Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC VALID | |
| 2 | L2₹43.4 L+₹5.7 L (15.2%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹43.9 L+₹6.2 L (16.3%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹45.5 L+₹7.7 L (20.5%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance not being lowest |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
3 Jan 2022, 6:00 pmClosed
GE (AF) SURATGARH
GE (AF) SURATGARH
SPECIAL REPAIRS TO CERTAIN LT PANELS AND AMF PANELS AT AF STATION SURATGARH
2021_MES_492575_1
8920/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹77,600
Yes
25 Jan 2022
4 Dec 2021
5 Jan 2022
4 Dec 2021
3 Jan 2022
18 Dec 2021
Amount
(SPECIAL REPAIRS TO CERTAIN LT PANELS AND AMF PANELS AT AF STATION SURATGARH)
Supply, installing, testing and commissioning factory made AMF Panel CPRI approved for 160 KVA capacity DG set indoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following . (Note:- The Item includes control cabling from DG set to AMF Panel as per requirement)
Supply, installing, testing and commissioning factory made AMF Panel CPRI approved for 200 KVA capacity DG set indoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr, complete all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following . (Note:- The Item includes control cabling from DG set to AMF Panel as per requirement)
Supply, installing, testing and commissioning factory made AMF Panel CPRI approved for 50/30 KVA capacity DG set indoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following . (Note:- The Item includes control cabling from DG set to AMF Panel as per requirement)
Supply, installing, testing and commissioning factory made AMF Panel CPRI approved for 82.5 KVA capacity DG set indoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following . Note:- The Item includes control cabling from DG set to AMF Panel as per requirement)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- DSS, Block 257, 2209 Tech flt)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 36 kA 200 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 36 kA 160 Amp- 01 Nos . (iii) MCCB 4 pole 25 kA 100 Amp- 02 Nos. (iv) MCCB 3 pole 25 kA 63 Amp- 03 Nos (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- TRS Billet, Block 311, Photo sec, GE office,275 SU)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 36 kA 250 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 36 kA 160 Amp- 01 Nos . (iii) MCCB 4 pole 25 kA 100 Amp- 03 Nos. (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (v ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vi) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (vii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI apporved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- Officer Mess, SMC )The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 36 kA 400 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 36 kA 250 Amp- 01 Nos . (iii) MCCB 4 pole 25 kA 100 Amp- 03 Nos. (iv) Onload changeover switch 400 amp -01 No. (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- OMQ MAP Qtr, Transmitter Sec,)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 36 kA 160 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 25 kA 100 Amp- 02 Nos . (iii) MCCB 4 pole 25 kA 63 Amp- 03 Nos. (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (v ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vi) Spare chamber for future extension of MCCBs as per requirement - 01 spare compartment. (vii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells)
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- JWO Qtrs Maru Vihar)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 35 kA 315 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 36 kA 160 Amp- 03 Nos . (iii) MCCB 4 pole 25 kA 63 Amp- 01 Nos. (iv) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (v ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vi) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (vii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells).
Supply, installing, testing and commissioning factory made LT Panel CPRI approved feeder pillar box outdoor type platform mounted, suitable for accomodating all MCCBs with input voltage 415 volts 3.5 phase 4 wire, 50 Hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish over a coat of red oxide, primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platform of suitable size with PCC 1:3:6 type C-2 using with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. (Location- WSA)The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings
(i) MCCB 4 pole 36 kA 160 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB 4 pole 25 kA 100 Amp- 02 Nos . (iii) MCCB 4 pole 25 kA 63 Amp- 03 Nos. (iv) MCB DP 32 Amp - 04 Nos (v) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (vi ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (vii) Spare chambers for future extension of MCCBs as per requirement - 01 spare compartment. (viii) Phase indiacting lamps (R-Y-B) - 01 set. (Make of MCCB/MCB/Contactor/Changeover switch:- L&T/Schneider/Havells)
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil, complete all as specified and directed by Engr-in-Charge.
Returning, filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-Charge.
M&L for providing Fazilka river sand as in sand cushioning to under ground cable including punning down of sand in layers , complete all as specified and directed by Engr-in-Charge. Note:- Punning down thickness shall be measured.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed
Taking out LT XLPE cable of any size, complete all as specified and directed by Engr-in-Charge.
Boring of holes under road, pavement, hard standing by using necessary machine for passing armoured cable and provide GI pipe of light grade both end socketed,complete all as specified and as directed by Engineer-in-Charge.
M&L for 50 MM bore galvanized steel tubing light garde (ISI marked) protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L for 80 MM bore galvanized steel tubing light garde (ISI marked) protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L for 100 MM bore galvanized steel tubing light garde (ISI marked) protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L for 150 MM bore galvanized steel tubing light garde (ISI marked) protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm 3.5 core,complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm 3.5 core, complete all as specified and directed by Engr-in-charge. Note: Earthwork and excavation shall be measured and paid separately.
Material & labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25 x 4 mm, 7.5m long by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, including dismantling old earthing complete all as specified and directed by Engr-in-Charge.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General summary on serial page No 16 of tender documents.
Gupta Suppliers
GURDEEP SINGH AND COMPANY
M/S BUDHRAM BISHNOI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .