Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Feb 2026, 9:30 pmClosed
Sanjay Gandhi Institute of Trauma and Orthopaedics
SUDHA RANI
SUPPLY OF ARTHROSCOPY IMPLANTS -HIGH END
SGITO/2025-26/IND0055
SGITO/2025-26/IND0055
Open
Two Tender Document System(Two Cover)
SGITO Director Office Bengaluru
3 documents required · 0 mandatory · 3 optional
Performance statement for past 3 years
Self Declaration for not Black listed in GoK
Authorization by the manufacturing Company
Manufacturing License of the Manufacturer
End User Certificate from other Institutions / Hospitals for past 3 years
Service Centre in Bangalore / Karnataka / Staff availability in your company
GST Registration Copy / PAN No.
GST Registration Copy / PAN No.
Balance sheet statement for the past three years
Annual Turnover of minimum 5.00 crores for the last three years certified by Chartered Accountant
USFDA / CE Certificate as per tender document
Tender form
₹500
₹50,000
6 Feb 2026
6 Feb 2026
23 Feb 2026
12 Feb 2026
12 Feb 2026
scopy104 Adjustable loop Button for ACL Reconstruction 1.00 No
scopy111 All Suture Anchors for Instability and Cuff Repair 1.00 No
scopy135 Integrated pump tubing (inflow-outflow tubing) to be used arthroscopy pump for pumping saline during arthroscopy procedures. should be compatible with shaver system in Ot or supplier has to provide machine on case to case basis. 1.00 No
scopy134 shaver 4mm hood shaped fluted shaver burr to be used with arthroscopic shaver system. Blade should be compatible with shaver system in Ot or supplier has to provide machine on case to case basis. 1.00 No
scopy133 Disposable hook shaped radio frequency bipolar probes with suction for ablation during arthroscopy. Probes should be hand controlled. Probes should be compatible with machine in OT or supplier has to provide machine on case to case basis. 1.00 No
scopy132 shaver 2mm-2.5mm shaver burr to be used with arthroscopic shaver system for small joint arthroscopy. Blade should be compatible with shaver system in Ot or supplier has to provide machine on case to case basis. 1.00 No
scopy131 shaver 2mm-2.5mm shaver blade to be used with arthroscopic shaver system for small joint arthroscopy. Blade should be compatible with shaver system in Ot or supplier has to provide machine on case to case basis. 1.00 No
scopy130 Disposable 90 degree and 50 degree radio frequency bipolar probes with suction for ablation during arthroscopy. Probes should be hand controlled. Probes should be compatible with machine in OT or supplier has to provide machine on case to case basis. 1.00 No
scopy129 shaver 5mm/5.5mm barrel shaped fluted shaver burr to be used with arthroscopic shaver system. Blade should be compatible with shaver system in OT or supplier has to provide machine on case to case basis. 1.00 No
scopy128 shaver 4mm-4.5mm blade to be used with arthroscopic shaver system. Blade should be compatible with shaver system in Ot or supplier has to provide machine on case to case basis. 1.00 No
scopy127 Suture lasso 45 degree left for instability repair. Should be supplied with one nitinol shuttle or loop to be used with it. 1.00 No
scopy126 Suture lasso 45 degree right for instability repair. Should be supplied with one nitinol shuttle or loop to be used with it. 1.00 No
scopy125 Disposable nitinol needle for scorpion or equivalent suture passer for cuff repair. Instrument should be provided on case to case basis. 1.00 No
scopy124 cannula 8mm x 90mm for shoulder arthroscopy. Should have threads on entire body of cannula. Should be supplied as sterile pack. 1.00 No
scopy123 cannula 8mm x 75mm for shoulder arthroscopy. Should have threads on entire body of cannula. Should be supplied as sterile pack. 1.00 No
scopy122 cannula 6.5mm x 75mm for shoulder arthroscopy. Should have threads on entire body of cannula. Should be supplied as sterile pack. 1.00 No
scopy121 cannula 5.5mm x 75mm for shoulder arthroscopy. Should have threads on entire body of cannula. Should be supplied as sterile pack. 1.00 No
scopy120 Self Punching All Suture for Medial Row cuff Repair 1.00 No
scopy119 Self punching Knotless Anchor System- PEEK 1.00 No
scopy118 Self Punching Medial Row Anchor for Cuff Repair 1.00 No
scopy117 Metal Anchors for Instability and Cuff Repair 1.00 No
scopy116 All Suture anchor with tapes for Instability repair 1.00 No
scopy115 Peek anchor forBankart Repair- Smallest in the market 1.00 No
scopy114 Knotless anchor for bankart/SLAP 1.00 No
scopy113 Self Punching Lateral Row anchor for Cuff Repair 1.00 No
scopy112 Peek Anchor for Cuff Repair 1.00 No
scopy110 Inside Out Meniscal Repair system-suture & tapes 1.00 No
scopy109 Inside Out Meniscal Repair system- Cannulas 1.00 No
scopy108 Inside Out Meniscal Repair system- Handle 1.00 No
scopy107 Inside Out Meniscal Repair system 1.00 No
scopy106 All Inside Meniscal repair 1.00 No
scopy105 Biocomposite screws for ACL reconstruction 1.00 No
scopy044 Small Anchor (All Suture) - Dia 1.2mm,Loaded with . 2.0 Fiber wire, 2 Needle,Solid handle with Safety Knob,Use 1.2mm Seft Stop Drill bit and Sleeve 1.00 No
scopy042 All Suture Anchor (For Bankart Repair) - Dia. 1.5mm, Length 8mm, . 2 Fiber wire, Single Loaded Fiber wire, 2 Needle, Solid handle with Safety Knob, Minimal Drill Dept of15mm, Use 1.5mm Auto Stop Drill bit and Sleeve 1.00 No
scopy041 All Suture Anchor (For Bankart Repair) - Dia. 1.5mm and 1.8mm, Length 8mm, . 2 Fiber wire, Single Loaded and Double Loaded, Solid handle with Safety Knob, Minimal Drill Dept of 15mm, Use 1.5mm and 1.8mm Self Stop Drill bit and Sleeve 1.00 No
scopy040 KNOTLESS ANCHOR (For Bankart Repair) - Peek Optima Material, Dia 3.5mm, Auto Stop Mechanism, Anti clock rotating Removable technic, .2 Fiber Tape 2 No. loaded Capacity, Use with 2.9mm AutoStop Drill Bit with Slive 1.00 No
scopy039 KNOTLESS ANCHOR (For Bankart Repair) - Peek Optima Material, Dia 2.8mm, Auto Stop Mechanism, Anti clock rotating Removable technic, One .2 Fiber wire and One .2 Fiber Tape loaded Capacity, Use with 2.2mm AutoStop Drill Bit with Slive 1.00 No
scopy038 PEEK ANCHOR (For Bankart Repair) - Dia 3.0mm, Peek Optima Material, Ultra Fiber wire Material, Anchor is Loaded with.2 Fiber wire, Single Loaded Anchor, 2 Needle, Use with 2.4mm seft stop drill bit with sleeve 1.00 No
scopy037 PEEK ANCHOR (For Bankart Repair) - Dia 3.0mm, Peek Optima Material, Ultra Fiber wire Material, Anchor is Loaded with .2 Fiber wire, 1 Loaded, 2 Loaded fiber wire, Use with 2.4mm seft stop drill bit with sleeve 1.00 No
scopy036 TITANIUM ANCHOR ( For Bankart Repair) - Dia 3.0mm, Ultra Fiber wire Material, 2 Needle available, Anchor is Loaded with .2 Fiber wire, 1 loaded Fiber wire, Self tapping and self drill Anchor,Titanium Tip Material 1.00 No
scopy035 TITANIUM ANCHOR (For Bankart Repair) - Dia 3.0mm, Ultra Fiber wire Material,Anchor is Loaded with .2 Fiber wire,Single Loaded Anchor, Double Loaded Anchor,Self tapping and self drill Anchor,Titanium Tip Material 1.00 No
scopy033 LATERAL ROW ANCHOR (For Rotator Cuff Repair) - Peek Optima Material, Peek + Titanium Tip, Self Tapping Anchor, Auto Stop Mechanism Anti clock rotating Removable technic 8 Suture loaded Capacity, Dia 5.mm Direct Anchor Punching 1.00 No
scopy031 PEEK Anchor (For Rotator Cuff Repair) - Peek Optima Material, Ultra Fiber wire Material, Cortical and Cancellous Threaded Design, Anchor is Loaded with .2 Fiber wire, 4 Needle, 2 loaded, Use with 4.4mm Punch, size 5.5mm 1.00 No
scopy030 PEEK Anchor (For Rotator Cuff Repair) - Peek Optima Material, Ultra Fiber wire Material, Cortical and Cancellous Threaded Design, Anchor is Loaded with .2 Fiber wire, 2 loaded and 3 loaded, Use with 4.4mm Punch, size 5.5mm, 5.0MM 1.00 No
scopy027 Anchor Titanium (For Rotator Cuff Repair) - Self Tapping Anchor , Fully Threaded Anchor, Loaded with 2 fiber wire, .2 Size Fiber wire, Ultra High Molecular Fiber wire,Headless titanium anchor,Size 5.5mm 1.00 No
scopy028 Anchor Titanium( For Rotator Cuff Repair) - Self Tapping Anchor, Fully Threaded Anchor,Loaded with 3 fiber wire, .2 Size Fiber wire,Ultra High Molecular Fiber wire,Size 5.mm 1.00 No
scopy048 REVISION JUMBO BUTTON 1.00 No
scopy047 ACROMIO CLAVICAL BUTTON 1.00 No
scopy046 Distal Radial ULNAR JOINT BUTTON 1.00 No
scopy045 Small Anchor (All Suture) - Dia 1.8mm knotless, Loaded with 1.8 with Fiber wire, 2 Needle, Slolid handle with Safety Knob, Use 1.2mm Seft Stop Drill bit and Sleeve 1.00 No
scopy043 Small Anchor (Titanium) 1.00 No
scopy034 All Suture Anchor ( For Rotator Cuff Repair) 1.00 No
scopy032 LATERAL ROW ANCHOR (For Rotator Cuff Repair ) - Peek Optima Material,Dia 5.mm, Auto Stop Mechanism, Anti clock rotating Removable technic, 8 Suture loaded Capacity, Use with 4.4mm Seft Stop Drill Bit and Sleeve 1.00 No
scopy029 Anchor Titanium( For Rotator Cuff Repair) 1.00 No
scopy026 FIBER TAPE 1.00 No
scopy025 MENISCAL REPAIR NEEDLE 1.00 No
scopy024 FIBER WIRE 1.00 No
scopy023 STAPLE 1.00 No
scopy022 BIO SCREW 1.00 No
scopy021 TITANIUM SCREW 1.00 No
scopy020 PEEK SCREW 1.00 No
scopy019 TIBIAL ADJUSTABLE LOOP PEEK 1.00 No
scopy018 TIBIAL ADJUSTABLE LOOP TITANIUM 1.00 No
scopy017 FEMERAL ADJUSTABLE LOOP PEEK 1.00 No
scopy016 FEMERAL ADJUSTABLE LOOP TITANIUM 1.00 No
scopy015 FEMERAL FIXED LOOP 1.00 No
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BIDDING DOCUMENT FOR ARTHROSCOPY HIGH END IMPLANTS.docx
Others - Bidding Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .