Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹28.9 L+₹1.1 L (4.12%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹30.0 L+₹2.2 L (8.02%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹30.2 L+₹2.4 L (8.74%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹31.5 L+₹3.7 L (13.4%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
8 Feb 2021, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARSHTRA
REPAIR REPLACEMENT OF LT UG CABLE REPLACEMENT OF LT FEEDER PILLAR AND CERTAIN OTHER MISC WORKS AT ABHIMANYU FODC NHK NAI NBCD HARD AND TUNIR AREA AT NAVAL STATION KARANJA
2020_MES_407704_2
8310/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
REPAIR REPLACEMENT OF LT UG CABLE REPLACEMENT OF LT FEEDER PILLAR AND CERTAIN OTHER MISC WORKS AT ABHIMANYU FODC NHK NAI NBCD HARD AND TUNIR AREA AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹70,000
Yes
30 Mar 2021
1 Feb 2021
10 Feb 2021
1 Feb 2021
8 Feb 2021
3 Feb 2021
1 Feb 2021 - 3 Feb 2021
Amount
M&L for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes.
The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following :
Location : DSC Line Tunir Main LT Panel (A) INCOMING - (a) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 50kA breaking cap. adjustable thermal release range 250 Amps Cat ref no. 4202 79 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 01 Nos. (B) OUTGOING - (a) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 125 Amps Cat ref no. 4200 56 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 02 No. (b) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps Cat ref no. 4200 53 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 03 No. (c) Time switch Digital time switch astronomical type for switching on/off lights and other electric devices according to the rising/setting of the sun with comination function for creatomg switching programs in which the devices are switched according to astronomical time and/or fized preset time , daily atronimical calcutlation of the sunrise/sunset times based on the entered location of location cordinate having MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories - 01 No. Make - Legrand , CAT No. - 412654 or equivalent in M/s L&T /Schnieder/Hager/ABB/Havells.
LT panel all as per Item No.1 above but LT panel board of Suitable to accomodate the following accessories: Location :Near MRF Sub stn Timer Panel & Near Mangera Main gate Timer Panel (A) INCOMING - (a) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps Cat ref no. 4200 53 of make Legrand or equivalent in M/s Schenider/M/sSiemens – 01 No. (B) OUTGOING - (a) Time switch Digital time switch astronomical type for switching on/off lights and other electric devices according to the rising/setting of the sun with comination function for creatomg switching programs in which the devices are switched according to astronomical time and/or fized preset time , daily atronimical calcutlation of the sunrise/sunset times based on the entered location of location cordinate having MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories - 01 No. Make - Legrand , CAT No. - 412654 or equivalent in M/s L&T /Schnieder/Hager/ABB/Havells. (b) Power contactor 3 pole,type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts, Rating 70 Amp - 01 No. as per Cat No. SS90910 of M/s L & T, Siemens, Schneider including testing connecting commissioning complete all as specified and directed.
LT panel all as per Item No.1 above but LT panel board of Suitable to accomodate the following accessories: Location : Near Hanuman Mandir (A) INCOMING - (a) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 36kA breaking cap. adjustable thermal release range 100 Amps Cat ref no. 4200 95 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 01 Nos. (B) OUTGOING - (a) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps Cat ref no. 4200 53 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 03 No. (b) Time switch Digital time switch astronomical type for switching on/off lights and other electric devices according to the rising/setting of the sun with comination function for creatomg switching programs in which the devices are switched according to astronomical time and/or fized preset time , daily atronimical calcutlation of the sunrise/sunset times based on the entered location of location cordinate having MCB shaped design with Front display and DIN rail mounting, power reserve for atleast 1500 hrs, operating voltage - 240 V AC, 50 Hz, working temp. upto 55 degree celcius complete with all accessories - 01 No. Make - Legrand , CAT No. - 412654 or equivalent in M/s L&T /Schnieder/Hager/ABB/Havells. (c) Power contactor 3 pole,type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts, Rating 40 Amp - 01 No. as per Cat No. 90721 of M/s L & T, Siemens, Schneider including testing connecting commissioning complete all as specified and directed.
Supply & fixing, jointing, connecting & testing in trenches XLPE insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes including taking out cable cover & cable all as specified and directed : 4core 16 Sqmm
3.5 core 25 Sqmm
BLANK
3.5 core 50 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
3.5 core 120 Sqmm
3.5 core 240 Sqmm
3.5 core 300 Sqmm
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil including taking out faulty cable/cables and cable covers and GI pipe complete all as specified and directed.
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in Hard/dense soil including taking out faulty cable/cables and cable covers and GI pipe complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and exc 1.5 mtr depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point complete all as specified and directed.
M & L for crushed stone as sand cushioning for protection of UG cable including punning of sand in layers all as specified
Supply & laying un-reinforced precast concret cable cover class LV type 1, flat size 250mm x 150mm x 40 mm all as specified & directed.
BLANK
Disconnecting 1.1 KV grade XLPE cable of any size from structure/pole/ transformer/LT panel/FPB for finding fault and its location including cutting faulty cable to facilitate joint and testing remaining part of cable for any further fault using cable fault locating equipment including bringing approved cable fault locating equipment & to be taken back after finding fault is over all complete as specified and directed. Note :- Excavation and earth work and supply & fix joints shall be measured and paid for separately.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 25 sq mm to 50 sqmm of make 3M/M Seal/ Raychem complete all as specified and directed.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 120 sq mm of make 3M/M Seal/ Raychem complete all as specified and directed.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm of make 3M/M Seal/ Raychem complete all as specified and directed.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm of make 3M/M Seal/ Raychem complete all as specified and directed.
Supply and fix in repairs 1.1 KV straight through joint kit 3.5 core 400 sqmm of make 3M/M Seal/ Raychem complete all as specified and directed.
BLANK
M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 50 mm bore of pipe complete all as specified and directed.
M&L GI pipe light grade with all fittings complete laid in trenches all as specified for 80 mm bore of pipe complete all as specified and directed.
M & L for PCC type C2, 1:3:6 using (40 mm graded stone aggregate) in foundations ,filling and mass concrete includings necessary form work complete all as specified & directed
Taking out carefully LT UG cable following sizes after necessary excavation , removing of soil, precast cable cover and setting aside for reuse complete all as specified and directed. 2 core 10 to 25 sqmm
4 core 16 to 50 Sqmm
4 core 70 to 120 SQmm
3.5 core 150 to 240 sqmm
Relaying of LT UG cable of following sizes obtained from ser No 23.01 to 23.04 including sand filling, laying of cable cover and filling of soil complete all as specified and directed. 2/3.5/4 core 10 to 25 sqmm
2/3.5/4 core 16 to 50 Sqmm
3.5/4 core 70 to 120 SQmm
3.5/4 core 150 to 240 sqmm
Taking out cable loop after necessary excavation ,cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface for the following sizes:- 2 core 10 to 25 sqmm
4 core 16 to 50 Sqmm
4 core 70 to 120 SQmm
3.5 core 150 to 240 sqmm
3.5 core 300 to 400 Sqmm
BLANK
S & F MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 200 Amps Cat ref no. 4202 18 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps Cat ref no. 4202 19 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
S & F MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 400 Amps Cat ref no. 4220 07 of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
Earthing complete with GI earth plate electrode 60cm x 60 cm x 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip 32 x 6 mm by means of bolts, nuts and check nuts and washers etc made of GI & connected to Earthing test point and earth dolly all as shown in elect plate No 3 of SSR Pt-I incl all necessary earth work, excavation, PCC chamber, chamber cover with handle (PCC 1:2:4) including 40 mm dia protection pipe & 20 mm dia watering pipe and wire mesh funnel etc all as specified and as directed by Engr-in-charge.
M&L for cutting and cleaning of branches, bushes, roots etc around the street light pole 8.5/9/11 mtr long and Steel/Rail/PCC type with using of all safty equpment and provide complete lux and illumination lavel of street light for road complete all as specified and directed by Engineer-in-Charge.
Painting to electric control panel/LT Panel/Feeder Piller box /Bus bar panel any type and any size of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and specified.
S&F in replacement multi function meter having LCD Display,96 x 96 sq.mm Flush mounted case, accuracy class 1.0 capable of measuring Instantaneous, Average, Maximum and Total Current from 50A to 6000A and voltage from 120V AC to 300V AC Phase to Neutral, Phase to Phase Voltage, Instantaneous, Average, Maximum and Total Active Power KW, Instantaneous, Average, Maximum and Total Reactive Power KVAR, Instantaneous, Average, Maximum and Total Apparent Power KVA, Instantaneous and Total Power Factor, Frequency. Make - M/s HPL, Cat No. - emfis vifp NEMFVIE0000 or equivalent in M/s L&T/ Scheinider/Legrand/Hager.
Supply and erection of steel tubular swaged pole 410 SP 22, 8.5 Mtr long ,swan neck complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed.
Supply and erection of steel tubular swaged pole 410 SP 22, 8.5 Mtr long complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed.
Supply & Fix in repair bracket for street light fittings made out of 40 mm bore medium grade GI tubing 1.5 m long bent to shape and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair all as specified and directed.
S & F FRP Moulded cable looping box of size 250 mm x200 mmx115 mm complete with electrolytic aluminum bus bar suitable size capacity for 3 phase and neutral fixed on ebonite insulator and one MCB 6-16 A complete all as specified and directed. make : SINTEX / MEW/ NATIONAL
M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) as in coping, including form work complete all as specified & directed.
S & F Pressure die cast aluminium housing LED street light luminaires with IP66 ,EDGE Series,120 Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Bajaj Cat ref No BRTFG 120 W LED I of M/S Bajaj or equivalent in C&S/ Philips.
M & L for Preparing old surfaces of street light poles 8.5 mtr long and painting (exposed surfaces) with one coat of aluminium paint, including reflectors of colours Red, Yellow and Blue all as specified and directed by Engineer-in-Charge.
S & F MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 160 Amps of make Legrand or equivalent in M/s Schenider/M/s L&T in replacement/ repairs complete all as specified and directed.
M.K Enterprises
pk Enterprises
D.N.PATIL
ECOBUILD
India enterprices
Sagar Electricals
R A Electric Co.
Om Sai Enterprises
LAXMI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .