PROVISION OF DEFICIENT SMQs AT 1WG, AF STN SRINAGAR
2025_MES_694443_1
ceafu-23/2024-25
Open Tender
Civil Works
700 days
Srinagar
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE (P) (AF) Srinagar
₹9.3 L
Yes
15 Apr 2025
22 Jan 2025
9 Apr 2025
22 Jan 2025
1 Apr 2025
13 Mar 2025
Amount
Total amount of Sch 'A' Part-I (Section-I) ( Bldg Work) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Design, Fabrication, Erection and construction of building (Stilt + 6 ) configuration for Married Accommodation as per architectural Drawings and structural drawings designed by the bidder based on input data as provided in the tender documents and as per specification including as per note given below:- Note:- (A) Super structure in steel strcture as per IS 800 and IS 1893-2016 with limit state method using LGSF member confirming to IS standard with RCC foundation Shallow or deep foundation based on the safe bearing capacity (SBC) of the soil as and the structure load as per design criteria specified. (B) Reinforced Cement Concrete - M-30 Design mix and Reinforcement steel of grade Fe-500D/550D TMT bars. (C) Floor/ Deck slab shall be of GI profiled sheet of thickness as per design with RCC laid over it as per IS 11384. (D) Internal and external wall except for bathroom and toilet Area as shwon in shall be of minimum 140 mm thick composed of LGSF member with surface as specified. Space between surface shall be filled with Rockwool insulation of minimum 50 mm thickness of density 48 kg/cum. Bathroom and Toilet shall in PCC Block as shwon. (E) Firefighting cum over head tank of capacity as shown shall be design, construct and finished in GRP as per IS 14399- 1&2 (F) The detailed design and construction shall also include design of internal water supply scheme and sanitary plumbing scheme and supply and fixing of fitting and fixture as specified. (G) The design and construction shall cater for provision of services such as internal electric supply,water supply, sanitary plumbing works, internal heating etc. (H) Confirmatory SBC test as per IS Provisions. (J) Finish of Building as per Schedule of Finish. any missing details of finish shall be as per manufacturuer guidelines and as approved by GE (K) Wall of liftwell however, shall be in 230mm thcik in RCC/ Steel Frame confirming to requirement of relevant IS code and manufacturer for Lift.
Construction of Pump House Building in single storey in RCC frame as per drawings, complete all as specified and as directed by Engr-in-charge
Construction of UG Sump of 50000 ltr capacity sump in RCC as per Drawing No CEAF/STD-34/2002, complete all as specified and as directed by Engr-in-charge
Total amount of Schedule 'A' PART-I (BUILDING WORK)
Total amount of Sch 'A' PART-II (SEC-I) (INTERNAL ELECTRIC SUPPLY WORKS)
Total amount of Sch 'A' Part-II (Section-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F LED Building security Light fitting 25 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB Single Pole 10Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB Single Pole 6 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge
Supply and fixing MCB Single Pole 16 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge
Supply and fixing RCBO for earth leakage, overload & short-circuit protection double pole 32A, 100 mA, AC 240 volt, 10 kA, C - curve comforming to IS-12640-2 & IEC 61009-1 complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge
The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations.The panel Incomers/Outgoings shall have Potential free Contact.All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings). contractor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.
S&F TV concealed socket outlet with grip Modular type 01 Module for Coaxial cable complete set icluding Modular Sunken Box along with Module base cover complete in all respect all as specified and directed.
Total amount of Sch 'A' Part-II (Section-II) (INTERNAL ELECTRIFICATION)
Total amount of Sch 'A' PART-III (SEC-I) ( ROAD, PATH, CULVERT)
Total amount of Sch 'A' PART-IV (SEC-I) (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part-IV (Section-II) (EXTERNAL WATER SUPPLY) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply and fixing cast iron heavy duty Foot Valve screwed/flanged conforming to IS 4038, 50 mm (2”) dia. comlete all as specified and directed by Engineer-in-Charge
M & L for CI fittings comlete all as specified and directed by Engineer-in-Charge
Material and labour for valve chamber (1.5mtr x 1.5 mtr x 0.9 mtr ) (internal ) with brick masonary valve chamber, PCC foundation, plastering and necessary excavation and earth work in any type of soil, MS sheet cover 3 mm thickness along with angle iron frame of size (40 x 40 x 6) mm with locking arrangement & necessary fixing materials like hinges, nut/bolts etc and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc comlete all as specified and directed by Engineer-in-Charge
Material and labour for valve chamber (900mm x 900mm x 900 mm) (internal ) with brick masonary valve chamber, PCC foundation, plastering and necessary excavation and earth work in any type of soil, MS sheet cover 3 mm thickness along with angle iron frame of size (40 x 40 x 6) mm with locking arrangement & necessary fixing materials like hinges, nut/bolts etc and painting to MS cover with one coat of red oxide and two coats of synthetic enamel paint etc comlete all as specified and directed by Engineer-in-Charge
Supply, fixing, testing and commissioning of centrifugal monoblock pump set for water supply set of 5.0 HP having discharge capacity 14000 Ltr/Hr at total head 40 m, self priming type, suction dia 50 mm and delivery data 50 mm, CI impeller, CI valute, SS shaft, carbon/ceramic mechanical seal, electric driven , electric motor 415 V +6%, -15%, 50 HZ, 3 phase, AC supply with class 'F' insulation and temperature riserestricted to class 'B' with IP 55 protection inclusive of PCC foundation comlete all as specified and directed by Engineer-in-Charge
Supply and laying, connecting and testing copper flexible cable, pvc insulated, heavy duty 1100 volts grade 4.0 sqmm 3.0 core laid in trenches passing through existing/new pipe under road crossing, clamping on wall etc. comlete all as specified and directed by Engineer-in-Charge
Supply, testing and commissioning of free standing infront operated fully compartmentalized extendable on both sides Indoor weather & dust vermin proof L.T. Panel board suitable for 3 Phase 4 wire, 415 Volts, 50 Hz, AC supply system housed with incoming and outgoing feeders, bus bars, interconnections etc , factory fabricated with indoor cubicle type totally enclosed .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.. All MCCBs panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate AL/CU cables for the given current ratings with Form B seperation for Incoming MCCB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 2.00 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry. Pump House LT Panel
1.Incoming:- (a) MCCB 40 Amp 16 KA Four pole 415 volts fixed type with thermal magnetic release . It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. It should be thermal based release with adjustable O/L, Adjustable S/C setting Class II front face, 16 KA rupturing cap, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc - 01 Nos .(b) Bus Bar TPN electrolytic Aluminium extensible type as main bus bars of minimum 100 A capacity (As per capacity of corresponding incoming / Bus couplers), and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 36kA .(c). Metering Section - Suitable rated Digital Ammeter in amps-01 No along with resin type CTs as per design ratio with necessary CT shorting link- 03 Nos , digital volt meter in Volts- 01 No , RYB indicating Lamps-03 Nos , Suitable Load mangaer to have a parameters like KW,KWH,KVA,A,V,PF,KVAR,Active and Reactive componentof the power - 1 No .(d) Single Phase preventer and Voltage monitoring Relay -01 No
2. OUTGOINGS (a) MPCB 9- 13 A TP with thermal and magnetic release 415 volts 50 Hz with breaking cap of 100 KA with indicating lamp : On-Trip-Stop with suitable Ammeter along with necesary CTs etc- 02 Nos . (b) Heavuy duty ASD (Automatic Star Delta) Starter suitable upto 5 HP pumps with 4 Pole contactors ,OLR and electronic star delta timer in S.S enclosure with relay range of 5.5 to 8.0 Amps for centrifugal pumps -02 Nos . (All starter should be complete in all respect with TDR ,O/L, S/C and Phase sequence corrector relay etc completein all respect and specified ). (c) MCB SPN 10 Amp 10 KA .-01 Nos Note: Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLSH wires and connections.Earthing all components, frame etc. to a common internal earth bar.Painting all sheet metal works support structure etc.All accessories & supporting structure (Hot Dip Galvanised).The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm.The panel shall be prewired, ready for External Cable termination.All Gland Plate's shall be 3 mm thick removable type.All the CT's shall be cast resin type, with necessary CT shorting link.The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations.The panel Incomers/Outgoings shall have Potential free Contact.3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals.All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.Complete Digital / Electronic interlocking should be provided in the panel for sequence operation of the system to ensure proper safety Suitable sufficient arrangement of LEDs light and provision of blower fans should be provided in the panel.
Total amount of Schedule 'A'Sch 'A' Part-IV (Section-II) (EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' PART-V(SEC-I) (EXTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' Part-V(Section-II) (EXTERNAL ELECTRIC SUPPLY) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
(vii) Suitable CTs of cast resin type with necesaary CT shortlinking should be provieded . - 1 set. OUTGOING (i) MCCB Four pole 100 Amps Icu =16 KA at 415 volts, adjustable type with thermal magnetic release -04 No (O/G) . They should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting. Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc Note: Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLSH wires and connections. All MCCB's are Microprocessor/Thermal Magnetic based (Icu = Ics = 100%) as given in sld, housed in separate compartments, enclosed on sides, with rotating handle. All MCB Icu=10kA where not given/mentioned. Earthing all components, frame etc. to a common internal earth bar. Painting all sheet metal works support structure etc. All accessories & supporting structure (Hot Dip Galvanised). The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm. The panel shall be prewired, ready for External Cable termination. All Gland Plate's shall be 3 mm thick removable type. All the CT's shall be cast resin type, with necessary CT shorting link. The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations. The panel Incomers/Outgoings shall have Potential free Contact. 3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals. All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.
(O/G) ( 3 W + 1S) . They should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting. Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc (ii) Timer switche along with 415 V three Phase contactors 25 Amp rating and MCB 4 Pole 415 V, 25 Amps as incoming and one MCB 4 Pole 415 V, 20 Amps as outgoing incl copper cable for connection and fixing complete all as specified and directed. All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of standard MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer NOTE Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLSH wires and connections. All MCCB's are Microprocessor/Thermal Magnetic based (Icu = Ics = 100%) as given in sld, housed in separate compartments, enclosed on sides, with rotating handle. All MCB Icu=10kA where not given/mentioned. Earthing all components, frame etc. to a common internal earth bar. Painting all sheet metal works support structure etc. All accessories & supporting structure (Hot Dip Galvanised). The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm. The panel shall be prewired, ready for External Cable termination. All Gland Plate's shall be 3 mm thick removable type. All the CT's shall be cast resin type, with necessary CT shorting link. The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations. The panel Incomers/Outgoings shall have Potential free Contact. 3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals. All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 200 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply & Fixing Bracket made out of GI light grade pipe of size upto 40 mm dia, suitable for fixing street light, 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp made out of flat iron of size 40mm x 6mm and 04 sets of nuts,bolts and washers painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified and as directed by Engr-in-charge.
Supply and fix MS box (Kiosk) weather proof made out of FRP sheet of size 325 x 220 x 150 mm including two strip single phase bus bar of aluminium strip with neutral link 32 A rating mounted on insulators of inflammable material and fixed with one Nos MCB SP 240 volts and current rating 2 Amps for controlling street light fittings to be mounted on poles at easily accessible height complete all as specified and directed by Engineer-in-Charge.
Supply & Fix 1.5 sqmm 3 Core Copper cable complete all as specified and directed by Engineer-in-Charge.
Total amount of Schedule 'A'Sch 'A'Sch 'A' Part-V (Section-II) (EXTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' PART-VI (LIGHTENING PROTECTION)
Total amount of Sch 'A' PART-VII (SEC-I) (FIRE FIGHTING SYSTEM)
Total amount of Sch 'A' PART-VII (SEC-II) (FIRE FIGHTING SYSTEM) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply, fixing, testing and commissioning of centrifugal monoblock/ Terrace pump set for fire fighting of 7.5 HP, 2900 RPM, suitable size (suction and delivery) having discharge capacity 900 LPM, total head 30 m, self priming type , CI impeller, CI valute, SS shaft, carbon/ceramic mechanical seal, electric driven , electric motor 415 V +6%, -15%, 50 HZ, 3 phase, AC supply with class 'F' insulation and temperature riserestricted to class 'B' with IP 55 protection with fixing arrangement with suction and delivery pipe including suitable PVC sheet and angle frame for pump shed for protection from rain complete all as specified and directed by Engineer-in-Charge. Note:- Prior approval of design & capcity as per specifications shall be obtained from GE before.
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed with outer sheel shall be made out of 3.15 mm thick sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick sheet .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 2.00 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry and making connections, earth work and PCC foundation complete comprising of the followings and specified herewith:- (forTarrace pumps) : 1.Incoming:- (a) MCCB 25 Amp 16 KA Four pole 415 volts. It should be with adjustable load setting Ir = (0.8 to 1.0) x In,Tcs = 100 % Icu and with adjustable thermal setting. It should be thermal based release with adjustable O/L, Ics=100% Icu, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc - 01 Nos . (b) Bus Bar TPN electrolytic Aluminium extensible type as main bus bars of minimum 200 A capacity (As per capacity of corresponding incoming / Bus couplers), and auxilliary bus bars of suitable capacity with heat shrunk coloured sleeves and i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 36kA . (c). Metering Section - Suitable rated Digital Ammeter in amps-01 No along with resin type CTs as per design ratio with necessary CT shorting link- 03 Nos , digital volt meter in Volts- 01 No , RYB indicating Lamps-03 Nos , Suitable Load mangaer to have a parameters like KW,KWH,KVA,A,V,PF,KVAR,Active and Reactive componentof the power - 1 No . (d) Single Phase preventer and Voltage monitoring Relay -01 No
Note: Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLSH wires and connections. Earthing all components, frame etc. to a common internal earth bar. Painting all sheet metal works support structure etc. All accessories & supporting structure (Hot Dip Galvanised). The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm. The panel shall be prewired, ready for External Cable termination. All Gland Plate's shall be 3 mm thick removable type. All the CT's shall be cast resin type, with necessary CT shorting link. The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations. The panel Incomers/Outgoings shall have Potential free Contact. 3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals. All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site. Complete Digital / Electronic interlocking should be provided in the panel for sequence operation of the system to ensure proper safety Suitable sufficient arrangement of LEDs light and provision of blower fans should be provided in the panel.
Supply and fixing reducer 100/63mm flanged type including fabrication as per site requirement complete all as specified and directed. (Between landing valve / fire brigade inlet and downcomer).
Supply and fixing automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve with suitable reducer for connecting downcomer pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Retro reflective sign board of size 3.0 feet x 1.5 feet made of ACP sheet will be fixed on wall showing alarm point, fire extinguishers, escape routes and emergency power off switches and other points as required on site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Escape Retro reflective sign board made of ACP sheet will be fixed on wall showing fire escape route complete all as specified and directed. Note: The sizes and colours of the exit signs shall be in accordance with IS-9457 & IS-12349.
Supply and fixing LED escape lighting 20 watt fittings with invertor of four hours battery backup normal/trickle charging including point wiring with conductor 1.5 sqmm multi stranded complete all as specified and directed.
Supply, installation, testing & commissioning of Public addressable (PA) system with talk back station in (S+6) MD Accn to accommodate and including following:-
(a) Supply and fixing 10 Watt wall mounted CD Speaker for PA system complete all as specified and directed by Engineer-in-Charge
(b) Supply and fixing 250 watt amplifier complete all as specified and directed by Engineer-in-Charge
(c) Supply and fixing Microphone set complete all as specified and directed by Engineer-in-Charge
(d) Supply and fixing control console for PA system inclding neccesarry wiring , connections and other accessories complete all as specified and directed by Engineer-in-Charge
Supply, Installation, testing and commissioning of dry chemical powder (ABC) type fire extinguishers with operating temperature -20°C to 35°C of 6 Kg capacity, approved make ISI marked, IS: 15683, complete with accessories all as specified and as directed.
Supply, Installation, testing and commissioning of approved make light weight squeeze grip CO2 type fire extinguishers with operating temperature -20°C to 35°C of 4.5 Kg capacity with ISI mark,IS: 15683, complete with accessories all as specified and as directed.
Supply, Installation, testing and commissioning of approved make light weight water stored pressure type fire extinguishers with operating temperature -20°C to 35°C of 9 Kg capacity with ISI mark,IS: 15683, complete with accessories complete all as specified and directed by Engineer-in-Charge.
Supply, Installation, testing and commissioning of approved make Mechanical Foam type fire extinguishers with operating temperature -20°C to 35°C of 9.0 ltr capacity with ISI mark, IS: 15683, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing fire beater with bamboo complete all as specified and directed.
Supply and fixing fire bucket stand with two fire buckets. The stand and buckets are made of GI material, rustproof and anti-corrosive.The outer surface of the bucket and stand are painted red in colour. The stands are equipped with a canopy and legs with all accessories complete all as specified and directed by Engineer-in-Charge.
Total amount of Sch 'A' PART-VII (SEC-II) (FIRE FIGHTING)
Total amount of Sch 'A' PART-VIII (SEC-I) (LIFT)
Total amount of Sch 'A' PART-VIII (SEC-II) (LIFT ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
(b) OUTGOING (i) MCCB Four pole 25 Amps Icu =16 KA at 415 volts, adjustable type with thermal magnetic release -03 No (O/G) ( 2 W + 1S) . They should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting. Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of standard MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLSH wires and connections. All MCCB's are Microprocessor/Thermal Magnetic based (Icu = Ics = 100%) as given in sld, housed in separate compartments, enclosed on sides, with rotating handle. All MCB Icu=10kA where not given/mentioned. Earthing all components, frame etc. to a common internal earth bar. Painting all sheet metal works support structure etc. All accessories & supporting structure (Hot Dip Galvanised). The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm. The panel shall be prewired, ready for External Cable termination. All Gland Plate's shall be 3 mm thick removable type. All the CT's shall be cast resin type, with necessary CT shorting link. The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations. The panel Incomers/Outgoings shall have Potential free Contact. 3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals. All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.
Total amount of Sch 'A' PART-VIII (SEC-II) (LIFT )
Total amount of Sch 'A' PART-IX (STAND BY DG ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply,install ,testing, commissioning of 'Silent type' diesel generating set alongwith having prime power rating of 58.5 kVA,415Volts at 1500RPM , 0.8 lagging power factor at 415 volts suitable for 50 Hz 3 phase system and for 0.85 load factor ,CPCB-4 norms complied, acoustic enclosure,realy panel for automatic starting on main failure (AMF), anti vibration mountings,control panel and foundation.The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame.The DG set power rating indicated above is inclusive of altitude correction factor however the DG Set shall be designed and suitable to operate as per tropical condition of Srinagar (J&K) and for more details on service condition refer particualr specification.The DG set shall be comprising of following item as under:- (a)Diesel Engine : The diesel engine shall be of four stroke cycle multi-cylinder,direct injection water cooled, turbo charged with after cooler, Air to air aftercooling and optimised turbocharger for increased altitude capabilities developing required not less than 74 (BHP) @ 1500 rpm under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation,suitable for generating set application on AMF mode.The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046. The engine shall have the following accessories: (i) Cooling fan and radiator.(ii) DM water cooling systems with pre-mix anti-corrosive additive(iii) Turbocharger.(iv) Fly wheel with fly wheel housing.(v) Electrical engine starter motor (disengagement after start-up) with Batteries.(vi) Battery charging systems.(vii) Stainless steel exhaust flexible elbow.(viii) Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer.(ix) Required filters for fuel, lube oil, air etc.(x) Sets of flexible hoses as required.(xi) Suitable rubber coupling to Alternator with guard.(xii) Suitable Engine controller for protection of the engine.(xiii)Coolant heater and crankcase heater.(xiv) Oil drain Pump (xv) Heavy duty air cleaner.
(b) Engine protections: (i) High coolant temperature warning & trip (ii)Low lubricating oil pressure warning & trip (iii) Low coolant level warning & trip (iv) Fail to crank trip (v) Over crank trip (vi) High and Low speed trip (vii) Low or High battery voltage alarms. (viii)Clogged filter warning and Lack of fuel (ix) High Canopy Temperature (x) Set fail to start protection after failure of the set to start after successfulthree consecutive start attempts. c)Starting system :The engine starting shall be by means of totally enclosed axial type electric starter suitable for 12 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initial exciation complete with battery of suitable AH Sealed Maintenance Free (SMF) Lead-Acid type as required as per specifications.The battery AH and plates shall be as per OEM standards .the connections shall be with copper conductor battery leads of required len (d ) Alternator :58.5 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm self-excited and self regulated through AVR confirming to IS :4722/BS 2613 suitbale for tropical condition with brush less exciter, housed in screen protected drip proof enclosure. The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delivering rated output at rated power factor with,a. Terminal voltage differing from the rated value by not more than +/- 5%. b. Frequency differing from the rated value by not more than +/-0.5%. c. Short circuit capacity of 300% for 10 seconds. d. Over load capacity of 110% for one hour. The insulation class of the Alternator shall be class F/ H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters."
(e) Alternator Protection :Alternator should have following protections (i) Over and Under voltage Under and Over frequency warning and trip (ii) Loss of excitation Over current and Earth Fault and Short Circuit Protection (iii) Unbalanced loads Restricted Earth Fault Protection. Differential protection. Diode Failure. "(f) Voltage regulator :A rapid response voltage regulator shall be provided to regulate the generated voltage.The overall regulations from no load to full load, including cold to hot variation and load power factor of 0.8 lag to unity shall be within 2% of the normal voltage. The excitation system shall be designed to promote rapid voltage recovery following sudden application and disconnection of load." "(g) Acoustic enclousure : The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB norm.Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less than 75 db (A) at a distance of 1 meter.High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ ISO 8528 (Part 10) standard.The canopy has the provision of emergency push button, external to the canopy" "(h) Governor :The governor (Governing Class G2 as per ISO 8528 Part-V) shall be of electronic type suitable for monitoringconstant engine speed within the specified limits for auto parallel and auto load sharing operation." (j) Exhaust : The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB.The exhaust piping and the silencer shall be wrapped with rock wool and/or calcium silicate. The outside shall be neatly wrapped with aluminum cladding. The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms.Suitable supporting structure for installation shalll be provided.
(k) Hot air exhaust (Radiator cooling): GI duct shall be provided for hot air exhaust from DG set up to designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galvanized Iron (GI) Sheet.Galvanised Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall. (l) Fuel Tank : Inbuilt/internal bottom mounted (with-in DG set or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent, drain plug, level indicator, inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated as per tropical condition of Srinagar with 165 Litres approx. capacity or designed capacity shall be suitable for 8 hrs continous operation. (m) AMF Control Panel :The control panel shall be designed for Automatic ON Mains Failure Operationof the Generator sets. The Panel will be totally enclosed, Dust tight, vermin proof, floor mounted, free standing, cubical compartmentalized type with hinged doors, fabricated from 16 SWG CRCA Steel metal having separatecompartments . The Panel will be epoxy painted powder coated with light grey shade, After Seven Tank treatment, and the Panel / compartment will be fitted with the following instrument and pre-wired with colour coded flexible copper cable with ferule Numbers for easy identification & maintenance. The panel shall be complete with interconnections, insulators, two nos. of earthing lugs and with suitable rating of MCCB at both the end & shall incorporate the followings
Total amount of Sch 'A' PART-IX ( STAND BY DG SET )
Total amount of Sch 'A' PART-X (SEC-I) (SEWAGE DISPOSAL)
Total amount of Sch 'A' PART-X (Sec-II) (SEWAGE DISPOSAL ) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
M&L for RCC Septic tanks, designed to carry sewage and sullage water, excavation in any type of soil, RCC M-30 design Mix in walls,base slab,baffle walll , roof slb including beams etc PCC (1:4:8) typed D2 (using 40mm graded crushed stone aggregate) below foundation, Vent shaft, connection etc., complete for 150 users complete all as specified and directed by Engineer-in-Charge
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.50 M deep(effective depth) complete all as specified and directed by Engineer-in-Charge.
Total amount of Sch 'A' PART-X (Sec-II) ( SEWAGE DISPOSAL )
Total amount of Sch 'A' PART-XI (AREA DRAINAGE)
11 Months after completion of work
11 Months after completion of BOQ item No. 18.10 here-in-before
11 Months after completion of BOQ item No. 18.20 here-in-before
03 Months after completion of BOQ item No. 18.30 here-in-before
M M SHAWL Engineers and contractors pvt ltd (BID ID -3267427)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 7.70 MB
Tenderdocument.pdf
Tender Documents • 9.93 MB
Tenderdocument.rar
Tender Documents • 6.84 MB
Download all tender documents and submit your bid