| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.6 LAccepted-Finance | 1 | Accepted-Finance Single Bid opened | |
| 2 | Rejected-Technical | - | Rejected-Technical Due to Administrative resons |
Tender Value
Refer Docs
EMD Value
₹12,730
Closing Date
20 Jan 2023, 6:00 pmClosed
Executive Engineer(C), BSNL Hubballi
O/o the Executive Engineer, BSNL Civil Division, 2nd floor CTO Building Pinto Road HUBBALLI.
Essential Repairs in Ground Floor, First floor and External repairs for Telephone Exchange Building at J.C. Nagar, HUBBALLI under Hubballi BA (2nd call).
2023_BSNL_141373_1
20/NIT/BSNL/CD/HBL/2022-23
Open Tender
Civil Works - Buildings
Works
90 days
Hubballi
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash) BSNL Hubballi
₹12,730
Hubballi
8 Feb 2023
12 Jan 2023
23 Jan 2023
12 Jan 2023
20 Jan 2023
12 Jan 2023
12 Jan 2023 - 19 Jan 2023
19 Jan 2023
Amount
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish dumping ground within 50m lead excluding the cost of scafolding
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material within 50 metres lead:
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:
Of area 3 sq. metres and below
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5mm, made out of foamsheet, mitred at corners and jointed with brackets of 15x15mm M.S. square tube, verticl frame to be reinforced with 19x19mm M.S. square tube , of 19 guage EPDM rubber gasketweather seal to be provided through out the frame.The door frame to be fixed to the wall using M.S.screws of 65/100 size complete as per manufacturers specification and engineer incharge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x19mm for styles and 15x15 mm for top and bottom rails. M.S frame shall have a coat of steel primer of approved make and manufacture MS frame covered with 5 mm thick heat moulded PVC C Channel of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to tje styles and rails with 7 mm (5 mm + 2mm) thickx 15 mm wide PVC 75 mm shall be tapered on both sides to form lock rail shall be provided both sides the panel . 10mm (5mm x 2) thick 20mm wide cross PVC sheet to be provided as gap insert for top rail & bottom rail panelling of 5mm thick both side PVC sheet to be fitted in the M.S.Frame welded/sealed to the styles & rails with 7 mm 9 5mm +2mm)thick x15 mm wide PVC sheet beading on inner side adhesive.an additional 5 mm thick PVC strip of 20mm width is to be stuck on the interior side of the C channel using PVC solvent adhesive etc complete as per direction of engineerincharge, manufacturers specifications& drawing
30mm Thick Prelaminated PVC door shutter.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm M.S gusset plates at the junctions and corners all necessery fittings complete, including applying a priming coat of approved steel primer a) using M.S.angles 40x40x6 mm for diagonal braces.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc. complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand) sqm
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing chicken mesh to the wall surface with nails, binding wire, all complete as directed by the Engineer in charge.
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 sqm)
Special repairs to damaged RCC members such as slabs, columns, beams, stairs, chajjas etc. using specialised repair products of polymer/epoxy base of Dr. Fixit/Fosroc/ Krishna Conchem/Sika or equivalent.The following steps shall be followed. (1) Applying Alkaline rust converting primer. To remove the corrosion from steel. (2) Applying Anticorrosive protective coating to avoid further corrosion and thus protecting the steel. (3) Treating with Epoxy latex system compound for bonding the old and new mortars. (4) Finishing/ filling with poilymer modified repair mortar/microconcrete compound as per requirement . Note:1) rate includes the cost of removing/ dismantling loose mortar/plaster/concrete before applyng the repair products.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.50 Sq.meter and under including cutting the raking out joints and prepring and plastering the walls complete,including disposal of rubbish to the dumping ground within 50 meters lead.excluding the cost of schaffolding
With cement mortar 1:4 (1 cement : 4 fine sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty
Float glass panes of thickness 4 mm (weight not less than 10kg/sqm)
Renewal of old putty of glass panes (length)
Refixing old glass panes with putty and nails
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Taking out existing Aluminium door shutter, repairing and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40mm dia. M.S. tube 1.5m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Easoning of Collapsible Gate including greecing alround the frame, welding the members wherever necessary and oiling the joints to move make easy movement etc., complete as per the direction of Engineer-in-charge.
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing Gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand :4stone aggregate 10mm and downggauge ) including finishing with cement mortar 1:3 (1 cement : 3 fine sand ) as per standard design
In 75x75 mm deep chase
Removing weeds grown on walls including labour, scafolding and Any T& P required all complete as directed by the Engineer in charge.
Cleaning terrace/ chajja including cleaning the chokage of rain water pipes and disposal of waste materil beyond the Exchange premises all complete as directed by the engineer incharge.
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with bricks of class designation 50 including grouting with cement mortar 1:4 (1 cement : 4 fine sand)
Easoning of steel windows by oiling to hinges welding to shutter /frame etc where ever required etc all complete as directed by the Engineer in charge.
steel windows of area up to 1.80 sqm
Cleaning Man Holes of all depths including using boning rod, removing sludge,waste material and disposin off the same beyond the quarters premises etc all complete as directed by the Engineer in charge
a) 90 Cm x 80 cm manhole
Cleaning chokage of drainage line including using of boning rod ,removing of waste material, and disposal of the same beyond the qtrs premises etc all complete as directed by the engineer incharge.
cleaning ceramic tiles/glazed tiles dado with soapwater/ acid to remove patches of dust ,filling the joints with matching pigment etc all complete as directed by the Engineer in charge.
Locking of steel Bars to the existing slabs and beams wherever required including drilling the required size of holes to a required depth, applying and filling fosroc chemical to the bars and holes carefully etc., complete as per the direction of the Engineer-in-charge,
For 8 to 20mm dia bars
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
Providing and fixing STAINLESS STEEL JALI (GRATING) withor without hole for waste pipe for floor /Nahani trap of size ( Note Grating to be placed at 10mm below floor level a)100 mm dia ( weight not less than 100 grams
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia .Pipes.
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour
15 mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing Brass Patti valve of approved quality, High or low pressure,
25mm nominal bore
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.
25mm nominal bore. Weighing not less than 62 gms.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .