| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 11 26 BHAGWANPURA KISHANGARH CHANDIGARH | L1 | Accepted-AOC l1 | |
| 2 | L2₹16.6 L+₹18,315 (1.12%)Rejected-Finance 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L2 | Rejected-Finance l2 | |
| 3 | L3₹16.9 L+₹56,465 (3.45%)Rejected-Finance 2ND FLOOR PLOT NO 338 UDHYOG VIHAR PHASE IV GURUGRAM 122015 HARYANA | GURUGRAM | HARYANA | 122015 | L3 | Rejected-Finance l3 | |
| 4 | Rejected-Technical DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | - | Rejected-Technical Tech compliance is not proper | |
| 5 | Rejected-Technical PLOT NO 89 90 INDUSTRIAL AREA PHASE I PANCHKULA HARYANA 134113 | PANCHKULA | PANCHKULA | HARYANA | 134113 | - | Rejected-Technical enlistment not attached |
| Sl No | Description | Qty | Unit | Insat Techno Services L2 | Netromics Engineering Solutions Private Limited L3 | AVNET Solutions L1 |
|---|---|---|---|---|---|---|
| 1.00Works Details | ||||||
| 1.01 | [23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate] | 850 | Metre | 120 ₹1,02,000 Lowest | 159 ₹1,35,150 | 142 ₹1,20,700 |
| 1.02 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] | 2,500 | Metre | 62 ₹1,55,000 | 51 ₹1,27,500 Lowest | 65 ₹1,62,500 |
| 1.03 | SITC of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI/B501AP/IV ,Bosch FAP-425-OT plus MS400B,Siemens OP921 plus DB11E.. | 164 | Each | 3,315 ₹5,43,660 | 3,550 ₹5,82,200 | 3,245 ₹5,32,180 Lowest |
| 1.04 | SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). (Make: Morley HM/RHSE/I plus MI/B501AP/IV, Bosch FAH-425-T plus MS400B, Siemens HI921 plus DB11E). . | 1 | Each | 3,100 ₹3,100 Lowest | 3,480 ₹3,480 | 3,145 ₹3,145 |
| 1.05 | SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens XMS-S.. | 21 | Each | 4,390 ₹92,190 | 4,100 ₹86,100 Lowest | 4,180 ₹87,780 |
| 1.06 | SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO, Bosch FLM-420-RLV1-E, Siemens XTRT-R. | 1 | Each | 5,350 ₹5,350 Lowest | 5,925 ₹5,925 | 5,400 ₹5,400 |
| 1.07 | SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Morley MI DMMI, Bosch FLM-420-O1I1-E,Siemens XTRT-M. | 1 | Each | 5,350 ₹5,350 Lowest | 5,925 ₹5,925 | 5,400 ₹5,400 |
| 1.08 | SITC of Addressable Loop powered sounder with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05 plus MI/B501AP/IV,Bosch FNM-420, Siemens FDS224R. | 21 | Each | 9,600 ₹2,01,600 | 7,200 ₹1,51,200 Lowest | 9,500 ₹1,99,500 |
| 1.09 | SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX.. | 22 | Each | 2,190 ₹48,180 | 2,025 ₹44,550 | 1,780 ₹39,160 Lowest |
Tender Value
₹15.0 L
EMD Value
₹29,921
Closing Date
23 May 2025, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Estimate for fire fighting system and fire Alarm system at CHC Satnali in Distt Mohindergarh. (Pdg. Fire Alarm System only)
2025_HRY_447201_1
202524E23AE9 3734 4100 AA79 75566DB647D3668BAR
Open Tender
Civil Works
Works
120 days
SATNALI
2 documents required · 2 mandatory
₹1,000
₹29,921
Yes
7 Aug 2025
16 May 2025
26 May 2025
16 May 2025
23 May 2025
16 May 2025
Amount
Works Details
[23.6.6.2]MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS pipe of 25 mm dia. [Through Rate]
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
SITC of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements: Drift Compensation feature and Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make: Morley HM/PTSE/I plus MI/B501AP/IV ,Bosch FAP-425-OT plus MS400B,Siemens OP921 plus DB11E..
SITC of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector). (Make: Morley HM/RHSE/I plus MI/B501AP/IV, Bosch FAH-425-T plus MS400B, Siemens HI921 plus DB11E). .
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make : Morley HM/MCP/Glass, Bosch FMC-210- DM-G-R, Siemens XMS-S..
SITC of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make : Morley MI/DCMO, Bosch FLM-420-RLV1-E, Siemens XTRT-R.
SITC of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make : (Morley MI DMMI, Bosch FLM-420-O1I1-E,Siemens XTRT-M.
SITC of Addressable Loop powered sounder with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer - in Charge of work. Make: Morley WSO-PR-N05 plus MI/B501AP/IV,Bosch FNM-420, Siemens FDS224R.
SITC of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer-in-Charge of work. Make Pearl/Giolite/OMEX..
SITC of minimum 1000 Mtr. Range Siren generatorprovided at the roof of the building with separate power suppl, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer incharge. Make: National/Kheraj ..
SITC of PVC unsheathed s/c stranded ( ISI marked ) copper conductor cable 1100v grade in existing pipe excluding cost and erection of pipe but including connection etc. with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer – in charge of work PVC unsheathed copper size 1.5 sq mm single core MAKE FINOLEX/POLYCAB/Plaza..
SITC of Wiring for PA system of size 2 Cx 1.5 sq.mm of FRLS insulated copper conductor single core 1100 volts grade cables in existing surface/recessed M.S./PVC conduit etc. as complete as required. Make Finolex/Havells/Plaza..
Supply and erection of ABC Dry power type fire Extinguishers of 5 kg. capacity duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire).
Supply and erection of CO2 type fire extinguishers of 4 Kg capacity duly hang on wall with necessary hook complete in all respect (Make: Safex/Minimax/ Ceasefire) .
SITC of 2 loop Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of required loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 2 Serial Ports. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. The panel should also have IP30 or better protection. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Make: Morley ZX5SE,Bosch Avenar 2000, Siemens Cereberus...
Insat Techno Services (BID ID -1265398)
Netromics Engineering Solutions Private Limited (BID ID -1266233)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .