Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹8.7 L+₹30,895 (3.68%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹11.4 L+₹3.0 L (36.0%)Rejected-Finance | L3 | Rejected-Finance L1 being accepted |
Tender Value
₹12.9 L
EMD Value
₹25,760
Closing Date
27 Feb 2024, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2024_MES_640368_1
8522/E8 GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (P) Navy Mandovi
₹25,760
Yes
13 Mar 2024
2 Feb 2024
29 Feb 2024
2 Feb 2024
27 Feb 2024
9 Feb 2024
2 Feb 2024 - 8 Feb 2024
Amount
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including PVC casing caping of 25/ 32 mm size fixed on wall/ ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC casing caping shall be measured as unit length.
M & L for submain wiring with two runs of 6 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 6 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including PVC casing caping of 25/ 32 mm size fixed on wall/ ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run of PVC casing caping shall be measured as unit length.
Supply and install hi wall split type air conditioner unit, indoor/outdoor complete with cordless remote control unit and with in built air-ioniser, copper condensor and plasma filter for better indoor air quality with BEE 5 star rating, rated power range 220-240 volts and 1.5 ton capacity, including all accessories complete all as specified and directed. Notes: a) Quoted rate shall be deemed to be inclusive of cost of making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type as necessary), T & P for installation & making good the disturbed surface. b) Quoted rate shall be deemed to be inclusive of cost of copper tube for suction & discharge upto 3 RM length. Excess quantity used at site shall be measured and paid seperately under relevant item of this schedule.
Supply and install hi wall split type air conditioner units, indoor/outdoor complete with cordless remote control unit and with in-built air-ioniser, copper condensor and plasma filter for better indoor air quality with BEE 5 star rating and EER 3.2 rating, rated power range 220-240 volts and 2 ton capacity, including all accessories complete all as specified and directed. Notes: a) Quoted rate shall be deemed to be inclusive of cost of making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type as necessary), T & P for installation & making good the disturbed surface. b) Quoted rate shall be deemed to be inclusive of cost of copper tube for suction & discharge upto 3 RM length. Excess quantity used at site shall be measured and paid seperately under relevant item of this schedule.
S & F wall mounting type voltage stabilizer with digital display showing voltage input & output for automatic operation, single phase, naturally air cooled indoor type, designed for input variation between 170 V to 250 V, with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed.
S & F superlon rubber foam insulation for copper tubes along with white wrapping tape of size suitable for split AC units specfied in item no 2 and 3 here-in-before complete all as specified and directed. Note: Two runs of rubber foam insulation for suction and discharge line alongwith white wrapping tape shall be measured as unit length.
S & F copper tubing, soft grade, suitable for split AC suction/ discharge line of size suitable for split AC units specfied in item no 2 and 3 here-in-before complete all as specified and directed. Note: Two runs of copper tubing for suction and discharge shall be measured as unit length.
S & F sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240 Volts, 'C' series, complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, SPN 4 way with 200 Amps rated bus bar, 240 Volts, complete all as specified and directed.
S & F sheet metal enclosure for MCB's (D.B), double door, SPN 8 way with 200 Amps rated bus bar, 240 Volts, complete all as specified and directed.
S & F MCB SPN 06 to 32 Amp, 'C' series, suitable for 240V 50Hz AC supply complete all as specified and directed.
M & L for removing complete indoor and oudoor unit of split AC upto 2 ton capacity from one location and refixing at another location including all connected electric, refrigerant pipe line and other installation works complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cost of making hole in wall, insulation of copper tubes, stand for outdoor unit (wall mounted/roof top type as necessary), T & P for installation & making good the disturbed surface.
S & F heavy duty PVC flexible pipe of 15mm dia bore with necessary jubilee clips for water cooler/ split ACs/ window ACs drains complete all as specified and directed.
cooltech engineering services
INDIAN AIR CONDITIONING SERVICES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .