| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.6 L+₹30,760.40 (0.67%)Rejected-Finance MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹47.9 L+₹1.6 L (3.55%)Rejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹48.6 L+₹2.4 L (5.15%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹49.8 L+₹3.6 L (7.73%)Rejected-Finance | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹49.0 L
EMD Value
₹98,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR MAINTENANCE OF LT CABLE DISCIPLINE ROUTE INDICATOR LT FEEDER PILLAR BOX DISPLAY BOARD AT DIFFERENT LOCATION AT NAVAL STATION KARANJA
2024_MES_668128_1
8962/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹98,000
Yes
5 Nov 2024
30 Aug 2024
28 Sept 2024
30 Aug 2024
26 Sept 2024
12 Sept 2024
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : TPP 2024-2025 Ser No. 76 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Note :- The rate quoted is inclusive for the following :- (i) (a) Attending minor repairs/breakdowns without involving any new (major) materials. (b) Cost includes the tools for attending break down and minor materials like lugs and PVC tapes,Job Cards and Complaint registers etc. (c) Major repairs,Break downs invloving S&F of materials such as cables,Joints,MCCBs etc are out side the scope of this item and shall be measured and paid separately. (d) Contractor should ensure to carry out the work through qualified Technician/Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted.
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in any type of soil complete all as specified and directed.
Returning and filling in of excavated soil including spreading,levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete all as specified and directed. Note: Punned thickness only will be measured and paid
Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed.
M&L for GI pipe light grade 80 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed. .
M&L for cutting the tarmac / hard standings and excavating in trenches across the road for laying cable complete all as specified and directed.
M&L for PCC type C2, 1:3:6 using 40 mm gradded stone aggregate in foundations complete all as specified and directed.
Supply, laying & testing in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 25 Sqmm, 4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor including dismantling & taking out old cable complete all as specified and directed..
All as per BOQ Serial item No 1.11 above but 35 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 50 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 70 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 95 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 120 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 150 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 185 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 240 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 300 Sqmm 3.5 core
All as per BOQ Serial item No 1.11 above but 400 Sqmm 3.5 core
S&F in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed.
S&F in repairs ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed.
S&F in repairs 3 Pole MCCB 400 Amps, adjustable type,415V, 36KA rating complete all as specified and directed.
All as per BOQ Serial item No 1.24 above but 3 Pole MCCB 250 Amps, Adjustable type, 415 V, 36KA rating
All as per BOQ Serial item No 1.24 above but 3 Pole MCCB 200 Amps, Adjustable type, 415 V, 36KA rating
All as per BOQ Serial item No 1.24 above but 3 Pole MCCB 160 Amps, Adjustable type, 415 V, 36KA rating
All as per BOQ Serial item No 1.24 above but 3 Pole MCCB 125 Amps, Adjustable type, 415 V, 16KA rating
All as per BOQ Serial item No 1.24 above but 3 Pole MCCB 100 Amps, Adjustable type, 415 V, 16KA rating
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB 630 Amps, 415 V, Microprocessor release with breaking capacity 50 KA
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB 400 Amps, 415 V, Microprocessor release with breaking capacity 36 KA
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB 250 Amps, 415 V, Microprocessor release with breaking capacity 36 KA
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB 200Amps, 415 V, Adjustable type with breaking capacity 36 KA
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB 160 Amps, 415 V, Microprocessor release with breaking capacity 36 KA, 160 A rated
All as per BOQ Serial item No 1.24 above but 4 Pole MCCB160 Amps , 415 V, Adjustable type with breaking capacity 36 KA
S&F in repairs Isolator 415 Volts 4 pole, 63 Amps current carrying capacity complete all as specified and directed.
All as per BOQ Serial item No 1.36 above but 4 Pole 100 Amps
All as per BOQ Serial item No 1.36 above but TPN 63 Amps
All as per BOQ Serial item No 1.36 above but TPN 100 Amps
M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes complete all as specified and directed. Note: - (i) The rate quoted deemed to be inclusive of transportation of equipment and charges for service engineer . (ii) The fault locator will be arranged by Contractor Only
M&L for heat shrinkable straight through joint for LT UG cable including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 25 to 50 sq.mm complete all as specified and directed. .
All as per BOQ Serial Item No. 1.41 above but for cable of size 3.5 core 95 to 120 sq.mm.
All as per BOQ Serial Item No. 1.41 above but for cable of size 3.5 core 150 to 185 sq.mm.
All as per BOQ Serial Item No.1.41 above but for cable of size 3.5 core 240 to 300 sq.mm.
M&L for heat shrinkable Termination Kit (with colour limbs of Red, Yelllow, Blue & Black) for LT UG cable complete for making serviceable for aluminium conductor cable of size 3.5/ 4 core 50 to 95 sq.mm complete all as specified and directed.
All as per BOQ Serial Item No.1.45 above but for cable of size 3.5 core 120 to 185 sq.mm.
All as per BOQ Serial Item No.1.45 above but for cable of size 3.5 core 240 to 300 sq.mm.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 25 x 4mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate), "mild steel angle iron frame" made out of MS angle iron of size 40x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion including retrieving old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed. Note : (i) The unit rate includes for protection pipe and GI strip from top of earth plate up to 7.5 meter above ground level and also the cost of the Test point. (ii) Joining of GI earth strip with pipe of the test point shall be done by using suitable cable lugs.
Supply and lay Graded coarse aggregate of size 40 mm dia size upto height of 0.15 Mtr over 0.1 Mtr of sand cushioning in outdoor sub-station yards including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50 m before laying of complete all as specified and directed.
S&F in repairs display board (as per sample kept in AGE E/M office) on different sub stations alongwith necessary paintings to existing Pole and display Board (minimum size 900 x 600mm) complete all as specified and directed.
S&F in repairs LT Cable CI path indicator of size 80 x 50 x 05mm having voltage written on it as 415V painted with Blue colour welded with MS angle iron to be erected 20cm above ground and 20cm below the ground with PCC 1:2:4 cubical size of 20 x 20 x 15 cm with necessary exavation, returing filling complete all as specified and directed
S&F in repairs HT Cable CI path indicator of size 80 x 50 x 05mm having voltage written on it as 22000V painted with Brown colour welded with MS angle iron to be erected 20cm above ground and 20cm below the ground with PCC 1:2:4 cubical size of 20 x 20 x 15 cm with necessary exavation, returing filling complete all as specified and directed
S&F tringular shape of 3mm sheet metal indicator of size 30 x 45 x 54 cm mounting on flat GI strip of size 32 x 10 mm from 120cm above ground with suitable PCC 1:2:4 for foundation of 15x15x10cm for showing route of LT/HT cable with and including all fixing and painting of suitable size letter omplete all as specified and directed
M&L for Maintenance and attending complaints / breakdowns at Naval Station Karanja area comprising of LT panels, over head lines/ underground LT cables upto main distribution boards at buildings including repairs of day to day maintenance of LT panels by providing necessary hinges, nuts & bolts, welding and painting at site to LT Panels where necessary for smooth & trouble free LT power supply including rectification of minor defects to electrical controls gear/accessories complete all as specified and directed.
ECOBUILD (BID ID -3097839)
Om Sai Enterprises (BID ID -3098539)
Sagar Electricals (BID ID -3098528)
R A Electric Co. (BID ID -3096541)
SREE HARITHA ASSOCIATES (BID ID -3097359)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .