Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.1 LAccepted-AOC E MUTHILINGAPURAM VILLAGE SATTUR TALUK VIRUDHUNAGAR DISTRICT UNDER MADURAI DIVISIONAL OFFICE OF TAMIL NADU STATE OFFICE | VIRUDHUNAGAR | TAMIL NADU | 626001 | ₹62.1 L Quoted ₹52.6 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹52.7 L+₹9,630.30 (0.18%)Rejected-Finance 8TH FLOOR ROOM NO 8 I SARVAMANGALA HOUSE 5 DR RAJENDRA PRASAD SARANI BBD BAG KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | ₹52.7 L+₹9,630.30 (0.18%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹56.0 L+₹3.3 L (6.35%)Rejected-Finance | ₹56.0 L+₹3.3 L (6.35%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹70.6 L+₹18.0 L (34.2%)Rejected-Finance | ₹70.6 L+₹18.0 L (34.2%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹76.1 L+₹23.5 L (44.7%)Rejected-Finance | ₹76.1 L+₹23.5 L (44.7%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
Refer Docs
Closing Date
15 Apr 2026, 3:00 pmClosed
GM I/C (Mtls and Contracts)
INDIAN OIL CORPORATION LIMITED (MD) EASTERN REGION OFFICE MATERIALS AND CONTRACTS DEPTT., INDIAN OIL BHAWAN 2 GARIAHAT ROAD (SOUTH), DHAKURIA, KOLKATA-700068
Works Contract for Installation of Tanker Loading Facility at LBP Kolkata
2026_ERO_189542_1
ER-MnC/2026-27/LT/9
Limited
Mechanical Works
Works
120 days
Lube Blending Plant, Kolkata-P68 Karl Marx Sarani
As per tender document
2 documents required · 2 mandatory
Exempted
24 Apr 2026
8 Apr 2026
16 Apr 2026
8 Apr 2026
15 Apr 2026
8 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | LAYING & WELDING OF PRODUCT PIPELINE (ABOVE GROUND) IN ZONE- A
Laying and welding (3 runs minm.) Above Ground Pipelines from supplied MS pipes (pipes to be supplied anywhere within the depot and the contractor shall shift the same to the site of work at no extra cost with all leads and lifts) of the following sizes as described below, including cutting, bevelling and fixing the supplied specials such as elbows, bends, tees, reducers, etc complete and successful hydrotesting the pipeline at a pressure of 10.5 kg/cm2 for a minimum period of 4 Hrs.
The job includes Dye Penetration (DP) testing of pipeline joints as per approved QAP. Above ground pipeline to be laid on concrete pedestals (which is to be constructed as per the respective item of this schedule)/ pipe racks/ TLF shed/ pump house and manifolds and Painting the pipeline as per the specifications enclosed including the colour coding as per IOC specifications. Welding of pipeline should conform to Radiography quality. 10% of the joints shall be radiographed and the cost of the same will be paid separately as per respective item, etc. and as directed at site.
Note:
a. Any repairs to the defective welding shall be made good at no extra cost to IOCL. Re-radiography of repaired joint shall also be at contractor's cost.
b. The rates quoted also to include Painting and colour coding of pipelines as per the standards.
c. Painting Scheme : Application for External painting shall be carried out by means of AIRLESS SPRAY PAINTING SYSTEM only.
1. Surface Preparation : as per Sa 2½
2. Primer : P1- Inorganic Zinc Ethyl Silicate - Single Coat, DFT 65-75µ
3. Intermediate Coat : U1- Polyamide cured HB Epoxy MIO - 2 Coats , DFT 200-250µ (2 coats of 100-125µ)
4. Finish Coat : F1- Two Pack Aliphatic Acrylic Poly-Urethane (PU) - 2 Coats, DFT 50- 60µ (2 coats of 25-30µ).
Total Min DFT 315µ | - | - | - | - |
| 2 | LAYING & WELDING 350 mm dia pipe | - | MTR | - | - |
| 3 | LAYING & WELDING 250 mm dia pipe | - | MTR | - | - |
| 4 | LAYING & WELDING 200 mm dia pipe | - | MTR | - | - |
| 5 | LAYING & WELDING 100 mm dia pipe | - | MTR | - | - |
| 6 | Making flanged joints between flanges (WNRF/SORF/BLRF) including supplying and fixing 3 mm thick SW SS gaskets with graphite fillers, studs, nuts, bolts of approved make for the following sizes, as per IOCL specifications and site instructions. The flanged joint shall also include providing and fixing multistrand copper wire/flat for bonding of product pipelines including provision of lugs wherever required. | - | - | - | - |
| 7 | 350 mm dia | - | EA | - | - |
| 8 | 250 mm dia | - | EA | - | - |
| 9 | 200 mm dia | - | EA | - | - |
| 10 | 150 mm dia | - | EA | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
Part-B_Version-2.pdf
Tender Documents • 1.19 MB
Undertakings-and-Declarations-LT9.xls
Tender Documents • 0.36 MB
BOQ_199810.xls
BOQ • 0.44 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
TECHBID-LT9.pdf
Tender Documents • 0.74 MB
TechnicalSpecifications_Listofpreferredmakes_QAP.rar
Tender Documents • 15.04 MB
DRAWINGS.rar
Tender Documents • 0.28 MB
GCC_PPE_ISB_SAFETY_HOLIDAY_EVALUATION_OTHERS.rar
Tender Documents • 8.50 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .