Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Admitted-Finance |
| 4 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹8,700
Closing Date
15 Mar 2025, 2:00 pmClosed
EXECUTIVE ENGINEER (EM) M-10
GREATER KAILASH, PART-I, NEW DELHI
Improvement of lighting system at Sec-07 ZRO office New Building under R. K Puram AC-44.
2025_DJB_269338_4
NIT No. 33/EE(EM)M-10/(24-25)
Open Tender
Electrical Work/ Equipment
Works
15 days
EXECUTIVE ENGINEER (EM) M-10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹8,700
Yes
2 May 2025
7 Mar 2025
15 Mar 2025
7 Mar 2025
15 Mar 2025
7 Mar 2025
S/o 20W LED Batten light. DJB SOR2022 item code-19.1.2
S/o 450 mm size Exhaust Fan. DJB SOR2022 item code-20.2.3
S/o 1200 mm size Ceiling Fan. DJB SOR2022 item code-20.1.2
Wiring for light point / fan point/ exhaust fan / call bell point / with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR (E&M)20221.10.3 Group C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR (E&M)20221.14.2
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wireDSR (E&M)20221.14.3
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR (E&M)20221.13
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switch DSR (E&M)2022 1.24.1 Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet DSR (E&M)2022 1.24.4
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet DSR (E&M)2022 1.24.4
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch DSR (E&M)2022 1.24.3
Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outletDSR (E&M)2022 1.24.5
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR (E&M)2022 1.25
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR (E&M)2022 1.44
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 08 way, Double doorDSR (E&M)2022 2.3.2
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole DSR (E&M)2022 2.10.1
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole DSR (E&M)20222.10.3
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required DSR (E&M)2022.5.2
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required DSR (E&M)2022.5.16
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .