Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.8 L+₹1.2 L (3.88%)Rejected-AOC | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹31.7 L+₹2.0 L (6.66%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹31.8 L+₹2.1 L (7.07%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹32.6 L+₹2.9 L (9.73%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
3 Dec 2024, 6:00 pmClosed
Shri Rajesh Kumar Meena, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
SPL REPAIRS REPLACEMENT OF ALUMINIUM WIRING INTO COPPER WIRING ALONGWITH CONNECTED ITEMS AT JCOs OR MD ACCN BLDG NO P 437 438 474 TO 478 56 QTRS AT ALLENBY LINE AMMUGUDA UNDER GE NORTH SECUNDERABAD
2024_MES_683594_1
8840
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹94,000
Yes
18 Jan 2025
12 Nov 2024
10 Dec 2024
12 Nov 2024
3 Dec 2024
26 Nov 2024
Amount
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified and directed by Eng- in Charge.
M & L Point wiring with 1.5 Sq mm FRLS copper conductor single core PVC insulated sheathed 1100 V multistranded confirming to IS-694 drawn in existing with new sunk type pressed steel terminal boxes suitable for modular switches including fixing/grouting sunken/ concealed as per site requirement covered with suitable modular cover plate for suitable size for mounting of modular switches, regulators and drawing continuous earth wire with one run of 1.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly and making good the disturbed wall surfaces to match with the existing surfaces etc for one Light/Bell point controlled by One Switch complete all as specified and directed. Note: 1. Modular Cover Plate is inclusive of the rated quoted by the contractor
All as per Sl item No 2 here in before, but for One Ceiling fan/Exhaust fan point controlled by one one way switch and regulator
All as per Sl item No 2 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the independent board.
All as per Sl item No 2 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No 2 here in before, but for One Light point controlled by two,two way switch 5 Amps,single pole
All as per Sl item No.2 here in before, but for using 2.5 Sqmm FRLS single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor complete all as specified and directed.
S & F Modular switch 1 way 6 Amps, 1 Module capacity,230 V, complete all as specified and directed.
S & F Modular socket 5 pin, 6 Amps,2 Module,230 V complete all as specified and directed.
S & F Modular socket 6 pin,6/1 6 Amps,2 Module,230 V complete all as specified and directed.
S & F Modular switch 1 way, 16 Amps, 1 Module capacity,230 V, complete all as specified and directed.
S & F Modular electronic ceiling fan regulator 5 stepped type heavy duty suitable to work on 230 volts, complete all as specified and directed.
S & F Modular Bell push,6 Amps,SP,230 V,AC complete all as specified and directed.
S & F Modular switch 2 way, 6 Amps, 1 Module capacity,230 V, complete all as specified and directed.
S & F Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed.
S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S & F Ding dong bell AC,230 V,SP complete all as specified and directed.
S & F 20 W wall mounted Indus plus LED batten with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver,230 V,bipin holders,diffused type connector block and connecting to all accessories with 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed.
S & F LED security Light luminaire fitting 1x35 watts with deep drawn housing including all accessories and LED 35 W Lamp, with suitable 40 mm dia GI pipe bracket 25 mm dia 0.60 Mtr length fixed on wall with 50x6 mm flat iron, clamps and nut bolts all as specified and as directed.
S & F in repairs Decorative oval bulk head luminaires LED light fitting 1x9 W/1x10 W ,comprising of high brightness,environmental friendly, ultra modern,energy saving,surface mounted, with accessories and connectingwith 3 core multi stranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed.
S & F Decorative Fancy type lights (Round Type) of 20 watts including LED lamp in bed room or hall complete with all accessories all as specified and directed.
S & F Sheet metal enclosure MCB DB SPN 8 way with suitable rated bus bar 240 volts double door with magnetic locking system complete all as specified and directed.
S & F MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB's complete all as specified and as directed.
S & F MCB SPN 40 Amps 240 volts for fixing on MCB DB's complete all as specified and as directed.
M & L Submain wiring with 4 runs of single core 10 sqmm FRLS PVC insulated sheated multistranded 1100 volts grade with copper conductor drawn through existing non-metallic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 10 sqmm FRLS PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 5 runs of 10 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
S&F Ceiling fan of size 1200 mm sweep,230 V, with blades,minimum air delivery 210 CFM with service value 6 BEE,5 star rated with brushless direct current motor (BLDC) including down rod,with provision of PVC insulated copper flexible cable from ceiling rose to connection of fan complete all as specified and directed by Eng-in-Charge.
S&F Exhaust fan of size 250 mm sweep,230 V,50 Hz,1200 RPM, copper winding made of sturdy engineering plastic complete with louvers shutter with provision of PVC insulated copper flexible cable from ceiling rose to connection of fan including making hole to sut the fan and making good with the existing surface complete all as specified and directed by Engr-in-Charge.
Taking down existing old vintage ceiling fans of any size and depositing to MES store yard complete all as directed by Engr-in-Charge.
Sri Associates (BID ID -3179894)
BHATNAGAR ASSOCIATES (BID ID -3179292)
SRI SAI RAM ENTERPRISES (BID ID -3179339)
Sri Balaji Enterprises (BID ID -3179507)
SHAH ENTERPRISES (BID ID -3179500)
STANDARD AGENCIES (BID ID -3179493)
K LAKSHMAN SINGH AND CO (BID ID -3174881)
GVR ENGINEERING WORKS (BID ID -3180134)
MVS ENTERPRISES (BID ID -3177365)
SUN LIGHT HOUSE (BID ID -3179950)
M/S M.N.Reddy (BID ID -3180096)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .