Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 327 328 III FLOOR INDRAPRASTH TOWER INDORE | INDORE | INDORE | MADHYA PRADESH | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.2 L+₹55,000 (4.74%)Rejected-AOC 7TH FLOOR DN 12 SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700091 | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹26,600
Closing Date
5 Sept 2020, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNED
Office of the Executive Engineer Kolkata North Electrical Division PWDt P 5 CIT Road 2nd Floor, Moulali Kolkata 700 014
SITC of Lift for G Plus2 Annex building at North Calcutta Polytechnic Kolkata 700002
2020_WBPWD_292736_1
WBPWD/EE/KNED/NIT-08 of 2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
NCP KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹26,600
9 Oct 2020
12 Aug 2020
7 Sept 2020
15 Aug 2020
5 Sept 2020
15 Aug 2020
120 days
Amount
SITC of Automatic Lift (as per manufacturer design & as per detailed specification below conforming to IS) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall/floor if any etc to complete as reqd. (Make :OTIS/ KONE/ SCHINDLER) Type :- MRL Lift . Load: 13 -Passenger/884 Kg. Control: Microprocessor based with AC variable voltage & variable frequency (VVVF) Machine:- Energy efficient machine, Gearless without Machine Room Postion of Machine Room : Directly above the lift shaft Speed:- 01 Mtrs./Sec Floor Served :- 3 Landing :- 3 All on same side Total Rise : 7 Mtr. Operation : Microprocessor based implex full collective with or without attendant. Signals: Digital car position indicator , car travels direction indicator in car & at all landing with call registration indicator. Leveling accuracy ± 5mm(Micro levelling arrangement)
CAR Car inside :1100mm(W) x2000mm(D) Car Entrance : Clear Opening 900 Mm (W) x2000 mm(H) protected with car door. Car Enclosure : Stainless Steel Sheet(20 SWG) with Hairline finish with hand rail Car Ceiling & Lighting : Stainless Steel with hairline finish with LED lighting and Fan Car Ventilation: Pressure fan with anodised aluminium grill. Car Flooring : Decorative granite flooring (As per direction of EIC and according to this Department's Order). Car Door: Stainless Steel Centre/Side opening automatic door provided with V3F controlled door drive system. Landing Door : Stainless steel centre opening automatic door provided with V3F controld door drive system. Door Opening : Automatic power oprated door with full length Photocell assembly light curtain sensor.
PROTECTIVE DEVICES & OTHER ACESSORIES ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of Power failure/Single phasing/others. Overload Protection : Full loaded with overload protection. On overloading the lift care will not start with door remaining open and give audio display indication Emergency lighting in car: Battery operated emergency lighting in the lift car. Intercom system: Battery Operated intercom system in lift car, Machine Room & Control Room Emergency Alarm: Battery operated alarm bell system in lift car and control room. Fireman switch: Fireman switch at main landing terminal. Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator. Main rope - As per manufacturer's standard conforming to IS.
DIMENSION OF SHAFT & POWER SUPPLY Available shaft Dimension 1860mm x 2430 mm Pit Depth :1600 mm Overhead : 4800 mm Electric power supply : AC 415 Volt 3 Phase, 50 Hz, terminated in machine room as per IS. Note: Rates should be quoted inclusive of minor civil works, wall / floor cutting, for making holes, chiseling etc. and mending good the damages to the original finish.
SCHINDLER INDIA PRIVATE LIMITED
stage.html
html • 0.04 MB
technical_544725.pdf
PDF • 0.56 MB
techsummary_544725.pdf
PDF • 0.56 MB
finance_544725.pdf
PDF • 0.56 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_544725.pdf
PDF • 0.60 MB
NIT_08.pdf
PDF • 0.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .