| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹38.8 L+₹1.3 L (3.56%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹39.6 L+₹2.1 L (5.63%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹40.4 L+₹2.9 L (7.76%)Rejected-Finance VIJAY NAGAR KUMHARTOLI HANSARI INFRONT OF JIGYASA INTER COLLEGE JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹41.6 L+₹4.1 L (10.9%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
PROVN OF CERTAIN SPECIAL REPAIR WORK AND MINOR WORKS AT AGE B/R-I, AGE B/R-II AND AGE E/M AT BABINA
2023_MES_602588_1
8155/E8
Open Tender
Civil Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹94,000
Yes
21 Sept 2023
10 Jun 2023
22 Jul 2023
10 Jun 2023
20 Jul 2023
6 Jul 2023
Amount
Dismantling of Asbestos cement ( corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any guage, thickness includidng nainital or similar pattern in roof covering complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zink coating GI based corrugated steel 0.50mm thick and AZ- 150 of any colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self tapping screw complete all as specified and as directed.
S & F Pre- painted galvalume aluminum zink coating GI based plain steel 0.50mm thick and AZ- 150 of any colour having tensile strength of 550mpa as in roof covering/clading to wall, fixed with self tapping screw complete all as specified and as directed.
Dismantling timber scantling unframed work 40 sq. cm and over in section in any position complete all as specified and as directed.
M&L for Second class hard-wood (SAL wood) in scantlings, wrought timber frame and fixed in position (As a truss member or in Rafter in roofing work) etc complete all as specified and as directed.
Taking down and Re-Fixing include Erection of Roof trusses (framed), trusses, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M&L mild steel work in hand rails, half round or other steel section or core for Wind ties for roof including securing bolts, post and struts cutting tops to shape as directed, drilling holes, notching for wire etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer, over 10cm in width or girth,not otherwise described complete all as specified and as directed.
M&L for preparation of old steel surfaces and applying one coat of synthetic enamel paint over a coat of red oxide primer, over 10cm in width or girth,not otherwise described complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pump, insulation etc,) or insulation boards of any thickness including cover fillets complete all as specified and as directed.
M&L for aluminium anodised snap grid frame work of the following (a) Main Tee section 36.5x25x1.4mm size (wt not less than 0.24Kg/RM) (b) Section alongwith wall angle of size 40x25x2mm size (wt not less than 0.36Kg/RM) (c) Cross Tee section 23.5x26.4x1.4mm size (wt not less than 0.191Kg/RM) (d) Snap grid shall be fixed to G.I Flat 40 x 3mm supporting hangers consisting of 4mm dia G.I rod n.exc 1.20m length with J bolts nuts and washer etc as per manufacture instructions & complete all as specified and as directed.
M&L for 4mm thick high pressure steam cured non asbestos fiber cement design board of size 600mm x 600mm fixing in ceiling complete all as specified and diredted.
Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stone work and precast concrete articlesl etc complete all as specified and as directed.
M&L brick work with fly ash bricks (FASB) conferming to IS 12894, of strength M-10 straight or curved on plan exc 6m mean radious built cement mortar 1:6 complete all as specified and as directed.
Cutting grooves in brick wall 100mm wide and 100mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc incl racking out joints hacking for key and scrabbing down with water etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces CM 1:4, and finishing the surface even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor or pavings n.exc 15cm thickness (below or above ground floor) complete all as specified and as directed.
M&L for 75mm thick cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in flooring, plinth protection /path finished even and smooth without using extra cement complete all as specified and directed.
Dismantling floor hearth wall tiling including cement mortar bedding but not backing removing serviceable meterial to store complete all as specified and as directed.
M&L for coloured ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.18 sqm but not exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor, over and including 15mm thick screed bed or bedding layer in cementy mortar 1:6 etc complete complete all as specified and as directed.
M&L for coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in colour cement to match to floor, over and incl 10mm thick rendering on wall or conc surfaces in cement mortar 1:4 ,complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 300 x 600 x 7mm thick for work on vertical surface such as skirting, dado, set & jointed in cement slurry and pointed in white or coloured cement to match the existing wall surfaces, over and incl 10mm thick rendering in cement mortar 1:4 etc complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 etc complete all as specified and as directed.
M&L for machine cut kota stone 18-20 mm thick in riser of step, skirting, dado and pillar laid over cement plaster laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over and including 10mm thick rendering or bedding layer in cement mortar 1:4, etc complete all as specified and as directed.
M & L for complete remoal of existing treatment from wall and appying two coat of oil bound distemper with roller over including prepration of surface complete all as specified and as directed.
M&L for complete removal of existing treament and applying two coat of cement base paint over with roller on external surface complete all as specified and as directed.
M&L for applying two coat of cement base paint with roller on new plaster surfaces of external surface complete all as specified and as directed.
M&L for a coat of JK/Birla wall care putty 1mm thick including preparation of surface complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each etc complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame)exc 1.5 sqm but not exe 1.5 Sqm each etc complete all as specified and as directed.
Taking down shutters of any description n.exc 1 sqm each removal to or from store complete all as specified and as directed.
Refixing shutters in same opening of any description n exc 1 sqm each from store including cutting and finishing complete all as specified and as directed.
S&F 125 mm x 60 mm size pressed steel frames for door with one or more rebates including necessary fixing lugs, hinge lock strike plate etc including one shop coat of red oxide primer including cutting holes and making good in PCC 1:2:4type B1 using 20 mm graded stone aggregate complete all as specified and as directed. Note :- 10mm deformed bar shall be provided in bottom & PCC will be provided in hollow frame in same rate.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete all as specified and as directed.
S&F 35mm thick factory made plain framed, panelled Shutters (two panel) of IInd class hard wood rail and styles with lock rail and panel of 12 mm BWP grade BWR Plywood. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified.
S & F 35 mm thick IInd class HW glazed & skeleton shutters open rebated and prepared to receive glass gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter as specified in SSR Pt I sec 8 Cl 8.20 (a), divided into squares with plain chamfered rounded, mitered and rebated sash bars etc complete all as specified and as directed.
S&F Stainlesss steel wire cloth, 0.36mm nominal dia of wire and avg width of aperture 1.40mm fixed with stainless steel wire staples etc complete all as specified and as directed.
M&L two coat synthetic enamel paint over one coat of pink primer on new wooden surface of any description not otherwise described over 10 cm width or girth etc complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section and fixed fixed 200 mm long etc complete all as specified and as directed.
S&F aluminum handles cast type anodized 150 mm size etc complete all as specified and as directed.
S&F mild steel, 300 mm ordinary door spring including roller and roller plate etc complete all as specified and as directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
S&F in repair steel windows z section with side hung shutters including box type hinges with steel handle and steel peg stay, with glazing bar dovetailed or welded for receiving glass after and including taking out old unserviseable steel window complete all as specified and as directed.
S&F in repair steel windows z section with side hung shutters including box type hinges with steel handle and steel peg stay, without glazing bar dovetailed or welded for receiving glass after and including taking out old unserviseable steel window complete all as specified and as directed.
M&L framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders ; framed balusters; walk ways; railings; framework of watertanks and similar work conforming to Fe 290. Gde-E-165 complete all as specified and as directed.
S&F Plain sheet glass 3mm thick ordinary quality and glazing with wooden beads or oil putty in square n. exc 0.5 sqm in each pane complete all as specified and as dirrected
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or or laboratory with plug washers and waste pipe including bedding in cement mortar to dwarf wall or incl fixing cantilever brackets and connecting union to pipe over all size 495mm x 420mm bowl size 410mm x 330 mm x 160mm. and to be fixed with granite or surface with proper gradient for wash out of water complete all as specified and as directed.
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone including cutting and polishing types over 15 mm thick in CM(1:6) etc complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in stair steps, cooking platform, and other similar situations etc complete all as specified and as directed.
S&F fancy type Stainless steel conduit curtain rod 32mm dia with fancy knob type ends and brackets complete all as specified and as directed by the Engineer-in-charge.
M & L surface excavation n . Exc 30cm deep and averaging 15cm deep and getting out soft and loose soil complete all as specified and as directed.
Excavation in post holes ( or similar holes) each n exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25m in soft/lose soil complete all as specified and as directed.
M&L PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete as sub base of floor complete all as specified and as directed.
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails; fixed with angle cleats or other connecting plates confirming to Fe 410-W (Gde- 250) complete all as specified and as directed.
M&L for Preparation of new steel surface of any description, over 10cm in width or girt and applying two coat of synthetic enamel paint over a coat of red oxide (ordinary tint) not otherwise described complete all as specified and as directed.
M&L for hardcore of broken stone or boulders gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for machine pressed precast concept interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and Coloured Pigment over 5mm thick sand bed over 100mm thick PCC type D2 1:4:8 (40mm graded aggregate) complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m in depth for foundation, manholes, pipe/cables etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
M & L for Brick work with sub class `B` bricks straight or covered on plan exc 6m mean radius built in cm 1:4 complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate) in copings, kerbs, channels, water through and the like including weathering, slightly rounded or chamfered angles and throating as directed chamfered necessary for work complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L returning filling in including spreading levelling, watering and well ramming in layers n.exc. 25mm in any type of soil complete all as specified and as directed.
Removing excavated material n.exc 50 mtr and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C2 (using 20mm graded crushed stone aggregate) as in plinth protection path laid in panel surface finished even and fair complete all as specified and as directed
S&F in jointing and testing 50mm bore of galvanised iron tube medium grade with all fittings such as bends, elbows sockets, etc and fixed and welding as required to laid in floor or trenches with new fittings for Cattle Trap complete all as specified and as directed.
S&F in jointing and testing galvanised iron tube 15mm dia bore, medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed.
S&F in jointing and testing galvanised iron tube medium grade 20mm dia bore with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed.
S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in repairs fancy type chromium plated cast copper alloy bib taps long shank & cup 15mm dia bore complete all as specified and as directed
Demolition of PCC/lime concrete (Other than Ground flooors) terracing including felt in any description and in any position over roof etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof and laid to required slope complete all as specified and as directed.
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for roughening surfaces of old concrete roof by picking ,sweeping, clean and washing down with water to remove dust etc and applying a coat of cement slurry @ 3 Kg per Sqm complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed.Note :- Water proofing compound shall be measured separately as supply only in item no 78
Supply only integral water proofing compound complete all as specified and as directed.
M&L for applying water proofing treatment with the following:-(a) First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated. (b) after the application of approved bituminous primer the water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyesterd non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction. (c) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane.
Taking up or down existing 15mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed
Taking up or down existing 20mm bore steel tubing and connections including cleaning for refixing or removal complete all as specified and as directed
Supplying, fixing, jointing and testing 15mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
Supplying, fixing, jointing and testing 20mm dia bore galvanised iron tubing medium grade with all fitting such as bends, elbow, socket, reducer etc and fixed to wall or laid in floor complete all as specified and as directed
Fixing only old 15mm dia bore steel tubing and connections obtained from taking down against item No 8(a) & (b) herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed
Fixing only old 20mm dia bore steel tubing and connections obtained from taking down against item No 80 & 81 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings complete all as specified and as directed
Cutting chases,pinning in,making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves,lintels etc,and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth in brick walls complete all as specified and as directed.
S&F 500 ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) WHITE , ISI marked , Triple layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600mm long with fitting incl dismantling existing completed all as specified in SSR Part-I 2009 completed all as specified and as directed.
Taking down and refixing 500 ltr capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) WHITE , ISI marked , Triple layered construction hoisted and fixed in position including S&F 20mm dia GI pipe medium grade washout pipe 450mm long with plug and 20mm dia GI pipe medium grade overflow pipe 600mm long with fitting etc complete all as specified in SSR Part -I 2009 complete all as specified and as directed.
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed
S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and complete all as specified and as directed.
M&L, screed bed or bedding layer of mortar 15 mm thick in cement mortar 1: 6 to receive tiles etc finished rough complete all as specified and directed.
M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc complete all as specified and directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1: 3 on fair faces of brick work or concrete surfaces, finished rough to receive tiles etc complete all as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick (square / rectangular) polished area of each tile exceeding 0.18 sqm but not exc 0.36 sqm, in Vertical surfaces such as skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc complete all as specified and as directed.
M&L for joint free glazed coloured tiles 350x250x7mm/450x350x7mm thick for work on vertical surface, set & jointed in cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick in CM(1:6) etc complete all as specified and directed.
Demolition of PCC in any description and in any position etc complete all as specified and as directed.
M&L for 50mm thick cement concrete 1:2:4 type B2 (using 40mm graded aggregate) as in floor/hardstanding finished even and smooth without using extra cement complete all as specified and directed.
M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 60 mm thickness M-40 Grade , machine pressed precast concrete Inter locking paver blocks any shape & size with grey cement and pigment conf to IS-15658-2006 laid dry over sand cushion complete all as specified and directed.(Sand cushion shall be measured and paid separately)
M&L, Brick work with sub class ;B; bricks old size half brick thickstraight or covered on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for rendering 10mm thick in CM 1:6, on fair faces of conc/brick wall surfaces finish even and smooth without using extra cement complete all as specified and as directed
M&L for renderig 5mm thick in cement mortar 1:3 on ceiling surface and finished even and smooth with out using extra cment complete all as specified and as directed.
M & L for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed.
M & L for Preparation of new plastered surface of wall and applying two coat of OBD over a coat of putty compleet all as specified and as directed.
M & L for preparation of new plastered surface of wall and applying two coats of cement base paint on external wall surface over a coat of alkali resistant primer complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exe 1.5 Sqm but n exc4 Sqm each etc complete all as specified and as directed
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail,paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as directed and specified by Engineer-in-Charge.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube etc complete complete all as specified and as directed.
S&F aluminum anodized barrel tower bolts of extruded section & fixed 150 mm long etc complete all as specified and as directed
S & F butt hinges medium weight cold rolled, mild steel and fixed 100 mm size etc complete all as specified and as directed.
S&F but hinges extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed, type C-21 100 mm size in toilet for PVC doors etc complete all as specified and as directed.
S&F Pressed steel frames for doors(125x60) mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed etc complete all as specified and as directed.
S&F Pressed steel frames for doors(105x60) mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed etc complete all as specified and as directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and directed.
M & L secound class hardwood Plain, solid, straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed.
S&F 18mm thick Rajshri Celuka ply of grade 1 quality of both side plain white colour fixed with screws, solvent cement/adhesive to to timber frame work etc complete all as per specifications and as directed by the Engr-in-Charge
S&F Hasp & staple safety type aluminium anodized with mild steel hing pin incl bolt to hing plate and fixed with screws 100mm size etc complete all as specified and as directed.
S & F 40 mm dia, cup board knobs fixed with nut, screw and washer of brass, polished complete all as specified and as directed
S&F, 35 mm thick Flush shutters, factory made, solid core construction, with block board core and plywood face panels, with decorative face veneers on both faces with lipping to match complete all as specified and directed.
S&F factory made fabricated 35 mm thick IInd class HW glazed & skeleton shutters open rebated and prepared to receive glass gauge etc. (without sash bars) edges of framing plain chamfered or rounded fitted with cut & mitered beads for security glass/gauge etc. size of members of shutter as specified in SSR Pt I sec 8 Cl 8.20 (a), divided into squares with plain chamfered rounded, mitered and rebated sash bars etc complete all as specified and as directed
S&F galvanized mild steel wire cloth 0.63 mm nominal dia of wire and avg width of a-pertare 1.40 mm fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed
M&L for preparation new wooden surface of any description not otherwise described over 10 cm width or girth and applying two coat synthetic enamel paint over one coat of pink primer etc complete all as specified and as directed
S&F in repairs Vitreous chine wash down water closet pan(padestal pattern), white(EWC) including plastic seat of same colour of Wc, closed pattern with flat bottom, and cover mild steel chromium plated hinging device complete all as specified and as directed.
S & F in repair 10 ltrs capacity PVC low level flushing cistern sleek plus single flush of colour star white with inlet, float valve and handle with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed.
S&F wash hand basin counter top,size 480x400x150mm brand cera, cat no S 2020145 or equivalent, including CP coupling and waste pipe, including ,cutting of granite shelf complete all as specified and directed.
S&F glass self (500mmX60mm) with ABS brackets (450X125X6) and fixed to wall with CP brass screws complete all as specified and as directed.
Supply and fixing CP corner glass shelf with bracket fixed with screws complete all as specified and as directed by Engineer-in-Charge.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed.
S&F brass CP mixer 15mm dia bore mixing hot & cold water for wall screwed down for iron pipe and fixed complete all as specified and as directed.
S&F in repair 15mm bore cast copper alloy chromium plated angle cock with flange complete all as specified and as directed.
S&F in repair 15mm bore fancy type chromium plated bib cock long body with flange etc complete all as specified and as directed.
S&F brass CP mixer 15mm dia bore mixing hot & cold water for wash hand basin screwed down for iron pipe and fixed complete all as specified and as directed.
S/F brass chromium plated health faucet for EWC screwed down to GI tubing/fittings 15mm dia incl 1200mm long stainless steel connection complete all as specified and directed.
S&F in repair PVC floor trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed.
S & F tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed
S&F in repair 125 mm Brass chromium plated shower rose with or without swivel joints, any size, including fixing of steel pipe or union and fixed complete all as specified and directed.
S&F in repair 25 mm dia chromium plated curtain rod with CP brackets and knobs at both end as per sample approved by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC/PVC/CI or Reinforced concrete) set in cement mortar in floors or wall in 100mm dia meter complete all as specified and directed.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with clamp out of 25x3mm flate Iron including bolts and nuts 110mm bore complete all as specified and directed.
S &F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall and complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal 110mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
M&L for 100mm internal dia Salt-glazed stoneware drain pipes including fittings laid in trenches and jointed complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate as in concrete bed to drain pipes including packing under, and hunching against the side of pipe after they are laid and tested, in 100mm dia pipe complete all as specified and directed.
M & L for complete removal of existing treatment from surface of wall all as specified and as directed by the Engineer-in-Charge
M & L for applying one coat of putty at the rate of 1.2Kg per 10Sqm of wall surfaces complete all as specified and as directed by the Engineer-in-Charge
M & L for applying two coat of oil bound distemper on prepared surfaces of wall aomplete all as specified and as directed by the Engineer-in-Charge
M&L Preparing old decorated surfaces of wall and applying two coats cement base paint all as specified and as directed.
M&L, Preparing old plastered/unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M & L for application of one coat of water based bitumen emulision primer @ 0.3 lit per sqm including cleaning of surface thoroughly from dust & dirt. Lay water proofing treatment with polymetric memberane 3 Kg/ sqm standard consisting of 90 micron, HMHDPE torch on memberane over a coat of blown bitumen 85/25 @ 1.2 Kg/sqm on top of memberane and providing 25 mm thick sand cushioning to recieve lean concrete in sunken floor complete, all as directed and as specified.
M&L for PCC (1:5:10) type E2 using 40 mm graded stone aggregate as in filling and mass concrete complete all as directed and as specified.
M&L for PCC 1:2:4 type B0 (using12.5 mm stone aggregate) of avg 25 mm thick make to slope in sunken floors complete all as specified and directed.
M&L rendering 15mm thick in CM 1:3 on fair faces of brick/concrete surfaces of sunken floors incl WPC finished even and fair with out using extra cement complete all as specified and directed. Note:-WPC will be measured paid separately.
Taking down carefully unserviceable aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, lamp holders, sockets, fan regulators, wooden terminal box plastic laminated sheet cover from TW battens including TW batten or drawing from existing conduit removing including TW batten all as specified and as directed by Engr-in-Charge.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size any capacity from boards complete all as specified and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
M & L for concealed point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed .
Description same as per item No 165 above but one fan point controlled by one switch.
Description same as per item No 165 above but one fan point controlled by one switch & regulator.
Description same as per item No 165 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description same as per item No 165 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 165 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S&F ceiling rose,surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F Sheet metal enclosure double door concealed suitable for distribution board when MCB to be used having 100 Amp rated bus bar 8 way SPN DB 240 volts complete all as specified and as directed.
S&F MCB single pole and neutral 63 Amp 240 V ,10KA , 'C' series, connected with copper lugs complete all as specified and as directed.
S&F Rigid non-metallic PVC conduit not less than 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV type 1 flat size 250x150x40mm peak, size 300mm x 180mm x 40mmlaid perpendicular to the axis of cable in trenches complete all as specified and as directed.
S&F in replacement of 36W of size 2 feetx2feet LED 6500K recessed mounting luminaire glare free suitable for armstrong/grid ceiling in MS/CRCA housing with high brightness LEDs including and terminating into existing ceiling rose complete all as specified and as directed.
S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Minimum air delivery 210CFM with service value 6.00BEE. Five star rated with squirrel cage induction motor, copper binding complete all as specified and as directed.
S&F exhaust fan, copper binding, steel body AC, Single Phase, 230V of size 300mm sweep, 1400RPM with louvre complete including all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessry fixing arrangement such as fastrener, bolts, nuts, washers etc of appropriate size complete all as specified and as directed.
Supply and lay river bed sand free from sharp materialsa for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed .
Supply and laying GI pipe 50mm bore "LIGHT GRADE" in trenches, under floors, roads, along poles for protection of cables, including sealing ends complete all as specified and as directed.
Supply and fix post top lantern polycarbonate body 20-25 watt lamp and B-22 lamp holder and GI pipe 40mm dia, 2mtrs long complete ass as specified and as directed.
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series, connected with copper lugs complete all as specified and as directed.
S&F MCCB 4 pole, 415V, AC , 3 phase, 50 HZ, breaking capacity 16 KA with fixed thermal and fixed magnetic setting of capacity 100 Amps 'C' series complete all as specified and as directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified as directed.
S&F LED security/street light fittings1x35W LED 5700K energy saving and envoiremental frendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LED as light siurce and electronic driver suitable for pole dia 35mm including 35mm dia light grade tube bracket, bend to shape 1.80m long with two numbers clamp of size 50mmx6mm with nuts, bolts, washers etc including connection with 1.5Sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on wall /pole complete as ditrected by Engineer in Charge. Make: Bajaj Cat Part No BRLEP20WLEDWH or equivalent make as specified in Appendix B to particular specification.
S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent make as specified in Appndx 'B' to PS .
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit and conduit accossories shall be measured separately.
Supply and fixing in repair 22W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 22watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 25 sqmm 4 core as per IS 7092 Pt-I complete all as specified and as directed.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 16 sqmm 4 core as per IS 7092 Pt-I complete all as specified and as directed.
S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as outgoing Nos of modules DPX 125+12, including 125 Amp MCCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/S JAI BALAJI TRADERS
M/S Ritu Tandon
ARTISTIC BUILD CO
ROHIT ENTERPRISES
SHRI HARI CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .