Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAdmitted-Finance PULGAON | ₹27.6 L | L1 | Admitted-Finance |
| 2 | L2₹30.6 LAdmitted-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | ₹30.6 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | metro electrical services L2 | M/S Maa Durga Constructions,Pulgaon L1 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive, periodical preventive maintenance, repair and servicing of 3X50 TR Central AC Plant Located at P-5 FSD ,Voltas Model No:CWCDR0500MNT (01 x 50 TR running and 01 x 50 TR standby) comprising the installed machineries and accessories mainly semi hermetically sealed reciprocating compressors (01 x 50 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | 3 | Each Job | 20,000 ₹60,000 | 9,000 ₹27,000 |
| 2.00 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-104 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | 3 | Each Job | 20,000 ₹60,000 | 9,000 ₹27,000 |
| 3.00 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC2S-026AR2 ( 02X 25 TR running and 01 X 25 TR Standby) installed at P-105 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (02 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | 3 | Each Job | 20,000 ₹60,000 | 9,000 ₹27,000 |
| 4.00 | Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-106 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed.
Note:- For BOQ Item No:1 to 4
A. Accessories such as expansion valve, solenoid valve, liquid line valve, filter dryer, sensors, Microprocessor controller, MPVD relay, µMPD(M3PD) relay, copper pipe etc as given separately shall be measured and paid separately etc. B. Labour charges for taking down defective items i.e. pansion valve, solenoid valve, filter dyer and all connected accessories to machine from the unit and making connection/jointing suction/discharge pipe complete deemed to be included in the quotated rate.
C. Gas and gas charging shall be measured and paid separately. D. Carry out preventive aintenance as per the standard practice in every month. E. This item include the cost of visiting the technician from authorised service dealer of blue star to check all parameters for smooth functioning of plant and will submit inspection report every month to Engr-in-Charge. F. Checking the system for any gas leaks and rectification of leaks if found. G. Taking set of readings and evaluating to ensure satisfactory performance of the plant. H. Checking the Central chiller plant control system for operation and djusting the settings. I. Checking of condenser unit and its accessories every month and take the reading of WT and LWT in hot and cold side and set CR at prescribed value. J. Checking the ctioning of scroll/Semi hermetic reciprocating compressor every month and its accessories. K. Checking of Evoprator unit (Chiller unit) and its accessories every month and take the reading of EWT and LWT in hot and cold side and set CR at prescribed value. L. Replacement of refrigerant gas as a result of fare wear and tear.cost of refrigerant gas will be measured and paid separately as supply only. M. Periodical checking of compressor oil and changing if found necessary (rate of changing of compressor oil deemed to be included in quotated rate). N. Checking of the central chiller plant control panel for its proper functioning and replacement of unserviceable accossaries connected to the control panel like fuse,wiring and other minor items are deemed to be included in quotated rate. O. AMC should be carried out within 03 day from the date of receipt by the contractor .Any delay beyound 03 day shall be compensated through panel recovery @ 1000 per day. | 3 | Each Job | 20,000 ₹60,000 | 9,000 ₹27,000 |
| 5.00 | Supply only refringent gas R-134A/R-22 for AC plant by contractors cylinder | 120 | Kg | 2,000 ₹2.4 L | 1,411 ₹1.7 L |
| 6.00 | Supply only refringent gas R-407C for AC plant by Contractor cylinder | 180 | Kg | 1,500 ₹2.7 L | 1,201 ₹2.2 L |
| 7.00 | Supply only LP/HP cutout suitable for existing AC plant . | 1 | Each | 400 ₹400 | 2,000 ₹2,000 |
| 8.00 | Supply only safety/failure switch Suitable for existing AC plant. | 1 | Each | 1,500 ₹1,500 | 2,500 ₹2,500 |
| 9.00 | Supply only solenoid valve Suitable for existing AC plant. | 1 | Each | 700 ₹700 | 3,500 ₹3,500 |
| 10.00 | Supply only V belt for blower fan motor/Compressor as per sample | 14 | Each | 300 ₹4,200 | 1,151 ₹16,114 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 May 2026, 6:00 pmClosed
CWE Nagpur
Commander Works Engineer Bldg No. P-9, Sitabuldi Fort, Nagpur - 440 001 Pin-900419, C/o 56 APO
REPAIRS TO CENTRAL AC PLANTS AND OTHER CONNECTED MISC WORK UNDER GE PULGAON
2026_MES_759558_1
86593/E8
Open Tender
Electrical and Maintenance Works
270 days
GE Pulgaon
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
₹70,000
Yes
19 May 2026
8 Apr 2026
13 May 2026
8 Apr 2026
11 May 2026
22 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Comprehensive, periodical preventive maintenance, repair and servicing of 3X50 TR Central AC Plant Located at P-5 FSD ,Voltas Model No:CWCDR0500MNT (01 x 50 TR running and 01 x 50 TR standby) comprising the installed machineries and accessories mainly semi hermetically sealed reciprocating compressors (01 x 50 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | - | Each Job | - | - | |
Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-104 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | - | Each Job | - | - | |
Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC2S-026AR2 ( 02X 25 TR running and 01 X 25 TR Standby) installed at P-105 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (02 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed. | - | Each Job | - | - | |
Comprehensive, periodical preventive maintenance, repair and servicing of 3 X 37.5 TR Central AC Plant BLUE STAR Model No:XWC3S-039AR2 ( 02X 37.5 TR running and 01 X 37.5 TR Standby) installed at P-106 B Sub Depot at CAD Depot comprising the installed machineries and accessories mainly hermetically sealed scroll compressors (03 x 12.5 TR in each unit),shell & tube type condensing unit and insulated chiller Complete by authorised service dealer of manufacturer/company of AC Plant as mentioned Complete all as specified and directed.
Note:- For BOQ Item No:1 to 4
A. Accessories such as expansion valve, solenoid valve, liquid line valve, filter dryer, sensors, Microprocessor controller, MPVD relay, µMPD(M3PD) relay, copper pipe etc as given separately shall be measured and paid separately etc. B. Labour charges for taking down defective items i.e. pansion valve, solenoid valve, filter dyer and all connected accessories to machine from the unit and making connection/jointing suction/discharge pipe complete deemed to be included in the quotated rate.
C. Gas and gas charging shall be measured and paid separately. D. Carry out preventive aintenance as per the standard practice in every month. E. This item include the cost of visiting the technician from authorised service dealer of blue star to check all parameters for smooth functioning of plant and will submit inspection report every month to Engr-in-Charge. F. Checking the system for any gas leaks and rectification of leaks if found. G. Taking set of readings and evaluating to ensure satisfactory performance of the plant. H. Checking the Central chiller plant control system for operation and djusting the settings. I. Checking of condenser unit and its accessories every month and take the reading of WT and LWT in hot and cold side and set CR at prescribed value. J. Checking the ctioning of scroll/Semi hermetic reciprocating compressor every month and its accessories. K. Checking of Evoprator unit (Chiller unit) and its accessories every month and take the reading of EWT and LWT in hot and cold side and set CR at prescribed value. L. Replacement of refrigerant gas as a result of fare wear and tear.cost of refrigerant gas will be measured and paid separately as supply only. M. Periodical checking of compressor oil and changing if found necessary (rate of changing of compressor oil deemed to be included in quotated rate). N. Checking of the central chiller plant control panel for its proper functioning and replacement of unserviceable accossaries connected to the control panel like fuse,wiring and other minor items are deemed to be included in quotated rate. O. AMC should be carried out within 03 day from the date of receipt by the contractor .Any delay beyound 03 day shall be compensated through panel recovery @ 1000 per day. | - | Each Job | - | - | |
Supply only refringent gas R-134A/R-22 for AC plant by contractors cylinder | - | Kg | - | - | |
Supply only refringent gas R-407C for AC plant by Contractor cylinder | - | Kg | - | - | |
Supply only LP/HP cutout suitable for existing AC plant . | - | Each | - | - | |
Supply only safety/failure switch Suitable for existing AC plant. | - | Each | - | - | |
Supply only solenoid valve Suitable for existing AC plant. | - | Each | - | - | |
Supply only V belt for blower fan motor/Compressor as per sample | - | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
tender93.pdf
Tender Documents • 0.84 MB
BOQ_850769.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid