REPAIR/ MAINT OF SOLAR WATER HEATER, WATER LEVEL INDICATORS ON OHR/ UG SUMP, HOOTER/ SIREN SYSTEM AND ALLIED WORKS AT AF STN JMR AND REPAIR OF OLD VINTAGE AMF PANEL AND WATCH TOWER SEARCH LIGHTS ALONGWITH CONNECTED WORKS AT RAMGARH UNDER GE(AF) JAISA
2026_MES_789027_1
8473/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender document
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹81,120
Yes
12 Sept 2026
12 Sept 2026
3 Oct 2026
12 Sept 2026
1 Oct 2026
26 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,Install,testing & commissioning in replacement factory made and tested AMF panel 160 KVA indoor type platform mounted suitable for 15 volts 3 Phase and neutral wire,50 Hz AC supply system having busbar with insulated sleeves aluminium busbar of 250 amps rating.The panel shall be dust & vermin proof protection class (IP-42) and made of 2.00 mm thick CRCA sheet suitable angle iron frame work made out of 50 x 50 x 6mm front opening type with proper ferrule & cable gland,internal wiring with PVC insulated multistranded copper conductor PVC wire of adequate size but less than 1.5 Sqmm complete.All sheet metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of siemen grey shade 7035 embedded ground with & including blocks of PCC 1:2: type B1 block size 30 x 30 x 30 cm complete all as specified and directed by Engr-in-Charge.
Make : Adiec/Schneider/Universal Switch Gear Control/Tricolite
The scope of work also comprising of the following : -
(a) Control MCB SP 6 Amp 230 Volt (b) Control MCB SP 16 Amp 230 Volt
(c) Battery charger 12/24 DC (d) LED Indicating light for main & DG
(e) LED Indicating light for main & Gen ON (f) LED Indicating light for Battery charger
(g) Digital voltmeter (0-500V) flush mounted 96 mm x 96 mm with selector switch
(h) Digital ammeter (0-250 Amps) flush mounted 96 mm x 96 mm with selector switch
(j) CT Coil 250/5A CL-1 (k) DC Voltmeter 15/30V analog type
(l) DC Ammeter 0-15 A analog type (m) Trickle/Boost switch & selector switch
(n) Auto/Manual Selector Switch (o) Start/Stop Push Buttton
(p) Hooter 12/24V DC (q) Auto main failure controller (AMF) with LCD display 96 x 96 mm (Model-DGC6D)
(r) Power Contactor 255 Amps Pole having coil voltage 220 V AC for DG Supply
(s) Power Contactor 255 Amps Pole having coil voltage 220 V AC for Main Supply
(t) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for main supply
(u) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for DG supply
(v) Over load relay 3-5 A (w) Control relay 12/2 V DC (x) Danger Notice Plate
(y) Enclosure of suitable size along with internal wiring & Buisbar chamber 250 Amp Strips Aluminium
Note : AMF Panel manufacturer should have following Government approved certificates :-
(a) Panel Should be according to IEC -61439.CPRI Certification degree of protection IP-54 (IS/IEC-6139 (part-I),2011 & (IS/IEC-6139 (part-II) 2011 (b) Temperature rise (IS/IEC-61439 (part-I),2011 & (IS/IEC-61439 (part-II) 2011.
(c ) CPRI short circuit IEC -61439 1 & 2 withstand strength should be 70 Karms for 1.0 sec with initial peak of 15kApk.
(d) CPRI Certification IEC -61439 1 & 2 ratted current for short circuit not less than 4000A with rated insulation voltage 660 V.
(e) ISO 9001 certified. | 1 | Each | - | - |
| 2 | Material and labour for Chemical earthing complete in replacement of conventional GI Strip earthing with copper earth plate 90x60cmx5mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to copper earth strip 50 x 6 mm by means of bolts nuts check nuts and washer ,returning & filling the pit with excavated soil mixing with charcoal 250 kg,Crystal salt 200 Kg,magnesium sulphate 100 Kg and vegetable soil all around the plate utpo 350 mm above from the top edge of plate and balancing portion filling withy excavated soil in layers not exceeding 25 mm thick,25 mm galvanized iron medium grade watering pipe upto top of plate 50 mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil,PCC 1:3:6 type C1 for chamber of internal size 300 mm x300 mm x 300 mm with 120mm thick wall and 700 mm x700 mm x700 mm thick,bed concrete,RCC 1:2:4,type B 1for Precast chamber cover 50mm thick,reinforced with welded steel fibre of XPM Jali (weight not less than 4.00 Kg/Sqm),funnel with mesh,complete all as specified and directed as per Engineer-in-charge.
Note :
(i) Upto 7.5 mtr length of pipe of 40 mm dia and copper strip shall be deemed to be included in the quoted rate.
(ii) Earth result after installation completely should be less than 1 ohm.
(iii) Black Soil to be arrange by contractor for mixing with charcoal, crystal salt , magnesium Sulphate & Vegetable oil and also for filling balance portion of unit in layers is deemed to be included in the quoted rate.
(iv) Transportation charges for arrangement of black soil is deemed to be included in the quoted rate.
(v) Tools and plants require for making requisite depth arrange by the contractor. charge of the same is included in the quoted rate. | 2 | Each Set | - | - |
| 3 | Supply install testing & commissioning in replacement of old conventional MH light with high intensity, long range- 1KM, multi functional, auto rotatable, 360 degree LED search light, 1x300 watt, narrow beam- 5 degree, LM6 housing with heat sink, round in shape, dia 430mm, operating voltage 90V- 300V AC 50hz, PF >0.95, THD <20%, CCT: 5500K-6000K, CRI >70, Optics used- PMMA/PC lens, LED efficacy >140 l/w, average lux level at 10meter >10,000 with circle of approx 1meter, toughened clear glass with silicaon gasket, driver efficiency >95%, over volt / under volt & short circuit protected, confirming to LM79, LM80, IK07, IP66, Lux level report & BIS. The search light will easy to installed on a unique rotating stand having such designed that the light could be auto rotate 360 degree continuously (overnight) in the horizontal alongwith vertical tilting by motor upto 45 degree & covered by weather proof die cast fiber box with provision of 4 nos. foundation hole for installation.At any place over roof of watch tower or inside watch tower as per direction of Engineer-in-Charge including fixing arrangement as per infrastructure instruction. A wall-mounted wired control panel (consist of MCB, V-meter, fuse, LED indicator and having buttons for speed controller (1-10 rpm), auto/ manual, rev./forw and up/down buttons) is supplied for safe operation.
Make: KALIN Model No.: MRSL-LRFLL-25PC30 or techno commercially equivalent as approved by GE.te :- All auto revolving search light to be covered with inclined SS canopy of size that covers the light fully with shed being 15inches above top of light (price deemed to be considered in quoted price) | 4 | Each | - | - |
| 4 | Attending complaints of no water supply in over head water storage tanks of Solar water heaters for any reason like, leakage in the inlet pipe, breakage of pipe line or any other reason , rectification of complaint including any petty repair required to restore the water supply for checking of existing items for contineous water supply including carrying out minor repairs such as tightening of loosen Tees, sockets, bends, nipples, unions required to make the item functional during 0900 hours to 1800 hours by deploying plumber alongwith helper including necessary T&P complete all as specified and directed.
Note :- (a) Replacement of electrical fitting/fixtures for supply & fixing shall be measured and paid for separately under respective items.
(b) Repairs in any one quarter/ one occupancy shall be considered as one complaint (one measuring unit) even if repair is involved in more than one items required for repair shall be measured and paid separetely.
(c) Number of complaint may varry day to day contractor shall quote their rates accordingly.
(d) In case of failure on the part of contractor for attending complaint as penalty shall be imposed and recovered in Rs. 200/- Each complaint as specified.
(e) Contractor shall ensure that the deployed electrician & helper with carry functional and live mobile phone connection while on duty and will be on contact with JE incharge/ Engineer-in-Charge.
(f) Contractor shall be responsible for collection of all ON line complaints and hand over the same JE E/M/AGE E/M and to date the states ON line after attending /complete of the Job. | 90 | Each | - | - |
| 5 | Servicing of Solar Water Heater including cleaning of main tank, Solar power module/ Solar Panel Reflectors including checking/ repairing leakage of inlet/ outlet pipes of Solar Water Heater complete all as specified and directed. | 18 | Each Job | - | - |
| 6 | Supply and fixing in replacement of Solar Panels or collectors suitable for Solar Water Heater Capcity 500 LPD including its installation with support of angle iron of minimum size 40x5mm, welding works, nuts, bolts etc with other material required to complete the work including testing after installation including taking down old unserviceable complete all as specified and directed.
Note : For Solar Water Heater Capcity 500 LPD - 04 Flat plate collector used.Replacement of each Flat plate collector shall be considered as each Job. | 3 | Each Job | - | - |
| 7 | Supply and fixing in replacement of Solar evacuated tube of 1.6mm borosilicate glass tube with any of size as mentioned (58 mm O.D & 1800 mm length/58 mm O.D & 2100 mm length/70 mm O.D & 2100 mm length/47mm O.D & 2100 mm length) of Solar Water Heater as per existing for Solar Water Heater Capcity 300/330 LPD including its installation with support of angle iron, welding works, nuts, bolts,washers etc with other material required to complete the work including testing after installation including taking down old unserviceable complete all as specified and directed.
Note : For Solar water heater of capcity 300 /330 LPD have 30 ETC tubes. Replacement of single tube shall be considered as single Job. | 30 | Each | - | - |
| 8 | Supply and fixing of Solar Water Heating rod of capacity 3 KW made of nichrome alloy replaced with existing rod of any type & any make including taking down old unserviceable complete all as specified and directed. | 25 | Each | - | - |
| 9 | Supply and fixing in replacement of Sheet metal enclosure for DBs when MCBs to be used 2 way SPN including taking down old unserviceable complete all as specified and directed. | 20 | Each | - | - |
| 10 | Supply and fixing in replacement of Unplasticised PVC (uPVC) 25mm bore pipes of pressure rating 10 Kgf/Sqcm fixed complete to walls, ceilings or in floors etc., including fittings as bends, elbow, reducer, sockets including taking down old unserviceable pipe complete all as specified and directed. | 24 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
8473Tenderdocument.pdf
Tender Documents • 0.81 MB
BOQ_884454.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .