Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC ACCEPTANCE | |
| 2 | L2₹31.4 L+₹1.5 L (5.03%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹33.8 L+₹3.8 L (12.8%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹37.0 L+₹7.1 L (23.7%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹41.3 L+₹11.4 L (38.1%)Rejected-Finance | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹38.4 L
EMD Value
₹78,800
Closing Date
22 Jan 2024, 6:00 pmClosed
COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR REPLACEMENT OF HT OVERHEAD FEEDER TO HT UG CABLE FROM KIRTI ENCLAVE TO VARUNAPURI FEEDER AND CONNECTED WORKS UNDER GE (NW) VASCO
2024_MES_635288_1
85757/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
as per tender document
9 documents required · 9 mandatory
₹500
GE (NW) VASCO
₹78,800
Yes
20 Mar 2024
1 Jan 2024
24 Jan 2024
1 Jan 2024
22 Jan 2024
15 Jan 2024
Amount
Supply, install ,testing and commissioning SF6 insulated compact Outdoor type R.M.U. rated voltage 11 KV,rated current 630 A, short circuit breaking current 16 KA and making capacity 40 KA ,fully arc proof metal enclosed, free standing, floor mounting, flush fronted type consists of Electrically operated non draw out type SF6 module-2 Nos load break switches (Incomers) and 2 No. Vaccum circuit breaker (outgoing) with integrated relays and related CTs as specified below, cable switch module and an interlocking mechanism with the earthing switch all as specified and directed. Degree of protection shall be per manufacturer specifications. (a) Fixed type voltage indicators and electronic short circuit indicators for simple fault indication (b) Resin cast CT with ratio 50-100/1A with 2.5VA burden class0.5 for metering and class 5 P10 for protection-Set of three (c) Resin cast potential transformers with ratio 11KV/1.732, 110V/1.732, 50 VA class1 with HT fuses mounted on with drawable rack (d) Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply (e) Trip circuit supervision relay (f) Power pack equipment , with back up for 15minutes including batteries complete suitable for operation of relays (g) Internal bus earthing with flat GI strip of size 50x6mm
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr depth for laying UG cable getting getting out in hard/dense soil complete all as specified and directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil excavated material to a distance not exceeding 50 Mtr above the starting point complete all as specified and directed.
M&L for XLPE insulated , armoured heavy duty electric cable with aluminum conductor, 11000 Volts grade, cross sectional area 95 Sqmm 3 core complete all as specified and directed.
M & L for Earthing complete with galvanised iron plate 600×600×6 mm thick buried directly in ground earth pit not less than 2.25 metres deep below normal ground level with top edge of the plate not less than 1.5 metres below normal ground level connected to GI strip size 32x6 mm thick by means of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary exacavation and earth work, GI pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 40 mm dia up to 7.5 Mtr from the earth plate electrode and refilling of soil including adeqate quantity of charcoal dust and comman salt etc & earth work in any strata, PCC pit chamber in cement mortar1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-In-Charge. Location : - 02 Nos at NUWR sub stn & 04 Nos at 33 KV at MRS NOFRA.
S & F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S & F cable end termination kit cold shrinkable indoor type, suitable for XLPE cable 3 core 95 Sqmm 11 KV HT supply complete all as specified and directed.
Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. Complete as specified and directed.
RAVINDRA BROTHERS
DURGAI ELECTRICALS
ANKIT SHIP REPAIRERS AND SUPPLIERS
Shine Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .