| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹36.6 L+₹1.6 L (4.48%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹37.2 L+₹2.2 L (6.33%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance HIGHER RATE | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to OEM cert has not uploaded | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected due to OEM cert has not found uploaded |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L1 | SANJEEV ENTERPRISES L3 | SNOWY ENGINEERING INC L2 |
|---|---|---|---|---|---|---|
| 1.00 | Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed.
Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape | 80 | Each Job | 300 ₹24,000 | 1,000 ₹80,000 | 250 ₹20,000 Lowest |
| 2.00 | All as per item No 1.00 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed | 140 | Each Job | 500 ₹70,000 | 1,000 ₹1,40,000 | 300 ₹42,000 Lowest |
| 3.00 | Servicing of cassette type AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed
Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape | 10 | Each Job | 500 ₹5,000 Lowest | 1,000 ₹10,000 | 1,250 ₹12,500 |
| 4.00 | All as per item No 3.00 above but tower type AC of 2.0 to 4.0 Ton capacity of any make / model any type and 1.5/2 Ton capacity complete all as specified and directed | 6 | Each Job | 1,000 ₹6,000 Lowest | 1,000 ₹6,000 Lowest | 1,250 ₹7,500 |
| 5.00 | S&F in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed | 120 | Each | 350 ₹42,000 Lowest | 500 ₹60,000 | 350 ₹42,000 Lowest |
| 6.00 | M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge. | 35 | Each Job | 4,000 ₹1,40,000 | 500 ₹17,500 Lowest | 900 ₹31,500 |
| 7.00 | M&L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option (Gas charging shall be paid and measured under respective item) complete all as specified and directed | 20 | Each | 1,700 ₹34,000 Lowest | 3,700 ₹74,000 | 1,785 ₹35,700 |
| 8.00 | Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge | 250 | Kg | 1,700 ₹4,25,000 | 2,500 ₹6,25,000 | 1,250 ₹3,12,500 Lowest |
| 9.00 | M&L for repair of unserviceable PCB suitable for NON inverter Split type AC 1.5/2 TR and fixing the same complete all as specified and directed by Engineer-in-charge. | 20 | Each Job | 2,000 ₹40,000 | 1,200 ₹24,000 Lowest | 1,500 ₹30,000 |
| 10.00 | M&L for opening and taking down existing unserviceable PCB along with display unit and repairing & refixing of PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton split type AC complete all as specified and directed by Engr-in-Charge. | 40 | Each Job | 5,000 ₹2,00,000 | 2,000 ₹80,000 Lowest | 4,500 ₹1,80,000 |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF AIR CONDITIONING SYSTEMS ALONGWITH ITS CONNECTED ACCESSORIES AT KASHMIR HOUSE UNDER GE NEW DELHI
2025_MES_713990_1
NIT No GE/ND-18/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NEW DELHI
₹72,000
Yes
20 Sept 2025
12 Jun 2025
25 Jul 2025
12 Jun 2025
23 Jul 2025
25 Jun 2025
Amount
Servicing of Window type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape
All as per item No 1.00 above but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed
Servicing of cassette type AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed Note: The quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape
All as per item No 3.00 above but tower type AC of 2.0 to 4.0 Ton capacity of any make / model any type and 1.5/2 Ton capacity complete all as specified and directed
S&F in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 Volt for AC upto 4.00 Ton complete all as specified and directed
M&L for checking the leakage by feeding dry Nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas R-12/22/134a for water cooler, Split type/Window type AC/ Deep Freezer /Refrigerator any size any capacity as on site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option (Gas charging shall be paid and measured under respective item) complete all as specified and directed
Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified & directed by Engineer-in-charge
M&L for repair of unserviceable PCB suitable for NON inverter Split type AC 1.5/2 TR and fixing the same complete all as specified and directed by Engineer-in-charge.
M&L for opening and taking down existing unserviceable PCB along with display unit and repairing & refixing of PCB along with display unit suitable for Indoor unit of Inverter AC of capacity1.5/2 Ton split type AC complete all as specified and directed by Engr-in-Charge.
M&L for opening and taking down existing unsv PCB and reparing & refixing of PCB suitable for Outdoor unit of 1.5/2 Ton split type AC inverter AC complete all as specified and directed by Engr-in-Charge.
M&L for repair of unserviceable PCB of cassette/ tower AC of capacity 3.5 to 4.0 TR for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv PCB complete all as specified and directed by Engineer-in-charge.
S&F PCB of non inverter type split type AC of capacity 1.5 to 2.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified & directed by Engineer-in-charge.
S&F PCB of inverter type split type AC of capacity 1.5 to 2.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified & directed by Engineer-in-charge.
S&F PCB of Cassette/tower AC of capacity 3.0 to 4.0 Ton and fixing the same in respective units including opening & taking down existing unsv PCB complete all as specified & directed by Engineer-in-charge.
S&F in replacement of of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in replacement of of COPPER TUBING AND synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split AC units complete all as specified and directed. Make:- Supreme/Gulf-o-flex/Superlon.
S&F in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 TR as per sample complete all as specified and directed.
Supply only in replacement cordless Remote for inverter type ACs Hot & cool suitable for 1.5 Ton AC as per sample complete all as specified and directed.
Supply only in replacement cordless Remote for ACs suitable for 1.5/2 ton split/window AC as per sample complete all as specified and directed.
M&L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any Make as per existing size and shape complete all as specified and directed.
S&F in repair condensing coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
S&F in repair evaporating coil suitable for 1.5/2 Ton split/window type ACs as per existing size/shape and as per existing make complete all as specified and directed.
S&F in replacement reciprocating /Rotary type compressor suitable for 1.5 to 2.0 Ton capacity inverter/ non inverter split type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
S&F in replacement reciprocating/Rotary type compressor suitable for 1.5 to 2 Ton capacity window type AC of the same make and model as per existing make of ACs, refixing including brazing work etc, pressure testing & establishing vacuum for dehydration complete all as specified and directed.
S&F in replacement of three phase compressor suitable for 3.5 to 4.0 Ton capacity suitable of cassete /tower AC of the same make and model as per existing make of ACs complete all as specified and directed.
S&F in replacement new fan motor (inoor/outoor) 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
S&F in replacement new DC fan motor (inoor/outoor) 1/4,1/5 HP single/double shaft as per existing model sutaible for Split type ACs 1.5/2 Ton complete all as specified and directed.
S&F in replacement fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton AC's of any make/type complete as per requirement on site complete all as specified and directed.
S&F in replacement new DC fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassatte type AC's of any make/type complete as per requirement on site complete all as specified and directed.
S&F in replacement air direction changer louver motor (swing motor) suitable for split type ACs as per existing make and model complete all as specified and directed.
M&L for rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
S&F in replacement condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity window type Acs complete all as specified and directed.
S&F in replacement of condensor fan blade made out of aluminium /plastic suitable for upto 2 Ton capacity complete all as specified and directed.
S&F in replacement of condensor fan blade made out of aluminium /plastic suitable for upto 4.0 Ton capacity cassette type complete all as specified and directed.
S&F in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for window type AC complete all as specified and directed.
S&F in replacement of evaporating air blower made out of aluminium /plastic suitable for upto 2 Ton capacity for split type AC complete all as specified and directed.
S&F in replacement of indoor air blower made out of aluminium /plastic suitable for upto 4.0 Ton capacity type complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 4.0 sqmm complete all as specified and directed.
S&F in replacement PVC insulated flexible copper conductor 3 core 1100V Grade of size 6.0 sqmm complete all as specified and directed.
Repair to control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
Repair to control processing board (Remote control kit) inverter type with hand set including replacement of current transformer, ICs, dieods, resistances, sensors etc complete for 3.5/4 Ton cassette type ACs of any make & model complete all as specified and directed.
S&F in replacement voltage stablizer of capacity 3 to 5 KVA, copper wounded made of metalic body complete all as specified and directed.
S&F in replacement Metal Clad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
S&F in replacement modular AC board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
S&F in replacement of plug top 3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
Labour for checking and attending complants of ACs, Refrigerators etc of any capacity, rectification minor defects and make the equipment functional complete all as specified and directed. Note:- (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in kashmir House and he must submit copy of valid competency certificate of two (2) AC mechanics each having minimum working experience of two years in the field of air conditioning & refrigeration. The certificates shall be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, and these certificates to be uploaded on portal at the time of bidding and submit a physical copy in the office of GE, failing which bid of the contractor is liable to be rejected. The said certificates shall also forwarded by OEM through mail on e-mail id [email protected] (b) The complaint should be attended on same day within 3 hours . (c) If the complaint not attended/not completed on same day within three hours recovery will be done as follows:- (i) For first day Rs.500/- (ii) For second day Rs.800/- (iii) For next every day Rs.1000/-
Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to work shop for carrying out necessary repair work, transportation back to location of installation , reinstallation/ refixing in position after complete repairs as required and making functional including testing complete all as specified and directed.
M&Lfor taking down Split/ Window AC and shifting from one position to other within te premises Complete with copper tubing indoor plate and copper tubing complete with all accessories with making good the disturbed surfaces with cement plaster and POP complete all as specified and as directed by Engr-in-Charge.
M&L for making suitable hole in the wall to fix window or split AC and maintain the surface as per existing condition complete all as specified and directed. Note : (a) plastering ,putty ,painting includede in the quoted rate. (b) covering the window by ply if nececssary also included in the quoted rate
S&F in replacement wall stand /chauki stand fastener upto 8 mm size to fix outdoor of split/ cassete ac made of metalic stell complete all as specified and directed. Note: (a) Srl Item No 8.00, 10.00, 11.00, 14.00, 15.00, 16.00 to 19.00, 24.00, 25.00, 26.00, 27.00, 28.00, 44.00, 45.00 and 46.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody. (b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge.
SNOWY ENGINEERING INC (BID ID -3361259)
SANJEEV ENTERPRISES (BID ID -3342888)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .