breaking cap 10 KA single pole with neutral, AC 230 volts complete all as specified and directed.
Supply & fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
Supply and fixing in replacement PVC insulated, PVC sheathed, multistranded copper conductor wire 2.5 Sqmm size, twin core all as specified and directed.
Supply and fixing in replacement PVC insulated, multistranded copper conductor wire 2.5 Sqmm size, single core all as specified and directed.
Supply and fixing in replacement PVC insulated, PVC sheathed, multistranded copper conductor cable 2.5 Sqmm size, six core all as specified and directed..
Supply and fixing in replacement thermoplastic outdoor cable junction box hinged/screwed door type of size 200x160x 98 mm for 3 Phase and Nutral incoming cable, 3 Phase and Nutral outgoing cable with terminals and single Phase & Nutral connection for light fitting, 4 pole, 415 volt and one MCB SP 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision metric knockouts for cable entry through gland suitable for 16sq mm to 25sq mm cable as required at site complete all as specified & directed.
Painting to RCC pole with two coat of synthetic enemel paint in black & white strip 30 Cm wide each upto 1.5 mtr high from coping the pole all as directed by Engr-in charge
Dismantling of LT PCC pole 9 Mtr long of any discription including coping, foundation etc all as specified and directed.
Supply and errecting prestressed concrete pole 9.0 mtrs long,102x 172 mm at top and 102 mm x 279 mm at bottom class 10 all as specified and as directed by Engr in Charge.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces all as specified & directed.
All As per Item No here in before but PCC 1:3:6 type B-1 using 20 mm graded stone agg as in for mass filling
All As per Item No 50 here in before but PCC 1:2:4 type C1using 20 mm graded stone agg for copping
Supply and fixing in replacement micro prismatic reftective sheet, minimum 50 mm wide, with adhesive base for dirtectly fixing on HT/LT steel tubular/PCC pole without nail or any other fixing material at suitable height, in Red/White/Yellow colour complete all as directed.
Material and Labour in replacement straight through joint heats shinkable suitable for upto 70 sqmm LT 4.0 core 1100 volts XLPE cable type complete all as specified and directed.
Supply and Fixing inreplacement of aluminium thimble of size for cable10 to 70 sqmm all as specified and directed.
Material and labour for preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed.
Excavationes and relaying cables loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 1100 volts grade heavy duty cabel PVC insulated aluminium conductor , served with inner sheating of PVC tape and overall PVC sheated in service connection suspendede twin core cable flat or circular size 4 Sqmm all as sp and directed.
M&L fabricating and fixing in replacement of cross arms (any type) supports, bracting, stiffness etc made out of MS channel, angle iron, flat iron of any size including drilling of holes, making clamps, eye hooks, nuts, bolts and washers etc, welding if required including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil and connecting to earth up to 6 meter length complete all as shown in electrical plate no 5 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Supply and fix in replacement Timelite distribution boards of Timelite 40 Amps 3 pole 230 Volt astronomical time switch for out door use, weather and vermin proof duly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheet with locking arrangement comprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day,suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete - 1set
Supply and fix in replacement Timelite distribution boards of Timelite 32 Amps 3 pole 230 Volt astronomical time switch for out door use, weather and vermin proof duly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheet with locking arrangement comprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day,suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete,
Supply and fixing inreplacement street light mounting bracket made out of GI pipe 40 mm dia light Grade not less than with 1.5 (90cmx60cm) mtr long in any shape including clamps, nuts, bolts, washers etc and painting with aluminium paint,all as direced by Engr in Charge
Supply and fixing in replacement of fwg accessories in timer panels:-
MCB 40 Amps , 4 pole , 415 volts, 10 KA all as specified and directed.
Power contractor 3 pole, 415 volts, 40 Amps , C1 Series of current rated 40 Amps all as specified and directed.
Digital time switch programmable every 1 minutes with back up of 6 years, 28 memory locations , current capacity 16 A weekly program, with 1 changover (1 CO), total 28 programe.
(iv) Contactor coil of 32 amps / 40 amps , 415 Volts all as specified and directed.
Supply only in replacement of LED type street light Drivers of Operating Voltage 140-270 Volts, PF (0.95)LED driver current > 700 mA, suitable for existing size and make to functional the fitting LED complete all as specified and directed the following capacities.
LED Street Drivers light of 300 Watts .
LED Street Drivers light of 120 Watts .
LED Street Drivers light of 90 Watts .
LED Street Drivers light of 60 Watts .
LED Street Drivers light of 45Watts .
Material and labour for ACSR conductor any size drawn straight horizontal on LT over head lines on existing poles including binding with insulators weight of conductor shall be measured straight horizontal distance between centre of two adjacent LT poles and calculating weight of conductor of size length by adding 3% extra for sag jointing jumpers etc complete all as specified and directed.
S & F in replacement of MCCB Capacity 25 KA 3 pole 100 Amps with preader and aluminium lugs all as specified and directed.
S & F in replacement of MCCB Capacity 25 KA 4 pole 200 Amps with preader and aluminium lugs all as specified and directed.
Supply & fixing in replacement shackle/Pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers and nut 75 mm height, 90 mm dia for 1100 volts grade, including removal of existing insulators complete all as specified and directed.
Supply and fixing in replacement Metal Halide lamp 1000 watt, single ended, tubular type as existing shape and size complete all as specified and directed.
Supply and fixing in replacement Open Construction copper ballast (Choke) suitable for 1000 watt HPSV/MH light fitting complete all as specified and directed.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management, IP 66,Operating Voltage 140-270 Volts, PF (0.95), with Assemetric Lens Type-,Luminous Flux >5000Lm, Efficacy of LED > 130 Lm/W, inbuilt Surge Voltage Protection of luminaires 80 watt LED 5500 to 6500K complete fitting.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management, IP 66,Operating Voltage 140-270 Volts, PF (0.95), with Assemetric Lens Type-,Luminous Flux >5000Lm, Efficacy of LED > 130 Lm/W, inbuilt Surge Voltage Protection of luminaires 60 watt LED 5500 to 6500K complete fitting.
Supply and fixing in replacement LED type street light fitting pressure die cast aluminium housing(Heat sink)for effective thermal management, IP 66,Operating Voltage 140-270 Volts, PF (0.95), with Assemetric Lens Type-,Luminous Flux >5000Lm, Efficacy of LED > 130 Lm/W, inbuilt Surge Voltage Protection of luminaires 45 watt LED 5500 to 6500K complete fitting.
Supply & Fix in replacement flood Light Luminaire 300 watt with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate,powder coated in IP 66 life of 50000 hrs.Incliding protection of O/C,S/C,O/V, over temperature and lightning protection inbuilt complete.
Supply & Fix in replacement flood Light Luminaire 120 watt with .high power LED cool white, supply voltage 220/240/50 Hz, light engine driver base.pole adapter,pressure die cast polycarbonate,powder coated in IP 66 life of 50000 hrs.Incliding protection of O/C,S/C,O/V, over temperature and lightning protection inbuilt complete.
Supply & Fix in replacement integral post top lanterns complete with black ABC plastic spigot,spun aluminium funnel shape with clear cover light opening on canopy with baffles and accessories wit 10watt LED lamp complete all as specied and directed.
Supply and erection inreplacement, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate finial taper plug, bolt , nut and screwed type 410 SP 31( 9.00 mtrs long) single swan neck including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed by Engineer in charge. Note : PCC, Earth work and MS work as cross arms clamps etc will be measured and paid separately.
HARPAL ENGINEERS AND BUILDERS
M/s Vijay Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .