| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹31.7 L+₹2.9 L (10.1%)Rejected-AOC | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹33.9 L+₹5.1 L (17.7%)Rejected-AOC | L3 | Rejected-AOC Other than lowest | |
| 4 | L4₹38.9 L+₹10.0 L (34.8%)Rejected-AOC | L4 | Rejected-AOC Other than lowest | |
| 5 | L5₹39.3 L+₹10.4 L (36.2%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-AOC Other than lowest |
Tender Value
₹49.0 L
EMD Value
₹97,980
Closing Date
1 Jun 2021, 6:00 pmClosed
GE (N) Mamun
GE (N) Mamun C/O 56 APO
OUTSOURCING OF E/M SERVICES FOR ELECTRIC SUPPLY INSTALLATIONS UNDER AGE E/M-I OF GE (N) MAMUN
2021_MES_439995_2
GE(N)/M- /2021-22 NIT-03
Open Tender
Civil Works
Item Rate
334 days
GE (N) Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) Mamun
₹97,980
Yes
11 Jun 2021
17 May 2021
4 Jun 2021
17 May 2021
1 Jun 2021
18 May 2021
Amount
Outsourcing of services for 11 KV main electric receiving/distribution Sub Stn at (D-IB Zone) round 'O' clock 3x8Hrs per shift (24 hrs) and routine maintenance of all area of DIB Zone by taking proper precautions, Comprises of following:- (a) HT VCB 630A- 08Nos. Make: Kirloskar/Areva/ABB/CG, (b) GOD 11KV 200/400A- 12Nos, (c) LT Panels and transformers, (d) HT capacitor bank 16978 KVA- 01No Above services for D-IB Zone Sub Station Area to be provided by deployment of following:-
Electrician- 01No/Shift
Helper to Electrician-01No/Shift
Outsourcing of services for 11 KV main electric receiving/distribution Sub Stn at (D-II MAP Zone) round 'O' clock 3x8Hrs per shift (24 hrs) and routine maintenance of all area of DIB Zone by taking proper precautions, Comprises of following:- (a) HT VCB 630A-06Nos. Make: Kirloskar, (b) GOD 11KV 200/400A-21Nos, (c) LT Panels and transformers, Above services for D-II MAP Zone Sub Station Area to be provided by deployment of following:-
Electrician- 01No/Shift
Helper to Electrician-01No/Shift
Outsourcing of services for 11 KV main electric receiving/distribution Sub Stn at (D-III Zone) round 'O' clock 3x8Hrs per shift (24 hrs) and routine maintenance of all area of DIB Zone by taking proper precautions, Comprises of following:- (a) HT VCB 630A- 03Nos. Make: Alstom, (b) HT VCB 630A- 05Nos. Make: ABB, (c) GOD 11KV 200/400A- 07 Nos, (d) HT capacitor bank - 01No, (e) LT Panels and transformers, Above services for D-III Zone Sub Station Area to be provided by deployment of following:-
Electrician- 01No/Shift
Helper to Electrician-01No/Shift
Outsourcing of services for 11 KV main electric receiving/distribution Sub Stn at (D-IV Zone) round 'O' clock 3x8Hrs per shift (24 hrs) and routine maintenance of all area of DIB Zone by taking proper precautions, Comprises of following:- (a) HT VCB 630A- 07Nos. Make: Alstom/Crompton, (b) GOD 11KV 200/400A - 06Nos, (c) LT panel with ACB as incomer and MCCBs as outgoing - 01No, (d) Transformer Above services for D-IV Zone Sub Station Area to be provided by deployment of following:-
Electrician- 01No/Shift
Helper to Electrician-01No/Shift
Notes for Srl item No 01 to 04 above required for each Sub Stn :- 1. Operating staff required per day for 3 Shifts are as under :- (a) Electrician - 03 Nos (b) Helper for Electrician - 03 Nos 2. Nature of work involved :- (a) Periodical inspection and maintenance of records thereof. (b) Periodical checking of earthing of HT Panels, GODs and maintaining records thereof (c) Operations of GODs and replacement of GOD fuses if required. (d) Operations of HT VCB's, GODs, battery bank and relays etc. (e) Maintaining of daily log sheet and record of Sub Stn (f) 3 Shift timing for shift duty (including reliever as required) 0600 hrs to 1400 hrs (Ist Shift) 1400 hrs to 2200 hrs (2nd Shift) 2200 hrs to 0600 hrs (3rd Shift) Shift timings may be changed according to the requirement or as directed by Engineer in Charge 3. Qualification of Electrician :- Diploma holder in Electrical Engineering or ITI in electrician trade with 2 years experience in operating/ maintaining of HT Panel/machineries. 4. Contractor's staff should politely attend telephone if any and register electric complaint in complaint register and submit the same daily at 0830 hrs to JE in charge for distribution of complaints
5. Contractor shall also be responsible for the following :- (a) To carryout cleaning of Sub Stn building inside/outside area by cutting/removing seasonal grass, bushes etc and keep installation daily in presentable condition. (b) Maintain daily log sheet hour wise duly completed in all respect and shall be deposited in AGE E/M-I office at the end of every month. (c) Contractor shall provide all the assistance, Safety Equipments and tools required for proper maintenance of Sub Stn which is deemed to be included in quoted rate, attending the rectification of break down of OH lines in HT/LT feeder complete area including replacement of blown out HT/LT fuses. (d) Attending and rectification of break down of HT receiving lines/distribution HT/LT feeder in respective area including replacement of blown out HT/LT fuses. The material required for maintenance will be provided by Deptt as per nature of complaint. (e) Contractor shall submit the educational qualification document, experience certificate, residential and police verification before employing the staff. (f) Any damage to the the Installation or Part of Installation due to negligence or Wrong Workmanship will be rectified by Contractor without any Extra Cost.
TRIVENI CONSTRUCTIONS
Standard engineers
M/S J N TRADERS
M/S DUGGAL CONSTRUCTION CO
M/S BALWINDER SINGH
GANDOTRA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .