| 1 | L1₹18.6 LAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹19.4 L+₹43,444 (2.29%)Rejected-Finance | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹19.4 L+₹48,594 (2.56%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹21.0 L+₹2.0 L (10.7%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹21.3 L+₹2.3 L (12.4%)Rejected-Finance | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
27 Mar 2023, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
PERIODICAL MAINTENANCE AND ESSENTIAL REPAIRS TO FIRE ALARM SYSTEM AT NAVAL STATION KARANJA
2023_MES_583495_1
84210-K/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (NW) KARANJA
₹54,000
20 Apr 2023
28 Feb 2023
29 Mar 2023
28 Feb 2023
27 Mar 2023
14 Mar 2023
Amount
SCHEDULE 'A' PART-I (PERIODICAL MAINTENANCE) Material and labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system, including testing on monthly basis in presence of user representative etc including attending system fault on emergency, preventive measures by replacing minor spares (upto cost Rs 1000/- including GST and other charges) other than mentioned in Schedule 'A' part-II for fire alarm system installed at Magic Matra bldg comprising following complete all as specified and as directed by Engr-in-charge. (a) 08 Zone main control panel with zone card battery charger and 230 V power unit. (b) Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc., (c) All cable connections from main control panel to items. (d) Lead acid battery any capacity. (e) Electric Hooter
All as per item No.01 here-in-before but for compressor room bldg in EKM complex (Bldg No 784) but for 8 Zone main control panel.
All as per item No.01 here-in-before but for oxygen worksp bldg in EKM complex (Bldg No 783) but for 8 Zone main control panel.
All as per item No.01 here-in-before but for Armoury store room at INS Abhimanyu complex but for 8 Zone main control panel.
All as per item No.01 here-in-before but for Sea Cat workshop bldg in NAD (karanja) with 8 zone main control panel.
All as per item No.01 here-in-before but for Maurya Hanger but for 15 Zone main control panel.
All as per item No.01 here-in-before but for Harshawardhan Hanger (MRF P-20) but for 15 Zone main control panel.
All as per item No.01 here-in-before but for Kashmir TP but for 8 Zone main control panel.
All as per item No.01 here-in-before but for Club TP but for 2 loop Addressible type fire alarm control panel.
All as per item No.01 here-in-before but for NAD Explosive area Fire Station but for 12 Zone main control panel.
All as per item No.01 here-in-before but for NAD Main Fire Headquarter Non- Explosive area but for 12 Zone main control panel and 20 Zone Control Panel.
All as per item No.01 here-in-before but for Bldg No P-249/1 ('G' Fueling Points Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules up to 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-747 ('New 'O' Fueling Points Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-364 ('G' Damp No-4 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-742 ('O' Damp No-3 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-365 ('O' Damp No-4 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-363 ('G' Damp No-3 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-365A ('O' Damp No-2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-208 ('O' Damp No-1 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-741 ('G' Damp No-2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-248 (Old 'O' Fueling Point 2 Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Bldg No P-746 (Club Fueling Point Tunir Area) for 01 loop main control panel of capacity 99 detector & 99 Modules upto 200 with electric siren and amplifier, addressable Dectector, Manual call Point, Hooter.
All as per item No.01 here-in-before but for Type -III Accn, NAD Colony but for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per item No.01 here-in-before but for 582 Bldg but for 07 Zone main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per item No.01 here-in-before but for Type-II (A Block) Accn, Chunabhatti Area but for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per item No.01 here-in-before but for NAD Main Gate Non-Explosive area but for 12 Zone main control panel and 20 Zone Control Panel.
All as per item No.01 here-in-before but for Type-II (B Block) Accn, Chunabhatti Area but for 07 loop main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per item No.01 here-in-before but for Kakoli Bldg but for 12 Zone main control panel.
All as per item No.01 here-in-before but for Kalapi Bldg but for 24 Zone main control panel.
All as per item No.01 here-in-before but for Kiran Bldg but for 24 Zone main control panel.
All as per item No.01 here-in-before but for Komal Bldg but for 24 Zone main control panel.
All as per item No.01 here-in-before but for Kailash Bldg but for 24 Zone main control panel.
All as per item No.01 here-in-before but for Kesar Bldg but for 12 Zone main control panel.
All as per item No.01 here-in-before but for Koyal building but for 8 Zone main control panel.
All as per item No.01 here-in-before but Kalpana building but for 8 Zone main control panel.
All as per item No.01 here-in-before but Kaneri building but for 8 Zone main control panel.
All as per item No.01 here-in-before but Abhimanyu clothing Store building but for 4 Zone main control panel. Note for item Nos. 01 to 37: (i) Cost of Minor spare parts replaced other than listed in Sch 'A' Part-II shall be deemed to be included in the rate quoted by the contractor.
SCHEDULE 'A' PART-II (ESSENTIAL REPAIRS) Excavation in trenches not exc 1.5m wide and not exc 1.5m depth and getting out in soft /loose soil including taking out faulty cable/cable, cable covers and GI pipe complete all as specified and as directed by Engr-in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cms thick complete all as specified and as directed by Engr-in-charge.
Removing excavated soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and as directed by Engr-in-charge. Note: Only punned thickness shall be measured for payment.
Supply and laying un-reinforced precast concrete cable cover with embossing of cable size and capacity class LV type 1, flat size 250x150x40mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement manual call point convential type surface mounting type of standard size with alarm raising push button, plastic coated glass element suitable for conventional type fire alarm system etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement smoke detector confirming to E- 54.7 standard of size 100mm dia, height 56mm suitable to work on 24V DC (12 V DC-28 V DC) fixed with LED made out of frame retardant plastic confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement heat detector automatic reset type (class air series 65) complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement 1.5 sqmm 02 core armoured copper conductor cable ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement 1.5 sqmm 04 core armoured copper conductor cable ISI marked complete all as specified and as directed by Engr-in-charge.
Supply only lead acid battery 12V/7AH capacity (maintenance free) complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs fire alarm hooter with speaker suitable for PA system complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement for fire alarm sounders/sirens electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5m with sound output variation of +5 DB of 3500m range complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs Zone Card suitable for conventinal type fire alarm system working with 24 DC Volt complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs Power Supply Card suitable for conventinal type fire alarm system working with 24 DC Volt complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs Control Monitor Card suitable for conventinal type fire alarm system working with 24 DC Volt complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs Transformer unit suitable for conventinal type fire alarm system working with 24 DC Volt complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement multisensor with heat and smoke combination suitable for addressable type fire alarm panel board working on 24V DC (12 V DC - 28 V DC), made out of frame retardant plastic confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement Manual Call Point suitable for addressable type fire alarm panel board confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement Power Supply SMPS suitable for addressable type fire alarm panel board confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement single loop card suitable for addressable type fire alarm panel board confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of complete mother board suitable for addressable type fire alarm panel board confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new microprocessor type fire alarm control panel of 8 zone to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new microprocessor type fire alarm control panel of 12 zone to work on single phase AC supply 50 HZ fabricated out of CRCA sheet with standard size as per OEM recommendation duly painted including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable addressable type fire alarm control panel from existing position and supply, testing and install new addressable type fire alarm control panel complying with BS EN 54, single loop, Panel of Capacity from 99 detector & 99 modules upto 200 to work on single phase 50 HZ fabricated out of CRCA sheet steel as per OEM recommendation including connecting with suitable copper conductor cable from panel to floor/ roof level manual call point and upto smoke/ heat detector complete all as specified and as directed by Engr-in-charge.
Hardik Engineers
Saviour Security Systems
ECOBUILD
Peacock fire Safety & Engineering Services
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .