Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.5 LAccepted-AOC | 1 | Accepted-AOC The lowest bidder. | |
| 2 | 2₹25.5 L+₹43,102.60 (1.72%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | 2 | Rejected-Finance Not the lowest bidder. | |
| 3 | 3₹25.7 L+₹65,571 (2.62%)Rejected-Finance | 3 | Rejected-Finance Not the lowest bidder. | |
| 4 | 4₹26.1 L+₹1.1 L (4.35%)Rejected-Finance | 4 | Rejected-Finance Not the lowest bidder. | |
| 5 | 5₹26.2 L+₹1.1 L (4.49%)Rejected-Finance | 5 | Rejected-Finance Not the lowest bidder. |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
28 Nov 2019, 6:00 pmClosed
Commander Works Engineer Dinjan
Headquarters Commander Works Engineer Dinjan Military Engineer Services Post - Panitola, Dist - Dibrugarh Pin Code - 786 183 (Assam)
SPECIAL REPAIR TO BLDG NO P-14 AND P-16 JCO/OR MD ACCN OF 764 ASC BN (AM) AT NEPALIPATTI UNDER GE DINJAN
2019_MES_293106_1
82957/E8
Open Tender
Civil Works
Item Rate
180 days
Dinjan
As per tender documents
7 documents required · 7 mandatory
₹500
GE Dinjan
₹47,000
Yes
20 Jan 2020
26 Oct 2019
29 Nov 2019
26 Oct 2019
28 Nov 2019
16 Nov 2019
26 Oct 2019 - 28 Nov 2019
Amount
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified.
Taking down wooden chowkhats or frames area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
Dismantling of Asbestos cement(corrugated, semi corrugated etc.) sheet in roof coverings.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and keeping aside for credit complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level)
M & L for RCC M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
Dismantling timber scantlings in unframed works, 40 sqcm and over in section, in any position
M & L for structural timbers of group B, first or second choice as per IS 3629: 1986, wrought in scantlings and timber framed and fixed complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
M & L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with one coat of creosote complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M & L 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates finished surface even and fair as in plinth protection all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 125 mm X 60 mm, Profile D, double rebate including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (multi panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated.
S & F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with wood free EPS core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 125 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 100 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F cast aluminium alloy handle, cast type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for non skid, rectified, colour ceramic floor tiles (group B II), area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
M & L for glazed, colour ceramic wall tiles (group B III), area of each tile exceeding 0.04 sqm but not exceeding 0.12 sqm, length less than 340 mm, minimum 7 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match all as specified and directed.
Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clean and washing down complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and as directed. Note:- Water proofing compound shall be measured and paid for separately.
Material & labour for rendering 20 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction finished even and fair complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only)
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 20 mm thick machine cut granite tiles (any type) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with granite stone shade including 20 mm thick screed in cement mortar 1:4 including grinding and polishing complete all as specified and as directed.
M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed
M & L for complete removal of existing finish on walls including chajjas, facias etc and applying two coat of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Complete removal of existing treatment of wall and M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick wall care putty to match the surfaces complete all as specified and as directed
Preparation of newly plastered surfaces/boards on ceilings and applying three coats of white wash complete all as specified and as directed.
Supply only liquid water proofing compound.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
M & L for frame work consisting sections made of mild steel sheet galvanised with zinc coating of grade 120 gram per sqm as per IS 277:2003 and the sections of perimeter channel of size 20 mm (flange) X 27 mm (web) X 30 mm (flange) X 0.50 mm (thickness), intermediate channel of size 15 mm (flange) X 45 mm (web) X 15 mm (flange) X 0.80 mm (thickness), ceiling section 80 mm (total width) X 26 mm (flange) X 51 mm (web) X 0.50 mm (thickness), angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, angle hangers of size 25 mm X 10 mm X 0.50 mm and of required length, mild steel galvanised with zinc coating dash fastener of size 12.5 mm dia x 50 mm long and connecting clip made out of 2.64 mm dia x 230 mm long galvanised mild steel wire, fixing perimeter channel on the wall along the perimeter of ceiling using nylon sleeves wall plug at 450 mm centre to centre spacing, hanging intermediate channel at 900 mm centres to centre spacing with soffit of ceiling using rawl plug, dash fastener, angle cleat, angle hangers at 900 mm centre to centre spacing, fixing ceiling section to the intermediate channel transversely at 450 mm centres to centre spacing using connecting clip at every junction complete all as specified and as directed.
S & F 8 mm thick calcium silicate board made with calcareous & siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sqcm, bending strength 100 kg/sqcm, tapered edge, fixing to ceiling section and perimeter channel using dry wall screws of size 3.5 mm X 25 mm at 230 mm c/c including jointing and finishing to a flush finish of tapered edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm, complete all as specified and directed by Engineer in charge.
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store or taken on schedule of credit (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and directed by Engineer- in- charge.
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge.
S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed.
S & F 15 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S & F grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
S & F in repairs shower arm 15 mm size, 195 mm long with bend of 45⁰ with flange of PTMT any colour, minimum weight 40 gms complete all as specified and as directed.
M & L for liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 105 gms) complete all as specified and as directed.
S & F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastics cleats, minimum weight 190 gms complete all as specified and as directed.
S & F cast iron, centrifugally cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 3389: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed.
S & cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without access door for soil, waste and vent pipes of nominal size 100 complete all as specified and as directed.
S & F cast iron Traps 'P' or 'S' for 100 mm bore pipe complete all as specified and as directed.
S & F mild steel sliding door bolts, type I (plate type), size 250 mm, stove enamelled black finish to back plate, straps and staple, electroplated finish with nickel and chromium to hasp and bolt, bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
M & L for concrete cradle in M15 (Nominal Mix) concrete using 40 mm nominal size graded crushed stone aggregate for laying of concrete pipes complete all as specified and as directed.
Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP3, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed.
Cutting into existing manholes for connecting new drains of pipe of nominal size 200 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F in repairs bib tap standard of PTMT, any colour, high pressure, minimum weight 90 grams, screwed for steel tube for nominal size 15 mm complete all as specified and as directed.
S & F in repairs sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F flexible (coil shaped) PVC waste pipe for sink and wash basin 40 mm dia with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed.
S & F in repairs aluminium wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and as directed.
Cutting chases in brick walls to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., exceeding 20 cm girth and making good the same with cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate or cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 complete all as specified and as directed.
S & F in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
M & L for plain cement concrete tiles, general purpose, double layer of size 25 cm X 25 cm X 16 mm thick with grey cement and pigments in wearing layer as per IS 1237: 2012, set, jointed and pointed in neat cement slurry in floor including laying over 15 mm thick bedding of cement mortar(1:4) all as specified and as directed.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down old unserviceable submain wiring 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface to match the existing surface complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
Supply and fix sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note - Two runs of 6 sqmm cable, one run of 4 sqmm cable and one run of casing/capping shall be measured and paid as one unit length.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F switch socket combination with (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 6 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A and indicator and fuse complete all as specified and as directed.
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F batten including tube light 20W, made of CRCA steel sheet, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 140 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2000, lumen efficacy of minimum 100 lumens per watt, low loss constant current driver (>85% efficiencies with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, THD less than 10%, CW available CCT of 4000K, power factor of minimum 0.95, life span of minimum 50000 working hours as per Product Code 112177, catalogue reference BLTRU 20W NW VIVA of Bajaj or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
S & F LED street lights/ building security light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, lumen output of minimum 4500, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 65, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per product code No. HPLLEDSL2060S of HPL or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed.
Taking down main switch/MCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 50 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F PVC rectangular block for mounting DBs, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350 mm X 300 mm and 50 mm deep complete all as specified and as directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Fixing/ hanging only in repairs ceiling fan and connecting up including provision of cable from ceiling rose of connectors to fan complete all as specified and as directed.
R D Enterprises
M/s GANDHESWAR PHUKAN
M/S HAZARIKA CONSTRUCTION
M/S. NOBIN RAJKHOWA
R.D.CONSTRUCTION
M/S Karen Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .