Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-Finance | L1 | Accepted-Finance L1 accepted | |
| 2 | L2₹50.0 L+₹98,659 (2.01%)Accepted-Finance | L2 | Accepted-Finance L2 |
Tender Value
₹49 L
EMD Value
₹35,000
Closing Date
6 Aug 2024, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle Chepauk Chennai 5
Providing Internal and External Electrification AC units Lift Genset arrangements to the newly proposed Building of Sub Registrar Office Periamet, Chennai-03.
2024_PWD_468729_1
TNPWD/10 BCM/2024-25
Open Tender
Electrical Works
Lump-sum
Periamet Chennai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹35,000
6 Aug 2024
2 Aug 2024
6 Aug 2024
2 Aug 2024
6 Aug 2024
2 Aug 2024
Amount
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) (crab tree / legrand/equ)
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) (crab tree / legrand/equ)
Wiring with 3 x 1.5 sq.mm PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories and with MS moduler box with 2nos 6A Two way module switch covered with module front plate inflush with wall and making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (3 points/coil) ( modular switches and plates are (crab tree / legrand/equ) (Staircase points)
Supply and Fixing of 1X18w/22w 4 feet LED fitting with 1 No.20W Direct LED Tube with complete set on ceiling or on wall with TW round block with PVC unsheathed copper leads from terminals to the Fittings. (Philips / Havells/equ)
Supply and Fixing of 2X22w 4 feet LED fitting with 2 No.20W Direct LED Tube complete set with 2 nos 0.5Mtr Twin conduit pipe suspension on ceiling with TW round block with PVC unsheathed copper leads from terminals to the Fittings. (Havells / philips/equ)
Supply and fixing of 42W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.(Philips / Havells/equ)
Supply and fixing of 24W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting. (Philips / Havells/equ)
Supply and fixing of Bulk Head LED fitting with suitable 9W LED Bulbs on wall with suitable necessary connections. (Philips / Havells/equ)
Supply and fixing of LED Gate Light fitting (Helia Cutoff) with 27W E27 type LED lamp on gate with suitable necessary connection. (Klite Make/equ)
Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting. (Philips/Havells/equ)
Supply and fixing of 50W track light on existing name board on wall with suitable necessary connection.
Supply and fixing of AC/DC 76 mm Buzzer / Call Suitable for 230 V 50 C/S Single phase AC supply on suitable TW board with push switch.
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod on the existing fan clamp. (Crompton/equ)
Supply and fixing of Ceiling fan Box Heavy Duty with suitable alignment in the Ceiling Concrete Roof.
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. (Crompton / Havelles/equ)
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan
Supply and fixing of 375mm (15") sweep (light duty) AC exhaust fan complete without provision of holes in the wall. (Crompton / Havelles/equ)
Supply and fixing of louvers shutters arrangements for 375mm (15") sweep light duty AC Exhaust fan.
Supply and erection of 2.0 TR capacity high wall mounting Split Air –conditioner conditioning to IS 1391 (part-2) 1992 with amendment No.1 except power consumption (norms) fixed with hermetically sealed compressor operation R32 or R410 Non CFC for wall mounting with minimum guaranteed cooling capacity and maximum power consumption suitable for operation on 230 Volt , 50 Hz, Ac power supply complete performing following functions. 1. Cooling 2. De- humidifying 3. Air circulating 4. Filtering (Make: Carrier / Blue star / Equvalent)
Supply and erection of 1.5 TR capacity high wall mounting Split Air –conditioner conditioning to IS 1391 (part-2) 1992 with amendment No.1 except power consumption (norms) fixed with hermetically sealed compressor operation R32 or R410 Non CFC for wall mounting with minimum guaranteed cooling capacity and maximum power consumption suitable for operation on 230 Volt , 50 Hz, Ac power supply complete performing following functions. 1. Cooling 2. De- humidifying 3. Air circulating 4. Filtering (Make: Carrier / Blue star / Equvalent)
Supply and fixing of 5KVA wall mounting type Automatic voltage stabilizer with time delay arrangements suitable for operation at 230 Volt, 50 Hz, AC power supply (Make: V –Guard / Equivalent)
Supply and fixing of 4KVA wall mounting type Automatic voltage stabilizer with time delay arrangements suitable for operation at 230 Volt, 50 Hz, AC power supply (Make: V –Guard / Equivalent)
Supply and fixing of suitable MS angle iron frame work support to the outdoor unit
Supply and laying of 5/8” & 3/8” copper with 3 core cord wire and insulation etc.
supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required.
Supply and fixing of 1 no.6A two module 5 pin socket, 2 nos. 6A one module switch with module cover plate (plastic) on suitable module Surface Box (Plastic) on wall with connections. (crab tree / legrand/equ)
Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. (crab tree/legrand/equ)
Supply and fixing of 1 no.6/16 A two module socket, 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI) in flush with wall with connections. (crab tree / legrand/equ)
Supply and fixing of 20A DP plug and socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection.(For AC plug) (Hager / Legrand/equ)
Supply and fixing of 32A DP MCB with suitable Sheet steel enclosure in flush with wall with necessary earth connection. (Hager / Legrand/equ)
Supply and fixing of 32A FP MCB with suitable Sheet steel enclosure in flush with wall with necessary earth connection. (Hager / Legrand/equ)
Supply and Run of 2 of 1.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with making good of the concealed portion with suitable colour.
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End.
Supply and fixing of Three phase Seven Segment type 4 way 63A distribution board with Metal Door cover Code IP42 Protection, with 63A 4 pole MCB as incoming and Sub incomers 3 Nos 40A DP MCB and 12 Nos 6-32A SPMCB as Outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Hager/legrand/equ)
Supply and Fixing of 4way 63A Vertical TPN Distribution Boards (with MCB Incomer); Double Door; IP42 with 1 No 63A 4 pole MCCB as incoming and 2 Nos 63A TP MCB, 2 Nos 32A DP MCB, 2 Nos 6-32A MCB as outgoing in flush with wall with Earth connection only. The MCB DB and MCB's should be with ISI mark.
Supply and Fixing of 4way 63A Vertical TPN Distribution Boards (with MCB Incomer); Double Door; IP42 with 1 No 63A 4 pole MCCB as incoming and 12 Nos 6-32A MCB as outgoing in flush with wall with Earth connection only. The MCB DB and MCB's should be with ISI mark.
Supply and Run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Supply, erection, testing and commissioning of 415V 50HZ 200Amps cubical type meter Panel Board suitable to accomodate 1 No 200A EB Service energy meter with Meter Reading View Glass, Lower corner side with 16 SWG thick CRCA sheet with 1"x1/4" tinned copper flats for 3 Phases and neutral with 6mm thick hylem sheets seperation of 3 Phases and neutral and with synthetic moulded insulators bus supports at equal intervals as per ISI specification and 2 runs of 1x 1/8" copper flat on rear side of the panel board for earth buses and with the following switches complete. The Panel must have a Cable and Busbar chamber. The panel should be with powder coated painting, necessary identification of outgoing loads bus capacity cable size etc., with bold letter. Supply, erection, testing and commissioning of 200A ELR (Earth Leakage Relay) with cut off switch Enclosed with 16 SWG Sheet for outer body and stiffness and doors switches supports respectively. As per the TNEB Specification.
Supply and fixing of 200A TPN sheet steel double break switch with HRC fuses and neutral on suitable angle iron frame work with MS cable entry boxes PWD earthing.
The incoming 200A switches should be connected to the bus with same size of 1 x 1/4 fixed copper flat and 63A switches should be connected to the bus by 1x1/8 fixed copper flat. The switch should be separated by 6mm thick hylem sheet separators and properly (double) earthed as per IE rules, CEIG specification. The panel should be powder coat painting Siemens grey complete with LED Digital Display for VAF Meter chamber. The cable size, capacity of switch and location should be marked with Computers Stickers .(L&T)
Supply and Laying of 3 1/2 x 185 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clarnping of 3 1/2 x 185 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
Supply and fixing of brass cable gland for 3-1/2 x 185 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 185 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Supply and Laying of 160mm dia PVC pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply, Erection, Testing, Commissioning and Handing over of 1 No 62.5 KVA Diesel Generator set of 0.8P.f, Three Phase, 415/420Volts, 50c/s, 1500RPM as detailed below 1.ENGINE: Water cooled Diesel engine suitable for generator application with a shaft Output of 600 BHP at 1500 RPM under NTP Condition as per BSS 5514/IS 10000. The engine shall comprise the following standard scope of supply: (Make Kirloskar/ Cummins) 1. Dry type Air cleaner 2. Expansion bellow 3. Radiator, Radiator fan and mounting 4. Air to air charge cooler 5. Exhaust Gas turbo charger 6. Lube oil cooler and Lube oil filter 7. Fuel filter(pre and micro)8. In-line Mono-block fuel injection pump with governor and fuel feed pump 9. Electronic governor 10. 24V Battery charging alternator 11. 24V Volt electric starter motor 12. Engine test Certificate 13. Residential Mufler 14. Fly wheel with starter ring.
ENGINE INSTRUMENTPANEL MOUNTED. Engine control panel consisting of ON/OFF/START Key Lube oil pressure guage , oil temperature gauge, high water temperature guage and electronic hour meter and RPM indicator. SAFETY SYSTEM OF ENGINE :-The Engine shall trip for the following conditions with visual alarm device 1. Low lubricating oil pressure 2. High Water temperature 3. Vee-belt failure and over speed 4. The visual indicator should be provide for Low battery indication. The engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load. 2. ALTERNATOR : Alternator capacity of 62.5 KVA / 50 KW,AC 3 phase, 50HZ, 415/420V, 0.8P.F.4 wire self excited, self regulated designed to run at 1500 RPM under NTP conditions confirming to BS 5000/ IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate (Make: Kirloskar/ Crompton/ Greaves/ Equivlent.)
3.ACOUSTIC ENCLOSURE:- Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet.The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC Machine to maintain dimensional accuracy of hole within 0.1mm Powder coating done after seven – tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE RETARDANT 64 Kg/m density mineral wool of 100mm thickness as Acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1 Mt distance shall be less than 75 DBA average or as per CPCB norms. Surface treatment – Painting: The enclosure surface shall be suitably treated for degreasing de-rusting and posphating. The canopies are passed through seven – tank treatment thoroughly. Additional features of canopies: Canopy fabricated on CNC machines with dimensional accuracy of 0.1 mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any World class Cooling package:
Canopies shall have cooling package for which it can also perform at 45 degree C/ambient temperature.No grouting required on the ground, only a level surface capable of with standing the DG weight.Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. 1150.00 30250.00 The Gen set frame shall also be provided with hooks for unloading Temperature rise inside the canopy: Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well within 5-7 deg centigrade. 4. FUEL TANK : 150 liters. Removable fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connection and mechanical uel gauge. Fuel tank can be easily removed for clearing or any maintenance. 5. BASE FRAME : The base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled,
lubricating oil pressure b. High water temperature & c. Over Speed . 33. 1 No. earth fault relay. 34. Isolator to isolate the neutral. Note: 1. The AMF control panel should be complete with necessary fuses, cables, labels, other accessories with neutral isolation arrangements. 2. The engine should trip for the following conditions a. Low lubricating pressure b. High water temperature. c. Over speed.
Supply and Run of 12 core 2.5 sqmm armoured copper control cable FRLS in suitable PVC rigid pipe on wall/Ground/ceiling with connection (For AMF to 62.5 KVA Genset)
Supply of lubricating oil and first filling with charging of starting battery and supply of 100 Ltrs diesel for 62.5 KVA Generator to run the geneset for minimum of 8 hours testing again handed over to occupied depatrment. (1Litre = Rs.100 for 100 Ltr = 100*100 = 10000)
Construction of a RCC concrete foundation of size for 62.5 KVA generator 3100(L) x 1750(B) x 1200(H) mm (approx weight 1500 KG) with cement concrete 1:2:4 with sand cushion all around the foundation for the erection of 62.5 KVA Generator set with proper alignment.
Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and clamping of 3-1/2 X 70 sqmm PVC armoured LTUG cable on post or on wall with MS clamps
Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
Earthing as per ISI specification with an earth electrode of 2.1mtr class ‘B” GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mmx6mm with necessary funneling arrangement with necessary masonry work with 38 mm RCC cover slab for brick masonry works.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/support on wall / floor/ground for earth connection
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Supply, Erection, Testing, Commissioning and Handing over of 1No 13 Persons Passenger Lift as per following technical specifications including all taxes and duties Technical Specifications: 1. Location: Proposed Building of Sub Register Office at Periamedu, Chennai. No of Lift: One No. 3. Type of Lift: Gearless with Machine Room. 4. Capacity of Lift :13 Persons. (884Kgs) 5. Speed: 1.00 mtr / Sec 6. Type of Drive: Microprocessor based specific variable voltage variable frequency V3F with enhanced ride comfort and near zero leveling functions. VVVF Drive. 7. No of floor: Ground + 2 floors.8. Total Travel: 11 mtrs approximate 9. Leveling Accuracy: High level accuracy with smooth & Jerk free stopping. 10. Construction of car: Special car made of Stainless Steel hairline finish No.4 hair line finish & panels with Direct lighting and New Beautiful Single Tile false ceiling with Tubular Handrail and mirror. 11. Position of Machine: Directly above the lift well shaft gearless. 12. No. of Landing Entrance:
One in front - 3 Nos only. 13. No. of Car Entrance: One in front only. 14. Car Entrance Door: Centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel operated centre opening SS cars. 15. Landing Entrance Door: Centre opening automatic power door with stainless steel No.4 Hair Line finish with view panel Power operated V3F Drive Centre opening stainless steel No.4 Hair line finish with view panel . door with provision for emergency key opening at all landing.16. Car size: 2000 mm widex 1300mm deep (part 1) 17. Car clear Opening: 1000mm x2000mm (as per IS 14665 (part 1) -2000 (wide) x 2000mm Height. (as per IS 14665 (Part-I)-2000). 18. Lift well : 2480mm(width)x2080mm (depth) available size. 19. Lift pit depth available: 1600mm. 20. Power supply : 415V,400/440v, 3 phase, 50 cy / Sec A.C supply for power and 230V, 50 Hz single phase AC supply for light. 21. Control: Micro processor Computer based - simplex collective full collective logic system with or without attendant mode. 22. Car fittings:Indirect fluorescent light & Fan.
23. Lift Well: RCC construction with Brick masonry existing. 24. Lift Machine Room: As per standard specification 1800mm (Width) x 1500mm(depth) (as per IS 14665 (Part-5) - 2000) 25. Induction: Up / Down Digital Direction scroll type and position indicator for all landing and in car. 6. Emergency Alarm Bell: Battery Operated Alarm Bell to be provided with automatic charging device. 27. Emergency Light: Battery operated Light to be provided with automatic charging device. 28. Fireman's switch: To be provided at ground floor. 29. Minor Builders Work: To be provided by lift contractor. 30. Scaffolding: To be provided by lift Contractor. 31. Stainless Steel still angles and facia Plates: To be provided by lift contractor. 32. Steel for lift Machinery: To be Provided by lift contractor.2 33.Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarntee period of one year 34. Provision of 1+3 EPABX intercom with phone to be provided at the following places vide 1. Lift Head Room 2. Reception Room and 3. Inside the Lift by lift contractor.
All the features as per differntly abled persons act should be provided. 2 hours fire retardant landing doors. 35.Lift License: Preparation of drawing , payment of charges to CEIG and insurance policy if any and obtaining CEIG safety certificate and lift license as per lift act should be done by the lift contractor. 36. Automatic rescue device: To facilitate the landing of the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger inverter under voltage protection system etc.
GST at 18%
amman electricals (BID ID -1102879)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .