Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC GROUND FLOOR 66A BLOCK F GALI NO 4 HARI NAGAR EXTN PART 2 66A BADARPUR BADARPUR SOUTH EAST DELHI SOUTH DELHI DELHI 110044 UDYAM DL 09 0032523 | SOUTH EAST DELHI | DELHI | 110044 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹28.2 L+₹30,520.98 (1.09%)Rejected-Finance | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹29.5 L+₹1.6 L (5.81%)Rejected-Finance NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹30.7 L+₹2.8 L (9.95%)Rejected-Finance NO 92 KUVEMPUNAGAR 2ND STAGE JALAHALLI EAST BANGALORE 560 014 | 560014 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 5 | L5₹30.8 L+₹2.9 L (10.3%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹65,800
Closing Date
9 Feb 2023, 6:00 pmClosed
Garrison Engineer MAF Jalahalli
Garrison Engineer MAF Jalahalli Bangalore 560013
8743SPECIAL REPAIR TO WASH ROOMS OF P 496 AT 16 TS AT AFS UNDER GE M AF JALAHALLI BANGALORE
2023_MES_574648_1
8743/E8
Open Tender
Civil Works
Item Rate
152 days
Garrison Engineer MAF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹65,800
15 May 2023
12 Jan 2023
11 Feb 2023
12 Jan 2023
9 Feb 2023
27 Jan 2023
12 Jan 2023 - 19 Jan 2023
Amount
Sch "A" Part I B&R works Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames).
Supply and fixing steel ventilators/windows with top/side hung shutter including hinges, steel pegs, stay etc complete all as specified and directed.
Supply and fixing 4mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
Material and labour for framed work such as grills with ends of bars shouldered and/or riveted or forged into spikes, hold fastsframed guard bars etc complete conforming to Fe 290, Gde 165
Cutting holes in Stone walls in cement mortar exc one brick but not exc two brick thick wall for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required.
Material and labour for providing two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description, over 10cm in width or girth,not otherwise described and all as specified and directed.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Supply and fixing factory made solid PVC moulded door shutter 28 mm thick (stiles), with 2,4 or 6 raised panel design with 3mm thick high pressure compact laminate on both sides of approved color as infill with C type GI or 40 x 20 x 19 of MS pipe as stiffner complete all as specified and directed by Engr-in-Charge
Supply and fixing 150mm Al anodised, barrel tower bolts of extruded section complete
Supply and fixingExtruded aluminium alloy handles, fabricated type,anodised 100mm
Supply and fixing 100 mm long Stainless steel Butt hinges extruded.
Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises.
Material and labour for 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes under floor and all as specified and directed.
Material and labour for colored non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and all as specified and directed.
Material and labour for Dubbing out 15mm thick on irregular face of walls in CM 1:6 on brick work or concrete/stone surfaces.
Material and labour for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc.
Material and labour for Colored Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match
Demolition of cement concrete (unreinforced) any description and in any position not otherwise specifically provided for.
Material and labour for 10 mm thick Cement plaster on surfaces of concrete in CM 1:4 on roof surfaces
Providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating Brushbond Roof Guard in 3 coats of application @ 0.5 litre/m2/coat, The Product should have following Properties: Solid Content : 70 % Tensile strength (ASTM D 412) : 1.10 MPa Elongation (ASTM D12): 100 % Resistance to ageing due to UV radiation: 1000 hours No change Rapid Chloride Penetration : Very low Resistance to Algae growth: Passes, Zero Rating/ Permeability (mm) : 5.0 Water vapour transmission: 6.0 g/ m² h No. of coats : 3 (minimum) Adhesive bond strength : > 0.92 N/mm2 Make : FOSROC
Material and labour Providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in roof, chajjas, coping, bed blocks and similar work including necessary form work.
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar.
Material and labour for Rendering 15mm thick in CM (1:4) on external surfaces of walls mixed with water proofing compound on stone masonry/concrete surface finished even & smooth without using extra cement.
Material and labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified.
Material and labour for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement as internal surfaces of walls.
Material and labour for treating with three coats of whitewash on new surfaes of walls incl necessary preparation to give uniform and smooth finish all as specified.
Material and labour 10 mm thick rendering on fair faces of concrete surfaces on ceiling in CM 1:3 and finishing the surfaces even and smooth without using extra cement.
Material and labour preparation of plastered surfaces of ceiling and applying three coats of white wash on new surfaces.
Material and labour for Rendering 15mm thick in CM (1:3) on sunken concrete floor surfaces mixed with integral water proofing compound finished even & smooth without using extra cement.
Material and labour for Applying bitumen blown 85/25 grade, applied hot, to concrete surfaces at the rate of 1.2kg per sqm per coat.
Supply and fixing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 4mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified
Material and labour for Plain cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in filling and mass concrete
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc. but excluding washer facing dressed stone work and precast concrete articles.
Material and labour for brick work with sub class 'B' modular bricks straight or curved on plan exc. 6.00m mean radius built in cement mortor 1:6.
Material and labour for rendering 15 mm thick in CM 1:6 on fair faces of brick work/stone masonry finished even and smooth without using extra cement.
Supply only integral water proofing compound.
Making arrangement of scaffolding in buildings, cutting of small trees/plants at the stem, removal of the roots of the plants by using acids, cutting around the spot for removing the roots any size and making good with cement mortar 1:3 or with PCC 1:2:4 including finishing with existing complete all as directed by Enginner-in-charge.
Supply and fix in repairs viterous china squatting pan Orrisa pattern size 580 x 440 mm white with "P" and "S" trap front or back inlet etc including provision of PCC (1:5:10) concrete complete all as specified and as directed
Supply and fixing in repairs viterous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steels chromium plated on aluminium hinging device and connecting to 'P' or 'S' incl connecting flush pipe with flushing rim all as specified
Supply and fixing 32mm dia chromium plated cast copper alloy flush cock, screwed down, screwed for pipe complete all as specified
Supply and fixing in repairs low density polyethylene pipe of pressure rating 6 kg/sq cm of 40 mm bore
Supply and fixing 75 mm bore PVC (SWR) floor trap in repairs with grating incl jointing with solvent cement
Supply and fixing 5.50mm thick looking mirror of selcected quality glass mounted on 12mm thick BWR phenol bonded ply back with PVC beading allround frame fixed to wooden plug with chromium plated brass screw & cup washer complete all as specified and as directed
Supply and fixing in repairs CP shower rose with 125mm arm all as specified
Supply and fixing in repairs brass chromium plated towel rail 20mm dia D type 60 cm long .
Supply and fixing CP soap disk fixed with screw to wall complete
Supply and fixing Angular Stop valve 15mm of CP any colour high pressure screwed for iron pipe and fixed for 15mm bore
Supply and fixing Stop valve 15mm CP any colourwith long shank concealed type all as specified and directed
Supply and fixing Bib taps fancy type chromium plated with crutch or butterfly handle screwed down screwed for galvanised iron pipe or for brass ferrule and fixed complete for 15 mm bore
Supply and fix vitreous China urinals, Half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) incl coupling complete all as specified and as directed.
Supply and fixing Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms)
Taking out steel water tubing and connections including cleaning for refixing 15 mm dia.
All as per item No 52 hereinbefore but 20mm dia.
All as per item No 52 hereinbefore but 25/32 mm dia.
All as per item No 52 hereinbefore but 40/50mm dia.
Material and labour for in repairs15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
All as per item No 56 hereinbefore but 20mm dia.
Material and labour for in repairs 32mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Material and labour for in repairs 40mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Supply and fixing Rotational moulded Polyethylene water storage tank - 2000 liters capacity (cylidrical vertical with double layered, threaded top cover) hoisted and fixed in position all as specified in SSR part I.
Supply and fixing in repairs 40 mm dia gun metal gate valve with Iron wheel screwed both ends for Iron pipe of following sizes
Supply and fixing in repairs 20 mm dia gun metal gate valve with Iron wheel screwed both ends for Iron pipe.
Supply and fix in repairs 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall complete all as specified and as directed.
Supply and fix in repairs 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall complete all as specified and as directed.
Supply and fix 110mm dia PVC bend any radius complete all as specified and as directed.
All as per item No 65 above but 75mm dia
Supply and fixing PVC (SWR) bends of any radius with access door bore of pipe 75 mm
All as per item No.67 above but bore of pipe 110 mm with access door
Supply and fixing PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 110 mm
Supply and fixing PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 75mm
Supply and fixing PVC (SWR) branch piece, single(single Y) equal or unequal with access door bore of pipe 75mm
Supply and fixing PVC (SWR) branch piece, single (single Y) equal or unequal with access door bore of pipe 110mm
Supply and fixing PVC (SWR) branch piece, double (double Y) equal or unequal with access door bore of pipe 110mm
Supply and fixing PVC (SWR) Vent cowl 110mm
Supply and fixing PVC (SWR) Vent cowl 75MM
Re-fixing old steel water tubing and connections in new or old position (walls, ceiling, floors etc) 15 mm dia
All as per item No 76 hereinbefore but 20mm dia.
All as per item No 76 hereinbefore but 40mm dia.
Supply and fixing in repairs PVC connection 15 mm bore, 450 mm long complete with both ends unions.
Raking out joints / pointing to squared rubble masonry coursed or uncoursed built in cement mortar or cement lime mortar
Keyed pointing on squared rubble masonry coursed or uncoursed in cement mortar 1:4
Dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings.
Taking Down existing water proofing treatment with tar felt including cement plaster/HP tiles/concrete 50mm from roof surfaces such as and disposal of the rubbish from the premises beyond 250m complete all as specified and as directed.
Material and labour for Providing cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in roof coping concrete, laid to slope for further treatment all as specified and directed
Material and labour for 10 mm thick Cement plaster on surfaces of concrete in CM 1:4 on roof surfaces
Material and labour for water proofing treatment on horizontal and vertical surfaces, Applying oil bound bitumen primer @ 0.20Kg/Sqm and providing 4mm thick APP modified waterproofing membrane weighing not less than 4.0 kg/Sqm reinforced with non woven polyester matt weighing not less than 160 gm/Sqm ,including minimum 10cm side over lap and 15 cm end lap , incl another coat of hot blown bitumen 85/25 @1.2kg/sqm applied over membrane and finally finished with a coat of bituminous paint @ 100 gms/sqm all specified and directed and testing complete on completion.
Material and labour for Dismantling water tanks of capacity 2000L and removing to store
Supply and fixing wash basins, Vitreous China (flat back or angle back type) white, flat back, size 600x480mm, including brackets,32mm waste coupling PTMT, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed
Supply and fixing pillar tap with capstan heads chromium palted screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore
Material and labour for 75 mm thick PCC type B2, 1:2:4 (40 mm graded aggregate used) finishing the surface even and smooth with using extra cement, all as specified and as directed.
Forming Construction joints 30 mm deep x 10 mm wide filled with sealing compound grade A
Material and labour for Complete removal of existing treatment, preparation of old surfaces for further coat on walls all as specified
Material and labour for priming the surfaces with Chalk whiting, on old plastered surfaces, prepara-tory to distempering
Material and labour for preparation of primed surfaces of wall, applying two coat of oil emulsion distemper and all as specified and directed.
Material and labour for preparation of old surfaces of wall including scrapping down, smoke soot, efflorescence slats, treading oil, greasy spots etc and applying one coat of white wash and all as specified and directed.
All asper Item No 95 herein before but in ceiling
Material and labour for preparation of old surfaces of wall including scrapping down, smoke soot, efflorescence slats, treading oil, greasy spots etc and applying one coat of cement based emulsion and all as specified and directed.
Material and labour for preperation of old painted surfaces of steel and iron work of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint any tint complete all as specified and directed.
All as per Item No 98. herein before but on wood surfaces
Supply and fixing in repair stainless steel wire cloth of 0.36mm dia of wire and average width of aperture 1.40mm with staples or old serviceable fillets complete.
Supply and fixing in repair 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed
Material and labour for point wiring for ligh point /bldg security light point with two runs of FRLS cable PVC insulated unsheathed , 1100 volt copper multistranded conductor 1.5 sqmm grade in and including non metalic rigid 20mm medium grade PVC conduit with all accessories along with fixing arrangements on surface/ in wall / on ceiling/ including pvc suitable rectengular box with top cover plate not less than 3mm thick fixing on wall surface for fix switches / sockets / regulators etc all as per site require with 1.5 sqmm PVC insulated multistrand copper earth continuity conductor connecting to common earth dolly complete all as specified and directed.
All as per item No. 103 but here-in-before One exhaust fan point controlled by one 5 Amp switch
All as per item No. 103 but here-in-before One 5 Amps socket point on same board with other switches
All as peritem No. 103 but here-in-before One 5 Amps socket point on independent board
All as peritem No. 103 here in before but for using 4.0 sqmm for one 3/5 pin 15 Amps socket out let on independent board and multistarnded insulated with one copper earth continity conductor of size 4.0 qmm all as specified and directed .
Supply and fixing Switch piano flush type single pole and one way 230 volts 5 Amps all as specified
Supply and fixing Switch socket combination multi purpose universal 3/5 pin 5 Amps flush type 240 volts all as specified..
Supply and fixing Switch socket combination outlet 5/6 pin universal 15 Amps multi purpose flush type universal pattern 230 volts all as specified.
Supply and fixing PVC ceiling rose two to three plate surface and jumbo type all as specified.
Taking down userviceable Exhaust fan, Metal Body 225/300mm Size sealing cable end, dismantling blades and Refixing to Existing place after make serviceable, repainting and connection complete all as per site required and as directed by Engr-in-Charge.(Note :Quoted rates of items for taking down, servicing, repainting, hanging and electrical connection complete of Exhaust fan all are inclusive in Each Job)
Rewinding of unserviceable Exhaust fan with any type any size upto 300mm with copper wire , bush, insulation etc and it's make serviceable and refix at existing place/site complete all as specified and as directed.
Supply and fixing LED light fitting,4 feet ,1x20 watt 230 Volt, decorative PC body Compact appearance, simple and versatile in nature makes it as long lasting, efficient solution for offices and other spaces. Efficacy : 100 lumen/watt including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed including taking down old fitting .
Supply and fixing LED light fitting, 2 feet ,1x10 watt 230 Volt, PC body Compact appearance, simple and versatile in nature makes it as long lasting, efficient solution for offices and other commercial spaces. Efficacy : 100 lumen/watt with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting .
Material and labour for sub main wiring with 2 single core stranded copper conductor unsheathed PVC insulated cable 1100V grade, 4 sq mm drawn through and including 20MM size of non-metallic PVC rigid conduit with 2.5sqmm copper conductor cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed including taking down old U/S wiring. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Supply and fixing MCB DB(distibution board) 4 Way SPN(single pole and neutral) Double Door single phase made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
Supply and fixing MCB SPN 32 Amps, 10 KA,240V, 50Hz, 'B' Series single pole&Neutral complete all as specified and as directed.
Supply and fixing MCB SP 6 to 32 Amps SP 10 KA,50HZ, 240V, 'B' Series complete all as specified and as directed.
Material and labour for New Earthing complete with galvanised iron plate earth electrode 600mm×60mm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C2 chamber with RCC 1:2:4 type B1 in cover slab with GI protection including indicated testing on completion all as specified and directed by Engineer-in-Charge and including taking down old earthing material.
GANGARAM CONSTRUCTIONS
SRI GANESH ENTERPRISES
BYRAVESHWARA CONSTUCTION
SRI MAHALAKSHMI CONSTRUCTIONS
S CHANDRASHEKAR (SREE BUILDERS)
LAKSHMI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .