| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹38.3 L+₹7,383.90 (0.19%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹40.9 L+₹2.7 L (7.04%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹41.1 L+₹2.9 L (7.51%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹43.1 L+₹4.8 L (12.7%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹37.5 L
EMD Value
₹75,085
Closing Date
25 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 864 EWS
GE 864 EWS BB CANTT SRINAGAR
PROVISION OF STORAGE ACCN AT AGE BR-III AND SPECIAL REPAIR TO SEWAGE LINE OF OFFICER MESS OF 2 FOD UNDER AGE B/R-III GE 864 EWS AT BB CANTT, SRINAGAR
2021_MES_497879_1
864/WS-53/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
BB CANTT SRINAGAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹75,085
Yes
21 Mar 2022
28 Dec 2021
27 Jan 2022
28 Dec 2021
25 Jan 2022
11 Jan 2022
60 days
Amount
Demolition of brick work or stone masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) 150mm dia (internal bore) set in cement mortar and removing of demolished pipe to a distance exceeding 100m and depositing as complete all as specified and directed.
Ditto all as per serial item No. 4.00 described here-in-before but 200mm dia complete all as specified and directed.
Ditto all as per serial item No. 4.00 described here-in-before but 250mm dia complete all as specified and directed.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft /loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and directed.
Removing excavated material/ soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains of 100mm dia (internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) smooth finished and reforming benching as required complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains of 150mm dia (internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) smooth finished and reforming benching as required complete all as specified and directed.
M&L for cutting into existing manholes for connecting new drains of 200mm dia (internal bore) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) smooth finished and reforming benching as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4, complete all as specifed and directed.
M&L for plain cement concrete (1:2:4) type B1, (using 20mm graded crushed stone aggregate) as in coping etc including weathering, slightly rounded or chamfered angle and throating including use and waste of formwork (straight or curved) complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D2, (using 40mm graded crushed stone aggregate) asin foundations, filling and mass concrete complete all as specified and directed.
M&L for rendering 15mm thick on other than fair face of brick work in cm 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for cutting of road as required (Not more than 9.50m length) for laying RCC pipe line including repair/make good with filling of earth, boulders, WBM, BM etc. with top surface finished with 30mm thick ready mixed patch filler, complete all as specified and as directed.
M&L for reinforced concrete pipes, 150 mm dia class NP2, with collars laid in trenches and jointed complete all as specified and directed.
Ditto all as per serial item No. 18.00 described here-in-before but 200mm dia complete all as specified and directed.
Ditto all as per serial item No. 18.00 described here-in-before but 250mm dia complete all as specified and directed.
M&L for cement concrete bed to drain pipes 150mm bore including packing under and hunching against the sides of pipes after they are laid and tested, in cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) complete all as specified and directed.
Ditto all as per serial item No. 21.00 described here-in-before but 200mm dia complete all as specified and directed.
Ditto all as per serial item No. 21.00 described here-in-before but 250mm dia complete all as specified and directed.
M&L for providing pre-cast RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in cover slab for manhole etc including necessary form work and set in CM 1:4 complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for framed work such as in angle iron frames for manhole covers and similar work confirming to Fe 290 grade E-165 complete all as specified and as directed.
M&L for mild steel bars round bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for fixing chainlink fencing and as in handles for manhole cover Fe-410 (Gde.E-250) complete all as specified and directed.
S&F 110 mm bore dia PVC (SWR grade) pipes single socketed, in any length with rubber ring joints, fixed to walls, floors etc including taking down of old pipes complete all as specified and directed.
S&F PVC (SWR grade) bends any radius 110 mm fixed etc complete all as specified and directed.
M&L for cleaning of manholes of various depth as follows including taking off manholes covers and re-fixing the same after cleaning dewatering and dislodging manually or mechanically removing the waste materials and sludge to a distance n.exc 50m and depositing where directed at site in borrow pits. (The rates includes labour for earth work/excavation and removal of surplus soil to a distance not exceeding 50 metres):-
Manholes not exceeding 1.5m deep and of any size (length and width)
Manholes exceeding 1.5m deep and of any size (length and width)
M&L for cleaning of septic tanks by disludging inlet chambers, removing the waste materials by manually or mechanically (contaminated water and sludge/solid waste) and sludge to a distance to near by suitable distance as directed and depositing in the borrow pits as directed at site (disposal of water/solid waste/sludge paid separately in indl item) (The rates included labour for earth work/excavation and removal of surplus soil from pits to a distance n.exc 50 metres) :-
25 to 75 users
above 75 to 150 users
above 150 users
Disposal of sludge/waste materials removed from Septic tank to a suitable place distance not more than 10 Km by covered vehicle all as specified and directed.
M&L for cleaning of drain pipes of SGSW/RCC of any dia (internal bore) including manholes channels by rodding manually or mechanically from manhole to manhole for cleaning eye and well flushing with water after cleaning (The rate include for taking off manhole cover and re-fixing the same after cleaning/removing the waste materials and sludge to a distance near by suitable distance as directed and depositing in the borrow pits as directed at site (The rates also include for earth work/excavation and removal of surplus spoil for borrow pits) complete all as specified and directed.
M&L for chequered cement concrete tiles 25 cm x 25 cm x 22 mm thick, set, jointed and pointed in neat cement slurry (with grey cement and pigment) as in floors over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 30mm thick sand cushion complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck slab and in shelves complete all as specified and directed.
Ditto all as per serial item No. 25.00 described here-in-before but 5mm dia and over upto and including 10mm dia TMT bars as in stirrups, spacers and binders complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter rough finished surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchion, of square, rectangular in rough finished surfaces of concrete complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick in rough finished surfaces of concrete complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F rolled mild steel as in roof trusses (framed), trussed, purlins, pole, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan built in CM 1:6 complete all as specified and directed.
M&L for 10 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plasted wall surface and applying two coats of cement base paint over one coat of white wash complete all as specified and directed.
M&L for preparation of new plasted wall surface and applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified and directed.
S&F pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in filling of pressed steel door frame and hold fast block etc complete all as specified and directed.
S&F 35 mm thick 2nd class soft wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically presssure treated complete all as specified and directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed ot welded incl 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing 75mm c/c welded to F I frame work, incl other fittings, hinges, handles tarred hold fasts PCC blocks etc. complete all as specified and directed.
M&L for 12 mm thick Prelaminated particle board, interior grade, pelaminated one side with decorative choice lamination & other side balancing white lamination fixed with aluminium snap beading in partition or with screws to timber frame work complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F galvanised steel wire cloth, 0.36 mm nominal dia of wire and avg with aperature 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section 150mm size complete all as specified and directed.
S&F Butt hinges medium weight cold rolled of 125mm size complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or ectruded sections & fixing bolts & sliding bolts is extruded sectins or cast aluminium ally of size 200mm complete all as specified and directed.
S&F 150mm long anodised aluminium handles, cast type complete all as specified and as directed.
S&F 150mm size floor door stopper of aluminium alloy body complete all as specified and directed.
S&F 100 mm size Aluminium anodised hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws all complete all as specified and directed.
M&L for broken stone or boulder hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed.
M&L for providing 50 mm thick cement concrete (1:3:6) type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection finished even and smooth without using extra cement complete all as specified.
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base in CM 1.4, 15mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab 20-25 mm thick as in riser of steps, skirting, dado and pillar laid over backing coat 15 mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) dark shade, polished, area of each tiles not exceeding 0.36 sqm, in floors & skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for 100mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in sub base all as specified and directed
M&L for 4mm thick non asbestos fibre cement building board size 600x600mm HPSC (High pressure steam cured) incl GI Based powder coated snap grid/section (Make-Armsstrong) size 600mm x 600mm with main runner 38x24x0.9mm thick, cross tee 28.6x24x0.9mm and wall angle 19x19x0.9mm duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisons for light fixtures of any size and finally applying two coats of oil bound distemper with preparation of surfaces etc complete all as specified and directed.
M&L for aluminium anodised powder coated 3 truck window frame (section weighing not less then 1.10 Kg/RM) including sliding shutters (sections weighing not less than 0.55 kg/RM) including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as suitable handle (2 Nos.), locking arrangement & 5 mm thick tinted glass complete all as specified & directed.
M&L for aluminium anodised powder coated window grill (section weighing not less then 1.20 Kg/Sqm) including necessary joining cleats, anodised aluminium snap beading, screws complete all as specified & directed.
M&L for preparation of new wooden surfaces and applying two coat of synthetic enamel paint over a coat of pink primer of any description not other wise described over 10 cm width or girth complete all as specified and directed
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide of any description not other wise described over 10 cm width or girth complete all as specified and directed.
Excavation in post holes and getting out in any type of soil (or similar holes) each n exc 0.5 cum, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm thick, watering and well ramming to a true surface and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in foudation filling, and mass concrete, complete all as specified and directed.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed.
Supply only MS Galvanised chain link fencing (not less than 1.75 Kg/Sqm) any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
S&F mild steel screw bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n.exc 5cm long and diameter of neck 12mm, complete all as specified and directed.
S&F mild steel work as in angle iron posts or struts in fencing and for making waterways, grills etc incl cutting tops to shape as directed, drilling holes notching for wire etc flat iron fillets (for securing wire mesh etc) incl all necessary conforming to GE-290 Gde E-165, complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe- 290 Gde-E-165, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, n exe 10cm in width or girth, not otherwise described, and applying two coat of synthic enamal paint or a coat of red oxide primer complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregates) as in kerb stone, copings, kneelers, apex stones, pier caps, bed plates, pintle blocks, anchorage blocks, corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar 1:4 including use and waste of formwork complete with joints to match complete all as specified and directed.
M&L for point wiring with single core FRLS PVC insulated 1100V grade cable with multistranded twisted copper conductor of size 1.5 Sqmm (Nominal area) drawn in and including non metallic rigid PVC concealed conduit, medium grade ISI marked not less than 20 mm dia, concealed in wall, ceiling with saddles, screw & Plugs with all fittings including tee, junction boxes and drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade FRLS cable with stranded copper conductor of size 1.5 sqmm and terminated in and including sunken box for switches/sockets, regulators etc complete all as specified and directed.
One light/fan point controlled by one, one way Switch.
One 3 pin socket outlet 5/6 Amps on indepented board.
One 3 pin socket outlet 5/6 Amps on same board.
Ditto all as per serial item No. 91.00 described here-in-before but size of 2.5 Sqmm (Nominal area) copper conductor
S&F switch piano flush type, single pole, one way 5 Amps ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 Amps ISI marked complete all as specified and directed.
S&F switch piano flush type, single pole 15 Amp, one way ISI marked complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 Amps flush type ISI marked complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/ Polycarbonate, isolated body ISI marked complete all as specified and directed.
S&F LED light fitting fixture 20W, 220 V AC, 6500K decorative ultra slim with driver co extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly having power factor >0.95, surge protection 2.5KV energy efficient ready to use complete all as specified and directed. Make-Wipro/Philips/GE
M&L for sub main wiring with two single core 6.0 sqmm FRLS, ISI marked PVC insulated multi stranded, unsheathed twisted copper conductor cable and one single core unsheathed FRLS , ISI marked, PVC multistranded twisted copper conductor cable of size 6.0 sqmm green colour as earth lead including concealed PVC conduit medium grade of suitable size, including taking down unservicable cable complete all as specified and directed. Make- Cable- Finolex/RR cable/Havells, PVC Casing Capping / Conduit - Presto plast/Finolex/Kalinga.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 10 Cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
S&F MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection including taking down old unserviceable complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW08 or equivalent in Schnieder/GE/C&S.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 40 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: Havells/Inod Asian/ABB
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: Havells/Inod Asian/ABB
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 6 to 32 Amps and current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: Havells/Inod Asian/ABB
S&F LED security light fitting 40 W made out of pressure die cast iron aluminium housing with high power LED with lens embeded PC cover and seperate driver compartment with IP 66 including making electric connection with GI bracket of 40 mm light grade 1.5 RM in bend shape, clamps and accessories complete all as specified and directed. Make: Havells/HPL/CG
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 16 sqmm nominal cross section in service connections complete all as specified and directed.
ZAHOOR ENGINEERING WORKS
M/S NORTHERN ELECTRICAL WORKS
ORISON ENTERPRISES
M/S Tajamul Ah Buchh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .