HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
REPAIR/MAINT OF CENTRAL AC PLANTS AT 510 ABW, CMVL AND DCN DABATHWA OF AGE E/M WATER SUPPLY UNDER GE (U) E/M MEERUT CANTT
2021_MES_461921_2
93977/MRT/2021-22/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹500
GE (U) E/M Meerut
₹64,000
Yes
27 Oct 2021
2 Sept 2021
28 Sept 2021
2 Sept 2021
24 Sept 2021
10 Sept 2021
Amount
Supply and fix in repair Miniature circuit breakers TP, 32 Amps, 415 Volts, 50 hz, 10 KA, 'C' curve rating complete all as specfied and directed. (Note:- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
All as per item No. 1.00 above but MCB 63 Amps.
Supply and fixing MCB single pole 6 to 32 Amps, 10KA breaking capacity, B series 240 volts make:- C&S, ABB, HAVELLS, LEGRAND.
Supply and fixing MCB four pole 63 amps, 10KA breaking capacity, B series 240 volts make:- C&S, ABB, HAVELLS, LEGRAND.
Supply & fixing electronic timer for star delta timer 3 sec - 120 sec for 240 volts, 3-30 seconds complete all as specified.
Supply & fix in repair MCCB 4P 100 Amps, lcu=36KA, 415 volts, 50hz, AC, with Adjustable Thermal release (0.7 to 1.0 In), fixed magnetic type suitable release for 10.0 In duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed. Make:- Havells/C&S/LT/Seimens/Legrand.
All as per item No 8.00 above but TPN 125 amps capacity Make:- Havells/C&S/LT/Seimens/Legrand.
All as per item No 8.00 above but Four pole 400 Amps, 35KA capacity Make:- Havells/C&S/LT/Seimens/Legrand.
All as per item No 8.00 above but TPN 250 Amps, 35KA capacity Make:- Havells/C&S/LT/Seimens/Legrand.
Supply & fixing ML4 type power contactor 3 pole, 415 V, 50 Hz, with auxulary Contact 2 NO+2NC suitable for Non-inductive or slightly inductive, Resistive Load (AC1-45 Amps rating)/ Squirrel Cage Motor (AC3-40 Amps rating) to match with the existing complete all as specified.
Supply & fixing ML3 type power contactor 3 pole, 415 V, 50 Hz, with auxulary Contact 2 NO+2NC suitable for Non-inductive or slightly inductive, Resistive Load (AC1-45 Amps rating)/ Squirrel Cage Motor (AC3-40 Amps rating) to match with the existing complete all as specified.
Supply & fixing 3 TF50 type power contactor 3 pole, 415 V, 50 Hz, with auxulary Contact suitable for Non-inductive or slightly inductive, Resistive Load (AC1)/ Squirrel Cage Motor (AC3) to match with the existing complete all as specified.
Supply & fixing of ball bearing for electric induction motor of 2 HP to 5 HP capacity as per existing shape and size complete all as specified and directed.
Supply & fixing Spare coil for contactor suitable for ML4 type power contactor 3 pole, 415 V, 50 Hz AC to match with the existing complete all as specified.
Supply & fixing Spare coil for contactor suitable for ML3 type power contactor 3 pole, 415 V, 50 Hz AC to match with the existing complete all as specified.
Supply & fixing spare contactor kit suitable for 3 TF50 type power contactor, 3 pole 415 V, 50 Hz AC to match with the existing complete all as specified.
Supply & fixing spare contactor kit for Contactor suitable for ML3 type power contactor 3 pole, 415 V, 50 Hz AC to match with the existing complete all as specified.
Supply & fixing spare coil for contactor suitable for 3 TF 50 type power contactor, 3 pole 415 V, 50 Hz AC to match with the existing complete all as specified.
Supply and fixing Bimetal overload relay suitable for, Direct Mounting on ML-4 contactor, (Directly Operated) range upto 15 Amps to match with the existing complete all as specified
Renewal of High Pressure and low pressure control (HP&LP) switch suitable for 11 TR Air cooled package type AC unit ( Make- Blue Star) complete all as specified.
Supply & fixing thermostate/ temperature control switch suitable for 1x16.5 TR Air cooled package type AC unit ( Make- Blue Star) complete all as specified.
Supply & fixing thermostate/ temperature control switch suitable for 1x22 TR Air cooled package type AC unit ( Make- Blue Star) complete all as specified.
Supply & fixing anti freeze switch suitable for Central/ package type AC plants complete all as specified.
Dismantling/taking down burnt squirrel Cage Induction Motor of any capacity, 3 pahse, 415V, 1450 RPM of any make from its base and transporting the motor to the Contractor's workshop and back, refixing the motor at site after carrying out the following repairs/renewals complete all as specified. (i) Opening the side covers and removing the rotor and cutting/ removing the burnt coils / winding from stator. (ii) Cleaning the slots carefully. (iii) Rewinding the stator using super enamelled copper winding wire with same size, number of coils, number of turne / coils as per data acquired from the old burnt motor, including varnishing two coats, drying and reassembling the elctric motorat site. (iv) Testing the coils for there continuity and no current passing through the stator core. (v) Dynamic testing of the rotor and alignment of the main shaft and ensure that no imbalance vibrations. (vi) Re-assembling the rotor and connecting the end terminals to the terminal plate of the motor, closing the ends with side covers. (vii) Testing and commissioning the electric motor connecting to the electric supply to its full load by connecting the compressor. (viii) Renewal of Bolts, nuts and washers. (ix) Note:- Parts renewed i.e. Ball bearing shall be measured and paid separately. However filling of grease and oiling extra shall be deemed to be included in Unit rates.
Repair/replacement of water pressure gauge suitable for water circulating pipe with any dia inlet & out let pipe by means of proper welding and connection with checking the running water pressure as per specification all as directed by Engr-in-Charge.
Supply & fix in repair thermostate expansion valve of 1x11 TR working on R-407/410 (c) NON CFC refrigerent gas (Ecofriendly) suitable for 1x22 TR package type AC plant (Make- Blue Star) including collecting the refrigerent in the empty cylinders arranged by the contractor at his own resources by any means, cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc complete all as specified.
Supply & fix in repair thermostate expansion valve of 1x5.5 TR working on R-407 (c) NON CFC refrigerent gas (Ecofriendly) suitable for 1x16.5 TR Air cooled package type AC plant (Make- Blue Star) including collecting the refrigerent in the empty cylinders arranged by the contractor at his own resources by any means, cutting, welding, brazing, renewal of gasket, nuts, bolts and washers etc complete all as specified.
Supply & fix in repair of 25mm PVC flexibile type pipe suitable for indoor AC plant drain water complete all as specified.
Supply & fixing V Belts of size B-154 complete all as specified.
Supply & fixing V Belts of size B-81 to B-100 complete all as specified.
Supply & fixing V Belts of size B-61 to B-80 complete all as specified.
Supply & fixing V Belts of size B-40 to B-60 complete all as specified.
Supply & fixing drier for liquid line suitable for 11 TR compressor of 10 x 15 TR AC plant complete all as specified. Make:- Danfoss.
Supply & fixing drier for liquid line suitable for 11 TR compressor of 22 TR plant complete all as specified.
Supply & fixing drier for liquid line suitable for 5.5 TR compressor of 11 TR AC plant complete all as specified.
Supply and fixing finned strip heater, single phase strip heater 3 KW suitable for AC plant including provision of nuts, bolts & washers etc all as specified and directed.
Renewal of Fan Blade suitable for Air cooled package type AC outdoor unit (Make- Blue Star) of any capacity complete all as specified.
Renewal of transformer with CT base unit suitable Air cooled package type AC indoor unit (Make- Blue Star) of any capacity complete all as specified.
Supply & fix in repair including testing harmetically sealed scroll compressor of 5.5 TR Air Cooled package type AC indoor unit of 1x16.5 TR capacities (Model No DPA-2642R2 of Blue Star), suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
Supply & fix in repair including testing compressor harmetically sealed scroll compressor of 11 TR Air Cooled package type AC indoor unit of 1x22 TR capacities (Model No DPA-2642R2 of Blue Star), suitable for 407(c) non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
Supply & fix in repair including testing compressor harmetically sealed scroll compressor of 11 TR Air Cooled package type AC indoor unit of 10x15 TR capacities (Model No SH120A4ALC of Danfoss commercial compressors), 380-400 Volt 3 phases 50Hz, suitable for 410 A non CFC refrigerent gas including necessary brazing work to make the system leak proof complete all as specified and directed.
S&F in replacement including testing for suction line Accumulator with emerson climate technologies, operation design to 40 F degree evaporator temperature, suction gas temperature as low as 12 F degree, compressor heat exchanger housing/accumulator suitable for 7.5 TR compressor inlet & outlet copper pipe make: Danfoss including necessary brazing work to make the system leak proof complete all as specified and directed.
Supply and fixing replacement of gate valve 25 mm dia with iron wheel head, screwed both end and complete fitting all as specified and directed.
Supply and fix in repair of butterfly valve 60 mm dia and complete fitting as specified and directed.
Supply and fixing of coupling suitable for 5 HP Monoblock pump by means of necessary nut, bolt, washer & gland including other necessary electrical works will be carried out complete fitting all as specified and directed..
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.50 mtr deep below ground level with top edge of the plate not less than 1.75 mtr below ground level connected to galvanized earth strip 32x6mm by means of bolts, nuts, check nuts and washers of GI or steel surrounded with adequate quality of charcoal dust mixed with salt on all side of earth plate including Funnel with watering pipe, wire mesh and copper lugs etc as specified and complete earthwork PCC 1:2:4 chamber and RCC 1:2:4 cover all as shown in electrical plate No 5 and all as specified and directed.
Repair of Thermometer suitable for watering circulating pipe with any dia by means of proper welding and connection with checking the running water temperature as per specification all as specified and directed.
Renewal/Topping of non freezing compressor oil N-46 in factory sealed containers in standard packings as directed.
Dismantling existing Monoblock pump with motor 3 HP to 10 HP, 3 phase, 415 Volts, servcing of pump and motor by opening of pump, machining of pump shaft, renewal of gaskets, gland packing, Gun metal bushes, bearing, greasing of bearing, Painting complete all as specified. (Note:- Ball bearing renewed and motor winding shall only be measured and paid separately).
M & L for Insulation metarial for MS pipe with PUF slab 80mm thick with and including applying aluminium sheet and GI cladding with 26 Gauge GI sheet complete of existing sizes all as specified and directed.
Supply and fixing charging of Refrigerent gas R-407 (c) Non CFC (ecofreindly) in company sealed cylinders of any capacity complete all as specified. (Note:- If the recharge refrigerent gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
Supply and fixing charging of Refrigerent gas R-410 (c) Non CFC (ecofreindly) in company sealed cylinders of any capacity complete all as specified. (Note:- If the recharge refrigerent gas is leaked within 45 days of running of AC plant, the contractor shall recharge gas (including supply) without any extra cost to department.
M&L for taking down/dismantling of portion of false ceiling for internal cleaning of air ducts with cloths with care and depositing the dust partiucle in the container, removing the grills/ diffusers, and refixing the grills, diffusers and false ceiling in its original locations including renewal of screws complete all as specified and directed. (16.5 TR, 8.75 TR, 11 TR, 22 TR, &150 TR).
M&L for servicing of 4x22 TR air cooled package type Air Conditioner plant (Make Blue Star) by opening the plant, consisting indoor unit-01 No and outdoor Unit-02 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units-2 Nos each, washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerent pipes and reassembling the complete units and testing complete all as specified and directed.
M&L for servicing of 3x16.5 TR air cooled package type Air Conditioner plant (Make Blue Star) by opening the plant, consisting indoor unit-01 No and outdoor Unit-03 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units-3 Nos each, washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerent pipes and reassembling the complete units and testing complete all as specified and directed.
M&L for servicing of 8.75 TR air cooled package type Air Conditioner plant (Make Blue Star) by opening the plant, consisting indoor unit-01 No and outdoor Unit-02 Nos with air blower including cleaning Air conditioner internally and externally, cooling coil and condensing units-2 Nos each, washing of filter of IDU with water, and drying in shade, checking and rectifying any oil leak, gas leak in all refrigerent pipes and reassembling the complete units and testing complete all as specified and directed.
M&L for servicing of 10x15 TR air & water cooled chiller type Air Conditioner plant (Make Daikin) by opening the plant with air blower including cleaning Air conditioner internally and externally checking and rectifying any leakage of water and gas in all refrigerent pipes and reassembling the complete units and testing complete all as specified and directed.
S&F of fan contractor (KN6/KN7) for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of LPT-1 and LPT-2 for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of sensor for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F in repair of PCB for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of solonoid valve for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of connector 4 pole 32 Amp MCB for fan motor 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of loader unloader for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of relay and overload of 34 Amps for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of power contactor 3 pole 40 Amps for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
S&F of remote control for 10x15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
M&L for Repairing/Rewinding of induction motor of chiller pump for 10x15 TR AC plant at DCN Dabathwa complete all as specified and directed.
Suuply and fixing installing, testing and commissioning of external thermal insulation of class O conforming to BS 476 Part 7 on ducts with 9mm thick nitrile rubber having density 33 Kg/cum and thermal conductivity not exceeding 0.035 W/mK at and average temperature of 400 Centigrade with netrial rubber 9mm thickness including sealing the joints with aluminium tape and finally strapped with 12mm wide packing strips at 1mm c/c duly laminated with Aluminium layer complete all as specified.
M&L for insulation material resin bonded fiberglass wool (density of 24 Kg/Cum) the thermal conductivity of the insulation material shall not exceed 0.034 kcal per hr-sq meter degree C/meter all as specified and directed. Note: Thickness of the insulation shall be 40mm for indoor duct.
S&F in repair for duct material fabricated from of aluminium or from galvanized steel sheet of thickness 1.25mm with all necessary nut, bolt, washers and all welding work all as specified and directed.
S&F in repair of galvanized steel duct of thickness 1.25mm suitable for ventilation plant with necessary clamps and hangers etc all as specified and directed.
M&L for Nitrile suitable for exposed duct with 50mm thickness all as specified and directed.
M&L for framed work as for outdoor unit of package AC plant by means of joist, channel, engle or tee section, flat section without connecting plates etc. grade - Fe 290 (Gde E-165) complete all as specified and directed.
Supply and fix Single phase preventor for system supply 415 V, AC, 50 Hz, Make-minilec, model VSP-2 D
S&F in repair of PCB for 1x8.75TR AC plant at 510 ABW ERG complete all as specified and as directed.
M&L for taking down/dismantling of portion of false ceiling for internal cleaning of AHU, repair and servicing AHU Motor fan fins and greesing of bearing the care and depositing the dust partiucle in the container, removing the grills/ diffusers, and refixing the grills, diffusers and false ceiling in its original locations including renewal of screws complete all as specified and directed. (10x15TR)
S&F in repair of oil separator for 15 TR AC plant at DCN Dabathwa complete all as specified and as directed.
Manish Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .