Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹14.0 L+₹3.1 L (28.5%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹16.9 L+₹6.0 L (55.6%)Rejected-AOC B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | L3 | Rejected-AOC Rejected being L3 | |
| 4 | Rejected-Technical BIMAL SINHA SARANI HAKIMPARA SILIGURI SILIGURI HAKIMPARA DARJEELING WEST BENGAL 734001 | JALPAIGURI | WEST BENGAL | 734001 | - | Rejected-Technical Eligibility documents not submitted | |
| 5 | Rejected-Technical 5 259 VIKAS NAGAR LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | - | Rejected-Technical Eligibility documents not submitted |
Tender Value
Refer Docs
EMD Value
₹35,600
Closing Date
1 Sept 2022, 6:00 pmClosed
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
CONSULTANCY INCLUDING PREPERATION OF DPR FOR CONSTRUCTION OF SEWAGE TREATMENT PLANT (STP) WITH ALLIED SERVICES AT DABATHWA UNDER GE (P) NO 2 MEERUT
2022_MES_536919_1
94029/MRT/2022-23/E8
Open Tender
Civil Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (P) No 2 Meerut
₹35,600
Yes
20 Sept 2022
9 Jul 2022
3 Sept 2022
9 Jul 2022
1 Sept 2022
18 Aug 2022
Amount
Provn of consultancy services for preparation of Detailed project report (DPR) and supervision for specified period during execution of main project contracted on the basis of approved DPR as per the scope contained in tender documents which includes complete sewage systems located in area of Dabathwa Military Station for proper disposal of sewage including working out quantities of sewage treatment plant, design and drawing and system to use the treated water for gardening etc. (Total Catchment area is appx 165 acre and population of area is appx 1000 Nos, total length of sewer line is appx 8 Km and tentative capacity of STPs is 3x100KLD. However, these data can have minor variations based on ground position design requirements and quoted rates deemed to include such minor variations)
The main requirements are briefly given below which shall be read in conjuction with the entire tender documents :- (a) Preliminary field data collection and contour survey at grid 30mx30m (b) Final detailed survey of proposed network of sewer line. (c) Preparation of master plan of localities showing GL/IL. (d) L-section of sewage generation. (e) Calcualtion of sewerage generation. Design the layout plan and size of pipeline. Complete designing of capacity, load calculation of various E/M items/equipments desired in the scheme. (f) Process of sewage treatment and method of treatment.
(p) Provide precast RCC pillar of size 250 mm x 250 x 750 mm duly reinforced with 04 nos ,10 mm dia TMT bar vertical and 8 mm dia stirrups @150mm C/C. Top duly finished with extra cement and bench mark engraved with refernce . Bench mark shall be finished with two coat of synthetic enamel paint for future reference (Bench Mark shall not be less than 15 Nos at location decided by GE).
Conducting necessary site visits minimum 4 times in a year and rendring clarifications as desired by the client.
NOTE:- Scope defined above shall be read in conjunction in other parts of tender documents covering detailed requirements and scope.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .