| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹4.9 L (4.26%)Admitted-Finance 4 3 OPP WADALA TELEPHONE EXCHANGE NEW MUNICIPAL BUILDING NAIGAON MUMBAI MAHARASHTRA 400014 | MUMBAI | MAHARASHTRA | 400014 | ₹1.2 Cr+₹4.9 L (4.26%) | L2 | Admitted-Finance |
| 3 | L3₹1.5 Cr+₹37.4 L (32.8%)Admitted-Finance | ₹1.5 Cr+₹37.4 L (32.8%) | L3 | Admitted-Finance |
| 4 | L4₹1.5 Cr+₹37.9 L (33.2%)Admitted-Finance VOLTAS HOUSE B 2ND FLOOR T B KADAM MARG CHINCHPOKLI MUMBAI 400 033 | MUMBAI | MUMBAI | MAHARASHTRA | 400033 | ₹1.5 Cr+₹37.9 L (33.2%) | L4 | Admitted-Finance |
| 5 | L5₹1.5 Cr+₹38.5 L (33.7%)Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹1.5 Cr+₹38.5 L (33.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TEMPCON ELECTROMECH SYSTEMS L2 | BRITE INDUSTRIES L3 | Bluestar Limited L5 | NU DYNA ENGINEERS PRIVATE LIMITED L1 | VOLTALIMITED L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00Day to day opertation and Quartely maintenance including overhauling & breakdown maintenance of cooling towers of 200 TR capacity each as described below for a period of 36 months as per technical specification. | ||||||||
| 1.10 | Quarterly maintenance including day to day operation, servicing, preventive & breakdown maintenance of two nos. of Cooling Towers of 200 TR capacity each as per sub clause no. 1.1 of specifications. | 20 | Nos | 8,000 ₹1,60,000 Lowest | 8,907 ₹1,78,140 | 20,000 ₹4,00,000 | 39,200 ₹7,84,000 | 18,900 ₹3,78,000 |
| 1.20 | Overhauling of cooling towers once in 18 months as per sub clause no. 1.2 of specifications. | 4 | Nos | 20,000 ₹80,000 | 8,907 ₹35,628 Lowest | 10,000 ₹40,000 | 70,000 ₹2,80,000 | 40,000 ₹1,60,000 |
| 1.30 | Replacement of cooling tower motor with brand new one of capacity 7.5 HP and 700 RPM as per sub clause no. 1.3 of specifications. | 1 | Nos | 85,000 ₹85,000 | 32,760 ₹32,760 | 66,500 ₹66,500 | 60,000 ₹60,000 | 12,500 ₹12,500 Lowest |
| 1.40 | Replacement of existing defective fills of 2 Nos 200 TR cooling tower with new PVC Honeycomb fills approx total volume 14 M^3 as per sub clause no. 1.4 of specifications. | 1 | Lot | 1,30,000 ₹1,30,000 | 99,450 ₹99,450 | 1,40,000 ₹1,40,000 | 1,50,000 ₹1,50,000 | 65,000 ₹65,000 Lowest |
| 1.50 | Replacement of drift eleminator, suitable for cooling tower of capacity 200 TR as per sub clause no. 1.5 of specifications | 2 | SET | 15,000 ₹30,000 | 14,040 ₹28,080 | 10,000 ₹20,000 Lowest | 50,000 ₹1,00,000 | 55,000 ₹1,10,000 |
| 2.00Day to day opertation and Quarterly maintenance including overhauling & breakdown maintenance of Air Handking Units (AHU) of 4000 cfm, 10 TR Capacity each as described below for a period of 36 months as per clause - 2.0. of technical specification. | ||||||||
| 2.10 | Quarterly maintenance including day to day operation, servicing, preventive & breakdown maintenance of 23 nos. of AHUs of 4000 cfm, 10 TR Capacity each as per clause No. 2.1 of technical specifications. | 230 | Nos | 6,000 ₹13,80,000 | 8,374 ₹19,26,020 | 17,730 ₹40,77,900 | 5,600 ₹12,88,000 | 4,650 ₹10,69,500 Lowest |
| 2.20 | Overhauling of the AHUs once in 18 months as per clause No. 2.2. of technical specifications. | 46 | Nos | 12,000 ₹5,52,000 | 8,907 ₹4,09,722 | 2,000 ₹92,000 Lowest | 7,000 ₹3,22,000 | 10,000 ₹4,60,000 |
| 2.30 | Replacement of Pullys for blower of 10 TR capacity Air Handling Units as per clause 2.3 of technical specifications | 21 | Nos | 3,000 ₹63,000 | 1,404 ₹29,484 Lowest | 4,000 ₹84,000 | 5,000 ₹1,05,000 | 7,000 ₹1,47,000 |
Tender Value
₹1.6 Cr
EMD Value
₹3.7 L
Closing Date
30 Dec 2024, 6:00 pmClosed
C.E. and Head, Technical Services Division
Head, Technical Services Division, BARC, Trombay, Mumbai-400085
Maintenance of HVAC System and miscellaneous work at Super computing facility, SBI building and Helium plant for a period of 36 months at BARC, Trombay, Mumbai -85.
2024_BARC_837816_1
BARC/TSD/ET/41/2024-2025
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
1095 days
BARC, TROMBAY, Mumbai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹3.7 L
Yes
TSDBARC, Trombay, Mumbai
20 Feb 2025
5 Dec 2024
7 Jan 2025
5 Dec 2024
30 Dec 2024
5 Dec 2024
5 Dec 2024 - 20 Dec 2024
17 Dec 2024
Amount
Day to day opertation and Quartely maintenance including overhauling & breakdown maintenance of cooling towers of 200 TR capacity each as described below for a period of 36 months as per technical specification.
Quarterly maintenance including day to day operation, servicing, preventive & breakdown maintenance of two nos. of Cooling Towers of 200 TR capacity each as per sub clause no. 1.1 of specifications.
Overhauling of cooling towers once in 18 months as per sub clause no. 1.2 of specifications.
Replacement of cooling tower motor with brand new one of capacity 7.5 HP and 700 RPM as per sub clause no. 1.3 of specifications.
Replacement of existing defective fills of 2 Nos 200 TR cooling tower with new PVC Honeycomb fills approx total volume 14 M^3 as per sub clause no. 1.4 of specifications.
Replacement of drift eleminator, suitable for cooling tower of capacity 200 TR as per sub clause no. 1.5 of specifications
Day to day opertation and Quarterly maintenance including overhauling & breakdown maintenance of Air Handking Units (AHU) of 4000 cfm, 10 TR Capacity each as described below for a period of 36 months as per clause - 2.0. of technical specification.
Quarterly maintenance including day to day operation, servicing, preventive & breakdown maintenance of 23 nos. of AHUs of 4000 cfm, 10 TR Capacity each as per clause No. 2.1 of technical specifications.
Overhauling of the AHUs once in 18 months as per clause No. 2.2. of technical specifications.
Replacement of Pullys for blower of 10 TR capacity Air Handling Units as per clause 2.3 of technical specifications
Replacement of Pullys for motor of 10 TR capacity Air Handling Units as per clause 2.5 of technical specifications
Day to day opertation and Quarterly maintenance including overhauling & breakdown maintenance of 17 nos. of water cooled Package air conditioners (PAC) as described below for a period of 36 months as per clause - 3.0. of technical specification.
Quarterly maintenance including day to day operation, servicing, preventive & breakdown maintenance of 17 nos. of Package units of 11 TR capacity each as per clause - 3.1 of technical specification.
Overhauling of the Package units once in 18 months as per clause - 3.1 of technical specification.
Repair of electronic controller of package air conditioners as per clause 3.3 of technical specifications
Replacement of Pullys for blower of 11 TR capacity package air conditionioners as per clause 3.4 of technical specifications
Replacement of Pullys for motor of 11 TR capacity package air conditionioners as per clause 3.5 of technical specifications
Replacement of compressors for package units as per clause 3.6 of technical specifications
Monthly Cleaning of all equipments and sorrounding area with all required materials for cleaning in AHU rooms, pumps rooms and cooling tower room etc. as per clause No. 4.0 of Technical Specification.
Comprehensive maintenance including Breakdown maintenance of the following equipments as per clause no. 5.0 of technical specifications.
Overhauling, caliberation of Pressure independent balancing and control valve (PIBCV) with actuator, once in contract period
Overhauling, caliberation of Electro magnetic flow meter once in contract period
Overhauling, caliberation of Ultrasonic flow meter once in contract period
Overhauling, caliberation of RTD, once in conract period
Supply, fabrication & installation of GI ducting to be fabricated out of 20 gauge (1.0 mm) thick 220 GSM GI sheet complete with suitable supports as per clause no. 6.0 of tender specification and instruction of EIC. NOTE : 1) Structural steel required for installation of GI ducting shall be paid separately under item MS structure. 2) Removing & refixing of false ceiling tiles and replacing false ceiling tiles damaged during erection of ducting, damper etc., if any, shall be in the scope of this item.
Supply, installation, testing and commissioning of Class-O closed cell nitrile rubber thermal insulation along with aluminium cladding on air-conditioning ducting/Piping with accessories at various locations as per clause no. 7.0 of tender specification and instruction of EIC.
Supply & installation of Manually operated opposed blade operation having Aerofoil double skin blade design damper made of GI sheet. (size will be as per site requirements) as per clause no. 10.0 of tender specification and instruction of EIC. as per clause no. 8.0 of tender specification and instruction of EIC.
Day to day operation and maintenance including overhauling & breakdown maintenance of 2 nos. of horizontal split casing Centrifugal condenser water pumps of 748 GPM (170 M^3/hr) capacity having 30 m head and 2 Nos of chilled water pumps of 690 GPM(159 M^3/hr) capacity having 25 m Head as described below for a period of 36 months as per clause - 9.0. of technical specification.
Quarterly maintenance including daily operation, preventive and break down maintenance of 4 nos of Centrifugal Pumps as mentioned above and as per sub clause no. 9.1 of technical specification.
Overhauling of above mentioned 4 nos of Centrifugal Pumps once in a contract period of 36 months as per sub clause no. 9.2 of technical specification.
Day to day operation and maintenance including overhauling & breakdown maintenance of 8 nos. of Centrifugal verticle inline pumps motor set as described below for a period of 36 months as per clause - 10.0. of technical specification.
Quarterly maintenance including daily operation, preventive and break down maintenance of 8 nos of Centrifugal Pumps as mentioned above and as per sub clause no. 10.1 of technical specification.
Overhauling of above mentioned 8 nos of Centrifugal Pumps once in a contract period of 36 months as per sub clause no. 10.2 of technical specification.
Quarterly maintenance including overhauling & breakdown maintenance of 8 Nos. of pot strainer as per clause no. 11 of tender specifications.
Quarterly maintenance including overhauling & breakdown maintenance of 6 nos. of Y strainer as per clause no. 12 of tender specifications.
Quarterly maintenance including overhauling & breakdown maintenance of 9 nos. of Basket Filter as per clause no. 13 of tender specifications.
Maintenance, overhauling & breakdown maintenance of 17 nos. of Non Return Valves as per clause no. 14 of tender specifications.
Removal of existing corroded pipes and supply, installation, testing and commissioning of Class-C (heavy as per IS:1239) G.I. piping for chilled water lines along with all requird accessories & pipe fittings, flanges etc. with 25mm thick nitrile rubber thermal insulation of class 'O', high density puf gutty with aluminium cladding etc. as per clause no. 15 of tender specifications. (Pipe sizes are ranges from 2 inch NB to 8 inch NB, class heavy, as and when required)
Supply, installation, testing and commissioning of following agents required for maintenance of mechanical systems
Anti slippage belt dressing (DRIVE BELT DREZING) 500 ML pack
Penetrating oil for loosening rusted components (PEN OIL) 500 ML pack
SS Coating containig pure SS 316L Pigments (SS KOTE) 500 ML pack
RUST CONVERTER Coating 5 KG pack
Single Pack Chemical Resistant coating (CHEMPRO CRC 29) 5 LTR pack
Steel-Filled Epoxy Putty - SG (S PUTTY SG) 1 KG pack
REINFORCEMENT TAPE ( 50mm X 50 m) 1 ROLL pack
Supply & replacement of defective V-Belts with with new ones as described below as per clause no. 17 of tender specification.
A32 (Package)
Supply and installation of following Bearings of SKF or equivalent make complete with all required materials and works as per clause no. 18 of tender specification.
Housing No. NTN P-205, Eccentric locking collar. For package units or approved equivalent
SKF 6309 zz for Pumps or approved equivalent
7309BE or approved equivalent
6309.Z.C4 or approved equivalent
7308BE.2CS for helium plant pump and SCF process pump or approved equivalent
6206.2Z.C3 for helium plant pump and SCF process pump or approved equivalent
RCSM-25 or approved equivalent for all AHUs
Supply and Replacement of old deteriorated hardware as described below as per clause no. 19 of tender specification.
SS Nut bolt with washer M10 X 50mm.
SS Nut bolt with washer M12 X 70mm.
SS Nut bolt with washer M14 X 70mm.
SS Nut bolt with washer M16 X 80mm.
SS Nut bolt with washer M18 X 80mm.
SS Nut bolt with washer M20 X 150mm.
Supply & Replacement of defective/worn out Air filters of AHU & Package air unit with new ones as described below as per clause No. 20.0. of technical specification,
3 ply HDPE washable filter of approx 430 mm X 420 mm size and 50 mm depth for AHU as per sample given by department.
2 Ply, HDPE washable pre filter of approx 515mm X 825 mm. size and 8 mm thick for Package units,
Supply and application of Chemicals as described below and as per clause - 21.0. of technical specification.
Chemical cleaning of cooling coil, filters, blowers and other HVAC components.
Periodic dosing of Algaecide Chemical in cooling tower to prevent growth of algaes as instructed by EIC.
Comprehensive maintenance of 3 no. of plant type heat exchangers as per OEM for the Heat exchangers as per clause no. 22.0 in technical specifications.
Heat exchanger of GEA Ecoflex make of capacity 300 KW
Heat exchanger of Ecoflex make of capacity 300 KW
Heat exchanger of ALFA Laval make of capacity 243 KW
Removal, dismantling, seperation of insulation and shifting of old deteriorated / defective ducting with all accessories from various site locations to scrap point as per clause no. 23 of tender specification.
Removal, dismantling, seperation of insulation and shifting of old pipe line dia with suporting structure, & associated equipment from various locations as per clause no. 24 of tender specifications.
Repairing by only welding of pipes and structural material complete with final run at site as per clause no. 25 of tender specification.
Replacement, Supply, installation of various MS supports and other accessories including removing old items as per clause no. 26 of tender specification.
Scraping, cleaning and painting of metallic body/supports, civil structure/surfaces at various locations at SCF/ Helium plant/ SBI Building/ ModLabs / BARC as described below and as per clause no. 27 of tender specification.
Painting on Metallic surface.
Painting on cement plaster surface.
Supply and installation of TF quality 50 mm thick thermocol insulation in pipe section along with suitable vapour barrier,cement plaster and paintingas per clause no. 28 of technical specifications
Providing, supplying Pick-up Van/Utility van of five seaters with the back side provision for transporting/shifting of various maintenance materials and escorting person inside BARC and for other works including Driver on all working days and saturdays for a period of 36 months.
Excavation as described below and as per clause no. 29 of tender specification.
Excavation of soft/hard soil.
Excavation of PCC/RCC/Rock.
S.I.T.C of RCC as per clause no. 30 of tender specification.
Replacement, Supply, installation, Testing and Commissioning of Single stage, Split casing, Centrifugal pump with VFD enabled motor and other accessories including removing old items as per clause no. 32 of tender specification.
Split casing Centrifugal Pump of capacity 150 CMH & Head 25 m of WC
Split casing Centrifugal Pump of capacity 170 CMH & Head 30 m of WC
TEMPCON ELECTROMECH SYSTEMS (BID ID -3145162)
BRITE INDUSTRIES (BID ID -3145853)
VOLTALIMITED (BID ID -3146862)
Bluestar Limited (BID ID -3146953)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 14.95 MB
TenderDocument.pdf
Tender Documents • 2.95 MB
ScheduleA.pdf
Tender Documents • 0.77 MB
BOQ_880595.xls
BOQ • 0.26 MB
TechSpec.pdf
Tender Documents • 0.85 MB
TECHNICAL_BID_BARC_TSD_ET_41_2024_2025.xls
Tender Documents • 0.27 MB
ProformaAtoF.pdf
Tender Documents • 0.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .