Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹8.0 L+₹56,741.15 (7.68%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹10.0 L+₹2.6 L (35.3%)Rejected-Finance VILL POST GOASI DIST PURNEA BIHAR 854301 | PURNEA | PURNEA | BIHAR | 854301 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹10.0 L+₹2.6 L (35.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹10.2 L+₹2.8 L (38.3%)Rejected-Finance 00 HAIDARPUR JAMALPUR ROAD SADAR JAUNPUR UTTAR PRADESH 222001 | JAUNPUR | UTTAR PRADESH | 222001 | L5 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | Soma Enterprises L1 | shashi bhushan gupta L3 | M/S SATISH KUMAR SINGH & SONS L7 | M/S. KESHAB CHANDRA GHOSH L6 | M/S. R.K. ENTERPRISES L5 | ALAM ENTERPRISES L4 | M/s. Mohan Enterprise L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for Circuit /Submain wiring with two runs of 4.0 Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100 Volt alongwith one run of 4.0 Sqmm as earth wire, drawn through and including PVC casing caping with conduit accessories, complete all as specified and as directed. Note - 1. Two runs of 4.0 sqmm cable, one run of PVC casing/ caping and one run of 4.0 sqmm copper earth wire shall be
measured as one unit length. 2. Supplying and fixing of joint and junction boxes, Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through joists and making good all disturbed work to match the existing is included in quoted rate, nothing extra will be paid. 3. Supplying and fixing of bushed conduit or porcelain tubing for wiring to pass through walls, floors, etc. is included in quoted rate, nothing extra will be paid. | 1,800 | Running Metre | 287 ₹5,16,600 | 340 ₹6,12,000 | 360 ₹6,48,000 | 350 ₹6,30,000 | 350 ₹6,30,000 | 340 ₹6,12,000 | 262 ₹4,71,600 Lowest |
| 2.00 | Material and labour for Circuit /Submain wiring with two runs of 6.0 Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100 Volt alongwith one run of 6.0 Sqmm as earth wire, drawn through and including PVC casing caping with conduit accessories, complete all as specified and as directed. Note - 1. Two runs of 6.0 sqmm cable, one run of PVC casing/ caping and one run of 6.0 sqmm copper earth wire shall be
measured as one unit length. 2. Supplying and fixing of joint and junction boxes, Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through joists and making good all disturbed work to match the existing is included in quoted rate, nothing extra will be paid. 3. Supplying and fixing of bushed conduit or porcelain tubing for wiring to pass through walls, floors, etc. is included in quoted rate, nothing extra will be paid. | 199 | Running Metre | 301 ₹59,899 | 450 ₹89,550 | 460 ₹91,540 | 500 ₹99,500 | 455 ₹90,545 | 450 ₹89,550 | 270 ₹53,730 Lowest |
| 3.00 | Supply and fixing switch socket with 16A-25A MCB protected Power unit with PVC complete with connection testing and commissioning, complete all as specified and directed. Make: C&S ElectricLtd, Cat part No-CG26404PWNR or equivalent model of make L&T/ Legrand/ABB/Siemens as approved by AGE(I). | 190 | Each | 611 ₹1,16,090 Lowest | 1,140 ₹2,16,600 | 1,190 ₹2,26,100 | 1,195 ₹2,27,050 | 1,150 ₹2,18,500 | 1,140 ₹2,16,600 | 1,100 ₹2,09,000 |
| 4.00 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. | 190 | Each | 202 ₹38,380 Lowest | 390 ₹74,100 | 420 ₹79,800 | 440 ₹83,600 | 398 ₹75,620 | 390 ₹74,100 | 290 ₹55,100 |
| 5.00 | Supply and fixing in replacement of existing sheet metal enclosure for DBs single door 2(two) way when MCBs to be used single pole and neutral 240 V complete with connection testing and commissioning, complete all as specified and directed. | 11 | Each | 706.35 ₹7,769.85 | 650 ₹7,150 | 700 ₹7,700 | 750 ₹8,250 | 660 ₹7,260 | 656 ₹7,216 | 550 ₹6,050 Lowest |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
24 Jun 2026, 6:00 pmClosed
Shri Shrikant H Lakapate, AE(Civil)
AGE (I) AF PURNEA, P.O - CHUNAPUR AIR FIELD, DIST- PURNEA BIHAR, PIN CODE- 854303
PROVN OF DEFICIENT POWER SOCKETS AT CERTAIN SMQS FOR INSTALLATION OF AC AT AF STATION PURNEA UNDER AGE(I) (AF) PURNEA
2026_MES_769781_1
8171/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Purnea
As per tender documents
7 documents required · 7 mandatory
₹500
AGE (I) AF PURNEA
₹18,000
Yes
19 Aug 2026
4 Jun 2026
26 Jun 2026
4 Jun 2026
24 Jun 2026
18 Jun 2026
4 Jun 2026 - 18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for Circuit /Submain wiring with two runs of 4.0 Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100 Volt alongwith one run of 4.0 Sqmm as earth wire, drawn through and including PVC casing caping with conduit accessories, complete all as specified and as directed. Note - 1. Two runs of 4.0 sqmm cable, one run of PVC casing/ caping and one run of 4.0 sqmm copper earth wire shall be
measured as one unit length. 2. Supplying and fixing of joint and junction boxes, Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through joists and making good all disturbed work to match the existing is included in quoted rate, nothing extra will be paid. 3. Supplying and fixing of bushed conduit or porcelain tubing for wiring to pass through walls, floors, etc. is included in quoted rate, nothing extra will be paid. | 1,800 | Running Metre | - | - |
| 2 | Material and labour for Circuit /Submain wiring with two runs of 6.0 Sqmm PVC FRLSH insulated copper conductor cable, single core multi stranded 1100 Volt alongwith one run of 6.0 Sqmm as earth wire, drawn through and including PVC casing caping with conduit accessories, complete all as specified and as directed. Note - 1. Two runs of 6.0 sqmm cable, one run of PVC casing/ caping and one run of 6.0 sqmm copper earth wire shall be
measured as one unit length. 2. Supplying and fixing of joint and junction boxes, Cutting holes in or through walls, taking up and refixing floor boards, notching or drilling holes through joists and making good all disturbed work to match the existing is included in quoted rate, nothing extra will be paid. 3. Supplying and fixing of bushed conduit or porcelain tubing for wiring to pass through walls, floors, etc. is included in quoted rate, nothing extra will be paid. | 199 | Running Metre | - | - |
| 3 | Supply and fixing switch socket with 16A-25A MCB protected Power unit with PVC complete with connection testing and commissioning, complete all as specified and directed. Make: C&S ElectricLtd, Cat part No-CG26404PWNR or equivalent model of make L&T/ Legrand/ABB/Siemens as approved by AGE(I). | 190 | Each | - | - |
| 4 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. | 190 | Each | - | - |
| 5 | Supply and fixing in replacement of existing sheet metal enclosure for DBs single door 2(two) way when MCBs to be used single pole and neutral 240 V complete with connection testing and commissioning, complete all as specified and directed. | 11 | Each | - | - |
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
TENDER8171.pdf
Tender Documents • 0.81 MB
BOQ_862036.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .