Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹38.9 L+₹1.4 L (3.71%)Rejected-AOC SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹39.7 L+₹2.2 L (5.81%)Rejected-AOC 108 JAYARAM REDDY GARDEN DODDA BANSWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹42.9 L+₹5.4 L (14.5%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST |
Tender Value
₹40.8 L
EMD Value
₹81,520
Closing Date
13 Dec 2024, 6:00 pmClosed
Col AK Trpipathi CWE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPECIAL REPAIRS TO BLOCK NO P-4 JCOS/OR MD ACCN AT RAMCHANDRA LINE OF 4/8 GR UNDER GE (NORTH) BANGALORE
2024_MES_681930_1
86319/E8
Open Tender
Civil Works
Item Rate
180 days
HQ CWE ARMY BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (NORTH) BANGALORE
₹81,520
Yes
24 Jan 2025
30 Oct 2024
20 Dec 2024
30 Oct 2024
13 Dec 2024
29 Nov 2024
30 Oct 2024 - 6 Nov 2024
Amount
Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for complete etc all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exceeding 1.5 sqm each including making good disturbed surface to match with adjoining surfaces etc complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4.0 Sqm each including making good disturbed surface to match with adjoining surfacesetc complete all as specified and as directed
Taking down shutter of any description area exc 1.00 Sqm but not exc 2.00 sqm each etc complete all as specified and as directed
Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed
Taking down shutter from frames of any description area exc 1.00 sqm & not exc 2.00 sqm each and refixng in same opening after easing / minor adjustment / repairs / side cutting / repairs etc complete all as specified and as directed (Notes : Glass, wire cloth, butt hinges, Handle, tower bolt, sliding door bolt or any other mtrl reqd to fixing the door shutter, shall be measured and paid Sepeartely under relevant of this schedule )
Taking down Handle / Sliding door bolt/ Hasp & Staple/ Tower Bolt / piano hinges etc of any size and any description etc complete all as specified and as directed
M&L for Cement concrete (1:4:8) type D- 2 using 40mm graded crushed stone aggregate as in 75 mm thick sub base of flooing complete all as specified and as directed
M&L for Cement concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregates as in 25 mm thick sub base of flooring complete all as specified and as directed
M&L for PCC (1:3:6), type C-1, using 20 mm graded crushed stone aggregates as in 75 mm thick plinth protection finished even and smooth without using extra cement including joints filling with sealing compound Grade "A" complete all as specified and directed.
M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over & including 15 mm thick screed bed in cement mortar 1:6 including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M & L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting / dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over & including 10 mm thick backing coat in cement mortar (1:3) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M & L for Non - skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar (1:6) including dismantling floor, hearth etc complete all as specified and as directed
S&F for Cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick exterior grade, coloured glossy finish rubber pressed, set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles over and including 15mm thick Screed bed or bedding layer of cement mortar (1:6) including demolition of stone slab (Laid bedded and pointed in any mortar) etc complete all as specified and as directed
M&L Glazed ceramic coloured tiles 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match over & including backing coat 10 mm thick in cement mortar (1:3) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M&L for 18 to 20mm thick Green Marble (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding the edges half round and polishing over& including 15mm thick screed bed in cement mortar (1:6) including dismantling floor, hearth or wall tiling etc complete all as specified and as directed
M&L Pre-cast Cement concrete (1:3:6) type C-1 using 20 mm graded crushed stone aggregates as in solid block masonary with solid blocks, exceeding 10 cm in width and setting in cement mortar (1:6) including demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
M&L for Walling of Stone Masonry squared rubble, uncoursed well bonded, bedded and solidly hearted, built in cement mortar (1:6) etc including demolition of brick Work / Stone Masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
M&L for Key pointing to random or polygonal rubble, uncoursed or brought upto course in cement mortar (1:4) etc complete all as specified and as directed
M&L for Key pointing to random or polygonal rubble, uncoursed or brought upto course in CM (1:4) including raking out joints/ pointing to masonry in single detached joints for flashing, etc complete all as specified and as directed
M&L for Pre-cast cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM (1:6) etc incl demolition of existing RCC Slab of any description and in any position etc complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
M&L for rendering 5 mm thick in cement mortar (1:3) on fair faces of ceiling concrete surface finished even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface finsihed even and smooth without using extra cement etc complete all as specified and as directed
M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface and 5 mm thick in CM (1:4) (total 15mm thick plaster) mixed with water proofing compound as per manufacture instruction finsihed even and smooth without using extra cement etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M&L for providing water proofing treatment to sunken portion of WCs, bathroom etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating including taking down existing treatment with PCC as in sunken protion of WC and removing to a distance exceeding 1.00KM but not exceeding 5.00KM. The following procedures to be adopted during the execution of work :- (i) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. The layer will be allowed to air cure for 4 hours. (ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iii) 20mm thick screed in cement mortar 1:3 mixed with liquid water proofing compound. (iv) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. Notes: (a) Girth of sunken floor shall be considered for payment purpose. (b) Depth of sunken slab shall be exceeding 30cm but not exceeding 60cm
M&L providing cement concrete (1:2:4) type B0 using 12.50mm graded crushed stone aggregate in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including necessary formwork weathering, slightly rounded or chamfered angles and throating as specified & as directed
M&L for screed bed 10 mm thick in CM (1:3) mixed with water proofing compound to receive roof tratement etc complete all as specified and as directed Notes: WPC shall be measured and paid seperately under relevant item
M&L for water proofing treatment to RCC roof surfaces all as specified and directed as per following :- (i) Removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth (ii) Applying compatible primer @ 0.30 Litr/Sqm (iii) Laying APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.00kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished with torch applications of membrane with 100mm side overlap and 150mm end lap as per manufacturer's instructions (iv) Applying a coat of aluminum paint on top @ 0.10 litre/sqm complete Note : Quoted rate is deemed to be included the demolition of any type of roof treatment including roof tiles including removing debris to a distance exceeding 1.00KM but not exceeding 5.00KM. Nothing extra shall be admisible on this account
Supply only Liquid water proofing compound , ISI marked complete all as specified and as directed.
S & F Factory made 1.25 mm thick pressed steel frame of size 125 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
S&F Factory made 1.25 mm thick pressed steel frame of size 105 X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
M&L for cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in hold fast and filling of pressed steel chowkat including necessary form work etc complete all as specified and as directed
M&L Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe -E-165 etc complete all as specified and as directed
S&F Flush shutter 35mm thick solid core construction with decorative choice lamination both sides of shutter, kiln seasoned and chemically pressure treated complete all as specified and as directed
S & F in repairs Prelaminated particle board 18/19MM thick, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, fixed in kitchen Cabinet or cupboards all as specified & directed
M&L for Plain fillets square, rectangular or triangular in section not exceeding 3 sqcm cross section area clean sawn, secured with nails or brads of second class hard wood fixed to cupboard shutter all as specified and directed.
S & F in repairs cupboard knobs 40 mm dia Brass polished fixed with nut, screw and washer complete all as specified and as directed.
S & F in repairs Continuous (piano) hinges, 30 mm width of flap (when open) mild steel, bright finish or electro galvanised etc complete all as specified and as directed
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplyng & fixing in opening complete all as specified and as directed
S & F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed.
S&F Aluminium frame for doors, windows ventilators duly powder Coated (minimum thickness of powder coating 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed
S & F aluminium window and ventilator shutters duly Powder Coated (minimum thickness of powder coating 50 micron) fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as specified etc. complete shall as specified and as directed
S&F Sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beading to wooden frame or steel frame in squares not exceeding 0.50 sqm in each pane complete all as specified and as directed
S&F Figured glass sheet 4mm thick, pin head type and glazing with oil putty in squares in not exceeding 0.5 sq.m in each pane etcc omplete all as specified and as directed
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staple etc complete all as secified and as directed
S&F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed
S&F aluminium alloy, anodised sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed
S & F Butt hinges 100 mm size medium weight, stainless steel and fixed etc complete all as specified and as directed
S&F Aluminium handle 150 mm size, cast type, anodised etc complete all as specified and as directed
S&F Floor door stopper 150 mm overall length, aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor etc complete all as specified and as directed
S&F Aluminium Hasp and staple 100 mm size, safety type, mild steel hinge pin including bolt to hinge plate and fixed with screws etc complete all as specified and as directed
S&F in repair sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mmetc complete all as specified and as directed
S&F in repairs Vitreous china wash down water closet Pedestal pattern (EWC) Ivory colour with normal closing seat cover with S Trap including connection to out going pipe, & seat cover and flushing pipe complete all as specified and as directed
S & F vitreous china wash basin white flat back size 550x400mm excluding chain and plug and porcelain stopper but including GI bracket, waste fittings brass chromium plated, PVC waste pipe 75 cm long with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed fixed in repairs
S&F in repairs PVC duo flushing cisrern valveless with flushing out valve low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets & connection to pipe etc including PVC connection 15mm dia 450 mm long with PTMT nuts complete all as specified and as directed
S & F in repair Bib tap 15mm dia bore, brass chromium plated long body with CP flange all as specified and as directed.
S&F in repairs Wall mixer brass chromium plated for mixing hot and cold water screwed down for 15mm dia iron pipe and fixed complete all as specified and directed
S & F in repairs Centre hole Basin mixture without Pop Up, brass chromium plated fixed to 15 mm dia bore pipes all as specified and as directed.
S & F in repairs Sink mixture with regular spout, brass chromium plated, wall mounted fixed to 15 mm dia pipe all as specified and as directed.
S & F in repairs Angle cock cast copper alloy chromium plated screwed down high pressure with capstan head handle screwed both ends or for unions etc fixed to 15mm dia bore pipe all as specified and as directed.
S & F in repairs Unbreakable (Square) wall mounted shelf 500mmx150mm with 2Nos of SS rail etc complete all as specified and directed
S&F in repairs Unbreakable corner shelf 8" semi circular with 2Nos of SS rail complete all as specified and directed
S&F in repairs Soap dish chromium plated brass with glass cup all as per fixed on wall as per manufacturers instruction.
S&F in repairs 100mm (4") overhead shower ABS with Arm (225mm) brass chromium plated & flange including fixing to steel pipe or union complete all as specified and as directed.
S & F in repairs Looking Mirror 600x450 x 5-6mm thick with bevelled edge and fixed with 4 Nos of stud complete all as specified and directed
S&F in repairs PVC Mirror cabinet of size 400x500 mm with suitable nos of shelfs complete all as specified and as directed.
S & F in repairs stainless steel plate rack made of 0.63mm thick sheet, size 800mm x 600mm complete all as specified and as directed
S&F in repairs Towel rack, Brass chromium plated glossy finish 450 mm long 250mm width with 4nos of 8mm S S round bars with sufficient nos of hooks complete all as specified and directed
S & F in repairs Towel rail stainless steel glossy finish 450mm long complete all as specified and as directed.
S&F in repairs Towel ring Brass chromium plated 200mm dia glossy finish complete all as specified and directed
S & F CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors, concealed type, including taking down existing GI/CPVC pipe line etc complete all as specified. Notes : Quoted rate deemed to be included for cutting grooves for concealing of pipes or cutting holes into stone maosonary wall and making good.
S & F CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors including taking down existing GI/CPVC pipe line etc complete all as specified.
S&F in repairs rotational moulded polythene water storage tank (cylindrical vertical with closed top) 1000 ltrs triple layered, hoisted and fixed in position all as specified in SSR part I including ball float valves 25 mm dia of bore high pressure of PTMT with epoxy coated aluminium rod & high density plastic etc complete all as specified and directed
Disconnecting existing 1000 litre tanks, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position (Cleaning reparing etc measured sepeartly ) including 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic etc complete all as specified and directed
S & F Gun metal, globe or gate valve 25 mm dia with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
S&F in repairs PVC (SWR) multi floor trap with grating 75 mm dia bore outlet including jointing with solvent cement etc complete all as specified and as directed
S&F PVC, SWR pipes 110 mm dia single socketed in any length with rubber ring joint laid in trenches etc incl dismantling of existing pipe and fittings etc complete all as specified and directed
S&F PVC SWR pipes 110 mm dia, single socketed in any length with rubber ring joint fixed to walls etc including dismantling of existing pipe and fittings etc complete all as specified and directed
S&F PVC SWR pipes 75 mm dia single socketed in any length with rubber ring joint laid in trenches or in floors etc incl dismantling of existing pipe line and fittings etc complete all as specified and directed
S&F PVC SWR pipes 75 mm dia single socketed in any length with rubber ring joint fixed to walls etc incl dismantling of existing pipe line and fittings etc complete all as specified and directed
S&F PVC bends (any radius) of 110mm dia with access door etc complete all as specified and as directed
S&F PVC (SWR) branch pieces 110mm dia bore, double (double Y) equal or unequal etc complete all as specified and as directed
S&F PVC vent cowls of 110mm dia etc complete all as specified and as directed
S&F PVC bends (any radius) of 75mm dia with access door etc complete all as specified and as directed
S&F PVC (SWR) branch pieces, 75 mm dia bore single (single Y) equal or unequal etc complete all as specified and as directed
Complete removal exising treatment (External/Internal wall) by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface including rubbing and washing etc complete all as specified and as directed
M&L for preparation of wall surface with sand paper etc and applying 1mm thick wall care putty finished to smooth surface etc complete all as specified and as directed
M&L for preparing newely plastered ceiling surface and applying two coats distemper oil emulsion, white or tinted over a coat of self primer complete all as specified and as directed
M&L for preparing Old ceiling surface and applying two coats distemper oil emulsion, white or tinted over a coat of self primer etc complete all as specified and as directed
M&L for Preparing new plastered wall suface and applying two coats distemper acrylic emulsion, white or tinted over a coat of self primer complete all as specified and as directed
M&L for Preparing Old plastered suface of walls and applying two coats distemper acrylic emulsion, white or tinted over a coat of self primer complete all as specified and as directed
M&L for preparation of new or old plastered surface of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, diirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. etc complete all as specified and as directed
M & L for preparation of old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for Preparation of new or previously un-treated steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
S&F in repairs stainless steel decorative curtain rod of 25 mm bore including fancy finale caps cap (02 nos in each curtain rod) etc complete all as specified and as directed
S&F in repair Brass Chromium Plated designer Bracket for curtain rod of dia 25 mm dia made out of SS Flat not less than 20 mm wide 1.50 mm thick and overall length not less than 160 mm fixed with screws min 2 Nos with Rawl Plug of size not less than 50 mm long etc complete all as specified and as directed
S&F in repairs Bib Cock 2 way, double handle, brass chromium plated with CP flange fixed to 15mm dia pipe all as specified and as directed.
S&F in repairs Health faucet, 15mm dia bore brass body chromium plated with 1mtr SS braided tube & wall hook complete all as specified and as directed
Removing building materials etc. to a distance of exc 900 mtr but not exc 1.00 Km, including loading, unloading and stacking at the destination etc complete all as specified and as directed (Note : 1 metric tonne=1 load, 1cum=1735kg)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed.
M&L Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type type run on walls/ ceiling including mild steel terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for following :-
One light / fan point controlled by one switch and - ditto-
One light point controlled by two way switch and - ditto-
One 3 pin socket out let 5 Amps on independent board and - ditto-
One 3 pin socket out let 5 Amps on same board and - ditto-
One Bell / Buzzer Point controlled by bell push and - ditto-
M&L for Point Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit with accessories surface type on walls/ ceiling including mild steel terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for socket outlet 15Amps all as specified and as directed.
Note for Item No 119 & 120 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Quoted rate is deemed to be included following:- (a) Terminal boxes (b) circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
S&F LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
S&F LED batten suitable for indoor applications 10 Watts, 2 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed.
S&F in repair Angle holder PVC / polycarbonate type including LED Bulb of 15 watt all as specified and as directed
S&F in replacement switch piano flush type single pole, one way 5 Amps, 240 volts all as specified and directed.
S&F in replacement switch piano flush type single pole, two way 5 Amps 240 volts all as specified and directed.
S&Fin repair Ding Dong bell AC 230 volts single pole all as specified and directed.
S&F in repair of bell push flush type 5Amps all as specified and as directed .
S&F in repair Stepped type electronic fan regulator, flush Switch/socket type, 240volts all as specified and as directed
M&L for Taking down ,dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing on its original position complete all as specified and as directed.
S&F in replacement Switch socket combination 2 in 1 , 5 Amps flush type all as specified and as directed
S&F in replacement switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
S&F in replacement of MCB SPN 240 volts 32/40 Amps C curve complete all as specified and as directed
S&F in replacement of MCB single pole 240 volts 10/16/20/32 Amps C curve complete all as specified and as directed
S&F in replacement of MCB Distribution Board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S&F in replacement of MCB Distribution Board SPN 4 way, double door type, 240 volts with 200 Amps rated busbar all as specified and as directed.
S & F Electric water heater Storage type 25 Ltrs, BEE 5 star rated, steel body with copper inner tank and heating element upto 2 KW capacity, with all accessories such as safety valve, thermostat, NRV, steel wired pipe for hot/cold water connection for inlet and out let water etc.complete all as specified and directed at site .
S&F in replacement of MCB Distribution Board TPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in replacement of MCB TPN 63 Amps, 415 volts 10 KA, 'C' curve complete all as specified and as directed
M & L excavation in trenches in hard/dense soil not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exc 50m distance and deposited not exceeding 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable as per specification complete all as specified and as directed
S&L sub class 'B' burnt bricks old size for cable protection, laying as per specification complete as specified as directed
S&L XLPE insulated screened PVC bedded galvanised steel strip or wire armored,electric power cable (heavy duty) 4 Core 16 Sqmm cross sectional area, 1100 Volts grade with stranded aluminium conductor connected with suitable lugs including taking out the existing unserviceable cable complete as specified as directed
S&F in replacement of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
M&L for Sub main wiring with two runs of PVC insulated single core 6 Sqmm multistranded FRLS copper conductors along with 6 Sqmm single core multistranded copper conductor cable1100 volts grade as earth continuity conductor drawn through & including suitable size of PVC casing caping and taking out old / un-serviceable sub main wiring all as specified and as directed (Note : Three run of 6sqmm cable and one run of PVC casing & capping altogether measured as one unit)
M&L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cast RCC slab 40mm thick in cement concrete 1:2:4 type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways including funnel with watering pipe, protection pipe, wire mesh and lugs, test point complete including dismantling & removing existing earthing all as specified and as directed.
Supply and fixing LED bldg security light fitting 30 Watts with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittingscomplete all as specified and as directed.
S&F G I Bracket made out of GI tubing medium grade 25 mm bore, approx length 1.5 m including MS clamps made out of flat iron 25 x 6 mm, nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230Volts of size 300m sweep with, blades, and frame and louvers complete including necessary arrangement for installation all as specified and directed
M&L for core cutting in walls for installation of exhaust fan / fresh air fan and making good of disturbed wall surface to match with the existing surface all as specified and directed
S&F in replacement PVC Fresh air exhaust fan 200mm sweep 1200/1400 RPM with louver complete including necessary arrangement for installation all as specified and directed.
M & L PCC (1:5:10) type E-2 using 40mm graded crushed stone aggregate for filling in sunken slab or similar item all as specified and directed.
Aavani BUILDERS AND CONTRACTORS (BID ID -3177563)
Janatha Trading Corporation (BID ID -3188412)
J PUSHPALATHA ENGINEER AND CONTRACTOR (BID ID -3182434)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .