| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹43.7 L+₹24,136 (0.56%)Rejected-Finance FLAT NO B 401 4TH FLOOR NAVADURGA CO OP HSG SOCIETY LTD PLOT NO 7 SECTOR 19A NERUR EAST NAVI MUMBAI THANE MAHARASHTRA 400 706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Being other than Lowest | |
| 3 | L3₹45.8 L+₹2.4 L (5.47%)Rejected-Finance FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being other than Lowest | |
| 4 | L4₹48.6 L+₹5.2 L (12.0%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | L4 | Rejected-Finance Being other than Lowest |
Tender Value
₹57 L
EMD Value
₹1.1 L
Closing Date
1 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR AND MAINT TO CERTAIN BUILDINGS IN ZONE 1 IN ND MBI UNDER AGE BR I UNDER GE NW KUNJALI
2020_MES_351324_2
8365/CWE(NW)/MUMBAI
Open Tender
Civil Works - Highways
Item Rate
180 days
GE NW KUNJALI
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE NW KUNJALi
₹1.1 L
Yes
25 Aug 2020
18 Jul 2020
3 Aug 2020
18 Jul 2020
1 Aug 2020
18 Jul 2020
60 days
Amount
Taking down chowkats or frame with shutter ( without taking off shutter from frame) , n exc 1.5 sqm each complete all as specified and directed.
Taking down chowkats or frame with shutter ( without taking off shutter from frame) exc 1.5 sqm but n exc 4 Sqm each complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swanneck, etc. including cleaning or refixing or removal to store ( measured over all as fixed along the centre line over fittings and accessories)
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed..
Dismantling false ceiling/boarding any description fixed in any position with nails complete all as specified and directed..
Taking down 15mm bore, GI tubing and connections including cleaning for refixing or removal to store complete all as specified and directed..
All as per item No. 8 above but 20 mm bore GI Pipe.
Dismantling 100/75 mm bore, cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches if required complete all as specified and as directed complete all as specified and directed..
Dismantling floor hearth or wall tiling including cement mortat bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed..
Hacking out old broken glass (any thickness, size, quality or description) from wooden & Steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
Taking down cement plaster on brick/ surfaces built in cement mortar including raking out joints, bading for key scrubbing down with water complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed..
Demolition of brick work or stone /boulder masonry built in cement mortar, including all quoins, arches, pillars complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (old Size) straight or curved on plan exc 6 m mean radius and built in CM (1:6) complete all as specified and directed.
All as per item No. 17 above but half brick thick wall built in CM 1:4.
M&L 100 mm thick PCC 1:2:4 type B-I using 20mm graded stone aggregates as in floor finished cement concrete surfaces even and smooth using extra cement complete all as specified and directed.
S&F Aluminium dividing strips, 1.5mm thick, 38mm wide inserted in position, conform to design complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B I using 20mm graded stone aggregates as in floor finished cement concrete surfaces even and smooth using extra cement complete all as specified and directed.
S&F for 1st class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F Ist class hard wood glazed and skelton shutter 30 mm thick window shutters divided into squares with plain chamfered or rounded mitred and rebated sash bars with edges of shas bars and frame moulded, fitted with out and mitred beeds for screwing glass/guage etc size of members of shutters as specified in SSR Part-I Section 8.20 (b) complete all as specified and directed.
S&F 35 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side complete all as specified and directed..
S&F Powder coated aluminium frame for doors, windows ventilators and partitions with one or more rebates including joining cleat for fixing complete all as specified and directed.
M&L Sheet glass 4 mm thk, ordinary quality and glazing in aluminium beading with screws/ rebates in square exc 0.5 sq.m in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.4mm complete all as specified and directed..
S&F 12mm thick, toughened glass for door shutters, partitions, sheves etc with and including fitting and fixtures such as glass handles ss studs, fittings for door pivots complete all as specified and directed.
M&L for water proofing plaster for sunken portion in CM 1:3, 15 mm thick in two coats with integral water proofing compound at the rate of 3 % by weight of cement and finishing the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for water proofing treatment of sunken floor / wall surfaces by applying two coats of elastomeric coatings of BRUSHBOND RSX in FOSROC or TECKFORCE 2K STRONG in CHOWKSEY CHEMICALS as a two component flexible elastomeric coating with minimum 2mm thickness layer complete as per manufacturer’s instruction’s and as directed.
S&F Solid PVC door frame of size 50mmX47mm made out of 5mm single side prelam PVC sheet used instead of plain colour PVC sheet (edges will be painted to match with prelam sheet) reinforced with MS square tube, supplying & fixing in opening as per specification.
S&F factory made solid PVC molded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6mm raised panel design with 2mm thick molded PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specific complete all as specified and directed..
M&L for aluminium anodized grill with suitable aluminium anodized frame of F/H section with suitable fixing screws/attachment etc complete all as per M/S Deco Grill Design No DG -102 , 7.5mm size grill i.e. made out of 75mm thick aluminium plate all as per manufacturer's specifications.
M&L for 12 mm thick pre-laminated Medium Density board, both side decorative lamination interior grade,fixed in aluminium/ wooden frame work complete all as specified and directed.
S&F 4mm thick backelite with decoratve choice laminated on both side complete all as specified and directed.
S&F 100 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed.
S&F Aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F aluminium anodised Barrel tower bolts of extruded section, length of bolt 200mm complete all as specified and directed.
S&F Extrude aluminium anodised alloy handles, fabricated type 200mm size complete all as specified and directed..
S&F Mortice lock, 4 liver vertical type, size 100mm complete all as specified and directed.
S&F aluminium (Die cast) body, door closer, hydraulically regulated, desig. No. 3, unversal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
M&L for double action floor spring hydraulically regulated made up of minium 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as per manufacturer's instruction.
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
S&F Roller blinds type made out of standard cloth of approved texture with necessary accessories etc fixed on window openings complete all as specified and directed.. Make: D' Décor of equivalent as approved by GE
S&F 3 mm thick aluminium composite panel plain of approved colour shade as required cutting, notching bending to shape and jointing including aluminium tubular section as required of size 25 x 25 x 1.4mm Thick etc. as in vertical/flat surface of wall incl making holes for light fixing complete all as specified and directed.
M&L for vitrified ceramic tiles 10 mm thick (square /rectangular ) polished dark shade, area of each tiles not exceeding 0.36 sqm, in floor etc. set and jointed in neet cement slurry and pointed white or coloured cement to match the dark shade of the tiles, with and including screed bed in CM 1:6, 20 mm complete all as specified and directed.
All as per item No. 46 above but as in skirting including 10mm thick rendering in CM. 1:4 as backing coat complete all as specified and directed.
M&L Vitrified ceramic tiles 10mm thick (square/rectangular) area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, (800 x 800 mm, Digital full nano polish/ VC vitrified) in floors/ wall etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No 48 above but as in skirting including 10mm thick rendering in CM. 1:4 as backing coat complete all as specified and directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles with and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Coloured glazed ceramic tiles in vertical surface 450X350X7mm thick with and including 10 mm thick cm (1:4) backing coat and Triangular filliting at top of skirting, set and jointed in neat cement paste and pointed in coloured cement to match the shade of the tiles complete all as specified and directed..
M&L for 20-25mm thick, machine cut, Kota stone slab, as in floors, steps, landing etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of slab, including cutting, polishing etc. with and including 20mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Hard wear stone (of any type) granite stone slab 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Hard wear stone 20mm thick (of any type) granite stone slab machine cut in skirting/dado laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing of type and including 10 mm thick backing coat in CM 1:3 complete all as specified and directed.
M&L Cleaning of surface of floor by brooming, washing and drying with cloth including removal of oil mats and provision of high density laminated wooden flooring (pergo) 8mm thick fixed in floors / skirting including moulding etc, including dismantling old unserviceable wooden flooring complete all as per manufacturer's instruction make:" Pergo / ROSETTA"
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit with and including 6mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction and complete all as specified and directed.. (Make : Everest or equivalent as approved by GE
Errection & dismantling of MS tubular double scaffolding (H frames) upto ht of 30 m & with necessary brassing, provision of necessary safety equipment to the skilled workers to carry out the work and covering with green cloth for carring out external facework of walls complete all as specified and directed.
M&L for PCC 1:7:12 type F2 using 40 mm graded stone aggregate as in filling (sunken portion). etc
M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate, using Pidiproof LW+ water proofing chemical of Dr. Fixit or equvalent as per manufacturer's instruction , as sub floor, 40mm thick. (Water Proofing Chemical shall be measured and paid separately)
Supply only Water proofing chemical Pidiproof LW+ of Dr. Fixit or Equvalent complete all as specified and directed..
M&L for providing 12 mm dia holes of 75mm deep @0.6 m c/c at junction of beams and columns as co-ordinal points for inserting/pouring mixture of resin base latex polymer and cement slurry by pressure grouting for column, beams and slabs, includind sealing the holes with CM 1:3, complete all as specified and directed.
M&L for taking down, chipping and removing the loose, spailt, damaged cement concrete, cement mortor surfaces of RCC Columns, beams, walls, chajjah etc and exposing the reinforced cement , wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortor in CM 1:3 mix , 40mm thk in two coats, using polymer @ 10 to15% by weight of cement complete & finally finishing the surface complete all as specified and directed. Make : Dr. Fixit/ Sunanda/ chemestik/ Fosrok. Note :-(New reinforcement and MS Sections will be measured and paid separately)
M&L for guniting (spreyed concrete) on damaged RCC surfaces of columns, slabs, beams etc with concrete mix 1:1.2:2.4 (cement : well graded coarse sand confirming to zone II: 8 mm down well graded coarse aggregate retained on 2.36 mm sieve) added with fibrilated Polypropene Fibres (125 gm per bag of cement) and chemical admixer (Polymer Monobond 5% of wt of cement) min thk of 60 mm incl high tensile welded wire mesh of 5 mm dia @ 50 mm spacing properly anchored with ext surfaces as per the reqmt/ recommenmdations of Engr-in-Charge Including removing all loose dirt, rust / scale from reinforcement etc by using wire brushes, sand paper incl cleaning of exposed surface of reinforcement using blower and applying single component solution of rust remover rust CHM I PIN (RB & CC) and applying one coat of Anticorrosive epoxy coating to steel reinforcement. Note:- (New reinforcement and MS Sections will be measured and paid separately)
S&F welded steel wire fabric, cut to length, fixed to steel members/ reinforcement steel, weigh per Sqm nexc. 4 Kg complete all as specified and directed..
M&L for RCC Type B1 1:2:4 using 20 mm graded stone aggregate slab supported on wall, beam and coulumn, roof, landings, balconies, canopies, deck slabs and in shelves and the like including all necessary form work complete all as specified and directed.
M&L for TMT mild steel bars,10 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0 complete all as specified and directed.
All as per item No. 66 above but as in stirrups.
S&F for rolled mild steel Sections of Grade Fe 410-W, (Gde- E-250) quqlity-A, as in post, runners, rafters, purlins, trusses, steps etc fixed with connecting plates including bending, welding complete all as specified and directed.
S&F for mild steel plates of Grade Fe 410-W, (Gde- E-250) quality-A as in connecting pletes, base plate etc. welding complete all as specified and directed.
S&F Mild steel bolts with diameter of neck exc 12mm and n. exc 20mm purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI baseds corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
All as per item No. 71 above but plain galvalume sheets for ridges/ Flashings.
M&L for 1.5 mm thick galvanised steel sheet as in Valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope complete all as specified and directed.
S&F 15 mm dia medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors complete all as specified and directed.
All As per item No. 74 above but 20mm dia medium GI Pipe complete all as specified and directed.
S&F white vitreous china squatting pan, 'orissa' pattern, water closet of size 580x440mm with integral foot rest, P/S trap etc, fixed in repair complete all as specified complete all as specified and directed.
S&F white vitreous china washed down water closet pan, (pedestal pattern), white, with and including P/S Trap, PVC solid type seat cover etc, fixed in repair complete all as specified and directed.
S&F vitreous china urinals,half stall type, flat back, white, with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in CM 1: 2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.(Exclusive of fixing supply pipe to flushing cistern , trap and waste pipe) complete all as specified and directed..
S&F white glazed earthen ware vitreous china wash hand basin of size 550x400mm with and including CI brackets, 32mm bore brass CP waste coupling Inlet/ outlet PVC flexible pipe complete all as specified and directed.
S&F 10 litres capacity PVC low level flushing cistern of approved make including ball valve,syphon set, inlet and outlet pipe, brackets etc. Complete.
S&F 50mm, low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors complete all as specified and directed.
S&F 15 mm bore dia of pipe, brass chromium plated fancy type bib tap fixed in repairs complete all as specified and directed.
S&F in repairs 15mm size Stop Valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle handle screwed both ends complete all as specified and directed.
S&F in repair 15 mm dia fancy type pillar tap cast copper alloy with capston heads chromium plated screwed down high pressure with or without hot or cold with long screws shanks and fly nuts screwed for iron pipes complete all as specified and directed.
S&F PVC Connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
S&F brass chromium plated shower rose 125mm size, fixed in repairs complete all as specified and directed.
S&F chromium plated, tubular towel rail 20mm dia, D type, 60 cm long between flange, fixed in repairs complete all as specified and directed..
S&F Soap dish, vitreous china white, approximat size 160X160X90mm fixed in repairs complete all as specified and directed.
S&F 160mm dia PVC ( SWR) grade pipes single socketed in any length with rubber ring joints fixed to walls with and including fixing clips, bends, elbow, shoes bends complete all as specified and directed. (Note:- Measurment shall be taken along the centre line of the pipes.)
S&F 110mm dia PVC ( SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls and laid in flloors/trenches complete all as specified and directed..
S&F 75mm dia PVC ( SWR) grade pipes single socketed in any length with rubber ring joints fixed to walls and laid in flloors/trenches complete all as specified and directed..
S&F 110mm dia PVC ( SWR) grade double T with access doors including fixing clips complete all as specified and directed.
All as per item No. 93 above but 75mm dia
M&L PVC SWR floor trap 75mm, plain with grating including setting and jointing with silvent cement complete all as specified and directed.
S&F polyethylene water storage rotational moulded, 2000 Ltrs Capacity, hoisted and fixed in position with connecting nipple, top cover etc. complete including dismantling old U/S tank of any description complete all as specified and directed..
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall, applying two coats of oil emlusion distemper over a coat wall care putty of 3mm thick and alkali primer complete all as specified and directed..
M&L for complete removal of existing treatment on wall surfaces and applying a coat wall care putty 3mm thick on plastered surfaces, preparatory to distempering and applying two coats of oil bound distemper over a coat of wall primer complete all as specified and directed..
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces in ceiling finishing the surface even and smooth complete all as specified and directed.
M&L for preparation of newly plastered surfaces in ceiling , applying three coats of white wash complete all as specified and directed..
M&L for complete removal of existing treatment in ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for plastering in CM 1:4, 20 mm thick in two coats (15 mm under coat plus 5mm finishing coat) using Pidiproof LW+ water proofing chemical of Dr. Fixit or equvalent as per manufacturer's instruction and finishing the surface seven and fair complete all as specified and directed.. (Water Proofing Chemical shall be measured and paid seperately)
M&L for preparation of newly plastered or un plastered wall surfaces, over 10cm girth, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer complete all as specified and as per manufacturer's instruction.
M&L complete removal of existing plastered wall surfaces, over 10cm girth, preparation of surfaces, applying two coats of 100% acrylic, weather resistant emlusion over a coat of exterior wall primer complete all as specified and as per manufacturer's instruction.
M&L for preparation of new decorated wooden surfaces of any description over 10 cm width or girth, applying a coat of synthetic eanmel paint complete all as specified and directed..
M&L for preparation of old decorated wooden surfaces of any description over 10 cm width or girth, applying a coat of synthetic eanmel paint complete all as specified and directed..
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete complete all as specified and directed..
M&L for preparation of old steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Removing excavated material & debris exc. 1.50 Km but n exc. 15 Km and depositing where directed, in soil complete all as specified and directed..
Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces complete all as specified and directed.
Taking down old U/S tube light fittings single / Twin ,Recessis mount fitting , etc and making good the distrubed surface matching with existing surface complete all as specified and directed.
Taking down old u/s MCB DBs complete with MCBs, isolator etc of any type and capacity from wall/ceiling etc & making good to the disturb surfaces complete all as specified and directed.
M&L point wiring complete with 1.5 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 1.5 Sq. mm as earth continuity conductor connected to common earth dolly complete all as specified and directed.
One light point controlled by one 5A switch
One Fan point controlled by one 5A switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L point wiring complete with 4 Sq.mm single core multistranded PVC insulated & unsheathed copper conductors cable 1100 volts FRLS grade ISI make and drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI make terminal boxes fixed on wall including one PVC insulated & unsheathed multistranded copper conductor 4Sq. mm as earth continuity conductor connected to common earth dolly for15 amp swich socket on independant board complete all as specified .
S & F in replacement of Switch piano flush type single pole one way ,5/6 Amps complete all as specified and directed.
Supply and fix switch sockets combination 5 pin 5 Amps flush type 240 Volts AC complete all as specified and directed.
Supply and fix in replacement switch socket combination multi purpose 3 pin 15 Amps controlled by one switch flush type 240 Volts AC complete all as specified and directed.
S & F in replacement of fan regulator electronic step type socket size and making all necessary connections complete all as specified and directed.
S & F in replacement of bell, DINGDONG type, 6 Amps, 240 volts, SP complete all as specified and directed.
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 teRunning Metreinal, 240 volts, 5 Amps complete all as specified and directed.
S & F in replacement 20 Amps Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed. make -Legrand Cat part no -507814,siemens ,GE
S & F in replacement 63 Amps Triple pole and earth encolsure with a three pin and earth plug with socket complete with one single pole MCB complete all as specified and directed. make -Legrand Cat part no -507864,siemens ,GE
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make- Legrand/Siemens/GE
S & F in replacement of MCB 0.5 to 4 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make- Legrand/Siemens/GE
S & F in replacement of MCB,SPN 40 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. .Make-Legrand,siemens,GE
S & F in replacement of MCB,SPN 63 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make-Legrand,siemens,GE
S & F in replacement of MCB, 4 Pole, 63Amps capacity, C Curve type suitable for 415 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed..make legrand Cat Part no-408702 Equivalent in Siemens,GE
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators complete all as specified and directed. Make - Legrand cat No 607732 or equivalent in Siemens/GE (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators. complete all as specified and directed. 607731 or equivalent in siemens/GE (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators complete all as specified and directed.. Make - Legrand cat No 607730 or equivalent in siemens/GE (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting TPN 4 way, 440 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s complete all as specified and directed. Make - Legrand cat part no 607735 or Equivalent in siemens/GE (Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25sq mm 3.5 core. laid in duct / along pole/wall tc including making connection complete all as specified and directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
S &F Ceiling light 36 WATT-2ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel:CYGNUS SERIES complete all as specified and directed. make- C&S CAT PART NO-LTCRSLM36WATT2X2
S &F 20 Watt 4 FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminiumextruded T5 LED Batten-integrated type complete all as specified and directed. Make- C & S CAT PART NO LTTB4F20WLED/W,OR Equivalent TO Havells,wipro,CG
S &F 10 Watt 2FT LED tube light fitting integrated Batten T5: Nakshatra series indooor light decorative alluminiumextruded T5 LED Batten-integrated type complete all as specified and directed. Make- C & S CAT PART NO LTTB210WLED/W ,OR Equivalent TO Havells,wipro,CG
S &F Ceiling light 36 WATT-2ft X 2 ft SURFACE mounted backlit panel,cygnus-cs series surface mounting powder coated with CRCA full glow LED panel:CYGNUS- CS SERIES complete all as specified and directed. make- C&S CAT PART NO-LTCSP36WLED2X2 OR Equivalent to HAVELLs,wipro,CG
Supply & Fix LED Slim down light;CARINA SERIES CARINA-RND/6W/W LED 6 watt white LED Round Recess PDC Aluminium Housing Downlights,warm light complete all as specified & directed. Make C&S cat part LTCRSM6HPLEDRND/W
Supply & Fix LED Slim down light;CARINA SERIES CARINA-SQ/6W/W LED 6 watt white LED Square Recess PDC Aluminium Housing Downlights,warm light complete all as specified and directed. Make -C&S,cat part no-LTCRSLM6HPLED/SQ/W
Supply & Fix LED RETROFIT LAMP: CHANDRA SERIES Product code CHANDRA/0.5W/R LTHPLED/0.5/R LED Retrofit Lamp B-22 holder base with poly carbonate diffuser and aluminium heat sink complete all as specified and directed. Make -C&S,cat part no-LTHPLEDLAMP0.5W.B22/R
Supply & Fix LED RETROFIT LAMP: CHANDRA SERIES Product code CHANDRA/0.5W/R LTHPLED/0.5/G LED Retrofit Lamp B-22 holder base with poly carbonate diffuser and aluminium heat sink complete all as specified and directed. Make -C&S,cat part no-LTHPLEDLAMP0.5W.B22/G
M & L in repair Submain wiring with two run 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one run PVC insulated & unsheathed multistranded copper conductor 4Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed
M & L Submain wiring with two run 6 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one PVC insulated & unsheathed multistranded copper conductor 6.0 Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed
S & F exhaust fan of sweep 300 mm heavy duty type complete with self closing MS louvers, mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.2 mm including fixing and making connection and fixed by using 4 Nos 200 mm long 12 mm dia bolts, nuts and washers and grouted in wall in CM 1:3 complete all as specified and directed. Make: Havells/CG/ khaitan
S & F Ceiling fan 5 Star Rated 1200 mm sweep heavy duty type complete with and suitable for operation on 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.2 mm including fixing and making connection and fixed by complete all as specified and directed. Make: Havells/CG/ khaitan
Supply & DLP PVC trunking system and accessories-trunking and fittings,Bodies supplied with out cover 105 x 50 mm complete all as specified and directed cat part n0-010422
Supply & DLP PVC trunking system and accessories-trunking and fittings,Flexible cover fits into the whole branch including in internal or external angles supplied with Body cover 85 mm complete all as specified and directed .cat part n0-010522
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6sq mm 2 core. laid in duct / along pole/wall etc including making connection complete all as specified and directed. Note :1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point or indicated including testing on completion complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead a by nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point or indicated including testing on completion complete all as specified and directed.
ROHIT CONSTRUCTION
RAJENDRA CONSTRUCTION
Garima Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .