Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹19.5 L+₹3.5 L (21.7%)Rejected-Finance C 49 B RADHA GARDEN MEERUT 250001 UP | MEERUT | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹19.9 L+₹3.9 L (24.4%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹21.9 L+₹5.9 L (36.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹23.1 L+₹7.1 L (44.3%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
23 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
CERTAIN ADDN/ALTN TO CORPS CONTROL ROOM, DATA CENTRE AND TIGER HILL OPS ROOM UNDER GE 865 EWS AT LEH
2020_MES_397863_1
138WE/L-19/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹58,000
Yes
25 Jan 2021
24 Nov 2020
25 Dec 2020
24 Nov 2020
23 Dec 2020
10 Dec 2020
60 days
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/ blankets, any thickness any type including cover fillets, complete all as specified and directed.
Dismantling framed work, timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed.
Demolition of precast block work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any guage thickness including nanital or similar pattern complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed by Engineer-in-Charge.
Dismantling unframed work, timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5 sqm and not exceeding 4 Sqm each complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass any thickness , size, quality or description from wooden/steel frame or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge.
Dismantling 100mm dia, cast iron, PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches if required, complete all as specified and directed.
Perforated particle boards or tiles for insulation and accoustic purposes, in size 600 x 600 x 12 mm thick, fixed to aluminium grid frame work complete all as specified and directed.
Aluminium anodised snap grid frame work for false ceiling size 605 x 605 mm incl hangers 6 mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size, 60mm long and expansion hold fasterns 12.5mm dia, 40 mm long complete all as specified and directed.
12 mm thick plywood, 7 ply, BWR, type BB, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
6 mm thick, veneered one side decorative plywood, Grade 1 (with BWR resin), fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
18/19mm thick block boards, grade 2 quility, interior grade, commercial type, fixed with screws to timber frame work complete all as specified and directed by Engr-in-Charge.
Wooden floor tiles/ wall panelling, 7mm thick with dove tailed joints laid over 150 micron polythene film and 3 mm thick foam (as per manufacturer's instructions) and fixed including taking down of old wooden flooring and fixed with decorative wooden beadings and corner as per site requirements complete all as specified and directed by Engr-in-Charge. Make, size, colour and texture of tiles will be approved by GE.
Second class soft wood, clean sawn, timber scantling, framed and fixed with nails complete all as specified and directed.
Precast cement concrete block, PCC 1:3:6 (M-10), type C-1, (using 20mm graded crushed stone aggregate) masonry with solid blocks exceeding 10 cms in width and setting in mortar 1:6, complete all as specified and directed.
Rendering 10 mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:6,finished even and smooth (without using extra cement), complete all as specified and as directed.
Rendering 5 mm thick, on fair faces of brick or concrete surfaces of ceiling, in cement mortar 1:3, finished even and smooth (without using extra cement), complete all as specified and as directed.
Rendering 15 mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, finished even and smooth (without using extra cement), complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of dry distemper, white or tinted, over a coat of primer complete all as specified and directed by Engineer-In-Charge.
Preparation of old decorated surfaces of ceiling and applying one coat of oil bound distemper, complete all as specified and directed by Engineer-In-Charge.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over one coat of primer, complete all as specified and as directed by Engineer-In-Charge.
Material and Labour for Non skid ceramic coloured tiles 7-8mm thick (square/rectangular) , area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigment to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:6, laid over 25mm thick cement concrete 1:2:4, type B0 (using 20mm graded crushed stone aggregates) in floors complete all as specified and as directed by the Engineer-in-Charge. Shade/Colour of tile shall be approved by the GE.
Material and Labour for Non skid ceramic coloured tiles 7-8mm thick (square/rectangular) , area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigment to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:6, laid over 25mm thick cement concrete 1:2:4, type B0 (using 20mm graded crushed stone aggregates) in floors complete all as specified and as directed by the Engineer-in-Charge. Shade/Colour of tile shall be approved by the GE.
Material and Labour for Non skid ceramic coloured tiles 7-8mm thick (square/rectangular) , area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigment to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:6, laid over 25mm thick cement concrete 1:2:4, type B0 (using 20mm graded crushed stone aggregates) in floors complete all as specified and as directed by the Engineer-in-Charge. Shade/Colour of tile shall be approved by the GE.
0.63 mm thick plain galvanised mild steel sheeting as in ridges, hips, valley gutters drips and straight flashings (length and girth as fixed) fixed with 'J' or 'L' hooks or coach screws with grade of zinc coating 275 complete all as specified and directed.
Mild Steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS-1161:1979, Gde St-240, complete all as specified and directed.
Preparation of new steel surfaces of any description, not otherwise described, over 10 cm width/girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Cutting openings, through brick walls for doors, windows and other openings or enlarging existing openings, converting windows into door openings, etc., or cutting out defective brick/block work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard core etc. to store and rubbish not exc. 50m , built in cement mortar or cement lime mortar.
Supply and Fixing Anodised Aluminium frame of standard sections for doors, windows, ventilators, sliding shutters, grills, partitions/curtain walls etc., with one or more rebates including glazing clips, glazing plates and rubber beading for fixing glass panes and prelaminated particle board etc. complete all as specified and as directed by the Engineer-in-Charge. Note : Glass panes and prelaminated particle board will be measured and paid seperately.
PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregates) as in mass concrete and filling of foundation complete all as specified and directed.
PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregates) as in surface channels and drains complete all as specified and directed.
75mm thick Plain cement concrete (1:3:6), type C-1 (using 20mm graded crushed stone aggregate), as in plinth protection, laid in alternate pannels, finished even and smooth without using extra cement, complete all as specified and as directed.
100mm thick Plain cement concrete (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in floors, laid in alternate pannels, finished even and smooth without using extra cement, complete all as specified and as directed.
Plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, coping, kneels, apex stones, bed plates and the likes including weathering, slightly rounded or chamfered angles, complete all as specified and directed.
110mm PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) with complete fittings such as switches, ceiling, regulator, sockets etc. removing materials to the store for keeping in safe custody for re-use at site and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
Taking down existing main switches and DBs including MCBs complete and removing materials from site of work and making good distrubed surfaces of walls, floors etc complete all as specified and directed.
Point wiring for one light point or fan point controlled by one switch with 1.50 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts fire resistance ISI, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 1.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Point wiring for 3-pin, 5 Amps, socket outlet on independent board with 2.5 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 2.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
Point wiring for 3-pin, 15 Amps, socket outlet on independent board with 4.0 Sqmm, PVC insulated, unsheathed, FRLS single core, multi-stranded, copper conductor cable, 1100 Volts, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed surfaces of walls and ceilings, terminated in and including rectangular PVC board for mounting fitting/ switches/ sockets and 2.50 Sqmm, copper conductor, multi-stranded, FRLS as earth continuity wire connected to earth terminal, including making good to disturbed surface as matching to existing descriptions/ specifications, complete all as specified and as directed.
S&F in replacement Modular Switch, single pole, one way, 6 Amps, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement Modular Socket, 6 Amps, 2/3 Pin complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement Modular Switch, single pole, one way, 20 Amps, complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement Modular Socket, 6/16 Amps, 2/3 Pin complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement Modular wood cover plates with frame 3 module complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement Modular wood cover plates with frame 6 module complete all as specified and as directed by Engineer-In-Charge.
S&F in replacement LED Panel round light 12W 6500K, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 2'x2' Recess/Surface mounting slim (9 mm thin) in class LED Ceiling Panels white LED Luminaries white powder coated sheet housing LED front frame blends seamlessly with Ceiling layout of capacity 36 watt (2x2) LED extruded alluminium heat sink projected in false celing, with complete accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete. Make:Crompton cat part No- LCPL-36-CDL(2x2) or equivalent in Bajaj / Havells / Philips/ Wipro/GE.
1 x 20W LED, tube light fitting mounted on integrated sleek extruded polycarbonate LED channel with white acrylic cover suitable for 230 volt 50 Hz cool white colour bipin holder connector block etc complete will all accessorized internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete. Make: Havells cat part No- LHEYBYP60E1W020 or equivalent in Bajaj/ Crompton Greaves/ Philips/ Wipro/GE.
Sub main wiring for circuit/ submain wiring alongwith earth wire with four run of 16 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi stranded, FRLS, ISI marked, 1100 Volts grade and two run of 10 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed on surfaces of walls/ ceilings, includingtaking out existing and making good to disturbed surface matching to existing descriptions/ specifications, complete all as specified and directed.
Sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 16 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi stranded, FRLS, ISI marked, 1100 Volts grade and one run of 10 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including PVC casing and capping, fire resistance, ISI marked, fixed on surfaces of walls/ ceilings, includingtaking out existing and making good to disturbed surface matching to existing descriptions/ specifications, complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, Single pole and neutral, 12 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, Single pole and neutral, 8 way with, 240 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, triple pole and neutral (TPN), 8 way with, 415 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
Sheet metal enclosures for distribution box for MCBs, triple pole and neutral (TPN), 4 way with, 415 Volts, double door, with 200 Amps rated bus bar blank plate complete all as specified and directed.
MCB, triple pole and neutral (TPN), 63 Amps, 415 Volts , 10 KA C series, complete all as specified and directed.
MCB, single pole and neutral, 63 Amps, 240 Volts , 10 KA C series, complete all as specified and directed.
MCB, single pole, 6 to 40 Amps, 240 Volts, 10 KA C series, complete all as specified and directed.
MCB, single pole, 40 Amps, 240 Volts, 10 KA C series, complete all as specified and directed.
MCB, single pole, 63 Amps, 240 Volts, 10 KA C series, complete all as specified and directed.
Load line MCCB Enclousers 'A' Frame FP with complete fixing accessories, complete all as specified and directed.
MCCB 125 Amps, 4 Pole, 415 Volt, 25 KA, lcs 75 % of Icu 'A' Frame fixed thermal and fixed magnetic setting, complete all as specified and directed.
Switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 5/ 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Switch socket combination 2-in-1, 3-pin, 15 Amps, flush type, complete all as specified and as directed by Engineer-In-Charge.
Ceiling rose, surface bakelite 65 x 50 mm two or three terminals complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 70 Sqmm 3.5 core, laid in trenches/fixing in wall suitable for clamping with accessories or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron strip 32x6mm as earth lead by means of bolts, check nuts and washers of GI and earth strip protected by provision of GI pipe light grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt, 40mm dia, medium grade, GI pipe as protection to earth lead and earth lead as 32x6mm dia GI strip (main earthing lead from earth electrode to test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing.
M/S Praveen Kumar and Sons
ASHOK KUMAR SHARMA
Rampal Singh Contractor
VIJAY ENTERPRISES
R B TRADERS
M/S NANCY ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .