Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.6 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹23.9 L+₹27,550 (1.16%)Rejected-Finance | 2 | Rejected-Finance Not L-1 | |
| 3 | 3₹24.1 L+₹46,860 (1.98%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | 3 | Rejected-Finance Not L-1 | |
| 4 | 4₹24.9 L+₹1.3 L (5.35%)Rejected-Finance | 4 | Rejected-Finance Not L-1 | |
| 5 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | - | Rejected-Technical Not accepted for opening of financial bid as the firm is not enlisted in cat c(ii) |
Tender Value
₹27.8 L
EMD Value
₹55,660
Closing Date
3 Sept 2024, 6:00 pmClosed
CWE New Delhi
HQ CWE NEW DELHI, RAO TULA RAM MARG, DELHI CANTT-10
Comprehensive, preventive and periodical maintenance of lifts at main bldg and CTVS bldg at AHRR under GE EM RR Hospital, Delhi Cantt
2024_MES_662172_1
CWE/ND-21/2024-25
Open Tender
Civil Works - Others
Item Rate
330 days
NEW DELHI
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE EM RR Hospital Delhi Cantt
₹55,660
Yes
7 Oct 2024
26 Jun 2024
5 Sept 2024
26 Jun 2024
3 Sept 2024
13 Jul 2024
Amount
Comprehensive, preventive and periodical maintenance of lifts/elevators installed in AHRR Complex as mentioned here-in-after, in reliable, safe and efficient manner using latest techniques & expertise consultancy by regularly examining, lubricating and adjusting the mechanical and electrical driving equipment, including replacement of unserviceable component such as governor sleeve, shaft assembly, bearing / contact, governor jaws, car & hall mechanical buttons, car & hall position indicators, car direction indicators and all other car and landing signal / fixtures, deflectors, counter weight, guide rails, buffers, machines motors, generators, door ropes, UPS/ARD system, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock brake shoes, liners, contactors, relays, coils, pushbuttons, door operator VVF drive, VVVF main drive, cardoor safety device, limit switches, governor, hoistway door locks, indicators and other mechanical and electrical parts (excpet car cabin, landing door, sheave rim and Srl item No 02 to 20 of Sch 'A') for smooth functioning of elevators and incl all machine works i.e. welding, cutting, drilling, screwing, etc. as and when required, to entire satisfaction of Engineer-in-charge, including cost of materials complete including Sunday & Holiday, complete all as specified & directed for following Lift(s) / Elevator(s) -
Electric Hospital passneger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors installed at A Block lift No 02 & 03 (Make : TKE Elevator) -02 Nos lifts
Electric Hospital passneger cum stretcher elevator / lifts of capacity 26 passenger serving (-1+G+4) 6 floors installed at OT(Lift No 04 & 05) (Make TKE Elevator) -02 Nos lifts
Electric Hospital passneger cum stretcher elevator / lifts of capacity 20 passenger serving (G+4) 5 floors installed Ramp side (Lift No 7 & 8) (Make Thyseen Krup Elevator) -02 Nos lifts
20 passenger elevator of 1360 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 03 Nos installed at CTVS .
10 passenger elevator of 680 Kg capacity with traveling speed of up to 1.0 mtr/sec No. of floors - 04 (G+3)(Make : KONE Elevator) – 02 Nos installed at CTVS .
250 Kg Dumb Waiter (G+1) (Make : KONE Elevator) - 01 Nos installed at CTVS .
250 Kg Dumb Waiter (G+2) (Make : KONE Elevator) - 01 Nos installed at CTVS .
Notes for item No. 1.00 to 1.07: (i) The above maintenance shall be done through OEM of existing lifts. Please also refer Sch 'A' Notes. (ii) The contractor shall have to submit MOU from OEM M/S Thyssen Krup Elevator Company India Ltd ( for Item No. 1.01 to 1.03) & M/S Kone ELEVATOR INDIA Pvt Ltd (for Item No. 1.04 to 1.07). (iii) The rates quoted shall be inclusive of T&P required for carrying out repairs, stationary for maintenance of record all as specified. (iv) All the cleaning items (Dusting cloths, floor/Glass cleaner, SS steel cleaner, broom etc) shall be provided by the contractor and rates deemed to be included in the quoted rate. Otherwise a penalty of Rs. 100/- per day will be charged. (v) Any items not covered in Sch 'A' shall be deemed to be included in this section for the smooth functioning of lifts and the contractor may quote the rate accordingly. Contractor is expected to inspect the lift before quoting the rate and Lifts will be handed over in the same condition. No claim will be admissible thereof.
Notes for item No. 1.00 to 1.07 (contd.):- (vi) Contractor shall be attending complaints round the clock i.e. 24 hrs. If contractor is not able to rectify the complaint, penalty shall be charged as given below:- (a) up to 1st day- NIL (b) 2nd day- Rs 1000/- day (c) Subsequency for every days - Rs 2000/day. (vii) Contractor shall be responsible to register the day to day complaints of lifts and addressed the same with in the stipulated timeframe and the complaint register will be putup to the JE / Engr-in-charge on daily basis. (viii) The comprehensive / preventive / periodical maint incl fortnightly, monthly, quarterly, half yearly inspection / testing as per service manual or as per IS standard will be submitted to Engr-in-charge. (ix) Contractor shall submit safety security certificate of lifts from OEM in every month as per performa mentioned in tender documents. (x) Adequate arrangements shall be made to dewatering the lift pit as and when water accumulates. Cost Should be included in the quoted rate. Otherwise penality of Rs 500 per day per lift will be recovered from the contractor. (xi) Contractor shall be responsible to update the imp tele number and safety precautions of inside the car cabin of each lifts and update the same time to time.
Supply & fix in replacement of SMF battery , 12 V 7AH complete all as specified & directed.
Supply & fix in replacement of SMF Battery 12 V 12 AH complete all as specified & directed.
Supply & fix in replacement of SMF Battery 12 V 18 AH complete all as specified & directed.
S&f in replacement lithium Ion batteries (alkaline) 9v complete all as directed.
M&L in repair of 1350 Rpm Car Fan as per existing type and size complete all as specified & directed.
Supply & fix in replacement travelling cable multistranded copper conductor of size 12 core 0.5 sqmm all as directed by Engr-in-Charge.
S&f in replacement copper cable 1.5 Sqmm single core, 1100V PVC round sheathed flexible type complete all as directed.
S&F in replacement RCCB/RCBO in sheet metal enclosure 40 to 63 Amps, 300mA, four pole, 415 Volts complete all as directed.
S&F in repair MCCB 4 pole 63 A 16 kA in sheet metal enclosure fix to wall complete all as directed.
S&F in repair MCCB 4 pole 160 A 16 kA in sheet metal enclosure fix to wall complete all as directed.
S&F in replacement MCB SP 6 to 16 Amps complete all as directed.
S&F in replacement MCB TPN 63 Amps complete all as directed.
Supply and fix in repair, Metallic body exhaust fan of 350/380 mm sweep, single phase including necessary addn/altn to accommodate at the existing location or making provision by cutting/chasing wall and making good the disturbed surfaces, matching with the existing colour of wall all as directed by Engr-in-Charge.
Supply & fix in repair as in shaft light of lift environmental friendly, ultra modren, energy saving LED bulk head 10W IP 65 in die cast aluminium housing & frosted glass with all connection incl wiring all as per site requirement complete all as specified and directed.
S&F in repair decorative ultra slim linear LED , 2 ' long lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack complete with inbuilt electronic driver , PCB , connector block etc including connecting up with three core twisted flexible copper conductor cable up to main connection all as per site requirement and directed by EIC.
S&F in repair decorative ultra slim linear LED 4' long (18 W) lighting fixture with extruded Al heat sink , environment friendly , energy efficient ready to use pack complete with connecting up with three core twisted flexible copper conductor all as per directed.
S&F in replacement 07 W ultra slim decorative aluminium casted, recess mounted round/square fixture (as per existing size and type) in white finish with opal diffuser and electronic driver, suitable for low depth ceiling of lift complete all as per directed.
S&F in replacement oil collectors white complete all as specified.
Supply & fix in replacement of UPS Device, 600 VA 230 V 1PH complete all as directed.
M&L Repair and adjsutment/alignment of car door and lift sills in safe and smooth manner incl welding, grouting, screw, nuts, bolt etc complete all as directed.
Providing and fixing of wall mounted signages of Zinc Sulphide Photo luminescent coating on 6mm thick acrylic sheet of size as per exiting comprise of "Floor No and Block No" Complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair GI strip 32x6mm, buried in ground or fixed to wall incl saddling and insulator etc for loop earthing.
Iconic Engineers (BID ID -3071842)
M/s Dhapola Elevator and Engineering (BID ID -3067220)
Akarsha Enterprises (BID ID -3068354)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .