Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | Admitted-Finance |
| 2 | Admitted-Finance ATHWAJAN SRINAGAR 191101 JAMMU AND KASHMIR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 191101 | Admitted-Finance |
Tender Value
₹12 Cr
EMD Value
₹9.3 L
Closing Date
1 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer (AF) Udhampur
HQ Chief Engineer (Air Force) Zone, Military Engineer Services, Air Force Station Udhampur, Mian Bagh, Kashirah, Pin-182101 (J and K)
PROVISION OF DEFICIENT SMQs AT 1WG, AF STN SRINAGAR
2025_MES_694443_1
ceafu-23/2024-25
Open Tender
Civil Works
Lump-sum
700 days
Srinagar
As per Tender Documents
9 documents required · 9 mandatory
₹3,000
GE (P) (AF) Srinagar
₹9.3 L
Yes
13 May 2026
22 Jan 2025
9 Apr 2025
22 Jan 2025
1 Apr 2025
13 Mar 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Total amount of Sch 'A' Part-I (Section-I) ( Bldg Work) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only | |||||
| 1.01 | Design, Fabrication, Erection and construction of building (Stilt + 6 ) configuration for Married Accommodation in steel structure with LGSF member, as per architectural Drawings and structural drawings designed by the bidder based on input data as provided in the tender documents and as per specification including as per note given below:- Note:- (A) Super structure in steel strcture as per IS 800 and IS 1893-2016 with limit state method using LGSF member confirming to IS standard with RCC foundation Shallow or deep foundation based on the safe bearing capacity (SBC) of the soil as and the structure load as per design criteria specified.
(B) Reinforced Cement Concrete - M-30 Design mix and Reinforcement steel of grade Fe-550D TMT bars.
(C) Floor/ Deck slab shall be of GI profiled sheet of thickness as per design with RCC laid over it as per IS 11384.
(D) Internal and external wall shall be of minimum 140 mm thick composed of LGSF member with surface as specified. Space between surface shall be filled with Rockwool insulation of minimum 50 mm thickness of density 48 kg/cum. (E) Firefighting cum over head tank of capacity as shown shall be design, construct and finished in GRP as per IS 14399- 1&2
(F) The detailed design and construction shall also include design of internal water supply scheme and sanitary plumbing scheme and supply and fixing of fitting and fixture as specified. (G) The design and construction shall cater for provision of services such as internal electric supply,water supply, sanitary plumbing works, internal heating etc.
(H) Confirmatory SBC test as per IS Provisions.
(J) Finish of Building as per SChedule. any missing details of finish shall be as per manufacturuer guidelines and as approved by GE | 1 | Each Job | - | - |
| 1.02 | Construction of building for Pump House Bldg in single storey in RCC frame as per drawings, complete all as specified and as directed by Engr-in-charge | 1 | Each Job | - | - |
| 1.03 | Construction of UG Sump of 50000 ltr capacity sump in RCC as per Drawing No CEAF/STD-34/2002, complete all as specified and as directed by Engr-in-charge | 1 | Each Job | - | - |
| 1.04 | Total amount of Schedule 'A' PART-I (BUILDING WORK) | - | - | - | - |
| 2 | Total amount of Sch 'A' PART-II (SEC-I) (INTERNAL ELECTRIC SUPPLY WORKS) | 1 | Lumpsum | 33,04,626 | ₹33,04,626 |
| 3Total amount of Sch 'A' Part-II (Section-II) (INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only | |||||
| 3.1 | S&F LED Building security Light fitting 25 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and directed by Engineer-in-Charge | 12 | Each | - | - |
| 3.2 | Supply and fixing MCB Single Pole 2 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. | 96 | Each | - | - |
| 3.3 | Supply and fixing MCB Single Pole 6 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge | 96 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.04 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 7.70 MB
Tenderdocument.pdf
Tender Documents • 9.93 MB
Tenderdocument.rar
Tender Documents • 6.84 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .