| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹1.4 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.7 Cr+₹34.0 L (25.2%)Rejected-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | ₹1.7 Cr+₹34.0 L (25.2%) | L2 | Rejected-AOC NOT LOWEST |
| 3 | L3₹1.7 Cr+₹34.8 L (25.7%)Rejected-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹1.7 Cr+₹34.8 L (25.7%) | L3 | Rejected-AOC NOT LOWEST |
| 4 | Rejected-Technical 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | - | - | Rejected-Technical NOT QUALIFIED as firm is enlisted two class below from the eligible class |
| Sl No | Description | Qty | Unit | Shiva Shakthi Electrical Enterprises L2 | Ashirwad Contractor and Supplier L3 | Roy and Sons Infrastructures L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 50 Hz, energy efficient level - 3,Amendment No.04,2021,confirming to IS 1180 of 2014 (ISI maked and BEE Approved), of capacity 100 KVA ,copper wound ,oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with natural brought out on | 2 | Each Job | 9,50,000 ₹19,00,000 | 11,70,000 ₹23,40,000 | 7,00,000 ₹14,00,000 Lowest |
| 1.10secondary side (LV) and having tappings at +/- 2.5% to +/- 7.5% ,7positions,on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C and shall also comprise of the following accessories :- (a) 01cable box chamber on HV side( primary) consisting of 03 Nos poreclin/epoxy bushing with copper rods complete with nuts and washers, with 01 No cable gland suitable for existing cable. (b) 01 box on LV side( secondary) consisting of 04 Nos epoxy bushing with copper rods complete with nuts and washers with cable glands. (c ) Oil conservator tank with filter type drain plug and oil level gauge. (d) Dehydrating brether with first fill of silica gel. | ||||||
| 1.20(e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate complete. Air release valve plug at four Nos plate soil cast steel detachable rollers. (f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device.(g) 02 Nos earthing terminals on tank cover to facilitate fixing of 50 x6 mm GI earth strip for earthing of body. Rating plate and terminal marking plate. (h) The transformer shall be complete with standard fittings incl plinth foundation for transformer mounting complete allas specified and directed by Engineer-in-charge. | ||||||
| 1.30(j) Extra bushing for natural, in the LT cable box for providing independent set of earthing for natural. (k) First fill of new and unused transformer oil, IS- 335 marked (make: savita / Power Oil) filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes. (l) Providing adequate size and Numbers of channels, embedded in flour, for movement of transformers. (m) Provn for transformer fixing on trolley arrangement system (openable). (Note: Any left out standard accessories which are not mentioned above but for smooth functioning of the transformer shall be included in the quoted rate without any extra cost) | ||||||
| 2.00 | Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure,both Side extensible type compact RMU,11kV, 630 Amps, 21KA (VCB SF6 enclosed) as per IEC-62271, 2 Way motorised RMU(VL+OD), i.e. 1 SF6 insulated VCB as incomer +1 load break switch as outgoing with copper bus bar, manometer,cable boots for VCB and castle key interlocked and necessary PCC foundation work including providing MS channel and MS angle as per manufacturer recommendation along with bottom cable entry and front cable termination of suitable single run 3core 400sqmm HT cable with following specifications and accessories complete all as specified and as directed:- | 1 | Each | 8,00,000 ₹8,00,000 | 7,50,000 ₹7,50,000 Lowest | 9,00,000 ₹9,00,000 |
| 2.10(i) A01 as incoming VCB, A02 Outgoing load break switch with three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism. (ii) Stored energy mech for manual operation - 01 No. (iii) Set of 03 No’s Ring core protection CTs of suitable ratio as per feeder load, 1.0 VA, Class 0.1- 01 set in breaker (Transformer rating 1MVA). Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No inbreaker (iv) Control voltage motor 2x12V DC,12AH battery +24V DC battery charger (v) Self powered OC+EF Protection relay type as per manufacturer recommended with rechargeable - 01 No in each breaker (xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv | ||||||
| 2.20(xii)Enclosure:CRCA sheet powder coated with Siemens grey shade IS 632 Front Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 (xiii) Cable Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 xiv) Cable bushings interface C (400 bolted) , 630A (xv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel. Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No (Note: Any left out standard accessories which are not mentioned above but for smooth functioning of theRMU shall be included in the quoted rate without any extra cost) | ||||||
| 3.00 | Supply & laying HT XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor,11000 Volts grade ( earthed) of cross sectional area 3 Core 95 Sqmm complete all as specified and as directed. | 550 | RM | 995 ₹5,47,250 | 970 ₹5,33,500 | 690 ₹3,79,500 Lowest |
| 4.00 | Supply & laying HT XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor,11000 Volts grade ( earthed) of cross sectional area 3 Core 150 Sqmm complete all as specified and as directed. | 600 | RM | 1,350 ₹8,10,000 | 1,370 ₹8,22,000 | 970 ₹5,82,000 Lowest |
| 5.00 | Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 240 Sqmm 3.5 core complete all as specified and as directed. | 450 | RM | 1,100 ₹4,95,000 | 1,440 ₹6,48,000 | 1,015 ₹4,56,750 Lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
26 Sept 2025, 6:00 pmClosed
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
PRVN OF 01X100KVA TR POWER LINE ALONGWITH ALLIED WK PERMT EST OF GEO REDUNDANT HUB OF 2AHQ SIGREGT AND STC GRND,ENHANCEMENT OF CMD OF HT 6 AND PRVN OF SUBSTN FOR 34MPS AND EXTSERV FOR SIMULATOR CONNECTED ITEMS AT BLDG T-4 HMV WG UNDER GE(C) BANGALORE
2025_MES_727235_1
86435/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹1,000
GE (CENTRAL) BANGALORE
₹2.1 L
5 Jan 2026
22 Aug 2025
3 Oct 2025
22 Aug 2025
26 Sept 2025
5 Sept 2025
22 Aug 2025 - 29 Aug 2025
Amount
Supply, installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 50 Hz, energy efficient level - 3,Amendment No.04,2021,confirming to IS 1180 of 2014 (ISI maked and BEE Approved), of capacity 100 KVA ,copper wound ,oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with natural brought out on
secondary side (LV) and having tappings at +/- 2.5% to +/- 7.5% ,7positions,on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C and shall also comprise of the following accessories :- (a) 01cable box chamber on HV side( primary) consisting of 03 Nos poreclin/epoxy bushing with copper rods complete with nuts and washers, with 01 No cable gland suitable for existing cable. (b) 01 box on LV side( secondary) consisting of 04 Nos epoxy bushing with copper rods complete with nuts and washers with cable glands. (c ) Oil conservator tank with filter type drain plug and oil level gauge. (d) Dehydrating brether with first fill of silica gel.
(e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate complete. Air release valve plug at four Nos plate soil cast steel detachable rollers. (f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device.(g) 02 Nos earthing terminals on tank cover to facilitate fixing of 50 x6 mm GI earth strip for earthing of body. Rating plate and terminal marking plate. (h) The transformer shall be complete with standard fittings incl plinth foundation for transformer mounting complete allas specified and directed by Engineer-in-charge.
(j) Extra bushing for natural, in the LT cable box for providing independent set of earthing for natural. (k) First fill of new and unused transformer oil, IS- 335 marked (make: savita / Power Oil) filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes. (l) Providing adequate size and Numbers of channels, embedded in flour, for movement of transformers. (m) Provn for transformer fixing on trolley arrangement system (openable). (Note: Any left out standard accessories which are not mentioned above but for smooth functioning of the transformer shall be included in the quoted rate without any extra cost)
Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure,both Side extensible type compact RMU,11kV, 630 Amps, 21KA (VCB SF6 enclosed) as per IEC-62271, 2 Way motorised RMU(VL+OD), i.e. 1 SF6 insulated VCB as incomer +1 load break switch as outgoing with copper bus bar, manometer,cable boots for VCB and castle key interlocked and necessary PCC foundation work including providing MS channel and MS angle as per manufacturer recommendation along with bottom cable entry and front cable termination of suitable single run 3core 400sqmm HT cable with following specifications and accessories complete all as specified and as directed:-
(i) A01 as incoming VCB, A02 Outgoing load break switch with three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism. (ii) Stored energy mech for manual operation - 01 No. (iii) Set of 03 No’s Ring core protection CTs of suitable ratio as per feeder load, 1.0 VA, Class 0.1- 01 set in breaker (Transformer rating 1MVA). Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No inbreaker (iv) Control voltage motor 2x12V DC,12AH battery +24V DC battery charger (v) Self powered OC+EF Protection relay type as per manufacturer recommended with rechargeable - 01 No in each breaker (xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv
(xii)Enclosure:CRCA sheet powder coated with Siemens grey shade IS 632 Front Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 (xiii) Cable Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 xiv) Cable bushings interface C (400 bolted) , 630A (xv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel. Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No (Note: Any left out standard accessories which are not mentioned above but for smooth functioning of theRMU shall be included in the quoted rate without any extra cost)
Supply & laying HT XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor,11000 Volts grade ( earthed) of cross sectional area 3 Core 95 Sqmm complete all as specified and as directed.
Supply & laying HT XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured ,electric power cables heavy duty with aluminium conductor,11000 Volts grade ( earthed) of cross sectional area 3 Core 150 Sqmm complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 240 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 150 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 70 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing LT XLPE Insulated PVC bedded, galvanised steel strip on wire armoured with stranded armoured 1100 volts grade under ground heavy duty power electric cable, laid in trenches/duct/on pole including all necessary fixing arrangement such as lugs and termination etc of cross sectional area 35 Sqmm 3.5core complete all as specified and as directed.
Material and labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size,for HT, 25x20cm size complete all as specified and as directed.
M & L for Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 3.00mm thick CRCA Sheet for inner partition walls, independent cabinate with cabinate doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted on angle iron frame of ISA 45x45x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable of 400 Amps, suitablily grouted to PCC complete with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs complete all as specified and as directed with the following accessories:-
Excavation in trenches n. exc 1.5 metre wide and n. exc 1.5 meter depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
Returning, filling in, approved earth including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick after cable are laid and tested complete all as specified and directed.
Removing excavated material / surplus soil to a distance not exc. 50 mtrs & deposited where directed at a level not exc.1.5 mtr above the ground level complete all as specified & directed.
M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified and as directed.
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified and as directed.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable all as per Para 19.75 of SSR Part-I including spreading, levelling, watering and consiolidation complete all as specified and directed.
M&L for steel tubing galvanised 80 mm dia bore, light grade complete with fittings laid in trenches/ fixed along with poles etc as protection to cables complete all as specified and as directed.
M&L for providing trenchless bore using using ultra sounding technique and necessary machine bore of pipe size 150 mm dia suitable for 0.4 mpa working pressure mechanical numatic drilling equipment for passing GI pipe line upto 100 mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications complete all as specified and as directed at site. (Note :1.Quoted rates deems to be inclusive of transportation charges of Drilling machine, connected accessories and passing pipe through bore complete with required accessories.2. Cost of Pipe shall be included in the quoted rate.)
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes including demolition of existing brick work built in cement mortar complete all as specified and directed.
M&L for plastering 10 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface/cable duct/floor complete all as specified and directed.
M&L for Mild Steel angles as fencing port, struct cutting tops in shape including all necessary drilling, notching and reveting etc and similar work confirming Fe-290 Gde E-165 including prepration of steel Surface and applying one coat of red oxide and two coat of synthetic enamel paint complete all as specified and directed..
Supply only chain link fencing galvanised, any size and type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards,rails, straining bolts, etc. Including provision of binding wire complete all as specified and as directed.
Supply and fix mild steel screw bolts (machine made) 11 to 15mm dia with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square 5 cm to 10cm long complete all as specified and as directed.
Material and labour for mild steel round bars for reinforcement 10mm dia and over cut to lengths,bent to shape required including cranking,bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Supply and fix GI barbed wire 2 strand 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standards rails including securing or tying at crossings with and provision of galvanised steel wire staples etc complete all as specified and as directed. (Note - Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.)
M&L for removing of unwanted grass including complete roots & levelling at zero level and laying of stone dust 50 mm thick at an initial layer, then laying 20 mm graded crushed stone aggregate 100 mm thick complete all as specified and as directed. (Note : The quoted rate deemed to be included cleaning and levelling and filling of sub station before laying aggregate.)
S&F Cable jointing Kit 11 KV (earthed) grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and as directed.
Material & labour for Earthing with galvanised steel earth plate electrode 600 x 600x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to GI Strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron. Earth strip protected by G I pipe 50 mm bore (medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm TMT bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as specified & directed .
Supply & installation, testing and commissioning out door type, floor mounted step down transformer, 11KV/ 433 Volts ( At no load) AC 3 ph, 50 Hz, energy efficient level - 3, Amendment No.04, 2021,confirming to IS 1180 of 2014 (ISI maked and BEE Approved), capacity 500 KVA, copper winding, oil immersed, naturally cooled, oil natural- air -natural (ONAN), Class A insulation with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side( LV) in accordance with vector group Dyn- 11 with natural brought out on secondary side (LV) and having tappings at +/- 2.5% to +/- 7.5% , 7 positions, on HV side to be changed by means of hand operated off load tap changer gear. The maximum temprature rise should not exceed 40 degree C in oil and 45 degree C in HV /LV windings when measured by resistance method after countinuous full load run on an ambient temp of 50 degree C and shall also comprise of the following:-
(a) 01 cable box chamber on HV side( primary) consisting of 03 Nos poreclin/epoxy bushing with copper rods complete with nuts and washers, with 01 No cable gland suitable for existing cable. (b) 01 box on LV side( secondary) consisting of 04 Nos epoxy bushing with copper rods complete with nuts and washers with cable glands.(c ) Oil conservator tank with filter type drain plug and oil level gauge. (d) Dehydrating breather with first fill of silica gel. (e) Explosive vent, thermameter pocket on tank cover, oil level guage, oil drain filter valve, lifting hucks, oil filling hole with cap/ plug with connection plate complete. Air release valve plug at four Nos plate soil cast steel detachable rollers.
(f) 01 No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree C with metal guard having maximum perimeter temperatre reading indicator with resetting device. (g) 02 Nos earthing terminals on tank cover to facilitate fixing of 50 x6 mm GI earth strip for earthing of body. Rating plate and terminal marking plate. (j) The transformer shall be complete with standard fittings incl plinth foundation for transformer mounting complete allas specified and directed by Engineer-in-charge. (h) Extra bushing for natural, in the LT cable box for providing independent set of earthing for natural.
(j) First fill of new and unused transformer oil, IS- 335 marked (make: savita / Power Oil) filtered and tested up to 60 KV die electric strength at 2.5 mm air gap between testing electrodes. (k) Providing adequate size and Numbers of channels, embedded in floor, for movement of transformers. (l) Provn for transformer fixing on trolley arrangement system (openable). (m) Provn of foundation to rest transformer all as per manufacturer instruction Note : Any left out standard accessories which are not mentioned above but required for smooth functioning of the transformer is deemed to be included in the quoted rate without any extra cost)
Excavation in post holes (or similar holes) each not exc 0.5cu. m, in soft / loose soil, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surface complete all as specified & directed
M & L for Plain Cement Concrete (1:4:8) type D-2 using 40mm graded stone aggregate in foundation and mass concrete all as specified & directed
M & L for Pre-cast Cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregates as in solid blocks masonary exceeding 10 cm in width and setting in cement mortar (1:6) all as specified and directed.
Supply and install H T 11 KV outdoor gang operated air-break switch Triple pole ,mechanically operated vertical mounted on insulator and steel frame with opearting mechanism worked from ground level rating up to 200 Amps including testing for smooth functioning complete all as specified and directed
M&L for Aluminium Conductor, Steel Reinforced of any size including tightening and bindingh with new binding wires to insulators all as specified & directed.
M&L for Pin type porcelain insulator, vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade all as specified & directed.
S&F Disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts all as specified & directed.
M&L for Anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old device all as specified & directed.
S & F Expulsion fuse above 50 & up to 100 AMPS capacity, 11000 Volts all as specified & directed.
S&F lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 65 Kilo Amps suitable for 11000 Volts line all as specified & directed.
Supply, erecting and fixing steel tubular swaged pole (410 SP – 55), 11 mtr long, with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole, fix in in true vertical position, complete all as specified and directed
M & L for Fabricate, supply, install, connect, test and commissioning of L T feeder pillar box/panel board/out door type, minimum size 500x 450x 50mm, made out of CRCA sheet 3.15 mm thick with M S angle iron frame of 75x75x6 mm frame, 3 phase, 4 wire, 440 Volts, AC, 50 HZ with TPN bus bar of suitable 1200 Amps capacity with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details, indicating lamps with toggle switches duly wired including ELR with CBET locking arrngement including suitable foundation and platform for mounting the panel with space for and including panel comprising of the following switch gears all as specified & directed:- (a) ACB drawout type with thermal magnetic 4 pole 50KA, 800Amps 415 Volts 50 Hz - 01 (in coming) (b) Multi FUNCTION METER (LED Display) to read KWH, Amps,Volts and frequency etc of each phase (c) Indicator LED Type for RYB set of 3 - 01 set
Supply, install, testing & commissioning of outdoor type, welded stainless steel tank with IP-67 protection for SF-6 Tank and IP 54 protection for outdoor enclosure,both Side extensible type compact RMU,, 12kV, 630 Amps, 21KA (VCB SF6 enclosed) as per IEC-62271, 2 Way RMU(2VL), i.e. 1VCB+1 VCB 1 incoming+1outgoing, 630 A with copper Bus Bar consisting of 04 No’s SF6 insulated Motorized VCB of 11KV, 630Amp with overload and earth fault protection, capacitive voltage indication, Manometer, cable boots for VCB and castle key interlocked and necessary PCC foundation work including providing MS channel and MS angle as per manufacturer recommend along with bottom cable entry and front cable termination of suitable single run 3core 400sqmm HT cable with following specifications complete all as specified and as directed. (i) A01 as incoming VCB, A02 Outgoing VCB with three position isolator /earthing switch, bus bars, interlocking earth bars and stored spring energy mechanism. (ii) Stored energy mech for manual operation - 01 No. (iii) Set of 03 No’s Ring core protection CTs of suitable ratio as per feeder load, 1.0 VA, Class 0.1- 01 set in breaker. (Transformer rating 2MVA) Capacitive voltage indication fixed type VPIS 9- 15KV - 01 No inbreaker
(iv) Control voltage motor 24 DC-01 Nos each Breaker (v) Self powered OC+EF Protection relay type as per manufacturer recommended with rechargeable - 01 No in each breaker(xi) Impluse withstand voltage: To earth and between phases: 75KV Insulation level: -Power frequency 1 min:28 Kv (xii) Enclosure: CRCA sheet powder coated with Siemens grey shade IS 632 Front Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 Cable Cover: CRCA sheet powder coated with Siemens grey shade RAL 7035 xiii) Cable bushings interface C (400 bolted) , 630A (xiv) Bushings outside cone interface C for connection of external busbars 2x12V DC battery + charger scheme R-Y-B phase indication. Additional equipment delivered separately or mounted in respective panel. Set of coupling bus bars along with suitable coupling kit - 01No, Operating Handle - 01 No
M & L for Design, fabricate, supply, testing and commisioning of Automatic Power Factor Correction (APFC) PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER of capacity 40 KVAR (10 x 4) complete with standard fittings complete all as specified and directed.
M & L for Design, fabricate, supply, testing and commisioning of CPRI approved factory made Automatic Power Factor Correction (APFC) Panel, vertical type, floor mounted, 3phase 4 wire, 440volts, AC, 50 Hz double door, out door type, angle iron 75x75x10mm frame covered with CRCA sheet including cabinets, cabinet doors for capacitors , capacitor contactor, MCCB's, bus bar, cable trays, PF controller, metering equipments, with MCCB 250Amps incoming, TPN bus bar of suitable capacity, 150 KVAR capacitors MD-XL (5,10,15,20,25,30) range controlled by capacitor contactor with MCB, 8 Step power factor controller, PVC insulated, heat shrink colour coated sleaves, mounted horizontally with porcelain insulators, sufficient air vent provisioned for all three sides, stickers/ plastic plates for switch gears complete, indicating lamps with toggle switches duly wired including ELR with CBET locking arrangement including suitable foundation and platform for mounting the panel with space complete all as specified & directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including necessary earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 mtr, PCC (1:4:8) type D-2 (using 40 mm graded sand stone aggregate) in the base and foundation upto ground level and PCC (1:2:4) type B-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint and including making alternate white and black strips 30 cms height (05 Nos strips) numbering the poles by 2" height 06 Nos letters complete all the metallic surfaces all as specified and directed by Engineer-in-Charge.
Supply & laying XLPE insulated, PVC sheathed, strip armoured electric cable with stranded aluminium conductor working voltage upto1100 volt of 10 Sqmm 2-core as per IS 7098 Pt I in trenches, culvert, through pipe etc including connecting both end with proper size of alluminium lugs duly crimped with die press crimping device and cable gland complete all as specified and directed.
Material and labour of Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as directed and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
Material and labour for switches air break, gang operated Triple pole, mechanically operated,mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 Amps,GOD of 12 insulator type worrking voltage 11000 Volts complete all as specified and directed.
M&L for GI tubing Bracket 40mm dia, medium grade 1.5 mtr lenth, bent to 120° shape for fixing street light fitting including grouting / fixing with Flat iron 2-Nos clamps required size,including necessary bolts complete all as specified and directed.
Supply & fix in repair FRP junction box (weather proof) of size 240 x 130 x 110mm including single phase connector arrangement alongwith suitable clamps including MCB SP.5 Amps 10 KA rating c curves, fixing with flat iron clamps, nuts and bolts complete all as specified and directed. Make : Sintex or equivalent
Supply and fixing LED street / building light fitting, 1x60 watts with highly effective and efficient luminaire robust design, IP-66 fixed on walls with all fixing accessories such bend pipe, square/round blocks, clamps/screws, etc complete all as specified and directed.
Supply and fix, in repair PVC insulated three core,1.5 Sqmm cables with copper conductor copper flexible cable with earth conductor complete all as specified and directed.
Material and labour of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp,6600 volts complete all as specified and directed.
M & L for Design, fabricate, supply, testing and commisioning of CPRI approved factory made LT Panel Board double door, out door type fabricated out of 3.15mm thick CRCA sheet steel for outer body and 3.15mm thick CRCA Sheet for inner partition walls, independent cabinet with cabinet doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted, angle iron complete frame of ISA 45x45x5mm with minimum height of legs 45 cm, minimum IP-54 protection, comprising of solid aluminium bus bar 4 strips suitable for 300 Amps, suitablily grouted in PCC 1:2:4 foundation block with internal wiring, epoxy powder coated, connections of cable ends with suitable size of aluminium cable lugs with the following accessories:-
(a) INCOMING (i) MCCB 160 Amps, 4 Pole, 415 V, 25 KA (ICS=ICU 100%) - 01 No (b) OUTGOING (i) MCCB 100-160 Amps, 4 Pole, 415 V, 25 KA - 02 Nos (ii) MCCB 63 Amps, 4 Pole, 415 V, 25 KA - 01 Nos (iii) MCB SPN 32 Amps-01 Nos (iv) Digital volt meter - 01 No (v) Digital ammeter - 01 No (vi) Current Transfer (CT) - 3 Nos (vii) Phase indicator lamp (RYB) set of three - 01 No
Excavation in trenches n. exc 1.5 mtr wide and exc 1.5 mtr but n. exc 3m depth for pole / cable / foundation etc including getting out in soft /loose soil complete all as specified and directed.
Supply and laying sub class B brick, well burnt laid breath wise along with the length of cable laid in trenches over sand cushioning laid for cable protection all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregates as in foundation filling and mass concrete including form work for poles all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in coping etc including necessary form work for poles all as specified and directed.
M & L for road cutting excavation in trenches for laying HT/LT UG cable in pipe not exc 45 cm wide and n.exc 90 cm depth or as per site requirement making good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished to match with adjoining surfaces all as specified and directed.
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM (1:4) as in foundation of equipment, platform, ramp, supporting pillars of pipes incl demolistion of existing brick work built in cement mortar complete all as specified and directed.
M&L for Plastering 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface/cable duct/floor complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor of cable size 150 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor of cable size 150 Sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor of cable size 150 Sqmm complete all as specified and directed.
Supply and fix Sheet metal enclosure (ISI marked) distribution board VTPN, 415 volts, 8 way double door type with 250Amps MCCB incoming, 250 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified & directed
Supply and fix Sub main wiring with 4 runs of 10 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn ithrough non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10sqmm single core PVC insulated & unsheathed copper conductor as contineous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion complete all as specified and directed. (Note : Five run 10sqmm cable and one run of conduit altogether measured as one unit)
Supply and fix TPN Earth enclosure with three pin and earth plug with socket complete with one MCB TPN 63 Amp and fixed flush in wall surface, and tested on completion complete all as specified & directed.
Supply and fix Switch socket combination flush type 6 &16 Amps 3/5 pin universal multipurpose complete all as specified & directed.
M & L for Fabricate, supply, install, connect, test and commissioning of CPRI approved factory made LT Panel Board double door, out door type, Panel frame of angle iron 75x75x10 mm 3 phase, 4 wire, 440 Volts, AC, 50 HZ with 1200Amps TPN bus bar of suitable capacity, covered with 3.15mm thick CRCA sheet for outer body and 3.00mm thick CRCA Sheet for inner partition walls, independent cabinet with cabinet doors for MCCBs, Bus Bars, cable trays, metering equipment, vertical type floor mounted with PVC insulated heat shrink colour code sleeves, mounted horizontaly with porcelain insulators, sufficient air vent provision for all the three sides, stickers / plastic plates for switch gear details complete , indicating lamps with toggle switches duly wired , ELR with CBET locking arrngement including suitable foundation and platform for mounting the panel with space including comprising of the following switch gears:-
(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators 1200 Amps for phases and 1200 amps for neural set of 4 for RYB &N set of 04 -01 set (b) ACB draw out type with thermal magantic 4 pole 50KA,800Amps,415Volts capacity -01 (in coming) (c) MCCB FP 415 Volts 50 Hz 250 Amps 36KA repturing capacity- 04 Nos (out going) (d) Multi Function meter (LED Display) to read KWH, Amps,Volts and frequency etc of each phase (e) Indicator LED Type for RYB set of 3 - 01 set
Shiva Shakthi Electrical Enterprises (BID ID -3430220)
Ashirwad Contractor and Supplier (BID ID -3436311)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .