Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC | ₹11.0 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹13.9 L+₹2.8 L (25.7%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | ₹13.9 L+₹2.8 L (25.7%) | L2 | Rejected-Finance rejected financially |
| 3 | L3₹13.8 L+₹2.7 L (24.9%)Rejected-Finance | ₹13.8 L+₹2.7 L (24.9%) | L3 | Rejected-Finance Rejected financially |
| 4 | L4₹17.3 L+₹6.3 L (57.1%)Rejected-Finance | ₹17.3 L+₹6.3 L (57.1%) | L4 | Rejected-Finance Rejected financially |
| 5 | Rejected-Technical A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | - | - | Rejected-Technical Technicaly rejected |
| Sl No | Description | Qty | Unit | Lyric International L3 | AERIZO TECHNOLOGIES L4 | TRANSTECH L2 | REFRIGERATION AND AIRCONDITIONING CORPORATION L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | SITC of Air-cooled ceiling suspended 8.5 TR ductable split units in compliance with latest QCO guidelines complete with highly energy efficient single Scroll Compressors, Copper condenser coil, Copper evaporator coil, unit mounted microprocessor based control panel complete with all accessories suitable to operate on ecofriendly refrigerant R-410A (As per direction of E.I.C)
(1 Working + 1 Stand By)
(MAKE: VOLTAS/BLUE STAR/MITSUBISHI HEAVY/O-GENERAL) | 2 | Sets | 2,29,066 ₹4,58,132 | 2,00,218.9 ₹4,00,437.8 Lowest | 3,09,595 ₹6,19,190 | 2,20,000 ₹4,40,000 |
| 2.00SITC of Soft/Hard drawn Copper Refrigerant piping complete with thermal insulation by closed cell Nitrile Rubber Insulation, Nitrogen pressure testing, leak testing, vacuumizing, Refrigerant charging and commissioning work by using proper scaffolding and safety arrangements. (As per direction of E.I.C) MAKE: RAJCO / ROYKU / UNIFLOW / NIPPON / MANDEV | |||||||
| 2.01 | 1-1/8" dia and 1 mm thick hard drawn Copper Suction Tube with 19mm thick Nitrile Rubber insulation In between Indoor & Outdoor Units. | 45 | RM | 950 ₹42,750 Lowest | 1,706.28 ₹76,782.6 | 1,214 ₹54,630 | 1,270 ₹57,150 |
| 2.02 | 5/8" dia and 1 mm thick hard drawn Copper Liquid Tube In between Indoor & Outdoor Units | 45 | RM | 495 ₹22,275 Lowest | 749.3 ₹33,718.5 | 594 ₹26,730 | 655 ₹29,475 |
| 2.03 | Refrigerant R-410 | 16 | KGS | 750 ₹12,000 | 1,388.86 ₹22,221.76 | 950 ₹15,200 | 1 ₹16 Lowest |
| 3.00SITC of Drain piping with PVC (Sch-40) pipes with fittings duly insulated with 9MM thick Nitrile rubber section with suitable solvent and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc (as per direction of EIC) [ MAKE: ASTRAL / ASHIRVAD / SUPREME / FINOLEX / PRAYAG / ORIPLAST, MAKE OF INSULATION: KFLEX / AFLEX / ARMACELL] | |||||||
| 3.01 | 50 MM NB | 12 | RM | 175 ₹2,100 | 472 ₹5,664 | 419 ₹5,028 | 1 ₹12 Lowest |
| 3.02 | 40 MM NB | 24 | RM | 150 ₹3,600 | 318.6 ₹7,646.4 | 336 ₹8,064 | 100 ₹2,400 Lowest |
| 4.00SITC of Class - VIII grade (120 GSM) GI sheet, for supply & return air duct along with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges. (Make TATA/ SAIL) | |||||||
| 4.01 | 22 SWG | 25 | Sq.M. | 1,365 ₹34,125 | 1,411.28 ₹35,282 | 893 ₹22,325 | 800 ₹20,000 Lowest |
Tender Value
₹13.8 L
EMD Value
₹27,600
Closing Date
8 Sept 2025, 12:00 pmClosed
Exe. Engr.-II, Kol. South Health El. Divn., PWDte
75 D H Road Kidderpore Kol_23
Electrical Installation work for setting up new blood component separation and blood storage unit beside blood bank at ground floor of IPD building at M R Bangur Hospital , South 24 Pgs.- SITC of Air Conditioning System.
2025_WBPWD_892792_1
WBPWD/EE-II/KSHED/Q50/25-26
Open Tender
A/C ORG
Item Rate
45 days
Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹27,600
O/o Exe. Engr., Kol. South Health El. Divn., PWDte
3 Sept 2026
20 Aug 2025
10 Sept 2025
20 Aug 2025
8 Sept 2025
27 Aug 2025
26 Aug 2025
Amount
SITC of Air-cooled ceiling suspended 8.5 TR ductable split units in compliance with latest QCO guidelines complete with highly energy efficient single Scroll Compressors, Copper condenser coil, Copper evaporator coil, unit mounted microprocessor based control panel complete with all accessories suitable to operate on ecofriendly refrigerant R-410A (As per direction of E.I.C) (1 Working + 1 Stand By) (MAKE: VOLTAS/BLUE STAR/MITSUBISHI HEAVY/O-GENERAL)
SITC of Soft/Hard drawn Copper Refrigerant piping complete with thermal insulation by closed cell Nitrile Rubber Insulation, Nitrogen pressure testing, leak testing, vacuumizing, Refrigerant charging and commissioning work by using proper scaffolding and safety arrangements. (As per direction of E.I.C) MAKE: RAJCO / ROYKU / UNIFLOW / NIPPON / MANDEV
1-1/8" dia and 1 mm thick hard drawn Copper Suction Tube with 19mm thick Nitrile Rubber insulation In between Indoor & Outdoor Units.
5/8" dia and 1 mm thick hard drawn Copper Liquid Tube In between Indoor & Outdoor Units
Refrigerant R-410
SITC of Drain piping with PVC (Sch-40) pipes with fittings duly insulated with 9MM thick Nitrile rubber section with suitable solvent and necessary quantities of supports, flanges, bends, elbows, fittings, nut-bolts, gaskets etc (as per direction of EIC) [ MAKE: ASTRAL / ASHIRVAD / SUPREME / FINOLEX / PRAYAG / ORIPLAST, MAKE OF INSULATION: KFLEX / AFLEX / ARMACELL]
SITC of Class - VIII grade (120 GSM) GI sheet, for supply & return air duct along with necessary supports, flanges etc. as required and as per IS 655 and IS-277 standards of following gauges. (Make TATA/ SAIL)
S&F shop fabricated Plenum made out of 18 SWG Class VIII, 120 GSM GI Sheet(Make TATA/ SAIL) and insulated with 25 mm thick duly laminated aluminium foil of mat finish closed cell Nitrile rubber[ MAKE: KFLEX / AFLEX / ARMACELL/SUPREME ]. (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self- adhesive nitrile rubber tape insulation complete by using proper scaffolding and safety arrangements. (As per direction of E.I.C)
S&F of 19 mm thick duly laminated aluminum foil faced closed cell Nitrile rubber (Class “O”) insulation having density 40-60 Kg/CuM on duct after applying OEM recommended suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete in all respect (as per direction of EIC) [ MAKE: KFLEX / AFLEX / ARMACELL/SUPREME ].
S&F of 10 mm thick open cell Nitrile rubber (Class “1”) insulation having density 140-160 Kg/CuM on inaide duct after applying OEM recommended suitable adhesive for Nitrile rubber with nut bult washers complete in all respect (as per direction of EIC). [ MAKE: KFLEX / AFLEX / ARMACELL/SUPREME ]
S&F of underdeck insulation by 50 mm thick TF quality Expanded polysterene slab (24 Kg/Cum) with bituminous adhesive compound, wire, washers etc as required (as per direction of EIC) [MAKE: ASTHA / BEARDSELL].
S&F of powder coated extruded aluminium section supply air diffuser with louvers & GI black volume control dampers. (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of power coated extruded aluminium section return air diffuser with louvers but without volume control dampers complete as required. (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of powder coated extruded aluminium section supply air linear grill with volume control dampers as required (as per direction of EIC) . (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of powder coated extruded aluminium section return air linear grill without volume control dampers as required (as per direction of EIC) (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of opposed blade type Duct Dampers GI manual type. (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of opposed type Collar dampers GI manual type black painted (as per direction of EIC). (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of Mechanical Fire Damper, linkage, fusible links in supply & return air duct as and where required (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of duct mounted Strip Heater Bank made out of SS tube & GI fins divided in to 2 kw in 3 banks (9 kw) including connections with humidistat, airstat, thermostat etc (as per direction of EIC) (Make - Alco/Daspas).
Supplying, fixing, testing & commissioning of powder coated extruded aluminium section fresh air grill in AHU room with aluminium volume control dampers, SS bird screen etc complete as requied (Make - Systemair / Dynacraft / Premire / Caryaire / Airmaster / Air Enterprise).
S&F of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required for the following sizes including painting as towards laying Cu refrigerant pipes, cables, drain pipe etc as per actual requirement at site (as per direction of EIC)
300 mm x 50 x 1.0mm
200 mm x 50 x 1.0mm
S&F of Solid GI (Hot Dip) wire of size 2 length X 8 SWG (as per direction of EIC)
Charges for cutting wall / floor for entry of different sizes duct & pipe lines including mending good the damages including painting with wall matching colour and removal of rubbish as per direction of EIC.
Supply, design, fabrication, installation of MS structural work for AC equipment & accessories like AC Plant, Pipes, Ducts, Cables, Trays, ODU Structures etc : M.S. works in structures/brackets made out from channels, joists, flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. The above structure should be painted 2 coats painting over 2 coats of primer as per direction of EIC.
Charges towards unloading. Loading, lifting, shifting and placement of AC plant on 4f rooftop foundations with the help of hydraulic boom Crane of suitable capacity and counter weight arrangements and height at site.
S&L of 1.1kV Gr. PVC unarmourd copper Cable inside PVC conduits of following sizes:- (Finolex/RR Kabel /Havells)
3 Core 1.5 Sqmm
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability Period - 1 (One) year
Make & model of each and every material to be approved by EIC
TRANSTECH (BID ID -6905715)
Lyric International (BID ID -6896735)
AERIZO TECHNOLOGIES (BID ID -6899452)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .