Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹6.5 L
Closing Date
17 Jul 2026, 11:30 am
Similar tender results from the same govt authority in the past 3 years.
Hyderabad Division: 1:Provision of CCTV cameras at 9 MMTS stations (ie, LGDH, DYE, SFX, RKO, AMQ, ALW, BOZ, GWV and NSVP) over Hyderabad Division, 2)Provision of Video Surveillance at Different Locations at Railway Stations and Provision of Video Recording at Relay Room/Station Master Room Provision of Video Recording System in 67 Relay Room, 67 Station Master Room over Hyderabad Division.
Y-SG-36-2026-27-09
Y-SG-36-2026-27-09
Open
12 Months
Hyderabad, Telangana
₹0
₹6.5 L
23 Jun 2026
23 Jun 2026
3 Jul 2026
Item Breakup - A-Schedule -A
Supply of UTP CAT 6A Cable (Roll is 305 Mtr) Metre of D.LINK/AMP/KRONE/ NOTOFIRE or Better make (INSPECTION: CONSIGNEE)
Supply of IP based day and night 8MP or high Numbers resolution camera spec with IP 66 rated water proof, dust proof for outside application with RDSO SPEC. RDSO/SPN/TC/65/2021 ver. 6 or latest with STQC Certification ( INSPECTION: RDSO)
Supply of 6TB internal hard disc 10000 RPM Numbers or higher with power and SATA data cables suitable for 16/32/64 channel super NVR. Make: HP/Dell/ Seagate or better ( INSPECTION: CONSIGNEE)
Supply of 10TB internal hard disc 10000 RPM Numbers or higher with power and SATA data cables suitable for 16/32/64 channel super NVR. Make: HP/Dell/ Seagate or better. ( INSPECTION: CONSIGNEE)
Supply of Permanently lubricated HDPE Duct Kilometre with outer diameter of 40mm and inner diameter of 33mm as per specification RDSO/SPN/TC/45/2013 Revision 2.0. The length of the duct shall be 1km. Two end plugs shall be provided along with the drum. (INSPECTION:RITES)
Supply of 32 Channel 4 SATA NVR, Numbers supporting up to 72GB total storage and recording resolutions up to 12MP with 4K HDMI output, 512Mbps throughput simultaneous playback of up to four 4K, ten 3MP, or sixteen 1080p streams at 30FPS along with recording, ONVIF profile S and SDK, Server-less centralized control & mobile live view of multiple NVR clusters (INSPECTION:CONSIGNEE) Total 12111042.00
Item Breakup - B-Schedule -B
Supply and installation and commissioning of Numbers 100% copper winding Servo voltage stabilizer 5 KVA, single phase, servo controlled, 140V-300V range voltage stabilizer as per Annexure XVII ( INSPECTION: CONSIGNEE)
Supply and fixing of different sizes of PVC RMT casing/Pipes as required by Rly at site by fixing /clamping to the wall for indoor wiring purposes. All the material required for fixing PVC casing/Pipes are to be supplied by contractor ( INSPECTION: CONSIGNEE)
Supply and installation of 19" - 42U Supply Numbers and installation of 19' - 42 U Rack complete with bfittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be of APW President / Rittal make or similar. The components of the rack are specified below. It includes transportation and installation of rack in prefab/building at specified stations. 1. Rack S33 42U 600W x 600D - 1 No. 2. Fixed side panels 42U x 600 o - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5. Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 Nos. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs(DP)- 2 Nos. & 6Amps MOBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos" ( INSPECTION: CONSIGNEE)
Excavation of trench, Depth of 1200mm and RMT width of 300mm , including marking of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer incharge.
Blowing of armoured optic fibre cable (OFC Kilometre Cable supplied by Railways) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.
Supply & Laying of G.I Pipes with medium RMT and threaded collar & coupler, quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS 4736-1986.(a) G.I Pipes of 50mm diameter ( INSPECTION: CONSIGNEE) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply and installation of STQC certified Numbers ONVIF 4MP or better as per spec. RDSO SPEC. RDSO/SPN/TC/65/2021 ver.6 or latest ( Supply portion INSPECTION: RDSO)
Installation and commissioning charges Numbers (installation and configuration for video ip camera
Laying of HDPE duct 40/33 mm dia in the Kilometre trenches and in protective works already provided. Total 6314915.00
Item Breakup - C-Schedule -C
supply of 4 way Spike busters with 5 mtrs Numbers power cable within dividual switch And Fused foreach socket 5A reputed make. NAX./ better (INSPECTION: CONSIGNEE)
Supply of 10 Steps Double Telescopic Numbers Aluminum Ladder with Adjustable Hight as per the instructions of Engineer-incharge. (INSPECTION: CONSIGNEE)
Supply of 55 Inch Professional display with Numbers HDMI-3 nos, DP-2 nos USB,LAN DVI, 20 W, 500 nit, Anti glare, Auto Input search, Auto sleep, Auto wakeup. licence Make: LG/sumsung/sony or better As per specification RDSO/SPN/TC/65/2021 . (INSPECTION: CONSIGNEE)
Supply of RJ-45 Jacks and Termination with Numbers CAT-6 cableMake: D-Link.or better (INSPECTION: CONSIGNEE)
Supply of 12 fibre Single mode armoured Metre optical fiber cable - fibre to have nominal dia. of 8.8 m to 9.8 m and normal cladding diameter of 125 m ± 1 or better. As per RDSO Spec No.IRS: TC 55 2006 (Rev.1.0) Amendment.3 or latest .(INSPECTION: CONSIGNEE)
Supply of 10/100 Mbps single mode media Numbers converter with accessories including connecting cables. As per specification RDSO/ SPN/TC/103/2013.(INSPECTION: CONSIGNEE)
Supply of HDMI Aten 3 mtrsCable M/M 30 Numbers AWG Gold Black.(INSPECTION: CONSIGNEE)
Supply of HDMI Cable 10 Mtrslength with Numbers Male-Female/Female-Female/Male-Male) moulded typeas required at site. Make: MX/ATEN/Dyeton or better.(INSPECTION: CONSIGNEE)
Supply of 8 Port PoE Switch as per Numbers specification given in RDSO spec RDSO/SPN/TC/65/2021 ver. 6 or latest (INSPECTION: CONSIGNEE) Total 2345333.36
Item Breakup - D-Schedule -D
Supply and fixing of SC-LC/LC-LC patch Pair cards(1mtr length) with OdB adaptors as per TEC spec G/OJC- 01/03 JAN 99 or latest make Make:3C3/legrand/ comscope/NOTOFIRE or better (INSPECTION: CONSIGNEE) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply & installation of 5 KVA True On Line Numbers UPS, with surge protection filter with floor mounting with 4 hours Backup with 6 Nos of 12V-100Ah MF batteries as per specification IEC 62040-1 (INSPECTION: RITES)
Supply and fixing/laying of25mm dia 2mm RMT thick PVC pipe(Sudhakar/Nandi/SR make) duly groving concealed in the walls .All the required accessories such as Deep boxes, Jn Boxes, Normal bends, diversion bends etc are to be arranged by the contractor. (INSPECTION: CONSIGNEE)
Supply and fixing/laying of 40mm dia 2mm RMT thick PVC pipe(Sudhakar/Nandi/SR make) dulygroving concealed in the walls.All the required accessories suchas Deep boxes, Jn Boxes,Normal bends, diversion bendsetc are to be arranged by the contractor. (INSPECTION: CONSIGNEE)
supply & fixing of PVC Flexible pipe of Metre 25/40/50mm dia sizes of reputated make Sudhakar/Nandi/SR make or better. (INSPECTION: CONSIGNEE)
Supply & fixing of 9U rack with locking front Numbers glass door and fully vented rear steel door, compatible with standard 19"accessories, top cover with gland plate and fan, with rack cagenuts and screws, fan assembly kit, rack mount shelves, Power manager., etc this includes wiring as & Water proof arrangements per the instruction of site incharge. Make: HCL/ Veropresident/bestnet or better. (INSPECTION: CONSIGNEE)
Cutting of trench across/on the platform with RMT cutting Machine asper site requirements for laying the cable through PVC/GI pipe and filling the trench after cable laying and restoring the surface with same/proper materials etc. and as per instructions of site incharge.
Laying of PVC switch board cables /CAT6/ Metre power /OFC-6F/12F cables in the PVC casing/PVC pipes as per the instruction of site incharge.
Supply and installation of 1GBPS Media Numbers Converter as specified by supervisor in- charge with 2 optical port RDSO/ SPN/TC/103/2013 (INSPECTION: CONSIGNEE)
Supply and Fixing of IO Boxes make D- Numbers Link/HCL/Bestnet or better. (INSPECTION: CONSIGNEE)
Supply & laying of CAT-6 cable Patch Cards - Numbers 2 Mtrs length with RJ -45 Jacks on both ends. Make:D-Link/Bestnet or better.(INSPECTION: CONSIGNEE)
Supply commissioning of ONVIF 2SATA 16 channel NVR, supports upto 36TB, supporting recording resolutions up to 12MP and 4K HDMI output for ultra-clear monitoring. 360Mbps total throughput . simultaneous playback of up to two 4K or eight 1080p streams at 30FPS alongwith recording, ONVIF profile S and SDK, Server-less centralized control & mobile live view of multiple NVR clusters (INSPECTION:CONSIGNEE) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply and laying of SC-PC to SC-PC patch Pair cords(5mts length)with 0dB adaptors as per TEC spec G/OJC-01/03 Jan 99 or latest as per Specification RDSO/ SPN/TC/ 71/2008 . (INSPECTION: CONSIGNEE)
Supply and installation of rack mounted 12F Numbers FMS or better fiber part no.fms-1u 12FS 12FP Raychem make including 12Nos 0.2db SC/PC adaptors and 12 numbers900 micron 1.5 meter SC pigtails. (INSPECTION: CONSIGNEE)
Supply and installation of 10 Port Smart Numbers Managed Switch with 8x Gigabit Copper and 2x Gigabit dual port., hybrid mode, standalone or Nebula Flex Cloud, 130 Watt PoE, fanless (or latest) RDSO/SPN/TC/65/2021 or latest (NSPECTION: CONSIGNEE)
Supply & installation of 2KVA True On Line Numbers UPS, with surge protection filter including all accessories as per specification IEC 62040-1 (INSPECTION: RITES)
Supply and installation of 26AH/12V- 4 Nos Numbers SMF batteries for backup for above 2 KVA on line UPS system (Make: Amaron Quanta/Exide/HBL or better) a l o n g with battery inter linking cables. (INSPECTION: RITES)
Supply and installation of MS stand, inter Numbers connectors for above 2 KVA on line UPS system batteries (INSPECTION: CONSIGNEE)
Supply and installation of RJ-45 Jacks and Numbers Termination with CAT-6 cable. Make: D- Link/Bestnet or Better (INSPECTION: CONSIGNEE) Total 11452203.06
Item Breakup - E-Schedule- E
Supply and installation of 4G/5G SIM LAN Numbers Router TP Link/CP Plus/Hi Focus or better (INSPECTION : CONSIGNEE ) Total 138000.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
GCCcorrectionSlip1to10_1.pdf GCC Correction Slip 1 to 10
ATTACHMENT
GCCCorrectionSlipNo.11_1.pdf GCC Correction Slip 11
ATTACHMENT
MakeinindiaPolicy1_1.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
Experience.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
TD-09.pdf
ATTACHMENT
BankGuaranteee-
ATTACHMENT
GCCcorrectionSlip1to10_1.pdf
ATTACHMENT
GCCCorrectionSlipNo.11_1.pdf
ATTACHMENT
Acceptanceofe-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
Download all tender documents and submit your bid