RequiredAnnual Turnover Portable Emergency Lighting Sysetem ( 158 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Availibality of Patent rights from Shri SANJEEV MITAL r/o
RequiredPlot no. 102
RequiredAditya hill top residency
Requiredhuda height
RequiredMLA colony road no 12
Requiredbanjarahills
RequiredHyderabad- 500034
Requiredwho have purchased Patent Right in India for Inflatable Emergency Lighting System vide Patent No. 191538 Dt- Yes * 1/6 16.02.1999 shri GUIDO MEDICI of E.I.L System Itealy. License No. from Patent Holder. (Copy of License shall be furnished to buyer on demand) - * Date - * Model No - * CONSTRUCTIONAL Generator Set: Recoil Starting Portable AC Generating Set Comprising AC Generator rated of different VA 230V 1 Phase of unit Power Factor Conforming to IS: 13364 part 1/92 and petrol Run air Cooled four Stroke singal cylinder engine with resettable circuit breaker in the AC output Yes * Genetor Power Output (VA) 1200 * Fuel tank capacity for continuous running of Genrating set for 8 hours. Yes * A fuel level indicator should be on display panel. Yes * Outside Wind Speed at which the balloon shall remain erected. (km/hr) 45 * Radius up to which min. lux value of 1 shall be available after 5 minutes of Starting. (meter) 55 * Base Plate: - Sheet Thickness of Aluminium Base Plate. (mm) 3 * Ingress protection rating of the Inflated tower as per IS:10322 Part 1/82 IPX5 * No. of compressors/air Two * 2/6 blowers of suitable rating (Nos) Balloon shall be cylinderical shaped made of suitable polyster based cloth to ensure emission of light with minimum loss and shall be waterproof and strengthened with flexible stiffereners to sustain inside air pressure and to remain erected against outside wind speed Yes * Lamp Lumens. (lumen) 42000 * Top Cover : Made of moulded fibre glass or suitable material designed to fasten the tower balloon by suitable steel strip so that there is no air leakage at the joint. It shall provide suitable nipple/hole for filling air into the balloon and provide support for it to remain erect at wind speed of 45 km/hr. Yes * The System shall be suitable for continious running for 8 hours
Requiredwithout adversaly affecting the components. Yes * Overall dimensions in deflated condition nominal (mm) 600 x 450 x 500 * Control Gear shall be suitable designed and fitted with MCB
Requiredlamp ballast
Requiredignitor
Requiredcapacitors
Requiredchangeover and on/off switches with indicating lamps for controlling HPMH lamp and air blowers. Yes * The Inflated tower only shall be rain proof Yes * Lamp wattage (watt) 400 * Base Frame shall consist of MS tube YES * 3/6 frame and a base plate of aluminium sheet of thickness to support generating set and control gear box and shall be provided with anti vibration rubber pads. M.S. Parts shall be powder coated. Maximun Deflation time including repacking time (minute) 5 * The length of nylon rope supplied for the stays. (meter) 5 * Max total weight of complete system (excluding storage box) (kgs) 50 * Balloon height in inflated condtion from base plate. . (meter) 4.5 * Maximum Time Taken to Inflate the balloon (sec) 60 * Rope dia (mm) 3 * No. of Rope (Nos) 3 * High pressure Metal Halide; lamp shall be mounted inside the balloon at the top end such that it goes up/down while inflating and deflation. Yes * System also work on 220/230V 50 Hz AC mains with provision for 3-pin socket Rating and a suitable lead wire with plugs at both ends. (Amp) Yes * CERTIFICATIONS Availability of Test Reports from Central Government or NABL or ILAC accredited Lab to prove conformity to the specification Type test Reports shall consist of Verification of all the feature and functional parameters Type tests Yes * 4/6 for alternator as per IS 13364 part 1 1992 Reaffirmed 2003 excluding tests as per clause 20 4 1 b d e
Requiredm and p of IS:13364 pt 1 1992 Type tests for Engine as per clause 9 point 1 of IS 7347/1974 Reaffirmed in 2006 Inflated tower or luminaire shall be with IP X5 protection as per IS 10322 part 1 1982 Test report date - * Test report no - * Name of lab - * Address of the lab - * ACCESSORIES Accessories Part of supply with the main equipments Yes * Puncture Repair Tape Size 10cm x 10 cm Yes * Lamp with requisite control gear (Nos) One No * Lamp with requisite control gear (in numbers) One number each of Lamp
RequiredBallast and Igniter * Tool Kit Consisting of one number each of screw driver plug spanner and nut drive Yes * Puncture Repair Tape (in Nos) 03 Nos. * Number of blower (in numbers) One No. * Storage Box Suitably designed to accommodate the tower and other spare and easy to handle with proper locking arrangements (Nos) One No * * Bold specifications are the golden parameters.