Karnataka Power Transmission Corporation Limited
AEE-2
Supply, Erection,Testing and Commissioning of Nitrogen Injection Fire Protection System(NIFPS) including Civil works required for various Sub-Stations comes under Transmission(W&M) Circle, KPTCL, Munirabad
KPTCL/2023-24/SS/WORK_INDENT324
KPTCL/2023-24/SS/WORK_INDENT324
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL SEE Transmission Works and Mantainance Circle Munirabad
16 documents required · 12 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Should have carried out Erection, Testing and Commissioning of One number of 20MVA or 10MVA,110/11KV Transformer along with Erection of NIFPS on Total Turnkey or Partial Turnkey basis which shall be in satisfactory service for a period of One year prior to date of submission of the Bid. Bidder should get the authorization letter from the Original Equipment Manufacturer OR In case of OEM Should have carried out Erection, Testing and Commissioning of NIFPS on Total Turnkey or Partial Turnkey basis which shall be in satisfactory service for a period of One year prior to date of submission of the Bid.
The Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of opening of bid. OR OEM certificate
Power of Attorney in favor of all the persons signing the documents (If applicable),
Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last five financial years ending on March or December as the case may be, shall not be less than 1.5 times amount tender
₹1,660
₹1.3 L
6 Dec 2023
6 Dec 2023
26 Dec 2023
20 Dec 2023
Tender for Supply, Erection,Testing and Commissioning of Nitrogen Injection Fire Protection System(NIFPS) including Civil works required for various Sub-Stations comes under Transmission(W&M) Circle, KPTCL, Munirabad
Nitrogen Injection fire extinguishing system for Power Transformer below 100 MVA (Required for 20MVA Power Transformer) (Rates as per KPTCL MWSR - 2019; Pg No: 35; Item No: 17.7 & Applicable GST for H...
10C x 2.5 Sqmm Cu. Control Cable (Rates as per KPTCL MWSR - 2019; Pg No: 12; Item No: 1.12.14 & Applicable GST for HSN Code: 8544 is 18%)
4C x 2.5 Sqmm Cu. Control Cable (Rates as per KPTCL MWSR - 2019; Pg No: 12; Item No: 1.12.6 & Applicable GST for HSN Code: 8544 is 18%)
MS Pipe (B-Class) of size 100NB (Rates as per KPWD SR 2018-19; Pg No: 92; Item No: 13.18)
MS Pipe (B-Class) of size 80NB (Rates as per KPWD SR 2018-19; Pg No: 92; Item No: 13.17)
MS Pipe (B-Class) of size 25NB (Rates as per KPWD SR 2018-19; Pg No: 92; Item No: 13.12)
MS Pipe (B-Class) of size 50NB required for supporting (Rates as per KPWD SR 2018-19; Pg No: 92; Item No: 13.15)
Gate/Butterfly valve of size 100NB suitable for 20MVA Tr. (Rates as per KPTCL MWSR - 2019; Pg No: 118; Item No: 7.V.b & Applicable GST for HSN Code: 8481 is 18%)
Gate/Butterfly valves of size 80NB suitable for 20MVA Tr. (Rates as per KPTCL MWSR - 2019; Pg No: 118; Item No: 7.V.b & Applicable GST for HSN Code: 8481 is 18%)
Gate/Butterfly valves of size 50NB suitable for 20MVA Tr. (Rates as per KPTCL MWSR - 2019; Pg No: 118; Item No: 7.V.b & Applicable GST for HSN Code: 8481 is 18%)
Additional materials required for Retrofitting Valves, GI Pipes, Flanges etc as per site condition.
Errection & commissioning of NIFPS (includes modifications works required to connect all the accessories of NIFPS): For 110KV & below classRequired for existing 20MVA Power Transformer (Rates as per K...
Draining out of oil From 20MVA Power transformer collecting the in barrels (Supplied by KPTCL). Shifting the barrels to safe place (in the station peimises only) Covering the opening property to avoid...
Hiring of Crane for shifting of left side Radiator Bank to adopt the 10% Oil drain for the system need as a part of retrofitting work; (Rates as per KPTCL MWSR-2019; Pg No;96; Item NO: 39.B.1) & Appli...
Welding work as a part of retrofitting work for Shifting of left side Radiator Bank to adopt the 10% Oil drain for the system need (Rates as per current market rate)
Filling of Oil to the Conservator Tank with filtering the oil including filtering till attainment of prescribed BDV values including labour, filtering equipment along with accessories. The Minimum BDV...
Miselaneous works etc. as per site condition.
Civil Engineering Charges for Excavation,Concreting,Steel,Centring,Shuttering etc including GST 18% (De...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
ITB.doc
Instructions to Tenderers • 0.10 MB
techno commercial sheet.xls
Techno-Commercial Worksheet • 0.20 MB
IFB.doc
Instructions to Tenderers • 0.15 MB
SCC Final.doc
Tender Document • 0.04 MB
Annexure.doc
Tender Document • 0.06 MB
NIT.doc
Tender Document • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .